OSRAM LF06P2-W4F-830-P Linearlight power flex Datasheet

www.osram.com/flex
LINEARlight POWER Flex ® Protect G2.1 (2016) – LF06P2-P
Technical Datasheet
Benefits
For outdoor use  IP67
High performance silicone:
 extreme long life time: 50.000 h
 high flexibility
Premounted feeder for easy connection
NEW: Slimmer Design
Reduced height: 3.7 mm
Elegant white appearance
Electronic components hidden
NEW: Shorter pitch compared to prior generation
Applications
11
150
5,100
25
3.7
General Lighting
Ships and boats, wall integration
Machine lighting
Path illumination, illuminated signs
Architectural lighting
all dimensions in mm
Quick reference
Product
Order Code
Color
K
W/m
lm/m
lm/W
Shipping Units
LF06P2-W4F-830-P
4052899400030.
white
3000
15.5
1250
81
8
LF06P2-W4F-835-P
4052899372771
white
3500
14.0
1350
96
8
LF06P2-W4F-840-P
LF06P2-W4F-860-P
LF06P2-W4F-890-P
4052899372795
4052899372818
4052899372832
white
white
white
4000
6000
10,000
14.0
14.0
15.5
1400
1400
1400
100
100
90
8
8
8
Technical features
Protection Type
IP 67 (outdoor use)
High performance Silicone
High UV-resistancy
Saltmist proof
Dimmable
Pulse width modulation (PWM)
Binning
Fine white
Lifetime
50,000 h
Adhesive tape on backside
Tesa (High Performance Tape)
Fulfilled standards/tests
Flammability: Glow-wire test with 850° – EN60598-1
Mixed gas corrosion test – IEC60068-2-60
Complementary systems
CONNECTsystem IP67 LP, SLIMCONNECTsystem (IP54),
SLIM TRACK, OPTOTRONIC
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12
LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P
1/4
www.osram.com/flex
Technical operating data (for overall module)
Product
Order Code
LF06P2-W4F-830-P
LF06P2-W4F-835-P
LF06P2-W4F-840-P
LF06P2-W4F-860-P
LF06P2-W4F-890-P
4052899400030.
4052899372771
4052899372795
4052899372818
4052899372832
Voltage
[V]
24
24
24
24
24
Power
[W]
79.1
71.4
71.4
71.4
79.1
Current
[A]
3.3
3.0
3.0
3.0
3.0
Luminous
Flux [lm]
6380
6890
7140
7140
7140
Radiance
Angle [°]
120
120
120
120
120
Overall
Length
5.1 m
5.1 m
5.1 m
5.1 m
5.1 m
Minimum & maximum ratings
LF06P2-P
Operating temperature at
Tc-Point [°C]
-20 … +50°C
Storage temperature
[°C]
-40 … +100°C
Voltage range
[V dc]
23 … 25 V
Reverse Voltage
[V dc]
24 V
► Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
► Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module.
► The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a
temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below.
Technical drawing
Safety information
► The module has to be protected from mechanical loads
► Assembly must not damage or destroy conducting paths on the circuit board.
► Installation of LED modules (with power supplies) needs to be made with regard to all applicable and safety standards. Only qualified
personnel should be allowed to perform installations.
► Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of no light. The module can be damaged after a few seconds. To prevent
this, correct polarity immediately! (see "reverse voltage", page 2)
► Parallel connection is highly recommended as safe electrical operation mode.
Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload the LED module.
► ESD protection methods have to be observed when cutting and connecting the module. Check on ESD handling in the application note
ESD protection for LED modules.
► The LED Module must not be operated under water
► Please ensure that the power supply is of adequate power to operate the total load.
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12
LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P
2/4
www.osram.com/flex
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically stabilized power
supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC
certified. In Europe the declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information")
OSRAM OPTOTRONIC® control gear complies to all relevant standards and guarantees safe operation.
Assembly Information
► The smallest electrical unit (SEU) (150 mm- 6 LEDs) can be removed by cutting at the printed marks at the side.
► After cutting connect the module via CONNECTsystem IP67 LP. Insert module into connector and apply pressure on a hard surface until
locked.
► The mounting of the single LED coupons is facilitated by means of the double-sided adhesive on the back surface of the module. Care
must be taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt particle. The mounting substrate
must have sufficient structural integrity. Take care to completely remove the adhesive backing. Once the module is appropriately
positioned, press on the module with about 20N/cm² (refer to application techniques of Tesa adhesive transfer tapes).
To support adhesion at higher temperatures, use additional mounting brackets if temperature exceeds Tc = 40°C.
► The module has to be mounted on a metal heat sink!
► The minimum bending radius is 5 cm.
► When installing in environments with large variations in temperature (e.g. outdoor applications) and operating length of more than 2 m, the
use of adequate mounting surfaces is necessary . Otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress
of any mismatch in expansion.
► If temperature exceeds Tc = 40°C, additional mounting brackets are needed.
► Pay attention to avoid highly corrosive atmospheres, e.g. permanent high humidity or Hydrogen Sulfide (H2S).
With current LED technology, H2S is causing accelerated corrosion which will lead to shortened timelife or premature failure.
Sources for H2S may be rubber, foamed rubber, soft-foam-tapes, sealings on rubber basis, natural sources (e.g. sulfur springs), etc.
To avoid H2S from sulfur-vulcanized rubber it is necessary to switch to silicon based materials or rubber that is Peroxid-crosslinked.
Indication may be found in the material datasheet of the rubber supplier.
Complementary systems and accessories
Accessories
Type
CONNECTsystem IP67
Endcap for module
2pin Feeder
2pin Jumper
SLIMCONNECTsystem IP54
2pin Feeder
Jumper (board-to-board) (also add: 4008321841926)
IP54 Protection for Jumper (4008321832467)
SLIM TRACK System
SLIM TRACK
Mounting Bracket for SLIM TRACK
Clear SLIM TRACK Cover
Diffuse SLIM TRACK Cover
Endcap for Diffuse Cover
Semi-Diffuse SLIM TRACK Cover
Product
EAN
Shipping units
LF-ENDCAP IP67 LP
LF-2PIN IP67 LP
LF-2CONN IP67 LP
4052899902565
4052899125711
4052899125735
10
5
5
LF-2PIN Flex IP SC
LF-CONN Flex SC
LF-CONN Flex IP SC
4008321841902
4008321832467
4008321841926
10
25
25
LF-LTS-2100 SLIM TRACK
LF-LTS-MB
LF-LTS COVER C
LF-LTS-COVER-DIFFUSE
LF-LTS-ENDCAP
LF-LTS COVER S
4008321978981
4008321979025
4008321790187
4008321979001
4008321979049
4008321790200
40
35 / 280
40
40
20 / 160
40
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12
LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P
3/4
www.osram.com/flex
OPTOTRONIC & recommended max. operation length per driver
► Please consider that lengths may differ if further controls are installed.
Recommended OPTOTRONIC® drivers
LF06P2-W4F-830-P
LF06P2-W4F-840-P
EAN
LF06P2-W4F-876-P
Non-dimmable
OT 6/200-240/24 CE
4008321113269
up to 0.3 m
up to 0.3 m
OT 8/200-240/24
OT 20/220-240/24
OT 20/120-240/24 S
4008321040169
4050300618111
4050300662626
up to 0.45 m
up to 1.2 m
up to 1.2 m
up to 0.45 m
up to 1.35 m
up to 1.35 m
OT 30/220-240/24 P
OT 50/220-240/24
4052899043497
4052899905566
up to 1.8 m
up to 3.15 m
up to 2.1 m
up to 3.45 m
OT 50/220...240/24 P
4052899043510
up to 3.15 m
up to 3.45 m
OT 75/220-240/24
4050300817477
up to 4.8 m
up to 5.25 m ⁽*⁾
OT 75/220-240/24 E
4008321362476
up to 4.8 m
up to 5.25 m ⁽*⁾
OT 80/220-240/24 P
4008321981684
up to 5.1 m
up to 5.7 m ⁽*⁾
OT 120/220-240/24 P
4008321981707
up to 7.65 m ⁽*⁾
up to 8.55 m ⁽*⁾
OT 240/220-240/24 P
4008321981721
up to 15.45 m ⁽*⁾
up to 17.1 m ⁽*⁾
OTe 120/220…240/24 E
4008321645715
up to 7.65 m ⁽*⁾
up to 8.55 m ⁽*⁾
OT EASY 60 II
4008321187796
up to 3.75 m
up to 4.2 m
OT EASY 80
4008321808363
up to 5.1 m
up to 5.7 m ⁽*⁾
OTi DALI 75/220-240/24 1-4 CH
4008321371560
up to 4.8 m
up to 5.25 m ⁽*⁾
OT 80/220-240/24 DIM P
4008321981677
up to 5.1 m
up to 5.7 m ⁽*⁾
OT 120/220-240/24 DIM P
4008321981691
up to 7.65 m ⁽*⁾
up to 8.55 m ⁽*⁾
OT 240/220-240/24 DIM P
4008321981714
up to 15.45 m ⁽*⁾
up to 17.1 m ⁽*⁾
Dimmable
⁽*⁾ Total length operable per driver. Length of single strip or sequential connection of multiple pieces may not exceed 5.1 m.
Maximim length per OT:
lA + lB + lC + …  lmax/OT
lA
Maximum length per strip:
lB
lA
lB
lC
l…
OT – 24V
lC
≤
≤
≤
≤
5.1 m
5.1 m
5.1 m
5.1 m
Contacts & information
German engineering meets Italian elegance – creating a European product
All LINEARlight POWER Flex® Protect are Made in Italy by OSRAM, with almost 100 years of experience in light solutions.
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 Munich, Germany
www.osram.com
+49.89.6213-0
Sales and technical support is given by the local OSRAM
subsidiaries.
On the OSRAM website all subsidiaries are listed with
complete address and phone numbers.
OSRAM LED Systems
OSRAM: FLEXIBLE LED MODULES
OSRAM catalogue
General information
www.osram.com/led-systems
www.osram.com/flex
http://catalog.osram.com
www.osram.com
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12
LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P
4/4
Similar pages