Kersemi MUR610 6 amp super fast glass passivated rectifier 50 to 600 volt Datasheet

MUR605CT
THRU
MUR660CT
Features
•
•
•
•
Glass passivated chip
Superfast switching time for hight efficiency
Low reverse leakage current
High surge capacity
6 Amp Super Fast
Glass Passivated
Rectifier
50 to 600 Volts
Maximum Ratings
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Microsemi
Catalog
Number
MUR605CT
MUR610CT
MUR620CT
MUR640CT
MUR660CT
Device
Marking
MUR605CT
MUR610CT
MUR620CT
MUR640CT
MUR660CT
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
TO-220AB
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
S
4
A
U
1 2
6A
TC = 130°C
IFSM
75A
8.3ms, half sine
VF
640CT- 660CT
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Maximum Reverse
Recovery Time
605CT- 620
640CT
660CT
IR
IFM = 3 A per
.975V element;
1.25 V TA = 25°C*
5.0uA
50uA
Trr
TJ = 25°C
TJ = 100°C
IF=8.0A,
Irr=0.25A
35ns
60ns
75ns
3
H
PIN 1.
PIN 2.
PIN 3.
PIN 4.
Electrical Characteristics @ 25°C Unless Otherwise Specified
IF(AV)
Q
T
K
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element 605CT-620CT
C
B
F
ANODE
CATHODE
ANODE
CATHODE
V
L
J
D
R
G
N
A
B
C
D
F
G
H
J
K
L
Q
R
S
T
U
V
INCHES
.570
.620
.380
.405
.160
.190
.025
.035
.142
.147
.095
.105
.110
.155
.018
.025
.500
.562
.045
.060
.100
.120
.080
.110
.045
.055
.235
-----.045
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
http://www.kersemi.com
.255
.050
------
MM
14.48
9.66
4.06
0.64
3.61
2.42
2.80
0.46
12.70
1.14
2.54
2.04
1.14
15.75
10.28
4.82
0.89
3.73
2.66
3.93
0.64
14.27
1.52
3.04
2.79
1.39
5.97
----1.15
6.48
1.27
-------
MUR605CT thru MU660CT
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
100
10
60
6
40
4
605CT-620CT
2
20
1
10
.6
6
.4
4
.2
640CT-660CT
2
TJ=25°C
25°C
Amps
mAmps .1
1
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
.001
20
.2
.4
.6
.8
1.0
1.2
40
60
100
120
140
160
1.4
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Maximum Non-Repetitive Forward Surge Current
16
150
12
125
8
100
75
6
Amps
Amps
50
4
25
2
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
50
100
125
150
160
1
2
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
6
8 10
20
40
00
60 80 100
Cycles
175
°C
4
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
http://www.kersemi.com
Similar pages