LITEON LTL1KHTGP7DP1 Through hole lamp Datasheet

Through Hole Lamp
Product Data Sheet
LTL1KHTGP7DP1
Spec No.: DS20-2015-0001
Effective Date: 02/05/2015
Revision: -
LITE-ON DCC
RELEASE
BNS-OD-FC001/A4
LITE-ON Technology Corp. / Optoelectronics
No.90,Chien 1 Road, Chung Ho, New Taipei City 23585, Taiwan, R.O.C.
Tel: 886-2-2222-6181 Fax: 886-2-2221-1948 / 886-2-2221-0660
http://www.liteon.com/opto
Through Hole Lamp
LTL1KHTGP7DP1
Through Hole Lamp
LTL1KHTGP7DP1
Rev
P001
Description
Preliminary New Specification (RDR-20141374-03)
By
Date
Javy Huang
11/19/2014
Above data for PD and Customer tracking only
-
New Specification on OPNC
Javy Huang
1/9
12/29/2014
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
1. Description
Through-hole LEDs are offered in a variety of packages such as 3mm, 4mm, 5mm, rectangular, and cylinder which are suitable
for all applications requiring status indication. Several intensity and viewing angle choices are available in each color for design
flexibility.
1. 1. Features






Low power consumption & High efficiency
Lead free product & RoHS Compliant.
Popular T-1 diameter.
Source color is InGaN pure green 530nm.
Green diffused lens.
LED Lead frame has cutting.
1.2. Applications





Communication.
Computer.
Consumer.
Home appliance.
Industrial.
2. Outline Dimensions
Notes :
1.
2.
3.
4.
All dimensions are in millimeters (inches).
Tolerance is ±0.25mm (.010") unless otherwise noted.
Protruded resin under flange is 1.0mm (.04") max.
Lead spacing is measured where the leads emerge from the package.
5. Specifications are subject to change without notice.
2/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
3. Absolute Maximum Ratings at TA=25°C
Parameter
Maximum Rating
Unit
120
mW
(Duty Cycle≦1/10, Pulse Width≦10ms)
100
mA
DC Forward Current
30
mA
Power Dissipation
Peak Forward Current
Operating Temperature Range
-30°C to + 80°C
Storage Temperature Range
-40°C to + 100°C
Lead Soldering Temperature
[2.0mm (.079") From Body]
260°C for 5 Seconds Max.
4. Electrical / Optical Characteristics at TA=25°C
Parameter
Symbol
Min.
Typ.
Max.
Unit
IV
520
1000
1500
mcd
Test Condition
IF = 20mA
Luminous Intensity
2θ1/2
80
deg
Peak Emission Wavelength
λP
525
nm
Dominant Wavelength
λd
Spectral Line Half-Width
Δλ
Forward Voltage
VF
Reverse Current
IR
Viewing Angle
Note 1,5
Note 2 (Fig.6)
Measurement
523
530
538
30
2.6
nm
@Peak (Fig.1)
IF = 20mA, Note 4
nm
4.0
V
IF = 20mA
10
μA
VR = 5V (Note 6)
NOTE:
1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
4. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single wavelength which defines
the color of the device.
5. Iv guarantee must be included with ±15% testing tolerance.
6. Reverse voltage (VR) condition is applied for IR test only. The device is not designed for reverse operation.
3/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
5. Typical Electrical / Optical Characteristics Curves
(25°C Ambient Temperature Unless Otherwise Noted)
4/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
6. Packing Spec.
1000, 500, 200 or 100 pcs per packing bag
25 packing bags per inner carton
Total 25,000 pcs per inner carton
8 Inner cartons per outer carton
Total 200,000 pcs per outer carton
In every shipping lot, only the last pack will be non-full packing
5/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
7. Bin Table Specification
Luminous Intensity
Unit : mcd @20mA
Bin Code
Min.
Max.
M
520
680
N
680
880
P
880
1150
Q
1150
1500
Note: Tolerance of each bin limit is ±15%
Dominant Wavelength
Unit : nm @20mA
Bin Code
Min
Max
G11
523.0
527.0
G12
527.0
531.0
G13
531.0
535.0
G14
535.0
538.0
Note: Tolerance of each bin limit is ±1nm
6/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
8. CAUTIONS
8.1. Application
This LED lamp is good for application of indoor and outdoor sign, also ordinary electronic equipment.
8.2. Storage
The storage ambient for the LEDs should not exceed 30°C temperature or 70% relative humidity. It is recommended that
LEDs out of their original packaging are used within three months. For extended storage out of their original packaging, it is
recommended that the LEDs be stored in a sealed container with appropriate desiccant or in desiccators with nitrogen
ambient.
8.3. Cleaning
Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LEDs if necessary.
8.4. Lead Forming & Assembly
During lead forming, the leads should be bent at a point at least 3mm from the base of LED lens. Do not use the base of the
lead frame as a fulcrum during forming. Lead forming must be done before soldering, at normal temperature. During assembly
on PCB, use minimum clinch force possible to avoid excessive mechanical stress.
8.5. Soldering
When soldering, leave a minimum of 2mm clearance from the base of the lens to the soldering point. Dipping the lens into the
solder must be avoided. Do not apply any external stress to the lead frame during soldering while the LED is at high
temperature.
Recommended soldering conditions:
Soldering iron
Temperature
Soldering time
Position
350°C Max.
3 seconds Max.
(one time only)
No closer than 2mm
from the base of the epoxy bulb
Wave soldering
Pre-heat
Pre-heat time
Solder wave
Soldering time
Dipping Position
100°C Max.
60 seconds Max.
260°C Max.
5 seconds Max.
No lower than 2mm from the
base of the epoxy bulb
Note: Excessive soldering temperature and/or time might result in deformation of the LED lens or catastrophic
failure of the LED. IR reflow is not suitable process for through hole type LED lamp product.
8.6. Drive Method
An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs connected in parallel in an
application, it is recommended that a current limiting resistor be incorporated in the drive circuit, in series with each LED as
shown in Circuit A below.
Circuit model (A)
LED
Circuit model (B)
LED
(A) Recommended circuit
(B) The brightness of each LED might appear different due to the differences in the I-V characteristics of those LEDs.
7/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
8.7. ESD (Electrostatic Discharge)
Static Electricity or power surge will damage the LED.
Suggestions to prevent ESD damage:




Use a conductive wrist band or anti- electrostatic glove when handling these LEDs
All devices, equipment, and machinery must be properly grounded
Work tables, storage racks, etc. should be properly grounded
Use ion blower to neutralize the static charge which might have built up on surface of the LEDs plastic
lens as a result of friction between LEDs during storage and handing
Suggested checking list:
Training and Certification
8.7.1.1. Everyone working in a static-safe area is ESD-certified?
8.7.1.2. Training records kept and re-certification dates monitored?
Static-Safe Workstation & Work Areas
8.7.2.1. Static-safe workstation or work-areas have ESD signs?
8.7.2.2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V?
8.7.2.3. All ionizer activated, positioned towards the units?
8.7.2.4. Each work surface mats grounding is good?
Personnel Grounding
8.7.3.1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or conductive shoes
with conductive flooring?
8.7.3.1. If conductive footwear used, conductive flooring also present where operator stand or walk?
8.7.3.2. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*?
8.7.3.3. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs?
8.7.3.4. All wrist strap or heel strap checkers calibration up to date?
Note: *50V for Blue LED.
Device Handling
8.7.4.1. Every ESDS items identified by EIA-471 labels on item or packaging?
8.7.4.2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe workstation?
8.7.4.3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items?
8.7.4.4. All flexible conductive and dissipative package materials inspected before reuse or recycle?
Others
8.7.5.1. Audit result reported to entity ESD control coordinator?
8.7.5.2. Corrective action from previous audits completed?
8.7.5.3. Are audit records complete and on file?
8/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4
Through Hole Lamp
LTL1KHTGP7DP1
9. Reliability Test
Classification
Endurance
Test Item
Test Condition
Sample Size
Reference Standard
Operation Life
Ta = Under room temperature
IF = per datasheet maximum drive
current
Test Time= 1000hrs
22 PCS
(CL=90%;
LTPD=10%)
High Temperature
High Humidity
storage
Ta = 60°C
RH = 90%
Test Time= 240hrs
22 PCS
(CL=90%;
LTPD=10%)
High Temperature
Storage
Ta= 105 ± 5°C
Test Time= 1000hrs
22 PCS
(CL=90%;
LTPD=10%)
MIL-STD-750D:1031 (1995)
MIL-STD-883G:1008 (2006)
JEITA ED-4701:200 201 (2001)
Low Temperature
Storage
Ta= -55 ± 5°C
Test Time= 1000hrs
22 PCS
(CL=90%;
LTPD=10%)
JEITA ED-4701:200 202 (2001)
Temperature
Cycling
100°C ~ 25°C ~ -40°C ~ 25°C
22 PCS
30mins
5mins
30mins 5mins (CL=90%;
LTPD=10%)
30 Cycles
MIL-STD-750D:1051 (1995)
MIL-STD-883G:1010 (2006)
JEITA ED-4701:100 105 (2001)
JESD22-A104C (2005)
Thermal
Shock
100 ± 5°C ~ -30°C ± 5°C
15mins
15mins
30 Cycles
(<20 secs transfer)
22 PCS
(CL=90%;
LTPD=10%)
MIL-STD-750D:1056 (1995)
MIL-STD-883G:1011 (2006)
MIL-STD-202G:107G (2002)
JESD22-A106B (2004)
Solder
Resistance
T.sol = 260 ± 5°C
Dwell Time= 10±1 seconds
3mm from the base of the epoxy bulb
11 PCS
(CL=90%;
LTPD=18.9%)
MIL-STD-750D:2031(1995)
JEITA ED-4701: 300 302 (2001)
Solderability
T. sol = 245 ± 5°C
11 PCS
Dwell Time= 5 ± 0.5 seconds
(CL=90%;
(Lead Free Solder, Coverage ≧95% of
LTPD=18.9%)
the dipped surface)
MIL-STD-750D:1026 (1995)
MIL-STD-883G:1005 (2006)
MIL-STD-202G:103B (2002)
JEITA ED-4701:100 103 (2001)
Test
Environmental
Test
Soldering Iron
T. sol = 350 ± 5°C
Dwell Time= 3.5 ± 0.5 seconds
11 PCS
(CL=90%;
LTPD=18.9%)
MIL-STD-750D:2026 (1995)
MIL-STD-883G:2003 (2006)
MIL-STD-202G:208H (2002)
IPC/EIA J-STD-002 (2004)
MIL-STD-202G:208H (2002)
JEITA ED-4701:300 302 (2001)
10. Others
The appearance and specifications of the product may be modified for improvement, without prior notice.
9/9
Part No. : LTL1KHTGP7DP1
BNS-OD-FC002/A4