HY MP1006G Glass passivated bridge rectifier Datasheet

MP10005G thru MP1010G
GLASS PASSIVATED
REVERSE VOLTAGE
FORWARD CURRENT
BRIDGE RECTIFIERS
- 50 to 1000Volts
- 10.0 Amperes
MP8
FEATURES
METAL HEAT SINK
● Surge overload rating -200 amperes peak
.307(7.8)
.267(6.8)
● Low forward voltage drop
● Small size; simple installation
● Sliver plated copper leads
.750
(19.0)
MIN
● Mounting position: Any
.052(1.3)
DIA.
.048(1.2)
.770(19.6)
.730(18.5)
.520(13.2)
.480(12.2)
HOLE FOR
NO.6 SCREW
.770(19.6)
.730(18.5)
.520(13.2)
.480(12.2)
Polarity shown on side of case, Positive lead by beveled corner.
Dimensions in inches and (milimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave ,60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
SYMBOL
MP
10005G
MP
1001G
MP
1002G
MP
1004G
MP
1006G
MP
1008G
MP
1010G
UNIT
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
V
Maximum RMS Bridge Input Voltage
VRMS
35
70
140
280
420
560
700
V
CHARACTERISTICS
Maximum Average Forward
Rectified Output Current at
TA=50℃
I(AV)
10.0
A
IFSM
200
A
VF
1.1
V
Peak Forward Surge Current
8.3ms Single Half Sine-Wave
Super Imposed on Rated Load
Maximum Forward Voltage Drop
Per Bridge Element at 5.0A Peak
Maximum Reverse Current at Rated TJ=25℃
DC Blocking Voltage Per Element
Operating Temperature Range
Storage Temperature Range
TJ=100℃
10.0
μA
1.0
mA
TJ
-55 to +150
℃
TSTG
-55 to +150
℃
IR
~ 412 ~
RATING AND CHARACTERTIC CURVES
MP10005G thru MP1010G
FIG.2-MAXIMUM FORWARD SURGE CURRENT
250
10
PEAK FORWARD SURGE CURRENT
AMPERES
AVERAGE FORWARD OUTPUT CURRNT
AMPERES
FIG.1-DERATING CURVE
OUTPUT RECTIFIED CURRENT
8
T J=25°C
6
4
2
0
0
100
50
200
150
T J=25°C
100
50
0
150
10
1
100
NUMBER OF CYCLETS AT 60Hz
AMBIENT TEMPERATURE,°C
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
100
INSTANTANEOUS REVERSE CUNRRENT,
MICROAMPERES
INSTANTANEOUS REVERSE CUNRRENT,
AMPERES
10
10
1.0
T J=25°C
0.1
1.0
0.1
0.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE
0.01
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
INSTANTANEOUS FORWARD VOLTAGE,VOLTS