Wall LANEW1212RD 2 watt dc/dc converter single and dual outputs 2:1 wide input voltage range Datasheet

LANEW Series
2 Watt DC/DC Converter
Single and Dual Outputs
2:1 Wide Input Voltage Range
FEATURES
● Low Ripple & Noise
● 2 Watts Output Power
● Single and Dual Output
● External ON/OFF Control
● 2:1 Wide Input Voltage Range
● UL94-V0 Case Potting Materials
● Continuous Short Circuit Protection
● Input to Output Isolation up to 1KVDC
● SIP Package: 0.86 x 0.36 x 0.44 Inches
● No External Input and Output Capacitor Needed
SPECIFICATIONS: LANEW Series
o
All specifications are based on 25 C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
INPUT SPECIFICATIONS
5V nominal input
12V nominal input
Input Voltage Range
24V nominal input
48V nominal input
Input Current
Input Filter
Input Voltage Variation
dv/dt
Input Surge Voltage (100ms max)
Input Reflected Ripple Current
(There is an external capacitor at input (See Note 2))
Start Up Time
(Nominal Vin and constant resistive Load)
5V nominal input
12V nominal input
24V nominal input
48V nominal input
5V nominal input (100µF)
12V nominal input (100µF)
24V nominal input (10µF)
48V nominal input (10µF)
Power Up
Remote ON/OFF
DC-DC ON
DC-DC OFF
4.5 – 9 VDC
9 – 18 VDC
18 – 36 VDC
36 – 75 VDC
See Table
Capacitor Type
5V/ms, max
(Complies)
15 VDC
36 VDC
50 VDC
100 VDC
400mAp-p
150mAp-p
380mVp-p
170mVp-p
1ms typ
1ms typ
Open or high impedance
Control pin applied current
4 ~ 8mA max (via 1KΩ)
Remote OFF Input Current (nominal input)
1mA max
Application Circuit
Remote ON/OFF
OUTPUT SPECIFICATIONS
Output Voltage
Voltage Accuracy (Full load and nominal Vin)
Line Regulation (Low line to high line at full load)
Load Regulation (25% to 100% full load)
Cross Regulation (Dual)
Minimum Load (See Note 1)
Single Output
Dual Output
Asymmetrical load 25% / 100% FL
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
See Table
±1%
±0.5%
±0.75%
±1%
±5%
10% of full load
LANEW Series
2 Watt DC/DC Converter
Single and Dual Outputs
2:1 Wide Input Voltage Range
SPECIFICATIONS (CONTINUED)
OUTPUT SPECIFICATIONS (CONTINUED)
Output Power
Output Current
Ripple & Noise (20MHz bandwidth)
Transient Response Recovery Time
Temperature Coefficient
PROTECTION
Short Circuit Protection
GENERAL SPECIFICATIONS
Efficiency
Switching Frequency
Isolation Voltage (input to output)
Insulation Resistance
Isolation Capacitance
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Relative Humidity
Thermal Shock
Vibration
MTBF (see Note 3)
PHYSICAL SPECIFICATIONS
Weight
Dimensions
Case Material
Base Material
Potting Material
SAFETY & EMC
Safety Approvals and Standards
2 Watts max.
See Table
50mVp-p
500µs typ.
±0.1% / °C max.
25% load step change
Continuous, automatic recovery
See Table
100KHz, min.
1000VDC, min.
10GΩ min.
300pF
Full load to minimum load
-40°C to +85°C
-55°C to +105°C
5% to 95% RH
MIL-STD-810D
10-55Hz, 10G, 30 minutes along X, Y, and Z axis
5,017,000 hours
4.8 grams (0.17oz)
0.86 x 0.36 x 0.44 inches (21.8 x 9.2 x 11.1 mm)
Non-conductive black plastic
None
Silicon (UL94-V0)
Meets IEC60950-1, UL60950-1, EN60950-1
5V nominal input
12V nominal input
24V nominal input
48V nominal input
100µF & 10µF
100µF & 10µF
10µF & 120µF
10µF & 120µF
Meet EN55022 classes B recommend
circuit with an external L-C filter at input
EMC External Circuit
EMC Characteristics (See Note 4)
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
LANEW Series
2 Watt DC/DC Converter
Single and Dual Outputs
2:1 Wide Input Voltage Range
OUTPUT VOLTAGE / CURRENT RATING CHART
Model Number
LANEW533R
LANEW505R
LANEW509R
LANEW512R
LANEW515R
LANEW505RD
LANEW512RD
LANEW515RD
LANEW1233R
LANEW1205R
LANEW1209R
LANEW1212R
LANEW1215R
LANEW1205RD
LANEW1212RD
LANEW1215RD
LANEW2433R
LANEW2405R
LANEW2409R
LANEW2412R
LANEW2415R
LANEW2405RD
LANEW2412RD
LANEW2415RD
LANEW4833R
LANEW4805R
LANEW4809R
LANEW4812R
LANEW4815R
LANEW4805RD
LANEW4812RD
LANEW4815RD
Input Range
5 VDC
(4.5 – 9 VDC)
12 VDC
(9 – 18 VDC)
24 VDC
(18 – 36 VDC)
48 VDC
(36 – 75 VDC)
Output
Voltage
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
±5 VDC
±12 VDC
±15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
±5 VDC
±12 VDC
±15 VDC
Output Current
Min. load
Full load
50mA
500mA
40mA
400mA
22mA
222mA
17mA
167mA
13mA
134mA
±20mA
±200mA
±8mA
±83mA
±7mA
±67mA
50mA
500mA
40mA
400mA
22mA
222mA
17mA
167mA
13mA
134mA
±20mA
±200mA
±8mA
±83mA
±7mA
±67mA
50mA
500mA
40mA
400mA
22mA
222mA
17mA
167mA
13mA
134mA
±20mA
±200mA
±8mA
±83mA
±7mA
±67mA
50mA
500mA
40mA
400mA
22mA
222mA
17mA
167mA
13mA
134mA
±20mA
±200mA
±8mA
±83mA
±7mA
±67mA
Input Current (5) Efficiency (6)
540mA
615mA
596mA
588mA
582mA
645mA
595mA
598mA
202mA
234mA
222mA
219mA
220mA
242mA
224mA
226mA
102mA
115mA
109mA
109mA
108mA
117mA
112mA
110mA
52mA
60mA
56mA
55mA
55mA
62mA
57mA
57mA
65%
69%
71%
72%
73%
66%
71%
71%
72%
75%
79%
80%
80%
73%
78%
78%
71%
76%
80%
80%
81%
75%
78%
80%
70%
74%
78%
80%
79%
75%
77%
77%
Capacitor (7)
Load max
2200uF
1000uF
470uF
170uF
110uF
±470uF
±100uF
±47uF
2200uF
1000uF
470uF
170uF
110uF
±470uF
±100uF
±47uF
2200uF
1000uF
470uF
170uF
110uF
±470uF
±100uF
±47uF
2200uF
1000uF
470uF
170uF
110uF
±470uF
±100uF
±47uF
NOTES:
1. The LANEW Series requires a minimum 10% loading at the output to maintain specified regulation. Operation under
no-load condition will not damage these devices, however they may not meet all listed specifications.
2. It will not damage the device without inserting external input capacitors. There is a smaller reflected ripple current when
a capacitor is put at the input. The capacitor recommended is “CHEMICON” LXZ series or equivalent for 05 & 12Vin and
“CHEMICON” KMF series or equivalent for 24 & 48Vin.
3. BELLCORE TR-NWT-000332. Case: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
4. The LANEW series meet EN55022 classes A with a filter at input. The filter capacitor recommended is same as Note 2.
5. Maximum value at nominal input voltage and full load.
6. Typical value at nominal input voltage and full load.
7. Test by minimum Vin and constant resistive load.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
LANEW Series
2 Watt DC/DC Converter
Single and Dual Outputs
2:1 Wide Input Voltage Range
DERATING CURVE & EFFICIENCY GRAPHS
MECHANICAL DRAWING
Pin
1
2
3
5
6
7
8
PIN CONNECTION
Single Output
Dual Output
-INPUT
-INPUT
+INPUT
+INPUT
CTRL
CTRL
NC
NC
+OUTPUT
+OUTPUT
-OUTPUT
COMMON
NC
-OUTPUT
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797