Dallas DS2406P+T Dual addressable switch plus 1kbit memory Datasheet

DS2406
Dual Addressable Switch
Plus 1kbit Memory
www.maxim-ic.com
FEATURES
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
PIN ASSIGNMENT
Open drain PIO pins are controlled and their
logic level can be determined over 1-Wire®
bus for closed-loop control
Replaces and is fully compatible with
DS2407 but no user-programmable power-on
settings and no Hidden Mode
PIO channel A sink capability of 50mA at
0.4V with soft turn-on; channel B 8mA at
0.4V
Maximum operating voltage of 13V at
PIO-A, 6.5V at PIO-B
1024 bits user-programmable OTP EPROM
User-programmable status memory to
control the device
Multiple DS2406’s can be identified on a
common 1-Wire bus and be turned on or off
independently of other devices on the bus
Unique, factory-lasered and tested 64-bit
registration number (8-bit family code +
48-bit serial number + 8-bit CRC tester)
assures error-free selection and absolute
identity because no two parts are alike
On-chip CRC16 generator allows detection
of data transfer errors
Built-in multidrop controller ensures
compatibility with other 1-Wire net products
Reduces control, address, data, programming
and power to a single data pin
Directly connects to a single port pin of a
microprocessor and communicates at up to
16.3 kbits/s
Supports Conditional Search with userselectable condition
Vcc bondout for optional external supply to
the device (TSOC package only)
1-Wire communication operates over a wide
voltage range of 2.8V to 6.0V from -40°C to
+85°C
Low cost TO-92, 6-pin TSOC and Flip Chip
surface mount package
TO-92
6-PIN TSOC PACKAGE
6
5
4
1
2
3
DALLAS
DS2406
TOP VIEW
SIDE VIEW
6
1
2
3
1
2
3
See Mech. Drawings
Section
BOTTOM VIEW
5
4
DS2406
yywwrr
###xx
1
2
3
Flip Chip, Top View with
Laser Mark, Contacts Not
Visible.
“yywwrr” = Date/Revision
###xx = Lot Number
See 56-G7019-001 for
package outline.
NOTE: The leads of TO-92 packages on tape-and-reel are
formed to approximately 100 mils (2.54 mm) spacing. For
details refer to drawing 56-G0006-003.
PIN DESCRIPTION
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
TO-92
Ground
Data
PIO-A
-------
TSOC/Flip Chip
Ground
Data
PIO-A
Vcc
NC
PIO-B
ORDERING INFORMATION
DS2406
TO-92 Package
DS2406/T&R
TO-92 Package, Tape & Reel
DS2406P
6-pin TSOC Package
DS2406P/T&R
TSOC Package, Tape & Reel
DS2406+
TO-92 Package
DS2406+T&R
TO-92 Package, Tape & Reel
DS2406P+
6-pin TSOC Package
DS2406P+T&R TSOC Package, Tape & Reel
DS2406X
Flip Chip, 10k Tape & Reel
+ Indicates lead-free compliance.
1 of 31
071107
DS2406
ADDRESSABLE SWITCH DESCRIPTION
The DS2406 Dual Addressable Switch Plus Memory offers a simple way to remotely control a pair of
open drain transistors and to monitor the logic level at each transistor’s output via the 1-Wire bus for
closed loop control. Each DS2406 has its own 64-bit ROM registration number that is factory lasered into
the chip to provide a guaranteed unique identity for absolute traceability. The device’s 1024 bits of
EPROM can be used as electronic label to store information such as switch function, physical location,
and installation date. Communication with the DS2406 follows the standard Dallas Semiconductor
1-Wire protocol and can be accomplished with minimal hardware such as a single port pin of a
microcontroller. Multiple DS2406 devices can reside on a common 1-Wire network and be operated
independently of each other. Individual devices will respond to a Conditional Search command if they
qualify for certain user-specified conditions, which include the state of the output transistor, the static
logic level or a voltage transition at the transistor’s output.
DS2406 BLOCK DIAGRAM Figure 1
PARASITE POWER
INT VDD
DATA
1-WIRE BUS
PROGRAM
VOLTAGE
DETECT
1-WIRE
FUNCTION
CONTROL
MEMORY
FUNCTION
CONTROL
CRC16
GENERATOR
DATA MEMORY
1024-BIT EPROM
(4 PAGES OF
32 BYTES EACH)
STATUS MEMORY
5 BYTES EPROM
1 BYTE SRAM
PIO-A
PIO-B
PIO
CONTROL
2 of 31
VCC
64-BIT
LASERED ROM
8-BIT
SCRATCHPAD
DS2406
OVERVIEW
The block diagram in Figure 1 shows the relationships between the major control and memory sections of
the DS2406. The device has four major data components: 64-bit lasered ROM, 1024 bits of EPROM data
memory, status memory, and the PIO-control block. The hierarchical structure of the 1-Wire protocol is
shown in Figure 2. The bus master must first provide one of the five ROM function commands: Read
ROM, Match ROM, Search ROM, Skip ROM, or Conditional Search ROM. The protocol required for
these ROM functions is described in Figure 13. After a ROM functions command is successfully
executed, the PIO-control and memory functions become accessible and the master may provide any one
of the six memory- and control function commands. The protocol for these functions is described in
Figure 7. All data is read and written least significant bit first.
HIERARCHICAL STRUCTURE FOR 1-Wire PROTOCOL Figure 2
Bus
Master
1-Wire Bus
Other
Devices
DS2406
Command
Level
1-Wire ROM Function
Commands (see Figure 13)
DS2406 specific
Memory Function
Commands (see Figure 7)
Available
Commands
Data Fields
Affected
Read ROM
Match ROM
Search ROM
Skip ROM
Conditional
Search ROM
64-bit ROM
64-bit ROM
64-bit ROM
N/A
64-bit ROM,
Conditional Search Settings
at Status Memory Location 7,
Device/Channel Status
Write Memory
Write Status
Read Memory
Read Status
Ext. Read Memory
Channel Access
1024-bit EPROM
Status Memory
1024-bit EPROM
Status Memory
1024-bit EPROM
PIO Channels
3 of 31
DS2406
PARASITE POWER
The DS2406 can derive its power entirely from the 1-Wire bus by storing energy on an internal capacitor
during periods of time when the signal line is high. During low times the device continues to operate off
of this “parasite” power source until the 1-Wire bus returns high to replenish the parasite (capacitor)
supply. In applications where the device may be temporarily disconnected from the 1-Wire bus or where
the low-times of the 1-Wire bus may be very long the VCC pin may be connected to an external voltage
supply to maintain the device status.
When writing to the EPROM memory, the 1-Wire communication occurs at normal voltage levels and
then is pulsed momentarily to the programming voltage to cause the selected EPROM bits to be
programmed. The bus master must be able to provide 12V and 10mA to adequately program the EPROM
portions of the device. During programming, only EPROM-based devices are allowed to be present on
the 1-Wire bus.
64-BIT LASERED ROM
Each DS2406 contains a unique ROM code that is 64 bits long. The first 8 bits are a 1-Wire family code.
The next 48 bits are a unique serial number. The last 8 bits are a CRC of the first 56 bits. (See Figure 3).
The 1-Wire CRC is generated using a polynomial generator consisting of a shift register and XOR gates
8
5
4
as shown in Figure 4. The polynomial is X + X + X + 1. Additional information about the Dallas 1Wire Cyclic Redundancy Check is available in Application Note 27. The shift register bits are initialized
to zero. Then starting with the least significant bit of the family code, 1 bit at a time is shifted in. After the
8th bit of the family code has been entered, then the serial number is entered. After the 48th bit of the
serial number has been entered, the shift register contains the CRC value. Shifting in the 8 bits of CRC
should return the shift register to all zeros. The 64-bit ROM and the 1-Wire Function Control section
allow the DS2406 to operate as a 1-Wire device and follow the protocol detailed in the section “1-Wire
Bus System”.
64-BIT LASERED ROM Figure 3
MSB
LSB
8-Bit CRC Code
MSB
48-Bit Serial Number
LSB
MSB
8-Bit Family Code (12h)
LSB
MSB
LSB
1-WIRE CRC GENERATOR Figure 4
Polynomial = X8 + X5 + X4 + 1
R
1ST
STAGE
X0
2ND
STAGE
X1
X2
3RD
STAGE
4TH
STAGE
X3
5TH
STAGE
X4
S
6TH
STAGE
X5
X6
7TH
STAGE
8TH
STAGE
X7
INPUT DATA
4 of 31
X8
DS2406
MEMORY MAP
The DS2406 has two memory sections, called data memory and status memory. The data memory
consists of 1024 bits of one-time programmable EPROM organized as 4 pages of 32 bytes each. The
address range of the device’s status memory is 8 bytes. The first seven bytes of status memory (addresses
0 to 6) are implemented as EPROM. The eighth byte (address 7) consists of static RAM. The complete
memory map is shown in Figure 5. The 8-bit scratchpad is an additional register that acts as a buffer when
writing the memory. Data is first written to the scratchpad and then verified by reading a 16-bit CRC
from the DS2406 that confirms proper receipt of the data and address. This process ensures data integrity
when programming the memory. If the buffer contents are correct, the bus master should transmit a
programming pulse (EPROM) or a dummy byte FFh (RAM) to transfer the data from the scratchpad to
the addressed memory location. The details for reading and programming the DS2406 are given in the
Memory Function Commands section.
DS2406 MEMORY MAP Figure 5
8-Bit Scratchpad
Page #
Address Range
Description
0
1
2
3
0000h to 001Fh
0020h to 003Fh
0040h to 005Fh
0060h to 007Fh
32-Byte final storage Data Memory
32-Byte final storage Data Memory
32-Byte final storage Data Memory
32-Byte final storage Data Memory
1K-Bit
EPROM
8 Bytes
Status
Memory
Valid Device
Settings
(SRAM)
00
Factory
Test Byte
Redirection
Bytes
Bitmap of
Used Pages
Write-Protect
Bits Data
Memory
DS2406 STATUS MEMORY MAP Figure 6
ADDRESS
0 (EPROM)
1 (EPROM)
2 (EPROM)
3 (EPROM)
4 (EPROM)
5 (EPROM)
6 (EPROM)
7 (SRAM)
BIT 7
BM3
1
1
1
1
BIT 6
BM2
1
1
1
1
BIT 5
BIT 4
BIT 3
BIT 2
BM1
BM0
WP3
WP2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
EPROM Factory Test byte
Don’t care, always reads 00
Supply
PIO-B
PIO-A
CSS4
CSS3
CSS2
Indication Channel Channel Channel Channel Source
(read only) Flip-flop Flip-flop Select
Select
Select
5 of 31
BIT 1
WP1
Redir. 0
Redir. 1
Redir 2
Redir 3
BIT 0
WP0
Redir. 0
Redir. 1
Redir 2
Redir 3
CSS1
Source
Select
CSS0
Polarity
DS2406
STATUS MEMORY
The Status Memory can be read or written to indicate various conditions to the software interrogating the
DS2406. These conditions include special features for the data memory, definition of the settings for the
Conditional Search as well as the channel flip-flops and the external power supply indication. How these
functions are assigned to the bits of the Status Memory is detailed in Figure 6.
The first 4 bits of the Status Memory (address 0, bits 0 to 3) contain the Write Protect Page bits which
inhibit programming of the corresponding page in the 1024-bit data memory area if the appropriate write
protection bit is programmed. Once a bit has been programmed in the Write Protect Page section of the
Status Memory, the entire 32-byte page that corresponds to that bit can no longer be altered but may still
be read. The remaining 4 bits of Status Memory location 0 are reserved for use by the 1-Wire File
Structure, indicating which memory pages are already in use. Originally, all of these bits are
unprogrammed, indicating that the device does not contain any data. As soon as data is written to any
page of the device under control of TMEX, the bit inside this bitmap corresponding to that page will be
programmed to 0, marking this page as used. These bits are application flags only and have no impact on
the internal logic of the DS2406.
The next four bytes of the Status Memory (addresses 1 to 4) contain the Page Address Redirection Bytes
which indicate if one or more of the pages of data in the 1024-bits EPROM memory section have been
invalidated by software and redirected to the page address contained in the appropriate redirection byte.
The hardware of the DS2406 makes no decisions based on the contents of the Page Address Redirection
Bytes. Since with EPROM technology bits can only be changed from a logical 1 to a logical 0 by
programming, it is not possible to simply rewrite a page if the data requires changing or updating. But
with space permitting, an entire page of data can be redirected to another page within the DS2406. Under
TMEX, a page is redirected by writing the one’s complement of the new page address into the Page
Address Redirection Byte that corresponds to the original (replaced) page. This architecture allows the
user’s software to make a “data patch” to the EPROM by indicating that a particular page or pages should
be replaced with those indicated in the Page Address Redirection Bytes.
Under TMEX, if a Page Address Redirection Byte has a FFh value, the data in the main memory that
corresponds to that page is valid. If a Page Address Redirection Byte has some other hex value than FFh,
the data in the page corresponding to that redirection byte is invalid. According to the TMEX definitions,
the valid data will now be found at the one’s complement of the page address indicated by the hex value
stored in the associated Page Address Redirection Byte. A value of FDh in the redirection byte for page 1,
for example, would indicate that the updated data is now in page 2. Since the data memory consists of
four pages only, the 6 most significant bits of the redirection bytes cannot be programmed to zeros.
Status Memory location 5 serves as a test byte and is programmed to 00h at the factory. Status Memory
location 6 has no function with the DS2406. It is factory-programmed to 00h to distinguish the DS2406
from the DS2407, which both share the same family code. A DS2407 with Status Memory location 6
programmed to 00h will power-up into hidden mode and will only respond if the bus master addresses it
by a Match ROM command followed by the correct device ROM code. Conversely, a device that does
respond to a Read ROM command with family code 12h can only be a DS2406 if its Status Memory
location 6 reads 00h.
6 of 31
DS2406
Status Memory location 7 serves three purposes: 1) it holds the selection code for the Conditional Search
function, 2) provides the bus master a memory mapped access to the channel flip-flops that control the
PIO output transistors, and 3) allows the bus master to determine whether the device is hooked up to a
VCC power supply. Bit locations 0 to 4 store the conditional search settings. Their codes are explained in
the section “ROM Function Commands” later in this document. The channel flip-flops are accessible
through bit locations 5 and 6 as well as through the Channel Access function. The power-on default for
the conditional search settings and the channel flip-flops is all 1’s. Setting a channel flip-flop to 0 will
make the associated PIO-transistor conducting or on; setting the flip-flop to 1 will switch the transistor
off, which is identical to the power-on default. With the VCC pin connected to a suitable power supply the
power indicator bit 7 will read 1. The power supply indicator can also be read through the Channel
Access function.
MEMORY FUNCTION COMMANDS
The “Memory Function Flow Chart” (Figure 7) describes the protocols necessary for accessing the
various data fields and PIO channels within the DS2406. The Memory Function Control section, 8-bit
scratchpad, and the Program Voltage Detect circuit combine to interpret the commands issued by the bus
master and create the correct control signals within the device. A three-byte protocol is issued by the bus
master. It is comprised of a command byte to determine the type of operation and two address bytes to
determine the specific starting byte location within a data field or to supply and exchange setup and status
data when accessing the PIO channels. The command byte indicates if the device is to be read or written
or if the PIO channels are to be accessed. Writing data involves not only issuing the correct command
sequence but also providing a 12-volt programming voltage at the appropriate times. To execute a write
sequence, a byte of data is first loaded into the scratchpad and then programmed into the selected address.
Write sequences always occur a byte at a time. To execute a read sequence, the starting address is issued
by the bus master and data is read from the part beginning at that initial location and continuing to the end
of the selected data field or until a reset sequence is issued. All bits transferred to the DS2406 and
received back by the bus master are sent least significant bit first.
Read Memory [F0h]
The Read Memory command is used to read data from the 1024-bit EPROM data memory field. The bus
master follows the command byte with a two-byte address (TA1=(T7:T0), TA2=(T15:T8)) that indicates
a starting byte location within the data field. Since the data memory contains 128 bytes, T15:T8 and T7
should all be zero. With every subsequent read data time slot the bus master receives data from the
DS2406 starting at the initial address and continuing until the end of the 1024-bits data field is reached or
until a Reset Pulse is issued. If reading occurs through the end of memory space, the bus master may
issue sixteen additional read time slots and the DS2406 will respond with a 16-bit CRC of the command,
address bytes and all data bytes read from the initial starting byte through the last byte of memory. This
CRC is the result of clearing the CRC generator and then shifting in the command byte followed by the
two address bytes and the data bytes beginning at the first addressed memory location and continuing
through to the last byte of the EPROM data memory. After the CRC is received by the bus master, any
subsequent read time slots will appear as logical 1s until a Reset Pulse is issued. Any reads ended by a
Reset Pulse prior to reaching the end of memory will not have the 16-bit CRC available.
Typically the software controlling the device should store a 16-bit CRC with each page of data to insure
rapid, error-free data transfers that eliminate having to read a page multiple times to determine if the
received data is correct or not. (See Application Note 114 for the recommended file structure). If CRC
values are imbedded within the data it is unnecessary to read the end-of-memory CRC. The Read
Memory command can be ended at any point by issuing a Reset Pulse.
7 of 31
DS2406
Extended Read Memory [A5h]
The Extended Read Memory command supports page redirection when reading data from the 1024-bit
EPROM data field. One major difference between the Extended Read Memory and the basic Read
Memory command is that the bus master receives the Redirection Byte (see description of Status
Memory) first before investing time in reading data from the addressed memory location. This allows the
bus master to quickly decide whether to continue and access the data at the selected starting page or to
terminate and restart the reading process at the redirected page address.
In addition to page redirection, the Extended Read Memory command also supports “bit-oriented”
applications where the user cannot store a 16-bit CRC with the data itself. With bit-oriented applications
the EPROM information may change over time within a page boundary making it impossible to include
an accompanying CRC that will always be valid. Therefore, the Extended Read Memory command
concludes each page with the DS2406 generating and supplying a 16-bit CRC that is based on and
therefore always consistent with the current data stored in each page of the 1024-bit EPROM data field.
After having sent the command code of the Extended Read Memory command, the bus master sends a
two-byte address (TA1=(T7:T0), TA2=(T15:T8)) that indicates a starting byte location within the data
field. By sending eight read data time slots, the master receives the Redirection Byte associated with the
page given by the starting address. With the next sixteen read data time slots, the bus master receives a
16-bit CRC of the command byte, address bytes and the Redirection Byte. This CRC is computed by the
DS2406 and read back by the bus master to check if the command word, starting address and Redirection
Byte were received correctly.
If the CRC read by the bus master is incorrect, a Reset Pulse must be issued and the entire sequence must
be repeated. If the CRC received by the bus master is correct, the bus master issues read time slots and
receives data from the DS2406 starting at the initial address and continuing until the end of a 32-byte
page is reached. At that point the bus master will send sixteen additional read time slots and receive a 16bit CRC that is the result of shifting into the CRC generator all of the data bytes from the initial starting
byte to the last byte of the current page.
With the next 24 read data time slots the master will receive the Redirection Byte of the next page
followed by a 16-bit CRC of the Redirection Byte. After this, data is again read from the 1024-bits
EPROM data field starting at the beginning of the new page. This sequence will continue until the final
page and its accompanying CRC are read by the bus master.
The Extended Read Memory command provides a 16-bit CRC at two locations within the transaction
flow chart: 1) after the Redirection Byte and 2) at the end of each memory page. The CRC at the end of
the memory page is always the result of clearing the CRC generator and shifting in the data bytes
beginning at the first addressed memory location of the EPROM data page until the last byte of this page.
With the initial pass through the Extended Read Memory flow chart the 16-bit CRC value after the
Redirection Byte is the result of shifting the command byte into the cleared CRC generator, followed by
the two address bytes and the Redirection Byte. Subsequent passes through the Extended Read Memory
flow chart will generate a 16-bit CRC that is the result of clearing the CRC generator and then shifting in
the Redirection Byte only. After the 16-bit CRC of the last page is read, the bus master will receive
logical 1s from the DS2406 until a Reset Pulse is issued. The Extended Read Memory command
sequence can be ended at any point by issuing a Reset Pulse.
8 of 31
DS2406
WRITING EPROM MEMORY
The function flow for writing to the Data Memory and Status Memory is almost identical. After the
appropriate write command has been issued, the bus master will send a two-byte starting address
(TA1=(T7:T0), TA2=(T15:T8)) and a byte of data (D7:D0). A 16-bit CRC of the command byte, address
bytes, and data byte is computed by the DS2406 and read back by the bus master to confirm that the
correct command word, starting address, and data byte were received.
If the CRC read by the bus master is incorrect, a Reset Pulse must be issued and the entire sequence must
be repeated. If the CRC received by the bus master is correct, a programming pulse (12V on the 1-Wire
bus for 480 µs) is issued by the bus master. Prior to programming, the entire unprogrammed EPROM
memory field will appear as logical 1s. For each bit in the data byte provided by the bus master that is set
to a logical 0, the corresponding bit in the selected byte of the EPROM memory is programmed to a
logical 0 after the programming pulse has been applied.
After the 480 µs programming pulse is applied and the data line returns to the idle level (5V), the bus
master issues eight read time slots to verify that the appropriate bits have been programmed. The DS2406
responds with the data from the selected EPROM address sent least significant bit first. This byte contains
the bit-wise logical AND of all data ever written to this address. If the EPROM byte contains 1s in bit
positions where the byte issued by the master contained 0s, a Reset Pulse should be issued and the current
byte address should be programmed again. If the DS2406 EPROM byte contains 0s in the same bit
positions as the data byte, the programming was successful and the DS2406 will automatically increment
its address counter to select the next byte in the EPROM memory field. The new two-byte address will
also be loaded into the 16-bit CRC generator as a starting value. The bus master will issue the next byte
of data using eight write time slots.
As the DS2406 receives this byte of data into the scratchpad, it also shifts the data into the CRC generator
that has been preloaded with the current address and the result is a 16-bit CRC of the new data byte and
the new address. After supplying the data byte, the bus master will read this 16-bit CRC from the DS2406
with sixteen read time slots to confirm that the address incremented properly and the data byte was
received correctly. If the CRC is incorrect, a Reset Pulse must be issued and the write sequence must be
restarted. If the CRC is correct, the bus master will issue a programming pulse and the selected byte in
memory will be programmed.
Note that the initial pass through the write flow chart will generate an 16-bit CRC value that is the result
of shifting the command byte into the CRC generator, followed by the two address bytes, and finally the
data byte. Subsequent passes through the write flow chart due to the DS2406 automatically incrementing
its address counter will generate a 16-bit CRC that is the result of loading (not shifting) the new
(incremented) address into the CRC generator and then shifting in the new data byte.
For both of these cases, the decision to continue (to apply a program pulse to the DS2406) is made
entirely by the bus master, since the DS2406 will not be able to determine if the 16-bit CRC calculated by
the bus master agrees with the 16-bit CRC calculated by the DS2406. If an incorrect CRC is ignored and
the bus master applies a program pulse, incorrect programming could occur within the DS2406. Also note
that the DS2406 will always increment its internal address counter after the receipt of the eight read time
slots used to confirm the programming of the selected EPROM byte. The decision to continue is again
made entirely by the bus master. Therefore if the EPROM data byte does not match the supplied data byte
but the master continues with the write command, incorrect programming could occur within the DS2406.
The write command sequence can be ended at any point by issuing a Reset Pulse.
9 of 31
DS2406
Memory Function Flow Chart Figure 7
Bus Master TX Memory
Function Command
F0h
Read Memory
?
A5h
Extended Rd.
Memory
?
Y
N
Y
Bus Master TX
TA1(T7:T0), TA2 (T15:T8)
DS2406 sets Memory
Address = (T15:T0)
Bus Master RX
Redirection Byte
Bus Master RX Data
from Data Memory
Master
TX Reset ?
N
N
End of
Data Mem.
?
Y
Master
TX Reset ?
Y
Bus Master RX CRC16 of Command,
Address, Redir. Byte (1st pass)
CRC16 of Redir. Byte (subs. passes)
Bus Master TX N
Reset Pulse
Bus Master RX Data
from Data Memory
Bus Master RX CRC16 of
Command, Address, Data
Master
TX Reset ?
N
CRC
Correct ?
Y
Y
N
Bus Master
RX "1"s
N
Bus Master TX
TA1(T7:T0), TA2 (T15:T8)
DS2406 sets Memory
Address = (T15:T0)
DS2406
increments
Address
Counter
To Figure 7
2nd Part
Y
DS2406
increments
Address
Counter
Master
TX Reset ?
N
Y
End
of Page ?
N
Y
Bus Master RX CRC16 of
Preceding Page of Data
Legend:
Decision made
by Bus Master
Bus Master TX N
Reset Pulse
Y
End of
Data Mem.
?
Y
Decision made
by DS2406
Vertical
Spare
R
CRC
Correct ?
S
DS2406 TX
Presence Pulse
10 of 31
Y
Master
TX Reset ?
N
DS2406
increments
Address
Counter
N
Bus Master
RX "1"s
DS2406
Memory Function Flow Chart (continued) Figure 7
From Figure 7
1st Part
0Fh
Write Memory
?
55h
Write Status
N
?
Legend:
Y
Bus Master TX
TA1(T7:T0), TA2 (T15:T8)
DS2406 sets Memory
Address = (T15:T0)
Decision made
by Bus Master
Decision made
by DS2406
N
To Figure 7
3rd Part
Y
Bus Master TX
TA1(T7:T0), TA2 (T15:T8)
DS2406 sets Memory
Address = (T15:T0)
Bus Master TX
Data Byte (D7:D0)
Bus Master TX
Data Byte (D7:D0)
Bus Master RX CRC16 of Command,
Address, Data (1st pass); CRC16 of
Address, Data (subsequent passes)
Bus Master RX CRC16 of Command,
Address, Data (1st pass); CRC16 of
Address, Data (subsequent passes)
CRC
Correct ?
N
N
S
Y
R
Bus Master TX
Program Pulse
CRC
Correct ?
Y
N
DS2406 copies Scratchpad to Data EPROM
Bus Master
TX FFh or
Program Pulse
Address < 7
?
Y
Bus Master TX
Program Pulse
Bus Master RX Byte
from Data EPROM
DS2406 copies
Scratchpad to
Volatile Status
DS2406 copies Scratchpad to Status EPROM
Bus Master RX
Byte From
Volatile Status
Bus Master RX Byte
from Status EPROM
N
EPROM
Byte Correct
?
Y
Y
End of
Data Mem.
?
N
DS2406 increments
Address Counter
DS2406 loads new Address
into CRC Generator
N
Bus Master TX
Reset Pulse
EPROM
Byte Correct
?
Y
DS2406 increments
Address Counter
DS2406 TX
Presence Pulse
DS2406 loads new Address
into CRC Generator
Vertical
Spare
11 of 31
DS2406
Memory Function Flow Chart (continued) Figure 7
From Figure 7
2nd Part
AAh
Read Status
F5h
Channel
Access
?
N
?
Y
Bus Master TX
TA1(T7:T0), TA2 (T15:T8)
Y
Bus Master TX Ch.Control Bytes 1, 2
Bus Master TX
Reset Pulse
Bus Master RX
Channel Info Byte
DS2406 TX
Presence Pulse
DS2406 sets Status
Address = (T15:T0)
Y
Bus Master RX Data
from Status Memory
N
Master
TX Reset ?
N
DS2406
increments
Address
Counter
Master
TX Reset ?
N
N
End of
Status Mem.
?
Y
Master
TX Reset ?
Y
Bus Master * Write
TX Data to
Channel F/F
Y
Read
Master
TX Reset ?
Y
R
N
Y
S
N
CRC Due * ?
Bus Master
RX "1"s
Master
TX Reset ?
N
Bus Master *
RX Data
from PIOs
* See Channel
Control Byte 1
and Figure 7A
N
CRC*
Enabled ?
N
Bus Master RX CRC16 of
Command, Address, Data
Access
Mode ?
Y
Y
DS2406
increments
CRC Byte
Counter
Y
Master
TX Reset ?
N
Bus Master RX CRC16 of Command,
Control, Data (1st pass)
CRC16 of Data (subsequent passes)
Y
Master
TX Reset ?
N
DS2406 clears
CRC Byte Counter
Vertical
Spare
DS2406 TX
Presence Pulse
12 of 31
R/W Toggle
Enabled ?
N
Y
DS2406 toggles
R/W Mode
DS2406
Write Memory [0Fh]
The Write Memory command is used to program the 1024-bit EPROM data memory. The details of the
functional flow chart are described in the section “Writing EPROM Memory”. The data memory address
range is 0000h to 007Fh. If the bus master sends a starting address higher than this, the nine most
significant address bits are set to zeros by the internal circuitry of the chip. This will result in a mismatch
between the CRC calculated by the DS2406 and the CRC calculated by the bus master, indicating an error
condition.
Write Status [55h]
The Write Status command is used to program the Status Memory, which includes the specification of the
Conditional Search Settings. The details of the functional flow chart are described in the section “Writing
EPROM Memory”.
The Status Memory address range is 0000h to 0007h. The general programming algorithm is valid for the
EPROM section of the Status Memory (addresses 0 to 4) only. The Status memory locations 5 and 6 are
already pre-programmed to 00h and therefore cannot be altered. Status memory location 7 consists of
static RAM, which can be reprogrammed without limitation and does not require a 12V programming
pulse. The supply indication (bit 7) is read-only; attempts to write to it are ignored. The function flow for
writing to status memory location 7 is basically the same as for the other EPROM Status Memory Bytes.
However, instead of a programming pulse the bus master may send a FFh byte (equivalent to 8 Write-One
Time Slots) to transfer the new value from the scratchpad to the status memory.
If the bus master sends a starting address higher than 0007h, the nine most significant address bits are set
to zeros by the internal circuitry of the chip. The address bits T3:T6 remain unchanged and will be
ignored by the address decoder of the DS2406. Only if one or more of the address bits T8:T15 is set, the
bus master will be able to discover an error condition based on the CRC16 that is calculated by the
DS2406.
Read Status [AAh]
The Read Status command is used to read data from the Status Memory field. The functional flow chart
of this command is identical to the Read Memory command. Since the Status Memory is only 8 bytes, the
DS2406 will send the 16-bit CRC after the last byte of status information has been transmitted.
Channel Access [F5h]
The Channel Access command is used to access the PIO channels to sense the logical status of the output
node and the output transistor and to change the status of the output transistor. The bus master will follow
the command byte with two Channel Control Bytes and will receive back the Channel Info byte. The
Channel Control bytes allow the master to select a PIO-channel to communicate with, to specify
communication parameters, and to reset the activity latches. Figure 8 shows the details Channel Control
Byte 1. The bit assignments of Channel Control Byte 2 are reserved for future development. The bus
master should always send FFh for the second Channel Control Byte.
CHANNEL CONTROL BYTE 1 Figure 8
BIT 7
ALR
BIT 6
IM
BIT 5
TOG
BIT 4
IC
BIT 3
CHS1
13 of 31
BIT 2
CHS0
BIT 1
CRC1
BIT 0
CRC0
DS2406
Most easily understood are the bits CHS0 and CHS1, which select the channels to communicate with.
One can select one of the two channels or both channels together. The selection codes are shown in the
table below.
CHS1
CHS0
Description
0
0
(not allowed)
0
1
channel A only
1
0
channel B only
1
1
both channels interleaved
When reading only a single channel, the logic level at the selected PIO is sampled at the beginning of
each read time slot (Figure 10a) and is immediately signaled through the 1-Wire line. Because the PIO
logic levels are sensed at the beginning of the time slot, the bus master does not see transitions at the PIO
that occur during the time slot. When writing to a single channel, the selected PIO will show the new
status after (but not necessarily immediately after) the 1-Wire line has returned to its idle level of
typically 5V (see Figure 10a). If the bus master transmits a 1 (Write One Time Slot), the output transistor
of the selected channel will change its status after time td1, which is 15µs to 60µs after the beginning of
the time slot. If the bus master transmits a 0 (Write Zero Time Slot), the output transistor will change its
status with a delay of td0 after the 1-Wire line has returned to its idle level. The value of td0 may vary
between 200 and 300 ns (see Figure 10a). Depending on the load conditions, there may be additional
delay until the voltage at the PIO reaches a new logical level.
When communicating with both channels, the Interleave Control Bit IC controls when data is sampled
and when data arrives at the PIO pins. There is an asynchronous mode (IC = 0) and a synchronous mode
(IC = 1). For the asynchronous mode, both channels are accessed in an alternating way. For the synchronous mode, both channels are accessed simultaneously. For single-channel operation the Interleave
Control Bit must be set to 0.
When reading in the asynchronous mode each channel is sampled alternately at the start of each Read
Time Slot, beginning with channel A. The logic level detected at the PIO is immediately transmitted to
the master during the same time slot. When reading in the synchronous mode, both channels will be
sampled at the same time. The data bit from channel A will be sent to the master immediately during the
same time slot while the data bit from channel B follows with the next time slot which does not sample
the PIOs. Both channels will be sampled again with the time slot that follows the transmission of the data
bit from PIO-B (Figure 10b).
When writing in the asynchronous mode, each channel will change its status independently of the other.
The change of status occurs with the same timing relations as for communication with one channel.
However, every second write time slot addresses the same channel. The first time slot is directed to
channel A, the second to channel B, the next to channel A and so on. As a consequence, in asynchronous
mode both PIOs can never change their status at the same time. When writing in the synchronous mode,
both channels operate together. After the new values for both channels have arrived at the DS2406 the
change of status at both channels occurs with the same timing relations as for communication with one
channel. As with the asynchronous mode, every second write time slot contains data for the same
channel. The first time slot addresses channel A, the second channel B and so on. Depending on the data
values, in the synchronous mode both PIOs can change their status at the same time (Figure 10c). In any
of these cases, the information of channel A and channel B will appear alternating on the 1-Wire line,
always starting with channel A. By varying the idle-time between time slots on the 1-Wire line one has
full control over the time points of sampling and the waveforms generated at the PIO-pins when writing
to the device.
14 of 31
DS2406
The TOG bit of Channel Control Byte 1 specifies if one is always reading or writing (TOG = 0) or if one
is going to change from reading to writing or vice versa after every data byte that has been sent to or
received from the DS2406 (TOG = 1). When accessing one channel, one byte is equivalent to eight reads
from or writes to the selected PIO pin. When accessing two channels, one byte is equivalent to four reads
or writes from/to each channel.
The initial mode (reading or writing) for accessing the PIO channels is specified in the IM bit. For reading, IM has to be set to 1, for writing IM needs to be 0. If the TOG bit is set to 0, the device will always
read or write as specified by the IM bit. If TOG is 1, the device will use the setting of IM for the first byte
to be transmitted and will alternate between reading and writing after every byte. Table 1 illustrates the
effect of TOG and IM for one-channel as well as for two-channel operation.
THE EFFECT OF TOGGLE MODE AND INITIAL MODE Table 1
TOG
0
0
1
IM
0
1
0
CHANNELS
one channel
one channel
one channel
1
1
one channel
0
0
1
0
1
0
two channels
two channels
two channels
1
1
two channels
EFFECT
Write all bits to the selected channel
Read all bits from the selected channel
Write 8 bits, read 8 bits, write, read, etc. to/from
the selected channel
Read 8 bits, write 8 bits, read, write, etc. from/to
the selected channel
Repeat: four times (write A, write B)
Repeat: four times (read A, read B)
Four times: (write A, write B), four times: (read
A, read B), write, read, etc.
Four times: (read A, read B), four times: (write A,
write B), read, write, etc.
The ALR bit of Channel Control Byte 1 controls whether the activity latch of each channel gets reset.
Both activity latches are cleared simultaneously if the ALR bit is 1. They are not changed if the ALR bit
is 0. An activity latch is set with a negative or positive edge that occurs at its associated PIO channel.
Channel Control Byte 1 also controls the internal CRC generator to safeguard data transmission between
the bus master and the DS2406 for channel access. It does not affect reading from or writing to the
memory sections of the DS2406. The CRC control bits (bit 0 and bit 1) can be set to create and protect
data packets that have the size of 8 bytes or 32 bytes. If desired, the device can safeguard even single
bytes by a 16-bit CRC. This setting, however, limits the average PIO sampling rate to about one third of
its maximum possible value. The codes for the CRC control are shown in the table below.
CRC1
0
0
1
1
CRC0
0
1
0
1
Description
CRC disabled (no CRC at all)
CRC after every byte
CRC after 8 bytes
CRC after 32 bytes
The CRC provides a high level of safeguarding data. A detailed description of CRCs is found in
Application Note 27. If the CRC is disabled, the CRC-related sections in the flow chart are skipped.
15 of 31
DS2406
After the Channel Control bytes have been transmitted the bus master receives the Channel Info byte
(Figure 9). This byte indicates the status of the channel flip-flops, the PIO pins, the activity latches as
well as the availability of channel B and external power supply. To be able to read from a PIO channel,
the output transistor needs to be non-conducting, which is equivalent to a 1 for the channel flip-flop.
Reading 0 for both the channel flip-flop and the sensed level indicates that the output transistor of the PIO
is pulling the node low. For the Channel Info byte PIO A and B are sampled at the same time, as in the
synchronous mode. If channel B is available, bit 6 of the Channel Info Byte reads 1. For 1-channel
versions of the DS2406, the PIO B sensed level, channel flip-flop value, and activity latch value should
be ignored. Without an external supply, the supply indication bit (bit 7) reads 0. As long as the voltage
applied to the VCC pin is high enough to operate the device this bit will read 1.
CHANNEL INFO BYTE Figure 9
BIT 7
BIT 6
Supply
Number of
Indication Channels
0 = no
0 = channel
supply
A only
BIT 5
PIO-B
Activity
Latch
BIT 4
PIO-A
Activity
Latch
BIT 3
PIO B
Sensed
Level
BIT 2
PIO A
Sensed
Level
BIT 1
BIT 0
PIO-B
PIO-A
Channel
Channel
Flip-Flop Q Flip-Flop Q
ONE-CHANNEL READ/WRITE Figure 10a
READ (IC=0, Asynchronous Mode)
PIO SAMPLING
PIO
1-WIRE
WRITE (IC=0, Asynchronous Mode)
td1
15 µs < td1 < 60 µs
td0
200 ns < td0 < 300 ns
1-WIRE
PIO
TWO-CHANNEL READ Figure 10b
PIO SAMPLING
1
2
3
4
5
6
7
8
9
PIO-A
PIO-B
IC=1, SYNCHRONOUS MODE
1-WIRE
A1
B1
A3
B3
A5
B4
A5
B5
A7
B7
A9
IC=0, ASYNCHRONOUS MODE
1-WIRE
A1
B2
A3
16 of 31
B6
A7
B8
A9
DS2406
TWO-CHANNEL WRITE Figure 10c
td1
1-WIRE
15 µs < td1 < 60 µs
A1
B1
A2
td0
B2
200 ns < td0 < 300 ns
A3
B3
A4
B4
IC=1, SYNCHRONOUS MODE
PIO-A
A1
A2
A3
A4
PIO-B
B1
B2
B3
B4
IC=0, ASYNCHRONOUS MODE
PIO-A
PIO-B
A1
A2
B1
A3
B2
A4
B3
B4
1-WIRE BUS SYSTEM
The 1-Wire bus is a system, which has a single bus master and one or more slaves. In all instances, the
DS2406 is a slave device. The bus master is typically a microcontroller. The discussion of this bus
system is broken down into three topics: hardware configuration, transaction sequence, and 1-Wire
signaling (signal types and timing). A 1-Wire protocol defines bus transactions in terms of the bus state
during specified time slots that are initiated on the falling edge of sync pulses from the bus master.
HARDWARE CONFIGURATION
The 1-Wire bus has only a single line by definition; it is important that each device on the bus be able to
drive it at the appropriate time. To facilitate this, each device attached to the 1-Wire bus must have an
open drain or 3-state outputs. The 1-Wire port of the DS2406 is open drain with an internal circuit
equivalent to that shown in Figure 11. Typical bus master ports are shown in Figure 12. If a bi-directional
pin is not available, separate output and input pins can be tied together. A multidrop bus consists of a 1Wire bus with multiple slaves attached. The 1-Wire bus has a maximum data rate of 16.3kbits/s. For
normal communication excluding EPROM programming the 1-Wire bus requires only a pull-up resistor
of approximately 5kΩ for short line lengths.
The idle state for the 1-Wire bus is high. If, for any reason a transaction needs to be suspended, the bus
MUST be left in the idle state if the transaction is to resume. If this does not occur and the bus is left low
for more than 120µs, one or more of the devices on the bus may be reset. If the 1-Wire bus remains low
for more than 5ms any DS2406 that is not VCC powered may perform a power-on reset and switch off
both PIOs.
TRANSACTION SEQUENCE
The sequence for accessing the DS2406 via the 1-Wire port is as follows:
ƒ Initialization
ƒ ROM Function Command
ƒ Memory or Channel Access Function Command
ƒ Transaction/Data
17 of 31
DS2406
DS2406 EQUIVALENT CIRCUIT Figure 11
PIO Channel
1-Wire Interface
Activity
Latch "1"
DATA
to PIOControl
RX
Q
Edge
Detector
PIO
D
Q
Reset
5 µA
Typ.
10 M Ω
Typ.
TX
D
1-Wire DATA
100 Ω
MOSFET
from PIOControl
Q
R Q
Ground
Ground
Channel
Flip-Flop
BUS MASTER CIRCUIT Figure 12
A) Open Drain
VPUP
12V
VDD
BUS MASTER
DS5000 OR 8051EQUIVALENT
Open Drain
Port Pin
RX
TX
10 k Ω
10 k Ω
S
5 kΩ
VP0300L
OR
VP0106N3
OR
BSS110
D
S
D
2N7000
D
D
PGM
2N7000
S
S
2N7000
470 pF
to data connection
of DS2406
Capacitor added to reduce
coupling on data line due to
programming signal switching
The interface is reduced to the 5k Ω pull-up resistor if one does not intend to program the EPROM cells.
B) Standard TTL
VDD
BUS MASTER
TTL-Equivalent
Port Pins
VPUP
12V
(10 mA min.)
5 kΩ
PROGRAMMING PULSE
RX
to data connection
of DS2406
TX
5 kΩ
The diode and programming circuit are not required if one does not intend to program the EPROM cells.
18 of 31
DS2406
INITIALIZATION
All transactions on the 1-Wire bus begin with an initialization sequence. The initialization sequence
consists of a reset pulse transmitted by the bus master followed by a presence pulse(s) transmitted by the
slave(s). The presence pulse lets the bus master know that the DS2406 is on the bus and is ready to
operate. For more details, see the “1-Wire Signaling” section.
ROM FUNCTION COMMANDS
Once the bus master has detected a presence, it can issue one of the five ROM function commands that
the DS2406 supports. All ROM function commands are 8 bits long. A list of these commands follows
(refer to flowchart in Figure 13).
Read ROM [33h]
This command allows the bus master to read the DS2406’s 8-bit family code, unique 48-bit serial
number, and 8-bit CRC. This command should only be used only if there is a single slave on the bus. If
more than one slave is present on the bus, a data collision will occur when all slaves try to transmit at the
same time (open drain will produce a wired-AND result). The resultant family code and 48-bit serial
number will be invalid.
Match ROM [55h]
The match ROM command, followed by a 64-bit ROM sequence, allows the bus master to address a
specific DS2406 on a multidrop bus. Only the DS2406 that exactly matches the 64-bit ROM sequence
will respond to the subsequent memory function command. All slaves that do not match the 64-bit ROM
sequence will wait for a reset pulse. This command can be used with a single or multiple devices on the
bus.
Search ROM [F0h]
When a system is initially brought up, the bus master might not know the number of devices on the
1-Wire bus or their 64-bit ROM codes. The Search ROM command allows the bus master to use a
process of elimination to identify the 64-bit ROM codes of all slave devices on the bus. The search ROM
process is the repetition of a simple 3-step routine: read a bit, read the complement of the bit, then write
the desired value of that bit. The bus master performs this 3-step routine on each bit of the ROM. After
one complete pass, the bus master knows the 64-bit ROM code of one device. Additional passes will
identify the ROM codes of the remaining devices. See Application Note 187 for a comprehensive
discussion of a search ROM, including an actual example.
Skip ROM [CCh]
This command can save time in a single drop bus system by allowing the bus master to access the
memory and channel access functions without providing the 64-bit ROM code. If more than one slave is
present on the bus and, for example, a read command is issued following the Skip ROM command, data
collision will occur on the bus as multiple slaves transmit simultaneously (open drain pull-downs will
produce a wired-AND result).
19 of 31
DS2406
ROM FUNCTIONS FLOW CHART Figure 13
Bus Master TX
Reset Pulse
DS2406 TX
Presence Pulse
R
Bus Master TX ROM
Function Command
33h
Read ROM
Command
?
Y
N
55h
Match ROM
Command
?
Y
N
F0h
Search ROM
Command
?
Y
N
S
ECh
Conditional
Search
?
Y
Condition
Fulfilled ?
DS2406 TX
Family Code
(1 Byte)
Master TX Bit 0
Bit 0
Match ?
DS2406 TX
Serial Number
(6 Byte)
Master TX Bit 1
Bit 1
Match ?
DS2406 TX
CRC Byte
Master TX Bit 63
DS2406 TX Bit 0
DS2406 TX Bit 0
Master TX Bit 0
Bit 0
Match ?
DS2406 TX Bit 1
DS2406 TX Bit 1
Master TX Bit 1
Bit 1
Match ?
DS2406 TX Bit 63
DS2406 TX Bit 63
Master TX Bit 63
Bit 63
Match ?
Bit 63
Match ?
(See Figure 7)
Bus Master TX Memory
Function Command
DS2406 TX Bit 0
DS2406 TX Bit 0
Master TX Bit 0
Bit 0
Match ?
DS2406 TX Bit 1
DS2406 TX Bit 1
Master TX Bit 1
Bit 1
Match ?
DS2406 TX Bit 63
DS2406 TX Bit 63
Master TX Bit 63
Bit 63
Match ?
R
Vertical
Spare
20 of 31
N
CCh
Skip ROM
Command
?
Y
N
DS2406
Conditional Search ROM [ECh]
The Conditional Search ROM command operates similarly to the Search ROM command except that only
devices fulfilling the specified condition will participate in the search. This command provides an
efficient means for the bus master to identify devices in a multidrop system that have to signal a status
change, e.g. the opening of a window in a building control application.
The condition is specified by the bit functions CSS0 to CSS4 in Status Memory location 7. At power-on
all these bits are 1s. They can be changed by means of the Write Status command. As long as the device
remains powered up, the modified search conditions are available for use at any time. For the conditional
search, one can specify the polarity (HIGH or LOW; CSS0), the source (PIO-pin, channel flip flop or
activity latch; CSS1, CSS2), and the channel of interest (A, B or the logical OR of A, B; CSS3, CSS4).
Table 2 shows all qualifying conditions and the required settings for CSS0 to CSS4.
QUALIFYING CONDITIONS FOR CONDITIONAL SEARCH Table 2
DESCRIPTION
CONDITION
RESERVED
Unconditional
Activity Latch = 0
Activity Latch = 1
Channel FF = 0
(transistor on)
Channel FF = 1
(transistor off)
PIO Low
PIO High
Activity Latch = 0
Activity Latch = 1
Channel FF = 0
(transistor on)
Channel FF = 1
(transistor off)
PIO Low
PIO High
Activity Latch = 0
Activity Latch = 1
Channel FF = 0
(transistor on)
Channel FF = 1
(transistor off)
PIO Low
PIO High
CONDITIONAL SEARCH SELECT CODE
CHANNEL SELECT SOURCE SELECT POLARITY
CHANNEL
CSS4
CSS3
CSS2
CSS1
CSS0
Don’t care
0
0
0/1
neither one
0
0
At least one of these
0
bits needs to be 1
A
0
1
0
1
0
A
0
1
0
1
1
A
0
1
1
0
0
A
0
1
1
0
1
A
A
B
B
B
0
0
1
1
1
1
1
0
0
0
1
1
0
0
1
1
1
1
1
0
0
1
0
1
0
B
1
0
1
0
1
B
B
A or B
A or B
A or B
1
1
1
1
1
0
0
1
1
1
1
1
0
0
1
1
1
1
1
0
0
1
0
1
0
A or B
1
1
1
0
1
A or B
A or B
1
1
1
1
1
1
1
1
0
1
21 of 31
DS2406
The activity latch (Figure 11) captures an event for interrogation by the bus master at a later time. This
way, the bus master needs not interrogate devices continuously. The activity latch is set to 1 with the first
negative or positive edge detected on the associated PIO channel. It can be cleared with the Channel
Access command if the ALR bit of the Channel Control Byte 1 is set. The activity latch is automatically
cleared when the DS2406 powers up. In order to use the activity latch the output transistor of the selected
channel should be non-conducting. Otherwise signals applied to the PIO pin will be shorted to ground by
the low impedance of the output transistor.
The Channel Select bits CSS3 and CSS4 specify the channel of interest. The sampling of the source
within the selected channel will take place on completion of the Conditional Search command byte. The
Channel selection codes are as follows:
CSS4
0
0
1
1
CSS3
0
1
0
1
Channel Selection
neither channel selected
channel A only
channel B only
channel A OR channel B
If both CSS3 and CSS4 are 1, the logical values of the selected signal source of both channels are ORed
and the result is compared to specified polarity. If, for example, the specified polarity is 0, the signal
source of both channels must be 0 for the device to respond to the Conditional Search. If both CSS3 and
CSS4 are 0, neither channel is selected. Under this condition the device will always respond to the
Conditional Search if the polarity bit CSS0 is 0, disregarding the source selection. If neither channel is
selected and CSS0 = 1, the device will only respond to the regular Search ROM command.
The source selection for the Conditional Search is done through the Source Select bits CSS1 and CSS2.
The codes for these bits are as follows:
CSS2
0
0
1
1
CSS1
0
1
0
1
Source Selection
RESERVED
Activity Latch
channel flip flop
PIO Status
The setting CSS1 = 0, CSS2 = 0 is reserved for future use. If programmed with this setting the device
will respond to Conditional Search command as follows: if CSS0 = 0 the device will always respond to a
Conditional Search, if CSS0 = 1 the device will never respond to a conditional search.
The Conditional Search Polarity is specified by CSS0. If CSS0 is 0, the DS2406 will respond to a
Conditional Search command if the status of the selected source for the specified channel is logic 0. If
CSS0 is set to 1, the source level needs to be logic 1.
For 1-channel versions of the DS2406 the channel B input will always be logic 0. For this reason CSS4
should not be set to 1 to avoid unwanted influence from channel B. The bus master can determine the
availability of channel B from bit 6 of the Channel Info byte.
22 of 31
DS2406
1-WIRE SIGNALING
The DS2406 requires strict protocols to ensure data integrity. The protocol consists of five types of
signaling on one line: Reset Sequence with Reset Pulse and Presence Pulse, Write 0, Write 1, Read Data,
and Program Pulse. Except for the presence pulse the bus master initiates all these signals.
The initialization sequence required to begin any communication with the DS2406 is shown in Figure 14.
A reset pulse followed by a presence pulse indicates the DS2406 is ready to send or receive data. The bus
master transmits (TX) a reset pulse (tRSTL, minimum 480µs). The bus master then releases the line and
goes into receive mode (RX). The 1-Wire bus is pulled to a high state via the pull-up resistor. After
detecting the rising edge on the data pin, the DS2406 waits (tPDH, 15-60µs) and then transmits the
presence pulse (tPDL, 60-240µs).
INITIALIZATION PROCEDURE “RESET AND PRESENCE PULSES” Figure 14
MASTER TX
"RESET PULSE"
MASTER RX "PRESENCE PULSE"
tRSTH
VPULLUP
VPULLUP MIN
VIH MIN
VIL MAX
0V
tRSTL
RESISTOR
MASTER
DS2406
*
tR
tPDH
tPDL
480 µs ≤ tRSTL < ∞*
480 µs ≤ tRSTH < ∞ (includes recovery time)
15 µs ≤ tPDH < 60 µs
60 ≤ tPDL < 240 µs
In order not to mask interrupt signaling by other devices on the 1-Wire bus, tRSTL + tR should
always be less than 960µs. In a parasitically powered environment tRSTL should be limited to
maximum 5ms. Otherwise the DS2406 may perform a power-on reset.
READ/WRITE TIME SLOTS
The definitions of write and read time slots are illustrated in Figure 15. The master initiates all time slots
by driving the data line low. The falling edge of the data line synchronizes the DS2406 to the master by
triggering an internal delay circuit. During write time slots, the delay circuit determines when the DS2406
will sample the data line. For a read data time slot, if a “0” is to be transmitted, the delay circuit
determines how long the DS2406 will hold the data line low. If the data bit is a “1”, the DS2406 will not
hold the data line low at all.
23 of 31
DS2406
READ/WRITE TIMING DIAGRAM Figure 15
Write-one Time Slot
tSLOT
VPULLUP
tREC
VPULLUP MIN
VIH MIN
DS2406
Sampling Window
VIL MAX
0V
tLOW1
15µs
60µs
RESISTOR
MASTER
60 µs ≤ tSLOT < 120 µs
1 µs ≤ tLOW1 < 15 µs
1 µs ≤ tREC < ∞
Write-zero Time Slot
tSLOT
VPULLUP
VPULLUP MIN
VIH MIN
DS2406
Sampling Window
VIL MAX
0V
15µs
60µs
t LOW0
RESISTOR
60 µs ≤ tLOW0 < tSLOT < 120 µs
MASTER
1 µs ≤ tREC < ∞
24 of 31
tREC
DS2406
READ/WRITE TIMING DIAGRAM (continued) Figure 15
Read-data Time Slot
tREC
tSLOT
VPULLUP
VPULLUP MIN
VIH MIN
Master
Sampling Window
VIL MAX
0V
tSU
tRELEASE
tLOWR
tRDV
60 µs ≤ tSLOT < 120 µs
RESISTOR
MASTER
DS2406
*
1 µs ≤ tLOWR < 15 µs
0 ≤ tRELEASE < 45 µs
1 µs ≤ tREC < ∞
tRDV = 15 µs
tSU < 1 µs
The optimal sampling point for the master is as close as possible to the end time of the 15μs tRDV
period without exceeding tRDV. For the case of a Read-one time slot, this maximizes the amount
of time for the pull-up resistor to recover the line to a high level. For a Read-zero time slot it
ensures that a read will occur before the fastest 1-Wire devices(s) release the line (tRELEASE = 0).
PROGRAM PULSE
To copy data from the 8-bit scratchpad to the EPROM data or status memory, a program pulse is applied
to the data line after the bus master has confirmed that the CRC for the current byte is correct. During
programming, the bus master controls the transition from a state where the data line is idling high via the
pull-up resistor to a state where the data line is actively driven to a programming voltage of 12V
providing a minimum of 10mA of current to the DS2406. This programming voltage (Figure 16) should
be applied for 480µs, after which the bus master should return the data line to the idle high state. Note
that due to the high voltage programming requirements for any 1-Wire EPROM device, it is not possible
to multi-drop non-EPROM based 1-Wire devices with the DS2406 during programming. An internal
diode within the non-EPROM based 1-Wire devices will attempt to clamp the data line at approximately
8V and could potentially damage these devices.
25 of 31
DS2406
PROGRAM PULSE TIMING DIAGRAM Figure 16
V
PP
V
PULLUP
t
GND
Normal 1-Wire
Communication Ends
> 5 µs
t
DP
t
RP
480 µs
t
PP
FP
> 5 µs
t
Normal 1-Wire
Communication Resumes
DV
LINE TYPE LEGEND:
Bus master active high
(12 V @ 10 mA)
Resistor pull-up
CRC GENERATION
With the DS2406 there are two different types of CRCs (Cyclic Redundancy Checks). One CRC is an
8-bit type. It is computed at the factory and lasered into the most significant byte of the 64-bit ROM. The
8
5
4
equivalent polynomial function of this CRC is X + X + X + 1. To determine whether the ROM data has
been read without error the bus master can compute the CRC value from the first 56 bits of the 64-bit
ROM and compare it to the value read from the DS2406. This 8-bit CRC is received in the true form
(non-inverted) when reading the ROM.
16
The other CRC is a 16-bit type, generated according to the standardized CRC16-polynomial function X
15
2
+ X + X + 1. This CRC is used for error detection when reading Data Memory, Status Memory, or
when communicating with PIO channels. In contrast to the 8-bit CRC, the 16-bit CRC is always returned
in the complemented (inverted) form. A CRC-generator inside the DS2406 chip (Figure 17) will calculate
a new 16-bit CRC as shown in the command flow chart of Figure 7. The bus master may compare the
CRC value read from the device to the one it calculates from the data and decides whether to continue
with an operation or to re-do the function that returned the CRC error.
When reading the data memory of the DS2406 with the Read Memory command, the 16-bit CRC is only
transmitted at the end of the memory. This CRC is generated by clearing the CRC generator, shifting in
the command, low address, high address, and every data byte starting at the first addressed memory
location and continuing until the end of the physical data memory is reached.
When reading the Status Memory, the 16-bit CRC is transmitted at the end of the 8-byte Status Memory
page. The 16-bit CRC will be generated by clearing the CRC generator, shifting in the command byte,
low address, high address, and the data bytes beginning at the first addressed memory location and
continuing until the last byte of the Status Memory is reached.
When reading the data memory of the DS2406 with the Extended Read Memory command, there are two
situations where a 16-bit CRC is generated. One 16-bit CRC follows each Redirection Byte; another
16-bit CRC is transmitted after the last byte of a memory data page is read. The CRC at the end of the
memory page is always the result of clearing the CRC generator and shifting in the data bytes beginning
at the first addressed memory location of the EPROM data page until the last byte of this page. With the
initial pass through the Extended Read Memory flow chart the 16-bit CRC value is the result of shifting
26 of 31
DS2406
the command byte into the cleared CRC generator, followed by the two address bytes and the Redirection
Byte. Subsequent passes through the Extended Read Memory flow chart will generate a 16-bit CRC that
is the result of clearing the CRC generator and then shifting in only the Redirection Byte.
When writing to the DS2406 (either data memory or status memory), the bus master receives a 16-bit
CRC to verify that the data transfer was correct before applying the programming pulse. With the initial
pass through the Write Memory/Status flow chart the 16-bit CRC will be generated by clearing the CRCgenerator, shifting in the command, low address, high address and the data byte. Subsequent passes
through the Write Memory/Status flow chart due to the DS2406 automatically incrementing its address
counter will generate a 16-bit CRC that is the result of loading (not shifting) the new (incremented)
address into the CRC generator and then shifting in the new data byte.
When communicating with a PIO channel using the Channel Access command, one can select whether
and how often a 16-bit CRC will be added to the data stream. This CRC selection is specified in the
Channel Control byte 1 and may be changed with every execution of the Channel Access command.
Depending on the CRC selection, the device can generate a CRC after every byte that follows the
Channel Info byte, after each block of eight bytes or after each block of 32 bytes. If the CRC is enabled,
with the initial pass through the Channel Access flow chart the 16-bit CRC will be generated by clearing
the CRC-generator, shifting in the command, Channel Control Bytes 1 and 2, Channel Info Byte and the
specified amount of data bytes (1, 8, or 32). Subsequent passes through the Channel Access flow chart
will generate a 16-bit CRC that is the result of clearing the CRC generator and then shifting in the new
data byte(s). This algorithm is valid for all accesses to the PIO channels, continuous reading or writing as
well as toggling between read and write.
The comparison of CRC values and decision to continue with an operation are determined entirely by the
bus master. There is no circuitry on the DS2406 that prevents a command sequence from proceeding if a
CRC error occurs. For more details on generating CRC values including example implementations in
both hardware and software, see Application Note 27.
CRC-16 HARDWARE DESCRIPTION AND POLYNOMIAL Figure 17
Polynomial = X16 + X15 + X2 + 1
1ST
STAGE
2ND
STAGE
X0
3RD
STAGE
X1
X2
4TH
STAGE
5TH
STAGE
6TH
STAGE
X3
X4
X5
13TH
STAGE
14TH
STAGE
15TH
STAGE
7TH
STAGE
X6
8TH
STAGE
X7
X8
R
S
9TH
STAGE
X9
10TH
STAGE
11TH
STAGE
X10
12TH
STAGE
X11
X12
X13
X14
16TH
STAGE
X15
INPUT DATA
27 of 31
X16
CRC
OUTPUT
DS2406
ABSOLUTE MAXIMUM RATINGS*
Voltage on DATA or PIO-A to Ground
Voltage on VCC or PIO-B to Ground
Operating Temperature Range
Storage Temperature Range
Soldering Temperature
*
-0.5V to +13.0V
-0.5V to +6.5V
-40°C to +85°C
-55°C to +125°C
See J-STD-020A Specifications
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
DC ELECTRICAL CHARACTERISTICS
DATA PIN
PARAMETER
1-Wire Input High
1-Wire Input Low
1-Wire Output Low @ 4mA
1-Wire Output High
Input Load Current
Programming Voltage @ 10mA
SYMBOL
VIH
VIL
VOL
VOH
IL
VPP
(VPUP=2.8V to 6.0V; -40°C to +85°C)
MIN
2.2
-0.3
VPUP
5
11.5
DC ELECTRICAL CHARACTERISTICS
PIO PINs
PARAMETER
Logic 1 (A)
Logic 0 (A)
Output Sink Current @ 4V (A)
Output Logic High (A)
Logic 1 (B)
Logic 0 (B)
Output Sink Current @ 4V (B)
Output Logic High (B)
Input Resistance
SYMBOL
VIHA
VILA
ISA
VOHA
VIHB
VILB
ISB
VOHB
RI
TYP
MAX
0.8
0.4
6.0
12.0
UNITS
V
V
V
V
µA
V
NOTES
1, 6
1, 13
1
1, 2
3
(VPUP=2.8V to 6.0V; -40°C to +85°C)
MIN
TYP
MAX
2.2
12
-0.3
0.6
See graph on page 30
VPUPA
12.0
2.2
6.0
-0.3
0.4
See graph on page 30
VPUPB
6.0
7
10
13
UNITS
V
V
mA
V
V
V
mA
V
MΩ
NOTES
1, 6
1
11, 12
1, 2
1, 6
1
1, 2
9
DC ELECTRICAL CHARACTERISTICS VCC (VPUP=2.8V to 6.0V; -40°C to +85°C)
PARAMETER
Logic 1
Logic 0
Input Current
SYMBOL
VIHC
VILC
ICC
MIN
2.8
-0.3
28 of 31
TYP
MAX
6.0
0.8
4.0
UNITS
V
V
µA
NOTES
1, 10
1
3
DS2406
CAPACITANCES
PARAMETER
Capacitance DATA Pin
Capacitance PIO-A Pin
Capacitance PIO-B Pin
Capacitance VCC Pin
(tA = 25°C)
SYMBOL
CD
CA
CB
CC
MIN
SYMBOL
tSLOT
tLOW1
tLOW0
tLOWR
tRDV
tRELEASE
tSU
tREC
tRSTH
tRSTL
tPDH
tPDL
tSUA
tSUB
tDP
tDV
tPP
tRP
tFP
MAX
800
100
25
10
AC ELECTRICAL CHARACTERISTICS
PARAMETER
Time Slot
Write 1 Low Time
Write 0 Low Time
Read Low Time
Read Data Valid
Release Time
Read Data Setup 1-Wire
Recovery Time
Reset High Time
Reset Low Time
Presence Detect High
Presence Detect Low
Read Data Setup PIO-A
Read Data Setup PIO-B
Delay to Program
Delay to Verify
Program Pulse Width
Program Voltage Rise Time
Program Voltage Fall Time
TYP
UNITS
pF
pF
pF
pF
NOTES
7
(VPUP=2.8V to 6.0V; -40°C to +85°C)
MIN
60
1
60
1
0
1
480
480
15
60
0.5
0.5
5
5
480
0.5
0.5
Definition of PIO Read Data Setup Time
PIO-A,
PIO-B
1-Wire
t SUA,
t SUB
29 of 31
TYP
15
15
MAX
120
15
120
15
45
1
960
60
240
5000
5.0
5.0
UNITS
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
NOTES
16
16
15
5
4
8
14
DS2406
PIO SINK CURRENT
I SA , I SB
100 mA
@ 0.4V
90 mA
max.
80 mA
70 mA
PIO-A
60 mA
50 mA
40 mA
min.
30 mA
max.
20 mA
PIO-B
10 mA
min.
V PUP
2.8V
4V
5V
6V
NOTES:
1.
2.
3.
4.
5.
All voltages are referenced to ground.
VPUP, VPUPA, VPUPB = external pull-up voltage.
Input load is to ground.
An additional reset or communication sequence cannot begin until the reset high time has expired.
Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1µs of this falling edge and will remain valid for 14µs minimum (15µs
total from falling edge on 1-Wire bus).
6. VIH is a function of the chip-internal supply voltage. This voltage is determined by either the external
pull-up resistor and VPUP or the VCC supply, whichever is higher. Without VCC supply, VIH for either
PIO pin should always be greater than or equal to VPUP -0.3V.
7. Capacitance on the data pin could be 800pF when power is first applied. If a 5kΩ resistor is used to
pull up the data line to VPUP, 5µs after power has been applied the parasite capacitance will not affect
normal communications.
8. The Reset Low Time (tRSTL) should be restricted to a maximum of 960μs to allow interrupt signaling;
otherwise, it could mask or conceal interrupt pulses.
9. Input resistance is to ground.
10. VCC must be at least 4.0V if it is to be connected during a programming pulse.
11. If the current at PIO-A reaches 200mA the gate voltage of the output transistor will be reduced to
limit the sink current to 200mA. The user-supplied circuitry should limit the current flow through the
PIO-transistor to no more than 100mA. Otherwise the DS2406 may be damaged.
12. PIO-A has a controlled turn-on output. The indicated currents are DC values. At VPUP = 4.0V or
higher the sink current typically reaches 80% of its DC value 1 µs after turning on the transistor.
13. Under certain low voltage conditions VILMAX may have to be reduced to as much as 0.5V to always
guarantee a presence pulse.
14. The accumulative duration of the programming pulses for each address must not exceed 5ms.
15. The optimal sampling point for the master is as close as possible to the end time of the 15μs tRDV
period without exceeding tRDV. For the case of a Read-one time slot, this maximizes the amount of
time for the pull-up resistor to recover the line to a high level. For a Read-zero time slot it ensures
that a read will occur before the fastest 1-Wire devices(s) release the line (tRELEASE = 0).
30 of 31
DS2406
16. The duration of the low pulse sent by the master should be a minimum of 1μs with a maximum value
as short as possible to allow time for the pull-up resistor to recover the line to a high level before the
1-Wire device samples in the case of a Write 1 Low Time, or before the master samples in the case of
a Read Low Time.
31 of 31