www.osram.com/flex LINEARlight POWER Flex ® Protect G2.1 (2016) – LF06P2-P Technical Datasheet Benefits For outdoor use IP67 High performance silicone: extreme long life time: 50.000 h high flexibility Premounted feeder for easy connection NEW: Slimmer Design Reduced height: 3.7 mm Elegant white appearance Electronic components hidden NEW: Shorter pitch compared to prior generation Applications 11 150 5,100 25 3.7 General Lighting Ships and boats, wall integration Machine lighting Path illumination, illuminated signs Architectural lighting all dimensions in mm Quick reference Product Order Code Color K W/m lm/m lm/W Shipping Units LF06P2-W4F-830-P 4052899400030. white 3000 15.5 1250 81 8 LF06P2-W4F-835-P 4052899372771 white 3500 14.0 1350 96 8 LF06P2-W4F-840-P LF06P2-W4F-860-P LF06P2-W4F-890-P 4052899372795 4052899372818 4052899372832 white white white 4000 6000 10,000 14.0 14.0 15.5 1400 1400 1400 100 100 90 8 8 8 Technical features Protection Type IP 67 (outdoor use) High performance Silicone High UV-resistancy Saltmist proof Dimmable Pulse width modulation (PWM) Binning Fine white Lifetime 50,000 h Adhesive tape on backside Tesa (High Performance Tape) Fulfilled standards/tests Flammability: Glow-wire test with 850° – EN60598-1 Mixed gas corrosion test – IEC60068-2-60 Complementary systems CONNECTsystem IP67 LP, SLIMCONNECTsystem (IP54), SLIM TRACK, OPTOTRONIC Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12 LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P 1/4 www.osram.com/flex Technical operating data (for overall module) Product Order Code LF06P2-W4F-830-P LF06P2-W4F-835-P LF06P2-W4F-840-P LF06P2-W4F-860-P LF06P2-W4F-890-P 4052899400030. 4052899372771 4052899372795 4052899372818 4052899372832 Voltage [V] 24 24 24 24 24 Power [W] 79.1 71.4 71.4 71.4 79.1 Current [A] 3.3 3.0 3.0 3.0 3.0 Luminous Flux [lm] 6380 6890 7140 7140 7140 Radiance Angle [°] 120 120 120 120 120 Overall Length 5.1 m 5.1 m 5.1 m 5.1 m 5.1 m Minimum & maximum ratings LF06P2-P Operating temperature at Tc-Point [°C] -20 … +50°C Storage temperature [°C] -40 … +100°C Voltage range [V dc] 23 … 25 V Reverse Voltage [V dc] 24 V ► Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module. ► Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module. ► The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For exact location of the Tc-point see drawing below. Technical drawing Safety information ► The module has to be protected from mechanical loads ► Assembly must not damage or destroy conducting paths on the circuit board. ► Installation of LED modules (with power supplies) needs to be made with regard to all applicable and safety standards. Only qualified personnel should be allowed to perform installations. ► Observe correct polarity! Depending on the product incorrect polarity will lead to emission of no light. The module can be damaged after a few seconds. To prevent this, correct polarity immediately! (see "reverse voltage", page 2) ► Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload the LED module. ► ESD protection methods have to be observed when cutting and connecting the module. Check on ESD handling in the application note ESD protection for LED modules. ► The LED Module must not be operated under water ► Please ensure that the power supply is of adequate power to operate the total load. Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12 LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P 2/4 www.osram.com/flex In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically stabilized power supply protecting against short circuits, overload and overheating. To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. Please see the relevant brochure for more detailed information (see "Related and Further Information") OSRAM OPTOTRONIC® control gear complies to all relevant standards and guarantees safe operation. Assembly Information ► The smallest electrical unit (SEU) (150 mm- 6 LEDs) can be removed by cutting at the printed marks at the side. ► After cutting connect the module via CONNECTsystem IP67 LP. Insert module into connector and apply pressure on a hard surface until locked. ► The mounting of the single LED coupons is facilitated by means of the double-sided adhesive on the back surface of the module. Care must be taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt particle. The mounting substrate must have sufficient structural integrity. Take care to completely remove the adhesive backing. Once the module is appropriately positioned, press on the module with about 20N/cm² (refer to application techniques of Tesa adhesive transfer tapes). To support adhesion at higher temperatures, use additional mounting brackets if temperature exceeds Tc = 40°C. ► The module has to be mounted on a metal heat sink! ► The minimum bending radius is 5 cm. ► When installing in environments with large variations in temperature (e.g. outdoor applications) and operating length of more than 2 m, the use of adequate mounting surfaces is necessary . Otherwise it is advisable to use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion. ► If temperature exceeds Tc = 40°C, additional mounting brackets are needed. ► Pay attention to avoid highly corrosive atmospheres, e.g. permanent high humidity or Hydrogen Sulfide (H2S). With current LED technology, H2S is causing accelerated corrosion which will lead to shortened timelife or premature failure. Sources for H2S may be rubber, foamed rubber, soft-foam-tapes, sealings on rubber basis, natural sources (e.g. sulfur springs), etc. To avoid H2S from sulfur-vulcanized rubber it is necessary to switch to silicon based materials or rubber that is Peroxid-crosslinked. Indication may be found in the material datasheet of the rubber supplier. Complementary systems and accessories Accessories Type CONNECTsystem IP67 Endcap for module 2pin Feeder 2pin Jumper SLIMCONNECTsystem IP54 2pin Feeder Jumper (board-to-board) (also add: 4008321841926) IP54 Protection for Jumper (4008321832467) SLIM TRACK System SLIM TRACK Mounting Bracket for SLIM TRACK Clear SLIM TRACK Cover Diffuse SLIM TRACK Cover Endcap for Diffuse Cover Semi-Diffuse SLIM TRACK Cover Product EAN Shipping units LF-ENDCAP IP67 LP LF-2PIN IP67 LP LF-2CONN IP67 LP 4052899902565 4052899125711 4052899125735 10 5 5 LF-2PIN Flex IP SC LF-CONN Flex SC LF-CONN Flex IP SC 4008321841902 4008321832467 4008321841926 10 25 25 LF-LTS-2100 SLIM TRACK LF-LTS-MB LF-LTS COVER C LF-LTS-COVER-DIFFUSE LF-LTS-ENDCAP LF-LTS COVER S 4008321978981 4008321979025 4008321790187 4008321979001 4008321979049 4008321790200 40 35 / 280 40 40 20 / 160 40 Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12 LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P 3/4 www.osram.com/flex OPTOTRONIC & recommended max. operation length per driver ► Please consider that lengths may differ if further controls are installed. Recommended OPTOTRONIC® drivers LF06P2-W4F-830-P LF06P2-W4F-840-P EAN LF06P2-W4F-876-P Non-dimmable OT 6/200-240/24 CE 4008321113269 up to 0.3 m up to 0.3 m OT 8/200-240/24 OT 20/220-240/24 OT 20/120-240/24 S 4008321040169 4050300618111 4050300662626 up to 0.45 m up to 1.2 m up to 1.2 m up to 0.45 m up to 1.35 m up to 1.35 m OT 30/220-240/24 P OT 50/220-240/24 4052899043497 4052899905566 up to 1.8 m up to 3.15 m up to 2.1 m up to 3.45 m OT 50/220...240/24 P 4052899043510 up to 3.15 m up to 3.45 m OT 75/220-240/24 4050300817477 up to 4.8 m up to 5.25 m ⁽*⁾ OT 75/220-240/24 E 4008321362476 up to 4.8 m up to 5.25 m ⁽*⁾ OT 80/220-240/24 P 4008321981684 up to 5.1 m up to 5.7 m ⁽*⁾ OT 120/220-240/24 P 4008321981707 up to 7.65 m ⁽*⁾ up to 8.55 m ⁽*⁾ OT 240/220-240/24 P 4008321981721 up to 15.45 m ⁽*⁾ up to 17.1 m ⁽*⁾ OTe 120/220…240/24 E 4008321645715 up to 7.65 m ⁽*⁾ up to 8.55 m ⁽*⁾ OT EASY 60 II 4008321187796 up to 3.75 m up to 4.2 m OT EASY 80 4008321808363 up to 5.1 m up to 5.7 m ⁽*⁾ OTi DALI 75/220-240/24 1-4 CH 4008321371560 up to 4.8 m up to 5.25 m ⁽*⁾ OT 80/220-240/24 DIM P 4008321981677 up to 5.1 m up to 5.7 m ⁽*⁾ OT 120/220-240/24 DIM P 4008321981691 up to 7.65 m ⁽*⁾ up to 8.55 m ⁽*⁾ OT 240/220-240/24 DIM P 4008321981714 up to 15.45 m ⁽*⁾ up to 17.1 m ⁽*⁾ Dimmable ⁽*⁾ Total length operable per driver. Length of single strip or sequential connection of multiple pieces may not exceed 5.1 m. Maximim length per OT: lA + lB + lC + … lmax/OT lA Maximum length per strip: lB lA lB lC l… OT – 24V lC ≤ ≤ ≤ ≤ 5.1 m 5.1 m 5.1 m 5.1 m Contacts & information German engineering meets Italian elegance – creating a European product All LINEARlight POWER Flex® Protect are Made in Italy by OSRAM, with almost 100 years of experience in light solutions. OSRAM GmbH Marcel-Breuer-Straße 6 80807 Munich, Germany www.osram.com +49.89.6213-0 Sales and technical support is given by the local OSRAM subsidiaries. On the OSRAM website all subsidiaries are listed with complete address and phone numbers. OSRAM LED Systems OSRAM: FLEXIBLE LED MODULES OSRAM catalogue General information www.osram.com/led-systems www.osram.com/flex http://catalog.osram.com www.osram.com Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. Subject to change without notice. Errors and omissions excepted. Version: 2016-07-12 LINEARlight POWER Flex® Protect G2.1 (2016) – LF06P2-P 4/4