ETC2 AG9033-S Power-over-ethernet module Datasheet

V2.4 Dec 2006
Data Sheet
Silver
Ag9000-S
TELECOM
Power-Over-Ethernet Module
Pb
1. Features
IEEE802.3af compliant
Small SIL package size - 56mm (L) x
14mm (H)
Low output ripple and noise
Input voltage range 36V to 60V
Only one low cost external
decoupling capacitor required
Overload and short-circuit protection
Adjustable Output
High efficiency DC/DC converter
1500V isolation (input to output)
Silver Telecom “design-in” assistance
2. Description
The Ag9000-S series of modules are designed to extract power from a conventional twisted pair
Category 5 Ethernet cable, conforming to the IEEE 802.3af Power-over-Ethernet (PoE)
standard.
IEEE 802.3af allows for two power options for Category 5 cables and the Ag9000-S series have
two pairs of power inputs pins: - VA1&2 and VB1&2 to accommodate this, see Figure 1.
The Ag9000-S signature and control circuit provides the PoE compatibility signature and power
classification required by the Power Sourcing Equipment (PSE) before applying up to 15W
power to the port. The Ag9000 is compatible with Class 0 to Class 3 equipment.
The high efficiency DC/DC converter operates over a wide input voltage range and provides a
regulated low ripple and low noise output. The DC/DC converter also has built-in overload and
short-circuit output protection.
© Silver Telecom 2006
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
Table of Contents
1. Features...........................................................................................................................1
2. Description.......................................................................................................................1
Table of Contents.............................................................................................................2
Table of Figures ...............................................................................................................2
3. Ag9000-S Product Selector .............................................................................................2
4. Pin Description.................................................................................................................4
5. Functional Description .....................................................................................................5
5.1. Inputs ........................................................................................................................5
5.2. PD Signature.............................................................................................................5
5.3. Isolation.....................................................................................................................5
5.4. Power Classification ..................................................................................................6
5.5. DC/DC Converter ......................................................................................................7
5.6. Output Adjustment.....................................................................................................7
5.7. Typical Connections ..................................................................................................8
6. Typical Application ...........................................................................................................9
7. Typical Recommendations.............................................................................................10
8. Operating Temperature Range ......................................................................................10
9. Electrical Characteristics................................................................................................13
9.1. Absolute Maximum Ratings* ...................................................................................13
9.2. Recommended Operating Conditions .....................................................................13
9.3. DC Electrical Characteristics* .................................................................................13
10. Package.......................................................................................................................14
10.1. Ag9000-S ..............................................................................................................14
Table of Figures
Figure 1: Block Diagram ......................................................................................................3
Figure 2: Ag9000-S Package Format ..................................................................................3
Figure 3: Typical System Diagram.......................................................................................5
Figure 4: Class Programming Option...................................................................................6
Figure 5: Output Adjustment ................................................................................................7
Figure 6: Typical Connection Diagram.................................................................................8
Figure 7: Typical Application................................................................................................9
Figure 8: Typical Layout.....................................................................................................10
Figure 9: Power Plane Heatsink for Ag9000-S ..................................................................11
Figure 10: Ag9033-S Operating Profile ..............................................................................11
Figure 11: Ag9050-S Operating Profile ..............................................................................12
Figure 12: Ag9120-S Operating Profile ..............................................................................12
3. Ag9000-S Product Selector
Part Number†
Ag9120-S
Ag9050-S
Ag9033-S
Nominal Output Voltage
12.0V
5.0V
3.3V
Maximum Output Power *
12 Watts
9 Watts
6 Watts
Marking
12
5
3
*At 25°C with VIN = 48V
† All versions of the Ag9000 are RoHS compliant.
Table 1: Ordering Information
© Silver Telecom 2006
2
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
Ag9000-S
VA1
Input
VA2
VB1
Signature
& Control
Input
DC:DC
Converter
DC
Output
VB2
Figure 1: Block Diagram
1
Figure 2: Ag9000-S Package Format
© Silver Telecom 2006
3
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
4. Pin Description
Pin #
Name
1
VA1
2
VA2
3
VB1
4
VB2
5
CP1
6
CP2
7
GND
8
+VDC
9
ADJ
10
IC
© Silver Telecom 2006
Description
RX Input (1). This input pin is used in conjunction with VA2 and
connects to the centre tap of the transformer connected to pins 1
& 2 of the RJ45 connector (RX) - it is not polarity sensitive.
TX Input (2). This input pin is used in conjunction with VA1 and
connects to the centre tap of the transformer connected to pins 3
& 6 of the RJ45 connector (TX) - it is not polarity sensitive.
Direct Input (1). This input pin is used in conjunction with VB2
and connects to pin 4 & 5 of the RJ45 connector - it is not polarity
sensitive.
Direct Input (2). This input pin is used in conjunction with VB1
and connects to pin 7 & 8 of the RJ45 connector - it is not polarity
sensitive.
Class Programming (1). Connect an external resistor to CP2 will
change the current class of the module. With no resistor fitted the
Ag9000 will default to Class 0.
Class Programming (2). Connect an external resistor to CP1 will
change the current class of the module. With no resistor fitted the
Ag9000 will default to Class 0.
Ground. The ground return for the +VDC output.
DC Output. This pin provides the regulated output from the
DC/DC converter.
Output Adjust. The output voltage can be adjusted from is
nominal value, by connecting an external resistor from this pin to
either the +VDC pin or the GND pin.
Internal Connection. Do not connect to this pin.
4
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
5. Functional Description
5.1. Inputs
The Ag9000-S has two internal bridge rectifiers (see Figure 1: Block Diagram) connected
to the VA1-VA2 and the VB1-VB2 inputs. This allows the Ag9000-S to be compatible with
equipment that use the different power options, see Figure 3: Typical System Diagram. It
is important that the PSE does not apply power to the VA and VB outputs at the same time
(Refer to IEEE802.3af for more information).
POWER SOURCING
EQUIPMENT (PSE)
POWERED DEVICE
(PD)
4
4
5
5
1
1
+
+/-
TX
RX
PSE
(48V)
2
2
3
3
6
6
7
7
8
8
*
*
VA1 VB1
DC
OUTPUT
Ag9000-S
RX
TX
VA2 VB2
*
*
+/-
* The VA and VB inputs must not be used at the same time
Figure 3: Typical System Diagram
5.2. PD Signature
When the Ag9000-S is connected to the Cat 5e cable, it will automatically present a
Powered Device (PD) signature to the Power Sourcing Equipment (PSE) or Midspan
Equipment, when requested. The equipment will then recognise that a powered device is
connected to that line and supply power.
5.3. Isolation
To meet the safety isolation requirements of IEEE802.3af section 33.4.1 a Powered
Device (PD) must pass the electrical strength test of IEC 60950 sub clause 6.2. This calls
for either a) 1500VAC test or b) 1500V impulse test. The Ag9000-S is specified to meet
the 1500V impulse test.
© Silver Telecom 2006
5
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
5.4. Power Classification
This is optional from the PSE and is used for power management. The Ag9000-S allows
the current class to be externally programmed by connecting a resistor between the CP1
and CP2 pins, see Figure 4: Class Programming Option. If no resistor is fitted the Ag9000S will default to Class 0, a full list of programming resistor values are shown in Table 2:
Class Programming.
CLASS
0
1
2
3
4
Programming
Resistance (Ohms)
Do not fit
698
383
243
TBD
Min Power
(W)
0.44
0.44
3.84
6.49
Reserved
Max Power
(W)
12.95
3.84
6.49
12.95
Reserved
Table 2: Class Programming
Ag9000-S
CP1
R
CP2
Class Programming
option
Figure 4: Class Programming Option
© Silver Telecom 2006
6
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
5.5. DC/DC Converter
The Ag9000-S’s DC/DC converter provides a regulated low ripple and low noise output,
that has built-in overload and short-circuit output protection - see Table 1: Ordering
Information for voltage and power ratings.
5.6. Output Adjustment
The Ag9000-S has an ADJ pin, which allows the output voltage to be increased or
decreased from its nominal value.
Figure 5: Output Adjustment shows how the ADJ pin is connected: -
Ag9000-S
Ag9000-S
+VDC
+VDC
R
ADJ
ADJ
R
GND
Reducing the output
voltage from nominal
GND
Increasing the output
voltage from nominal
Figure 5: Output Adjustment
Reducing the output voltage, connect R between ADJ and +VDC
Value of R
Ag9033-S output
Ag9050-S output
Ag9120-S output
Open Circuit
3.30V
5.00V
12.00V
100k Ohms
3.25V
4.75V
10.00V
0 Ohms
3.10V
4.50V
9.00V
Increasing the output voltage, connect R between ADJ and GND
Value of R
Ag9033-S output
Ag9050-S output
Ag9120-S output
Open Circuit
3.30V
5.00V
12.00V
100k Ohms
3.40V
5.25V
12.75V
0 Ohms
4.70V
5.50V
13.15V
Table 3: Output Adjustment Resistor (R) Value
© Silver Telecom 2006
7
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
5.7. Typical Connections
The Ag9000-S only requires one external component as shown in Figure 6: Typical
Connection Diagram, a minimum of 470µF is recommended.
The value of C1 will be related to the maximum load step change that the output needs to
drive. For example, in an application were the output needs to cope with a 1.8 Amp load
step change, a minimum of 1000µF should be used. This can be a standard low cost
electrolytic and does not need to be a low ESR type.
Figure 6 shows a 16V capacitor that would cover all product variants up to and including
the Ag9120-S, see Table 1: Ordering Information.
The Class programming and the Output Adjust inputs are optional and are provided to give
great flexibility to the Ag9000-S product range. Further information on using these inputs
can be found in sections 5.4. Power Classification and 5.6. Output Adjustment.
RJ-45
4
VB1
5
Ag9000-S
7
VB2
ADJ
8
VA1
+VDC
1
RX
+
Output
C1
470µF 16V
2
VA2
GND
3
TX
6
CP1
CP2
Figure 6: Typical Connection Diagram
© Silver Telecom 2006
8
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
6. Typical Application
The Ag9000-S can be used in numerous applications. In the example shown in Figure 7:
Typical Application, the data outputs from the switch are connected to the inputs of a
midspan. The midspan will then add power (to the data) on each output that supports
Power over Ethernet (PoE).
In this example port 1 is connected to an ethernet camera and port 2 is connected to a
wireless access point, both of these devices have a built-in Ag9000-S. When the midspan
is switched on (or when the device is connected), the midspan will check each output for a
PoE signature. On ports 1 and 2 the Ag9000-S will identify themselves as PoE enabled
devices and the midspan will supply both data and power to these peripherals.
The other ports (shown in this example) will not have a PoE signature and the midspan will
only pass the data through to these peripherals. The midspan will continuously monitor
each output to see if a PoE enabled device has been added or removed.
8
1
Switch
Patch Cables
8
1 Midspan Equipment
Ethernet
Camera
Ag9000-S
Wireless
Access Point
PC's and other non
PoE peripherals
Figure 7: Typical Application
© Silver Telecom 2006
9
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
7. Typical Recommendations
Figure 8: Typical Layout gives an example of the tracking needed for the Ag9000-S. R1,
R2 and R3 are optional components, but C1 needs to be positioned close to the output
pins of the Ag9000-S as possible to minimise the current loop. The thermal performance of
the Ag9000-S can be improved by increasing the surface area of the output tracks (+VDC
and GND) this is not applicable if the Ag9000-S is in a socket.
ADJ
R2 R3
CLASS
R1
+
_
Ag9000-S
1
*
*
VA & VB
Inputs
Output
C1 Voltage
* Heat dissipation of the Ag9000C-S can be improved by increasing the surface area of the +VDC and GND output tracks.
Figure 8: Typical Layout
8. Operating Temperature Range
Because the Ag9000-S is a power component, it will generate heat, so it is important that
this be taken into consideration at the design stage.
The heart of the Ag9000-S is a DC/DC converter, which like any other power supply will
generate heat. The amount of heat generated by the module will depend on the load it is
required to drive and the input voltage supplied by the PSE. The information shown within
this section of datasheet is referenced to a nominal 48Vdc input voltage supplied by the
PSE.
The Ag9000-S has a maximum ambient operating temperature of 70 OC see Figure 10,
Figure 11 & Figure 12. These results are in still air without any heatsinking, the
performance of the Ag9000-S can be improved by forcing the airflow over the part or by
using a heatsink (see the Ag9000-S application note on heatsinking for more information).
The output stage of the Ag9000-S has a built-in thermal protection circuit, to prevent the
module from being damaged if operated beyond its power / temperature specification.
Because each application is different it is impossible to give fixed and absolute thermal
recommendations. However it is important that any enclosure used has sufficient
ventilation for the Ag9000-S and a direct airflow if possible.
© Silver Telecom 2006
10
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
One simple method for drawing some of the heat away from the Ag9000-S is shown in
Figure 9. Power planes connected to the +VDC and GND pins of the Ag9000-S can be
used to draw heat away from the DC/DC converter via the output pins.
These power planes must be on the outer layers of the PCB and the Ag9000-S must not
be fitted into a socket.
Power
Plane
ADJ
R2 R3
_
+
Ag9000-S
1
C1
VA & VB R1
Inputs CLASS
+VDC
GND
Output
Voltage
Figure 9: Power Plane Heatsink for Ag9000-S
Figure 10, Figure 11 & Figure 12 show the maximum ambient temperature under different
load conditions. These figure have been recorded in a sealed enclosure (in still air) using a
heater element to elevate the ambient temperature (within the enclosure).
6
5
Output Power (W)
4
3
2
1
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperaure (°C)
Figure 10: Ag9033-S Operating Profile
© Silver Telecom 2006
11
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
9
Output Power (W)
8
7
6
5
4
3
2
1
-20
-10
0
10
20
30
40
50
60
70
60
70
Ambient Temperaure (°C)
Figure 11: Ag9050-S Operating Profile
12
11
Output Power (W)
10
9
8
7
6
5
4
3
2
1
-20
-10
0
10
20
30
40
50
Ambient Temperaure (°C)
Figure 12: Ag9120-S Operating Profile
© Silver Telecom 2006
12
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
9. Electrical Characteristics
9.1. Absolute Maximum Ratings*
Parameter
1
DC Supply Voltage
2
DC Supply Voltage Surge for 1ms
3
Storage Temperature
Symbol
Min
Max
Units
VCC
-0.3
60
V
VSURGE
-0.6
80
V
TS
-40
+100
O
C
*Exceeding the above ratings may cause permanent damage to the product. Functional operation under these conditions is not implied.
Maximum ratings assume free airflow.
9.2. Recommended Operating Conditions
Parameter
Symbol
Min
Typ
Max
Units
48
60
V
36
V
70†
Ta / OC
1
Input Supply Voltage ‡
VIN
36
2
Under Voltage Lockout
VLOCK
30
3
Operating Temperature
TOP
-20
25
†See Section 8. Operating Temperature Range
‡With minimum load
9.3. DC Electrical Characteristics*
1
DC Characteristic
Sym
Nominal Output Voltage
+VDC
Min
Typ*
Max
Units
1.8
1.8
1
V
V
V
A
A
A
Test
Comments
Ag9033-S
Ag9050-S
Ag9120-S
Ag9033-S
Ag9050-S
Ag9120-S
3.3
5
12
2
Output Current (VIN = 48V)
PWR
3
Line Regulation
VLINE
0.1
%
@ 50% Load
4
Load Regulation
VLOAD
0.5
%
@ VIN=48V
5
Output Ripple and Noise
VRN
100
mVp-p
6
Minimum Load
7
Short-Circuit Duration
TSC
8
Efficiency
EFF
9
Isolation Voltage (I/O)
VISO
10
Temperature Coefficient
TC
RLOAD
100
mA
∞
75
sec
%
1500
0.02
@ Max load †
for specified
regulation ‡
Continuous @
50 OC, VIN=48V
Ag9050-S @
50% Load
VDC
%
Per OC
*Typical figures are at 25°C with a nominal 48V supply and are for design aid only. Not Guaranteed
†The output ripple and noise can be reduced with an external filter, see application note.
‡Can be used with no load at reduced voltage regulation.
© Silver Telecom 2006
13
Ag9000-S
V2.4 Dec 2006
Data Sheet
Power-Over-Ethernet Module
10. Package
10.1. Ag9000-S
56.0
14.0
18.0 (max)
Ag9000-S
1
3.0
0.6 ± 0.05
1.8 ± 0.25 2.54 ± 0.05
7.0 (max)
30.48 ± 0.25
0.6 ± 0.05
(Recommended PCB hole diameter = 1.1 ± 0.05)
Dimensions (in mm) are nominal unless otherwise stated
© Silver Telecom 2006