AC-DC Converter DIP-Package ASD-3 & ASD-4 Series FEATURES: Input voltage range 85-305Vac Short circuit, over current protections Board in-line type installation High voltage isolation 3000Vac 100% burn-in test 3 year warranty RoHS compliant Output voltage (Vdc) Output current (mA) Efficiency Typ. ASD3-3 ASD3-5 ASD3-9 3.3 600 64% 5 600 68% 9 330 70% ASD3-12 12 250 72% ASD3-15 15 200 76% 24 125 78% 3.3 800 64% ASD4-5 5 800 68% ASD4-9 9 444 70% ASD4-12 12 333 74% ASD4-15 15 270 76% ASD4-24 24 166 785 Model ASD3-24 ASD4-3 Input voltage (Vac) 85-305 Note: other input and output models may available on request. ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin -- 85 -- 305 Vac Input frequency Fline -- 47 -- 440 Hz Full load, Vin =115Vac -- 80 -- mA Full load, Vin =230Vac -- 40 -- mA Cold start, Vin =230Vac -- 20 -- A Input current Inrush current www.pairuigroup.com Iin Iinrush Page: 1 / 4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-3 & ASD-4 Series ELECTRICAL Input Parameters Efficiency Leakage current Rise time Symbols Test Conditions / Comment Min. Typ. Max. Units η 115-230Vac -- 75 -- % Ileakage Vin =230Vac -- 1 -- mA -- Vin =115Vac, full load -- 1000 -- ms Output Vout Vin=100-240Vac -- -- 2 % Line regulation Vout-line Vin=100-240Vac -- -- 0.2 % Load regulation Vout-load 20%-100% load -- -- 0.5 % Vripple -- -- 100 -- mV Output voltage accuracy Ripple Protection Over current The voltage start to decrease from 0.6A. When reaching 0.9A, it will turn off Short circuit Hiccup mode, it will auto-recovery after fault condition is removed Environment Storage Ambient operating temperature Operating relative humidity MTBF Tstorage Ta Humidity: 5% RH to 95% RH Startup at rated voltage (Please refer to derating curve) Ha TMTBF -40 -- +90 ℃ -40 -- +85 ℃ 10 -- 90 % -- -- 300 kHrs Non condensing Full load, 230Vac input, 25 ℃ ambient temperature Dimension(LxWxH) 35x25.4x17.8mm Safety&EMC Safety standards Design refer to UL60950, EN60950, EN60335, EN61558-2-16 Withstand voltage I/P-O/P: 3KVac Insulation Resistance I/P-O/P:>100M Ohms/500VDC/25 /70%RH EMI Conduction&Radiation Compliance to EN55014-1, EN55014-2, IEC62301, EN55022 CLASS B (CISPR22) www.pairuigroup.com 5mA /1min ℃ Page: 2 / 4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-3 & ASD-4 Series ELECTRICAL Safety&EMC EMS immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11 Harmonic current Compliance to EN61000-3-2, 3 RFI Compliance to FCC part 15 subpart B ELECTRICAL Notes: 1.Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and input nominal voltage. 2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. ℃ MECHANICAL CONNECTION PIN # SINGLE 1 NC 2 +Vo 3 -Vo 4 NC 5 AC(L) 6 AC(N) 7 NC Note: Unit is mm(inch). www.pairuigroup.com Page: 3 / 4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-3 & ASD-4 Series ELECTRICAL CURVE DERATING CURVE STATIC CHARACTERISTIC CURVE NOTE BLOCK DIAGRAM RECOMMENEDED TEST CIRCUIT www.pairuigroup.com Page: 4 / 4 Date: 07/30/2015 *Subject to change without notice