PANDUIT FRLPR42BL 6x4 fiberrunner system spillout Datasheet

A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
6x4 FiberRunner ® System Spillouts
C.
Fiber
Optic
Systems
• Spill-overs allow safe transition from horizontal
to vertical runs
• 2" (50.8mm) bend radius control
D.
Power
over
Ethernet
Part Number
Part Description
Couplers
Required
Std. Std.
Pkg. Ctn.
Qty. Qty.
6x4 QuikLock™ Vertical Tee
E.
Zone
Cabling
F.
Wireless
• Transition to channel, slotted channel, and corrugated
loom tubing
• Spill-over junction fittings can be retro-fitted to existing
horizontal runs
FRVT6X4YL
Attaches to 6x4 channel and/or fittings to create
90° vertical drop from a straight horizontal run.
Hinged door included. Accepts FTR4X4YL,
FIDT4X4BL, S4X4YL6 or E4X4YL6 directly.
Accepts optional snap-on cover FRHC6YL6
in conjunction with channel.
(2 pcs.)
FRBC6X4YL
1
5
—
1
5
—
1
5
—
1
—
—
1
10
—
1
5
(1 pc.)
FBC2X2YL
1
—
FRVT6X4
3-Sided Vertical Tee Trumpet Spillout
FTR4X4YL
G.
Outlets
H.
Media
Distribution
I.
Physical
Infrastructure
Management
FTR4X4
2-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
FIDT4X4BL
FIDT4X4BL
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
FRHD4KT
Provides secure, accessible route for cables spilling
out from vertical tee to rack mounted equipment.
Kit includes 6' length of 4x4 capacity hinged duct,
6' length of 4x4 hinged duct cover, one end cap for
4x4 hinged duct, three FZBA1.5X4 adjustable “Z”
brackets, an adapter fitting, six WR4-C wire
retainers and all required mounting hardware.
Attaches directly to 6x4 and 4x4 vertical tee exit
or FRLPR64 low profile reducer.
4x4 Hinged Duct Bend Radius Control Trumpet
TRC4HDBL
TRC4HDBL
Used to route cable into one or two pieces of 1.5"
(38mm) diameter split corrugated tubing. Used with
FRVT6X4YL, FRVT4X4YL, or FVT4X4YL. Securely
holds corrugated split tubing to ensure system
integrity and easy access to add or remove cables.
Black color only.
4x4 Hinged Duct Vertical Cable Manager Kit
FRHD4KTYL
J.
Overhead &
Underfloor
Routing
Used to limit the bend radius of the cable to
2" (50.8mm) when exiting from a 4x4 or 6x4
FiberRunner ® Vertical Tee and 4x4
Fiber-Duct™ Fittings.
Bend radius control trumpet for exiting at the
sidewall of 4" wall heights of type H hinged cover
wiring duct channels. Maintains 1" (25.4mm) bend
radius control. Black color only.
Low Profile Reducer 4x4 to 2x2 for Vertical Tee
FRLPR42BL
N.
Industrial
Assembled into the 6x4 vertical tee FRVT6X4YL or
4x4 vertical tee FRVT4X4YL with an audible snap,
the FRLPR42BL allows for the transition to 2x2
FiberRunner ® or 2x2 Fiber-Duct™ Channel with
minimal space required. No tools required for
assembly. Black color only.
FRLPR42BL
Spill-Over Junction with 2x2 Exit
O.
Labeling &
Identification
P.
Cable
Management
Accessories
FRSPJ2X2YL
FRSPJ2X2
Assembles onto 4x4, 6x4, 12x4, or 24x4
FiberRunner ® Channel, spilling over the side into
a 2x2 vertical exit. Requires coupler to attach 2x2
FiberRunner ® and fittings to the vertical exit.
Mounts directly to existing installation with no
alteration required. Mounting hardware provided
for secure attachment.
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).
Q.
Index
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
6x4 FiberRunner ® System Spillouts (continued)
Part Number
Part Description
Couplers
Required
Std. Std.
Pkg. Ctn.
Qty. Qty.
Cover for Spill-Over Junction with 2x2 Exit for 6x4 Channel
FRSPJC26YL
FRSPJC26
Used to fully enclose 6x4 channel in conjunction
with the spill-over junction FRSPJ2X2YL. Cover
snaps onto the channel base. Hinged feature allows
easy access to add or remove cables.
—
1
5
FTR2X2
Used to limit the bend radius of the cable to 2"
(50.8mm) when exiting from a spill-over junction
with a 2x2 exit or from 2x2 Fiber-Duct ™ Channel.
Securely holds split corrugated tubing to ensure
system integrity and easy access to add or
remove cables.
(1 pc.)
FBC2X2YL
1
5
F.
Wireless
1-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
FIDT2X2YL
FIDT2X2
Used to route cable into one piece of 1.5" (38mm)
diameter split corrugated tubing. Used with a
spill-over junction with a 2x2 exit, 2x2 Fiber-Duct™
Fittings, and the 2x2 FiberRunner ® Hinged
Channel. Securely holds split corrugated tubing
to ensure system integrity and easy access to
add or remove cables.
(1 pc.)
FBC2X2YL
1
5
FRHD2KT
Provides secure, accessible route for cables spilling
out from a vertical tee or spill-over junction to rack
mounted equipment. Kit includes 6' length of 2x2
FiberRunner ® Hinged Channel H2X2YL6, 6' length
of 2x2 snap-on hinged cover HC2YL6, four
adjustable “Z” brackets FZBA1.5X4, one
FiberRunner ® 2x2 End Cap FHDEC2X2YL,
six hinged duct 2" wire retainers WR2H-C and
all required mounting hardware. Attaches to 2x2
vertical tee exit or spill-over junction with a 2x2
exit with a 2x2 QuikLock™ Coupler FBC2X2YL.
Also attaches directly to 4x4 or 6x4 vertical tee
exits with low profile reducer FRLPR42BL.
—
1
—
Bend radius control trumpet for exiting at the
sidewall of 2" wall heights of type H hinged cover
wiring duct channels. Maintains 1" (25.4mm) bend
radius control. Black color only.
TRC2HDBL
K.
Surface
Raceway
—
1
10
FRSPJ4X4
Assembles onto 4x4, 6x4, 12x4, or 24x4
FiberRunner ® Channel, spilling over the side into
a 4x4 vertical exit. Requires coupler to attach 4x4
FiberRunner ® Channel and fittings to the vertical
exit. Mounts directly to existing installation with no
alteration required. Mounting hardware provided
for secure attachment.
(1 pc.)
FRBC4X4YL
1
—
N.
Industrial
O.
Labeling &
Identification
Cover for Spill-Over Junction with 4x4 Exit for 6x4 Channel
FRSPJC46YL
FRSPJC46
Used to fully enclose 6x4 channel in conjunction
with the spill-over junction FRSPJ4X4YL. Cover
snaps onto the channel base. Hinged feature
allows easy access to add or remove cables.
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
Spill-Over Junction with 4x4 Exit
FRSPJ4X4YL
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
2x2 FiberRunner ® Bend Radius Control Trumpet
TRC2HDBL
G.
Outlets
H.
Media
Distribution
2x2 Hinged Duct Vertical Cable Manager Kit
FRHD2KTYL
D.
Power
over
Ethernet
E.
Zone
Cabling
3-Sided BRC Trumpet Spillout for 2x2 Exit
FTR2X2YL
C.
Fiber
Optic
Systems
—
1
5
P.
Cable
Management
Accessories
Q.
Index
www.panduit.com
Table continues on next page
For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see catalog back cover).
J.29
A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
6x4 FiberRunner ® System Spillouts (continued)
C.
Fiber
Optic
Systems
Part Number
D.
Power
over
Ethernet
Std. Std.
Pkg. Ctn.
Qty. Qty.
6x4 Dual Downspout
FRDDS6X4YL
E.
Zone
Cabling
FRDDS6X4
F.
Wireless
Attaches to 6x4 channel and/or fittings to create
two 90° 4x4 downward transitions from a horizontal
run. Downspouts are positioned 600mm apart to
provide drops into cable entrances on multiple
cabinet line-ups. The fitting maintains a 2" bend
radius control throughout the transition to the
vertical downspouts. Includes two snap-on throat
covers for the dual downspouts. Accepts optional
cover FRDDSHC6YL.
(2)
FRBC6X4YL
(2)
FRBC4X4YL
1
—
—
1
5
(1 pc.)
FRBC4X4YL
1
5
1
5
1
5
Cover for 6x4 Dual Downspout
FRDDSHC6YL
G.
Outlets
Part Description
Couplers
Required
FRDDSHC6
Used to fully enclose the 6x4 dual downspout fitting
FRDDS6X4YL. Cover is attached to the fitting base
with three hinge clips. The hinge clips allow the
hinged cover to rotate to a fully closed position
and an open position greater than 90°.
3-Sided BRC Trumpet Spillout for 4x4 FiberRunner ® Exit
H.
Media
Distribution
I.
Physical
Infrastructure
Management
FRTR4X4YL
2-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
FRTR4X4
FRIDT4X4YL
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
Used to route cable into one or two pieces of 1.5"
(38mm) diameter split corrugated tubing. Requires
coupler to be used with 4x4 FiberRunner ® Fitting.
Used with any 4x4 FiberRunner ® Fitting. Securely
holds corrugated split tubing to ensure system
integrity and easy access to add or remove cables.
(1 pc.)
FRBC4X4YL
1-Port Spillout Side Exit to 1.5" (38mm) Inside Diameter Corrugated Tubing
FRIDT4X4
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
Used to limit the bend radius of the cable to 2"
(50.8mm) when exiting from 4x4 FiberRunner ®
Channel or a 4x4 FiberRunner ® Horizontal Tee.
FR1.5IDE
FR1.5IDEYL
Used to route cable into 1.5" (38mm) diameter split
corrugated tubing directly through a hole cut in the
side wall of the 4x4, 6x4, and 12x4 FiberRunner ®
Channel or 4x4 Fiber-Duct ™ Channel. Provides 1"
(25.4mm) bend radius control at the exit. Securely
holds split corrugated tubing to ensure system
integrity and easy access to add or remove cables.
Includes drilling template.
—
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
A.
System
Overview
PHYSICAL INFRASTRUCTURE SYSTEMS
B.
Copper
Systems
6x4 FiberRunner ® System Spillouts (continued)
Part Number
Part Description
Couplers
Required
Std. Std.
Pkg. Ctn.
Qty. Qty.
3-Sided BRC Trumpet Spillout for 6x4 Exit
FRTR6X4YL
Used to limit the bend radius of the cable to 2"
(50.8mm) when exiting from 6x4 channel, 6x4
horizontal tee fitting, or 6x4 exit on 12x4
vertical tee.
(1 pc.)
FRBC6X4YL
1
5
FRUPS6X4YL
D.
Power
over
Ethernet
E.
Zone
Cabling
6x4 Up Spout
FRTR6X4
C.
Fiber
Optic
Systems
Allows cable to be directed upward out of the
channel deployed directly below racks and cabinets
in underfloor installations. Provides 2" (50.8mm)
bend radius. Snaps directly onto the channel and
can be positioned to allow cables to be laid in.
A 1" (25.4mm) top bezel is included. Other fittings
can be installed for specific applications including
FTR4X4YL and FIDT4X4BL.
—
1
5
F.
Wireless
G.
Outlets
FRUPS6X4
Innerduct Transition Fitting
Metal fitting attaches to end of channel or fitting
to transition up to four pieces of solid 1.5" (38mm)
inside diameter inner duct. Hardware is included
for installation. Black color only.
FITF6X4
FITF6X4
1
10
H.
Media
Distribution
3-Port Spillout to 1.5" (38mm) Inside Diameter Corrugated Tubing
FRIDT6X4YL
FRIDT6X4
—
Used to route cable into three separate pieces of
1.5" (38mm) diameter split corrugated tubing. Used
with FRVT12X4YL or any 6x4 fitting. Securely holds
corrugated split tubing to ensure system integrity
and easy access to add or remove cables.
For other colors replace suffix YL (Yellow) with OR (Orange) or BL (Black).
(1 pc.)
FRBC6X4YL
1
5
I.
Physical
Infrastructure
Management
J.
Overhead &
Underfloor
Routing
K.
Surface
Raceway
L.
Cabinets,
Racks &
Cable
Management
M.
Grounding &
Bonding
N.
Industrial
O.
Labeling &
Identification
P.
Cable
Management
Accessories
Q.
Index
www.panduit.com
For service and technical support, call 866-405-6654 (outside the U.S. and Canada, see catalog back cover).
J.31
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panduit:
FRSPJ2X2YL FRSPJC26YL
Similar pages