P-DUKE FDC15-48D15 15 watts dc-dc converter Datasheet

FDC15 SERIES
15 WATTS
DC-DC CONVERTER
FEATURES
• 15 WATTS OUTPUT POWER
• OUTPUT CURRENT UP TO 3A
• STANDARD 2.00 X 1.60 X 0.40 INCH PACKAGE
• HIGH EFFICIENCY UP TO 82%
• 4:1 WIDE INPUT VOLTAGE RANGE
• SIX-SIDED CONTINUOUS SHIELD
• FIXED SWITCHING FREQUENCY
• UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
DESCRIPTION
The FDC15 series offer 15 watts of output power from a 2.00 x 1.60 x
0.40 inch package. The FDC15 series have 4:1 wide input voltage of
9~36VDC and 18~75VDC. The FDC15 features 1600VDC of isolation,
short-circuit and over-voltage protection.
APPLICATIONS
Wireless Network
Telecom/Datacom
Industry Control System
Measurement Equipment
Semiconductor Equipment
T E C H N I C A L S P E C I F I C AT I O N
All specifications are typical at nominal input, full load and 25ºC otherwise noted
INPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
Output power
15 Watts, max.
Voltage accuracy
± 1%
Minimum load (Note 6)
See Table
Voltage adjustability
Line regulation
LL to HL at Full Load
Single
Load regulation
Min. load to Full load
Dual
Cross regulation (Dual) Asymmetrical load 25% / 100% FL
Ripple and noise
20MHz bandwidth
Short circuit protection
Input filter
Pi type
± 0.2%
± 0.5%
± 1%
± 5%
Input reflected ripple current
250µs
6.2VDC
15VDC
18VDC
150%, max.
Continuous, automatics recovery
20mAp-p
Nominal input and
Start up time
20ms
Power up
constant resistive load
Remote ON/OFF (Note 7)
(Positive logic)
DC-DC ON
Open or 3.5V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
Input current of remote control pin Nominal input
-0.5mA~+0.5mA
Remote off state input current
Nominal input
20mA
ENVIRONMENTAL SPECIFICATIONS
Operating ambient temperature
Maximum case temperature
Efficiency
Input to Output
Input(Output) to Case
See table
1600VDC, min. 1minute
1600VDC, min. 1minute
Thermal impedance (Note 8)
-40ºC ~ +85ºC (with derating)
100ºC
Storage temperature range
GENERAL SPECIFICATIONS
9 ~ 36VDC
18 ~ 75VDC
50VDC 100ms, max.
100VDC 100ms, max.
24VDC input
48VDC input
Input surge voltage
See table
Transient response recovery time 25% load step change
5VDC output
Over voltage protection
12VDC output
Zener diode clamp
15VDC output
Over load protection
% of FL at nominal input
24VDC nominal input
48VDC nominal input
± 10%
±0.02% / ºC, max.
Temperature coefficient
Input voltage range
-55ºC ~ +125ºC
Natural convection
10ºC/Watt
Natural convection with heat-sink 8.24ºC/Watt
Thermal shock
MIL-STD-810F
9
Vibration
MIL-STD-810F
Isolation capacitance
300pF, max.
Relative humidity
Switching frequency
270kHz±10%
EMC CHARACTERISTICS
Isolation voltage
Isolation resistance
Safety approvals
500VDC
10 ohms, min.
IEC60950-1, UL60950-1, & EN60950-1
Case material
Nickel-coated copper
Base material
Non-conductive black plastic
Potting material
Epoxy (UL94 V-0)
2.00 X 1.60 X 0.40 Inch
(50.8 X 40.6 X 10.2 mm)
Dimensions
Weight
MTBF (Note 1)
Page 1 of 3
48g (1.69oz)
MIL-HDBK-217F
6
2.250 x 10 hrs
EMI
5% to 95% RH
EN55022
Class A, Class B
ESD
EN61000-4-2
Air ± 8kV
Perf. Criteria B
Contact ± 6kV
Radiated immunity
EN61000-4-3
10 V/m Perf. Criteria A
Fast transient (Note 9) EN61000-4-4
± 2kV Perf. Criteria B
Surge (Note 9)
EN61000-4-5
± 1kV Perf. Criteria B
Conducted immunity
EN61000-4-6
10 Vr.m.s Perf. Criteria A
www.pduke.com
2014/4/30
FDC15 SERIES
15 WATTS
DC-DC CONVERTER
(2)
(3)
Output Current
Output
Output
No load
Voltage Min. load Full load Ripple & Noise Input Current
Model
Number
Input
Range
FDC15-24S05
FDC15-24S12
FDC15-24S15
FDC15-24D05
FDC15-24D12
FDC15-24D15
FDC15-48S05
FDC15-48S12
FDC15-48S15
FDC15-48D05
FDC15-48D12
FDC15-48D15
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
9 ~ 36 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
18 ~ 75 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
210mA
100mA
80mA
± 105mA
± 50mA
± 40mA
210mA
100mA
80mA
± 105mA
±50mA
± 40mA
3000mA
1250mA
1000mA
± 1500mA
± 625mA
± 500mA
3000mA
1250mA
1000mA
± 1500mA
± 625mA
± 500mA
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
(4)
Eff
(%)
Capacitor
(5)
Load max
80
82
82
80
82
82
80
82
82
80
82
82
6800µF
890µF
570µF
± 1700µF
± 300µF
± 200µF
6800µF
890µF
570µF
± 1700µF
± 300µF
± 200µF
20mA
10mA
20mA
20mA
20mA
20mA
15mA
15mA
10mA
10mA
20mA
15mA
Note
1.
2.
3.
4.
5.
6.
7.
8.
9.
MIL-HDBK-217F @Ta=25 ºC, Full load.
Typical value at nominal input and full load. (20MHZ BW.)
Typical value at nominal input and no load.
Typical value at nominal input and full load.
Test by minimum input and constant resistive load.
The output requires a minimum loading on the output to maintain specified regulation. Operation under no-load condition will not damage
these devices, however they may not meet all listed specification.
The CTRL pin voltage is reference to -INPUT.
Heat-sink is optional and P/N: 7G-0011C-F.
An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Power Mate suggest:
Nippon chemi-con KY series, 220µF /100V.
FDC15-48S05 Derating Curve
120
120
O U T P U T P O W E R (% )
O U T P U T P O W E R (% )
CAUTION: This power module is not internally fused. An input line fuse must always be used.
100
80
60
40
20
0
-40
-20
0
20
62.5
40
60
80
100
120
100
80
60
40
20
0
AMBIENT TEMPERATURE(℃)
-40
E F F IC IE N C Y (% )
E F F IC IE N C Y (% )
82%
80%
78%
76%
74%
72%
70%
40
44
48
52
56
60
64
-20
0
20
40
60
69.1
80
100
120
90
100
AMBIENT TEMPERATURE(℃ )
FDC15-48S05
Efficiency VS Input Voltage
36
FDC15-48S05 Derating Curve
With Heatsink (Note
(Note 68))
68
72
INPUT VOLTAGE (V)
95
90
85
80
75
70
65
60
55
50
45
FDC15-48S05
Efficiency VS Output Load
10
20
30
40
50
60
70
80
OUTPUT LOAD (% of Full Load)
Page 2 of 3
www.pduke.com
2014/4/30
FDC15 SERIES
15 WATTS
DC-DC CONVERTER
MECHANICAL DRAWING
1. All dimensions in Inch (mm)
Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.01(0.25)
3. Pin dimension tolerance ±0.004 (0.1)
PIN CONNECTION
Page 3 of 3
PIN
SINGLE
DUAL
1
+INPUT
+INPUT
2
-INPUT
-INPUT
4
CTRL
CTRL
5
NO PIN
+OUTPUT
6
+OUTPUT
COMMON
7
-OUTPUT
-OUTPUT
8
TRIM
TRIM
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by
using the method shown below.
( ) for dual output trim
TRIM UP
TRIM DOWN
7(7)
8(8)
RU
8(8)
www.pduke.com
RD
6(5)
2014/4/30
Similar pages