BOSER MPE-F40 40w 85~264vac ac-dc open frame power supply Datasheet

MPE-F40
40W 85~264VAC AC-DC Open Frame Power
Supply
Industrial Power Supply
10.16
9.4
0.38
0.38
AC-DC
Vout(+)
AC L
Vout(-)
MPE-F40-05
MPE-F40-12
MPE-F40-24
MPE-F40-48
Output Min.
Voltage Load
+5V
0A
+12V
0A
+24V
0A
+48V
0A
Rated
Load
6A
3.34A
1.67A
0.834A
Voltage
Accuracy
4.9~5.1V
11.76~12.24V
23.5~24.5V
47.04~48.96V
3.048
Model No.
4.32
5.08
AC N
Specifications
Input Voltage
The range of input voltage is from 90~264VAC
Input Frequency
47~63Hz
Input Current
The maximum input current is 0.65A at 115VAC or 0.32A at
230VAC
Inrush Current
The cold inrush current will limit less than 50A at 264VAC input
voltage
Load Range
At factory, the output is checked between 4.9~5.1V(MPE-F40-05)/
11.76~12.24V(MPE-F40-12)/23.5~24.5V(MPE-F40-24)/47.04~
48.96V(MPE-F40-48) at 60% rated load
Ripple And Noise
The peak to peak ripple and noise is less than 50mV(MPE-F40-05)/
120mV(MPE-F40-12)/240mV(MPE-F40-24)/480mV(MPE-F40-48).
Measuring is done by 20MHz bandwidth limited oscilloscope and
terminated each output with a 0.1uF ceramic capacitor and a 10uF
electrolysis capacitor at rated load, nominal line
Line Regulation
The line regulation is less than +/-0.5% while measuring at rated
load and from 100VAC to 240VAC input voltage changing
Load Regulation
The load regulation for output is less than +/-1%, measuring is
done by changing the output load +/-40% from 60% rated load
Hold Up Time
Hold up time is 8mS typical at 115VAC input, full load
Efficiency
The efficiency is 78%(MPE-F40-05)/84%(MPE-F40-12)/86%(MPEF40-24)/88%(MPE-F40-48)typical while measuring is at nominal
line and rated load
Protection
The power supply will go into hiccup mode against short circuit or
over load conditions, and will do auto-recovery while faulty
conditions are removed
Temperature
0~+50oC (operating); -40~+85oC (storage)
Humidity
5~95%; non-condensing
Connectors
I/P Connector: Molex housing 09-50-3031 and Molex 2878 series
crimp terminal
O/P Connector: Molex housing 09-50-3031 and Molex 2878
series crimp terminal
Safety
UL 1950 / TUV EN60950 / CE mark
EMI
EN55022 class B
Dimensions
10.16 x 5.08 x 3.048 cm; tolerance specified is +/-0.4mm
Ordering Guide
MPE-F40-05
40W 85~264VAC
MPE-F40-12
40W 85~264VAC
MPE-F40-24
40W 85~264VAC
MPE-F40-48
40W 85~264VAC
Open Frame P/S (+5V Output Voltage)
Open Frame P/S (+12V Output Voltage)
Open Frame P/S (+24V Output Voltage)
Open Frame P/S (+48V Output Voltage)
Similar pages