Click on Series name for product info on aimtec.com Series AMEL10-MJZ 10 Watt | AC-DC / DC-DC Converter Picture coming soon FEATURES: • I/O Isolation 4000VAC • Operating Temp: -25°C to +70°C • Over current, Over Voltage • Input: 85-264VAC, 47-440Hz, or 100-370VDC • • • Low no load consumption ≤0.5W Continuous Short Circuit Protection Up to 83% efficiency Models Single output Model AMEL10-3.3SMJZ AMEL10-5SMJZ AMEL10-9SMJZ AMEL10-12SMJZ AMEL10-15SMJZ AMEL10-24SMJZ Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 100-370 100-370 100-370 100-370 100-370 100-370 (W) Output Voltage (V) Output Current max (A) Maximum capacitive load (µF) Efficiency (%) 6.6 10 10 10 10 10 3.3 5 9 12 15 24 2.00 2.00 1.10 0.90 0.70 0.45 15,000 12,000 6,000 2,000 1,500 500 71 76 80 81 82 83 Max Output wattage *Output power must not exceed the listed values. All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Current Inrush current <2ms (cold start) Leakage current External fuse Input dissipation Conditions Typical 115VAC 230VAC 115VAC 230VAC 0.23 0.15 slow blow type No Load 2 Conditions Typical 3.3V output Others Full load 10-100% load 20MHz bandwidth 230VAC ±3 ±2 ±0.5 ±1 50 80 Maximum Units ≤0.5 A A A A mA A W Maximum Units 10 20 0.25 Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise Hold up time % % % mV p-p ms 100 Isolation Specifications Parameters Tested I/O voltage Isolation resistance Conditions Typical 60 sec Rated Units 4000 VAC MΩ >1000 General Specifications Parameters Switching frequency Protection class Over current protection Over voltage protection Short circuit protection Short circuit restart Operating temperature www.aimtec.com F 052e R8 Conditions Typical 100% load 65 Class II 110 - 200 Zener Diode Clamp Continuous Auto recovery -25 to +70 Auto recovery See derating table Tel: +1 514 620 2722 1 of 3 Maximum Units KHz % of Iout o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MJZ 10 Watt | AC-DC / DC-DC Converter General Specifications (continued) Parameters Conditions Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Typical Maximum 100 Units o C C o %/ C o -25 to +105 ±0.02 Free air convection Non condensing 95 % RH Heat resistant black Plastic (flammability to UL 94V-0) 50 2.12 x 1.13 x 0.75 inches 53.80 x 28.80 x 19.00mm o > 300 000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load g Safety Specifications Parameters Agency approvals Standards cULus, CE pending Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Pin Out Specifications Pin Single 1 2 3 4 AC Input (N) AC Input (L) +V Output -V Output Dimensions 53.80 (2.12) 45.72 (1.80) Case Temperature Measurement point 1 3 1 10.16 (0.40) 28.80 20.32 (1.13) (0.80) TOP VIEW 4 2 19.00 (0.75) Ø 1.00 (0.04) Tel: +1 514 620 2722 2 of 3 3 4 5 Ø 1.5 (Ø 0.06) 6.00 (0.24) F 052e R8 TOP VIEW + 2 www.aimtec.com Meets IEC/EN/UL 60601-1, 2 x MOPP Meets IEC/EN/UL 60950-1 EN55011, class A IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 2, with application circuit IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11 Class 2 DIV: 5.08 (0.2) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Pin Pitch Tolerance ±0.35 (±0.014) Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-MJZ 10 Watt | AC-DC / DC-DC Converter Derating Free Air Convection at 25°C Free Air Convection 100 80 Output Power (%) 100 Safe Operating Area 70 Input 110-240VAC or 140-340VDC 60 50 40 80 Safe Operating Area 60 40 20 20 0 85 100 (100) (140) 0 - 25 -20 -10 55 0 20 40 70 60 80 100 Ambient Temperature º C 240 (340) 264 (270) Input Voltage VAC (VDC) Typical application circuit AC L Single Output FUSE 2A/250V 4 AC L MOV S14K350 AC AC N + Vout DC AC N C1 C2 1µF/50V + TVS 3 - Vout Class B compliance recommended circuit AC L FUSE 2A/250V MOV S14K350 LDM 4.7µH/2A CX 0.1µF/ 275VAC AC N CY1 1nF/ 400VAC AC CY2 1nF/ 400VAC AC N R2 12Ω/3W GND Model 3.3 & 5 Vout 9Vout 12 & 15 Vout 24 Vout C2 220 µF / 10V 120 µF / 25V 120 µF / 25V 68 µF / 35V Single Output R1 12Ω/3W LCM 2.2mH AC L +Vout +Vout DC - Vout C1 C2 1µF/50V + TVS - Vout TVS 7V 12V 20V 30V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only