Emerson Network Power LPS22-T Universal input Datasheet

Embedded Power for
Business-Critical Continuity
Rev. 02.05.07
LPS25 Series
1 of 3
LPS25 Series
RoHS
25 Watts
Total Power:
Input Voltage:
# of Outputs:
25-40 Watts
85-264 VAC
120-300 VDC
Single
Electrical Specifications
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Universal input
3" x 5" footprint
Less than 1U high
Remote sense
Terminal block option (-T)
Built-in EMI filter
Low output ripple
Adjustable output
Overvoltage protection
Overload protection
110 KHz switching frequency
LPX40 enclosure kit available
2 year warranty
Safety
VDE
0805 EN60950
11774-3336-1241
(LC#84936)
UL
UL60950 E132002
CSA
CSA 22.2-234 Level 3
LR53982C
NEMKO EN 60950/EMKO-TUE
P95100442 (74-sec) 203
CB
Certificate and report
1577, 1578, 1579, 1580
CE Mark (LVD)
Input
Input range
85-264 VAC; 120-300 VDC
Frequency
47-440 Hz
Inrush current
<15A peak @ 115VAC; <30A peak @ 230VAC, cold start @ 25°C
Input current
1A max. (RMS) @ 115VAC
Efficiency
EMI filter
70% typical at full load
FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC input
Safety ground
leakage current
Output
Maximum power
25 W for convection; 40W with 30CFM forced air
Adjustment range
-5, +10% minimum
Hold-up time
Overload protection
20 ms @ 25W load, 115VAC nominal line
Short circuit protection on all outputs
Case overload protected @ 110 -145% above peak rating
Overvoltage protection 5V output; 5.7 to 6.7VDC. Other outputs 10% to 25% above
nominal output
Remote sense
Compensates for 0.5 V lead drop minimum
Will operate without remote sense connected
Reverse connection protected
Embedded Power for
Business-Critical Continuity
Rev. 02.05.07
LPS25 Series
2 of 3
Environmental Specifications
Operating temperature: 0° to 50°C ambient. Derate each output 2.5% per degree from
50° to 70°C, -20°C start up.
Storage temperature:
Electromagnetic
susceptibility:
-40°C to +85°C
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity:
Operating; non-condensing 5% to 95% RH
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four
major resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25°C ambient conditions
Vibration:
MTBF demonstrated:
Ordering Information
Model
Number
Maximum Load Maximum Load
Output Minimum
with Convection with 30CFM
Peak Load 1
Voltage Load
Cooling
Forced Air
Regulation 2
LPS22(-T)
5V
0A
5A
8A
9A
±2%
50 mV
LPS23(-T)
12V
0A
2.1A
3.3A
3.7A
±2%
120 mV
LPS24(-T)
15V
0A
1.7A
2.7A
3A
±2%
150 mV
LPS25(-T)
24V
0A
1.1A
1.8A
1.9A
±2%
240 mV
Ripple P/P
(PARD) 3
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and
load ranges.
4. (-T) indicates Terminal Block option for input and output (instead of Molex type)
Power Derating Curve
40W
30 CFM Forced Air Cooling
30W
Output
Power 25W
(Watts)
20W
10W
Natural
Convection
Cooling
20W
12.5W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
Embedded Power for
Business-Critical Continuity
Astec
Mechanical Drawing
0.22"
(5.6)
4.55"
(115.6)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
5.00"
(127)
M1 GND
SK201
3.00"
(76.2)
SK 1
1
M2
_+
1
2
3
4
5
6
2.55"
(64.8)
3
Rev. 02.05.07
LPS25 Series
3 of 3
N
Remote Sense
Connector
Voltage
Adj. Pot
SK 2
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
13-15, Shing Wan Road
Tai Wai, Shatin, N. T.
Hong Kong
Telephone: +852 2699 2868
Facsimile: +852 2699 1770
L
0.15" (4)
DIA (4 places)
For global contact, visit:
www.astecpower.com
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature,
Emerson Network Power assumes no responsibility,
and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
1.14"
(29)
0.197"
(5)
Pin Assignments
Mating Connectors
Connector LPS22
LPS23
LPS24
LPS25
SK1-1
SK1-3
Line
Neutral
Line
Neutral
Line
Neutral
Line
Neutral
SK2-1
SK2- 2
SK2- 3
+5 V
+5 V
+5 V
+12 V
+12 V
+12 V
+15V
+15V
+15V
+24V
+24V
+24V
SK2-4
Common
Common
Common
Common
SK2-5
SK2-6
SK201-1
SK201-2
Common
Common
+Sense
-Sense
Common
Common
+Sense
-Sense
Common
Common
+Sense
-Sense
Common
Common
+Sense
-Sense
AC Input:
Molex 09-50-8031 (USA) Not required for (-T) option
09-91-0300 (UK)
PINS: 08-52-0113
DC Outputs: Molex 09-50-8061 (USA) Not required for (-T) option
09-91-0600 (UK)
PINS: 08-52-0113
Remote
Molex 22-01-2025
PINS: 08-52-0123
Sense:
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
Astec Connector Kit #70-841-006, includes all of the above
DC Power
1.
Specifications subject to change without notice.
Embedded Power
2.
3.
6.
All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm)
Mounting holes M1 and M2 should be grounded for
EMI purposes.
Mounting hole M1 is safety ground connection.
Specifications are for convection rating at factory settings at
115 VAC input, 25°C unless otherwise stated.
Warranty: 2 year
7.
Weight: 0.5lbs/0.23kg
4.
5.
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Similar pages