TI INA211 High-or low-side measurement, bi-directional current/power monitor with i2c interface Datasheet

INA226
SBOS547 – JUNE 2011
www.ti.com
High-or Low-Side Measurement,
Bi-Directional CURRENT/POWER MONITOR with I2C™ Interface
Check for Samples: INA226
FEATURES
DESCRIPTION
•
•
•
•
The INA226 is a current shunt and power monitor
with an I2C interface. The INA226 monitors both a
shunt voltage drop and bus supply voltage.
Programmable calibration value, conversion times,
and averaging, combined with an internal multiplier,
enable direct readouts of current in amperes and
power in watts.
1
23
•
•
•
•
SENSES BUS VOLTAGES FROM 0V TO +36V
HIGH- OR LOW-SIDE SENSING
REPORTS CURRENT, VOLTAGE, AND POWER
HIGH ACCURACY:
– 0.1% Gain Error (Max)
– 10μV Offset (Max)
CONFIGURABLE AVERAGING OPTIONS
16 PROGRAMMABLE ADDRESSES
OPERATES FROM 2.7 to 5.5V POWER SUPPLY
MSOP-10 PACKAGE
APPLICATIONS
•
•
•
•
•
•
•
SERVERS
TELECOM EQUIPMENT
COMPUTERS
POWER MANAGEMENT
BATTERY CHARGERS
POWER SUPPLIES
TEST EQUIPMENT
The INA226 senses current on buses that can vary
from 0V to +36V, while the device obtains its power
from a single +2.7V to +5.5V supply, drawing a
typical of 330μA of supply current. The INA226 is
specified over the operating temperature range
of –40°C to +125°C. The I2C interface features 16
programmable addresses.
RELATED PRODUCTS
DESCRIPTION
INA209
Zerø-Drift, Low-Cost, Analog Current Shunt Monitor
Series in Small Package
INA210, INA211,
INA212, INA213,
INA214
Zerø-Drift, Bi-Directional Current Power Monitor with
Two-Wire Interface
INA219
High or Low Side, Bi-Directional Current/Power
Monitor with Two-Wire Interface
INA220
Power Supply
(0V to 36V)
HighSide
Shunt
DEVICE
Current/Power Monitor with Watchdog, Peak-Hold,
and Fast Comparator Functions
CBYPASS
0.1mF
VS
(Supply Voltage)
VBUS
INA226
SDA
SCL
´
Load
Power Register
V
2
Current Register
ADC
LowSide
Shunt
I
Voltage Register
IC
Interface
Alert
A0
Alert Register
A1
GND
High-or Low-Side Sensing
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
I C is a trademark of NXP Semiconductors.
All other trademarks are the property of their respective owners.
2
2
3
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2011, Texas Instruments Incorporated
INA226
SBOS547 – JUNE 2011
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
PACKAGING INFORMATION (1)
(1)
PRODUCT
PACKAGE-LEAD
PACKAGE DESIGNATOR
PACKAGE MARKING
INA226AIDGS
MSOP-10
DGS
226
For the most current package and ordering information see the Package Option Addendum at the end of this document, or see the
INA226 product folder at www.ti.com.
ABSOLUTE MAXIMUM RATINGS (1)
Over operating free-air temperature range (unless otherwise noted).
Supply Voltage, VS
INA226
UNIT
6
V
Differential (VIN+) – (VIN–) (2)
–40 to +40
V
Common-Mode
–0.3 to +40
V
SDA
GND – 0.3 to +6
V
SCL
Analog Inputs,
VIN+, VIN–
GND – 0.3 to VS + 0.3
V
Input Current Into Any Pin
5
mA
Open-Drain Digital Output Current
10
mA
Storage Temperature
–65 to +150
°C
Junction Temperature
+150
°C
Human Body Model (HBM)
2500
V
Charged-Device Model (CDM)
1000
V
Machine Model (MM)
150
V
ESD Ratings
(1)
(2)
2
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
VIN+ and VIN– may have a differential voltage of –40V to +40V; however, the voltage at these pins must not exceed the range –0.3V to
+40V.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
ELECTRICAL CHARACTERISTICS: VS = +3.3V
Boldface limits apply over the specified temperature range, TA = –40°C to +125°C.
At TA = +25°C, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 0mV, VBUS = 12V, unless otherwise noted.
INA226
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNIT
INPUT
Shunt voltage input range
-81.9175
81.92
Bus voltage input range (1)
0
36
Common-mode rejection
Shunt offset voltage, RTI (2)
CMRR
VIN+ = 0V to +36V
126
VOS
vs Temperature
vs Power supply
Bus offset voltage, RTI (2)
PSRR
VS = +2.7V to +5.5V
vs Power supply
V
140
dB
±2.5
±10
μV
0.02
0.1
μV/°C
μV/V
2.5
VOS
vs Temperature
Input bias current
mV
±1.25
±7.5
10
40
mV
μV/°C
PSRR
0.5
mV/V
IIN+, IIN-
10
μA
830
kΩ
VBUS input impedance
Input leakage (3)
(VIN+ Pin) + (VIN– Pin),
Power-down mode
0.1
Shunt voltage
2.5
μV
Bus voltage
1.25
mV
μA
0.5
DC ACCURACY
ADC native resolution
1 LSB step size
16
Shunt voltage gain error
vs Temperature
Bus voltage gain error
vs Temperature
0.02
0.1
%
10
50
ppm/°C
0.02
0.1
%
10
50
ppm/°C
±0.1
Differential nonlinearity
ADC conversion time
Bits
LSB
CT bit = 000
140
154
μs
CT bit = 001
204
224
μs
CT bit = 010
332
365
μs
CT bit = 011
588
646
μs
CT bit = 100
1.1
1.21
ms
CT bit = 101
2.116
2.328
ms
CT bit = 110
4.156
4.572
ms
CT bit = 111
8.244
9.068
ms
28
35
ms
SMBus
SMBus timeout (4)
DIGITAL INPUT/OUTPUT
Input capacitance
Leakage input current
3
0 ≤ VIN ≤ VS
0.1
pF
1
μA
Input logic levels:
VIH
0.7(VS)
6
V
VIL
–0.5
0.3(VS)
V
Output logic level
VOL SDA, alert
IOL = 3mA
Hysteresis
(1)
(2)
(3)
(4)
0
0.4
500
V
mV
While the input range is 36V, the full-scale range of the ADC scaling is 40.96V. See the Basic ADC Functions section. Do not apply
more than 36V.
RTI = Referred-to-input.
Input leakage is positive (current flowing into the pin) for the conditions shown at the top of this table. Negative leakage currents can
occur under different input conditions.
SMBus timeout in the INA226 resets the interface any time SCL is low for more than 28ms.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
3
INA226
SBOS547 – JUNE 2011
www.ti.com
ELECTRICAL CHARACTERISTICS: VS = +3.3V (continued)
Boldface limits apply over the specified temperature range, TA = –40°C to +125°C.
At TA = +25°C, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 0mV, VBUS = 12V, unless otherwise noted.
INA226
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNIT
POWER SUPPLY
Operating supply range
+5.5
V
Quiescent current
+2.7
330
420
μA
Quiescent current, power-down mode
0.5
2
μA
Power-on reset threshold
2
V
TEMPERATURE RANGE
–40
Specified range
+125
°C
THERMAL INFORMATION
INA226
THERMAL METRIC (1)
DGS
UNITS
10 PINS
θJA
Junction-to-ambient thermal resistance
171.4
θJCtop
Junction-to-case (top) thermal resistance
42.9
θJB
Junction-to-board thermal resistance
91.8
ψJT
Junction-to-top characterization parameter
1.5
ψJB
Junction-to-board characterization parameter
90.2
θJCbot
Junction-to-case (bottom) thermal resistance
n/a
(1)
4
°C/W
For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
PIN CONFIGURATIONS
DGS PACKAGE
MSOP-10
(Top View)
A1
1
10 VIN+
A0
2
9
VIN-
Alert
3
8
VBUS
SDA
4
7
GND
SCL
5
6
VS+
PIN DESCRIPTIONS
MSOP-10
(DGS)
PIN NO
NAME
1
A1
Address pin. Connect to GND, SCL, SDA, or VS. Table 7 shows pin settings and corresponding addresses.
DESCRIPTION
2
A0
Address pin. Connect to GND, SCL, SDA, or VS. Table 7 shows pin settings and corresponding addresses.
3
Alert
Multi-functional alert, open-drain output.
4
SDA
Serial bus data line, open-drain input/output.
5
SCL
Serial bus clock line, open-drain input.
6
VS+
Power supply, 2.7V to 5.5V.
7
GND
Ground.
8
VBUS
Bus voltage input.
9
VIN–
Negative differential shunt voltage. Connect to negative side of shunt resistor.
10
VIN+
Positive differential shunt voltage. Connect to positive side of shunt resistor.
REGISTER BLOCK DIAGRAM
Power
(1)
Bus Voltage
(1)
´
Current
Shunt Voltage
Channel
(1)
ADC
Bus Voltage
Channel
Calibration
(2)
´
Shunt Voltage
(1)
Data Registers
(1)
Read-only
(2)
Read/write
Figure 1. INA226 Register Block Diagram
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
5
INA226
SBOS547 – JUNE 2011
www.ti.com
TYPICAL CHARACTERISTICS
At TA = +25°C, VS = +3.3V, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 0mV, VBUS = 12V, unless otherwise noted.
SHUNT INPUT OFFSET VOLTAGE
PRODUCTION DISTRIBUTION
FREQUENCY RESPONSE
0
−10
Population
Gain (dB)
−20
−30
−40
G001
10
8
6
4
Input Offset Voltage (mV)
Figure 2.
Figure 3.
SHUNT INPUT OFFSET VOLTAGE
vs TEMPERATURE
SHUNT INPUT COMMON-MODE REJECTION RATIO
vs TEMPERATURE
−1
Common−Mode Rejection Ratio (dB)
170
−1.2
−1.4
Offset (µV)
2
100k
0
10k
-2
100
1k
Frequency (Hz)
-4
10
-6
1
-10
−60
-8
−50
−1.6
−1.8
−2
−2.2
−2.4
−50
−25
0
25
50
Temperature (°C)
75
100
160
150
140
−50
125
−25
0
G003
Figure 4.
25
50
Temperature (°C)
75
100
125
G004
Figure 5.
SHUNT INPUT GAIN ERROR PRODUCTION DISTRIBUTION
SHUNT INPUT GAIN ERROR vs TEMPERATURE
600
Population
Gain Error (m%)
500
400
300
200
100
80
60
40
20
0
-20
-40
-60
-80
-100
100
0
−50
−25
0
25
50
Temperature (°C)
75
100
125
G007
Input Gain Error (m%)
Figure 6.
6
Figure 7.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
TYPICAL CHARACTERISTICS (continued)
At TA = +25°C, VS = +3.3V, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 0mV, VBUS = 12V, unless otherwise noted.
SHUNT INPUT GAIN ERROR
vs COMMON-MODE VOLTAGE
BUS INPUT OFFSET VOLTAGE
PRODUCTION DISTRIBUTION
300
200
Population
Gain Error (m%)
250
150
100
50
G008
7.5
6
4.5
3
1.5
36
0
32
-1.5
8
12
16
20
24
28
Common−Mode Input Voltage (V)
-3
4
-4.5
0
-7.5
−50
-6
0
Input Offset Voltage (mV)
Figure 8.
Figure 9.
BUS INPUT OFFSET VOLTAGE vs TEMPERATURE
BUS INPUT GAIN ERROR PRODUCTION DISTRIBUTION
−0.6
Population
Offset (mV)
−0.8
−1.0
G009
100
80
60
40
125
20
100
0
75
-20
25
50
Temperature (°C)
-40
0
-60
−25
-100
−1.4
−50
-80
−1.2
Input Gain Error (m%)
Figure 10.
Figure 11.
BUS INPUT GAIN ERROR vs TEMPERATURE
INPUT BIAS CURRENT vs COMMON-MODE VOLTAGE
600
25
Input Bias Current (µA)
Gain Error (m%)
500
400
300
200
100
0
−50
−25
0
25
50
Temperature (°C)
75
100
125
20
15
10
5
0
0
G012
Figure 12.
4
8
12
16
20
24
28
Common−Mode Input Voltage (V)
32
36
G012
Figure 13.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
7
INA226
SBOS547 – JUNE 2011
www.ti.com
TYPICAL CHARACTERISTICS (continued)
At TA = +25°C, VS = +3.3V, VIN+ = 12V, VSENSE = (VIN+ – VIN–) = 0mV, VBUS = 12V, unless otherwise noted.
INPUT BIAS CURRENT vs TEMPERATURE
INPUT BIAS CURRENT vs TEMPERATURE, SHUTDOWN
260
Input Bias Current − Shutdown (nA)
Input Bias Current (µA)
24
22
20
18
16
−50
−25
0
25
50
Temperature (°C)
75
100
220
180
140
100
60
20
−50
125
−25
0
G013
Figure 14.
ACTIVE IQ vs TEMPERATURE
100
125
G014
SHUTDOWN IQ vs TEMPERATURE
1.2
Quiescent Current − Shutdown (µA)
Quiescent Current (µA)
75
Figure 15.
500
400
300
200
100
−50
25
50
Temperature (°C)
−25
0
25
50
Temperature (°C)
75
100
1
0.8
0.6
0.4
0.2
−50
125
−25
0
G015
25
50
Temperature (°C)
75
100
125
G016
Figure 16.
Figure 17.
ACTIVE IQ vs I2C CLOCK FREQUENCY
SHUTDOWN IQ vs I2C CLOCK FREQUENCY
500
300
250
Shutdown IQ (mA)
IQ (mA)
450
400
200
150
100
350
50
300
0
1
8
10
100
1,000
10,000
1
10
100
Frequency (kHz)
Frequency (kHz)
Figure 18.
Figure 19.
Submit Documentation Feedback
1,000
10,000
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
APPLICATION INFORMATION
The INA226 is a digital current shunt monitor with an I2C- and SMBus-compatible interface. It provides digital
current, voltage, and power readings necessary for accurate decision-making in precisely-controlled systems.
Programmable registers allow flexible configuration for measurement resolution as well as
continuous-versus-triggered operation. Detailed register information appears at the end of this data sheet,
beginning with Table 2. See the Register Block Diagram for a block diagram of the INA226.
INA226 TYPICAL APPLICATION
The front-page figure shows a typical application circuit for the INA226. Use a 0.1μF ceramic capacitor for
power-supply bypassing, placed as closely as possible to the supply and ground pins.
BASIC ADC FUNCTIONS
The INA226 performs two measurements on the power-supply bus of interest. The voltage developed from the
load current that flows through a shunt resistor creates a shunt voltage that is measured at the VIN+ and VIN–
pins. The device can also measure the power supply bus voltage by connecting this voltage to the VBUS pin. The
differential shunt voltage is measured with respect to the VIN– pin while the bus voltage is measured with
respect to ground.
The INA226 is typically powered by a separate supply that can range from 2.7V to 5.5V. The bus that is being
monitored can range in voltage from 0V to 36V. It is important to note here that based on the fixed 1.25mV LSB
for the bus voltage register that a full-scale register would result in a 40.96V value. The actual voltage that is
applied to the input pins of the INA226 should not exceed 36V. There are no special considerations for
power-supply sequencing because the common-mode input range and power-supply voltage are independent of
each other; therefore, the bus voltage can be present with the supply voltage off, and vice-versa.
As noted, the INA226 takes two measurements, shunt voltage and bus voltage. It then converts these
measurements to current, based on the Calibration Register value, and then calculates power. Refer to the
Configure/Measure/Calculate Example section for additional information on programming the Calibration
Register.
The INA226 has two operating modes, continuous and triggered, that determine how the ADC operates following
these conversions. When the INA226 is in the normal operating mode (that is, MODE bits of the Configuration
Register are set to '111'), it continuously converts a shunt voltage reading followed by a bus voltage reading.
After the shunt voltage reading, the current value is calculated (based on Equation 3). This current value is then
used to calculate the power result (using Equation 4). These values are subsequently stored in an accumulator,
and the measurement/calculation sequence repeats until the number of averages set in the Configuration
Register is reached. Following every sequence, the present set of values measured and calculated are
appended to previously collected values. Once all of the averaging has been completed, the final values for
shunt voltage, bus voltage, current, and power are updated in the corresponding registers that can then be read.
These values remain in the data output registers until they are replaced by the next fully completed conversion
results. Reading the data output registers does not affect a conversion in progress.
The Mode control in the Configuration Register also permits selecting modes to convert only the shunt voltage or
the bus voltage in order to further allow the user to configure the monitoring function to fit the specific application
requirements.
All current and power calculations are performed in the background and do not contribute to conversion time.
In triggered mode, writing any of the triggered convert modes into the Configuration Register (that is, MODE bits
of the Configuration Register are set to ‘001’, ‘010’, or ‘011’) triggers a single-shot conversion. This action
produces a single set of measurements; thus, to trigger another single-shot conversion, the Configuration
Register must be written to a second time, even if the mode does not change.
In addition to the two operating modes (continuous and triggered), the INA226 also has a power-down mode that
reduces the quiescent current and turns off current into the INA226 inputs, reducing the impact of supply drain
when the device is not being used. Full recovery from power-down mode requires 40ms. The registers of the
INA226 can be written to and read from while the device is in power-down mode. The device remains in
power-down mode until one of the active modes settings are written into the Configuration Register.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
9
INA226
SBOS547 – JUNE 2011
www.ti.com
Although the INA226 can be read at any time, and the data from the last conversion remain available, the
Conversion Ready Flag bit (Mask/Enable Register, CVRF bit) is provided to help coordinate one-shot or triggered
conversions. The Conversion Ready Flag bit is set after all conversions, averaging, and multiplication operations
are complete.
The Conversion Ready Flag bit clears under these conditions:
1. Writing to the Configuration Register, except when configuring the MODE bits for power-down mode; or
2. Reading the Status Register.
Power Calculation
The Current and Power are calculated following shunt voltage and bus voltage measurements as shown in
Figure 20. Current is calculated following a shunt voltage measurement based on the value set in the Calibration
Register. If there is no value loaded into the Calibration Register, the current value stored is zero. Power is
calculated following the bus voltage measurement based on the previous current calculation and bus voltage
measurement. If there is no value loaded in the Calibration Register, the power value stored is also zero. Again,
these calculations are performed in the background and do not add to the overall conversion time. These current
and power values are considered intermediate results (unless the averaging is set to 1) and are stored in an
internal accumulation register, not the corresponding output registers. Following every measured sample, the
newly-calculated values for current and power are appended to this accumulation register until all of the samples
have been measured and averaged based on the number of averages set in the Configuration Register.
Bus and Power Limit Detect
Following Every Bus Voltage Conversion
Current Limit Detect Following
Every Shunt Voltage Conversion
I
V
I
P
V
I
P
V
I
P
V
I
P
V
I
P
V
I
P
V
I
P
V
I
P
V
I
V
P
I
P
V
I
P
V
I
P
V
I
P
V
I
P
V
I
P
V
P
Power Average
Bus Voltage Average
Shunt Voltage Average
Figure 20. Power Calculation Scheme
In addition to the current and power accumulating after every sample, the shunt and bus voltage measurements
are also collected. Once all of the samples have been measured and the corresponding current and power
calculations have been made, the accumulated average for each of these parameters is then loaded to the
corresponding output registers, where they can then be read.
10
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
Averaging and Conversion Time Considerations
The INA226 has programmable conversion times for both the shunt voltage and bus voltage measurements. The
conversion times for these measurements can be selected from as fast as 140μs to as long as 8.244ms. The
conversion time settings, along with the programmable averaging mode, allow the INA226 to be configured to
optimize the available timing requirements in a given application. For example, if a system requires that data be
read every 5ms, the INA226 could be configured with the conversion times set to 588μs and the averaging mode
set to 4. This configuration results in the data updating approximately every 4.7ms. The INA226 could also be
configured with a different conversion time setting for the shunt and bus voltage measurements. This type of
approach is common in applications where the bus voltage tends to be relatively stable. This situation can allow
for the time focused on the bus voltage measurement to be reduced relative to the shunt voltage measurement.
The shunt voltage conversion time could be set to 4.156ms with the bus voltage conversion time set to 588μs,
with the averaging mode set to 1. This configuration also results in data updating approximately every 4.7ms.
There are trade-offs associated with the settings for conversion time and the averaging mode used. The
averaging feature can significantly improve the measurement accuracy by effectively filtering the signal. This
approach allows the INA226 to reduce any noise in the measurement that may be caused by noise coupling into
the signal. A greater number of averages enables the INA226 to be more effective in reducing the noise
component of the measurement.
The conversion times selected can also have an impact on the measurement accuracy. This effect can seen in
Figure 21. Multiple conversion times are shown here to illustrate the impact of noise on the measurement. In
order to achieve the highest accuracy measurement possible, a combination of the longest allowable conversion
times and highest number of averages should be used, based on the timing requirements of the system.
10mV/div
Conversion Time: 140ms
Conversion Time: 1.1ms
Conversion Time: 8.244ms
0
200
400
600
800
1000
Number of Conversions
Figure 21. Noise vs Conversion Time
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
11
INA226
SBOS547 – JUNE 2011
www.ti.com
Filtering and Input Considerations
Measuring current is often noisy, and such noise can be difficult to define. The INA226 offers several options for
filtering by allowing the conversion times and number of averages to be selected independently in the
Configuration Register. The conversion times can be set independently for the shunt voltage and bus voltage
measurements to allow added flexibility in configuring the monitoring of the power-supply bus.
The internal ADC is based on a delta-sigma (ΔΣ) front-end with a 500kHz (±30%) typical sampling rate. This
architecture has good inherent noise rejection; however, transients that occur at or very close to the sampling
rate harmonics can cause problems. Because these signals are at 1MHz and higher, they can be managed by
incorporating filtering at the input of the INA226. The high frequency enables the use of low-value series resistors
on the filter with negligible effects on measurement accuracy. In general, filtering the INA226 input is only
necessary if there are transients at exact harmonics of the 500kHz (±30%) sampling rate (greater than 1MHz).
Filter using the lowest possible series resistance (typically 10Ω or less) and a ceramic capacitor. Recommended
values for this capacitor are 0.1μF to 1.0μF. Figure 22 shows the INA226 with an additional filter added at the
input.
Overload conditions are another consideration for the INA226 inputs. The INA226 inputs are specified to tolerate
40V across the inputs. A large differential scenario might be a short to ground on the load side of the shunt. This
type of event can result in full power-supply voltage across the shunt (as long the power supply or energy
storage capacitors support it). Keep in mind that removing a short to ground can result in inductive kickbacks that
could exceed the 40V differential and common-mode rating of the INA226. Inductive kickback voltages are best
controlled by zener-type transient-absorbing devices (commonly called transzorbs) combined with sufficient
energy storage capacitance.
In applications that do not have large energy storage electrolytics on one or both sides of the shunt, an input
overstress condition may result from an excessive dV/dt of the voltage applied to the input. A hard physical short
is the most likely cause of this event, particularly in applications with no large electrolytics present. This problem
occurs because an excessive dV/dt can activate the ESD protection in the INA226 in systems where large
currents are available. Testing has demonstrated that the addition of 10Ω resistors in series with each input of
the INA226 sufficiently protect the inputs against this dV/dt failure up to the 40V rating of the INA226. Selecting
these resistors in the range noted has minimal effect on accuracy.
Power Supply
(0V to 36V)
CBYPASS
0.1mF
VS
(Supply Voltage)
VBUS
CFILTER
0.1mF to 1mF
Ceramic
Capacitor
SDA
SCL
´
RFILTER
£10W
VIN+
Power Register
V
2
Current Register
ADC
I
Load
RFILTER
£10W
Voltage Register
IC
Interface
Alert
A0
VINAlert Register
A1
GND
Figure 22. INA226 with Input Filtering
12
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
ALERT PIN
The INA226 has a single Alert Limit register, 07h, that allows the Alert pin to be programmed to respond to a
single user-defined event or to a conversion ready notification if desired. The Mask/Enable Register allows the
user to select from one of the five available functions to monitor and/or set the conversion ready bit to control the
response of the Alert pin. Based on the function being monitored, the user would then enter a value into the Alert
Limit Register to set the corresponding threshold value that asserts the Alert pin.
The Alert pin allows for one of several available alert functions to be monitored to determine if a user-defined
threshold has been exceeded. The five alert functions that can be monitored are:
•
•
•
•
•
Shunt Voltage Over Limit (SOL)
Shunt Voltage Under Limit (SUL)
Bus Voltage Over Limit (BOL)
Bus Voltage Under Limit (BUL)
Power Over Limit (POL)
The Alert pin is an open-drain output. This pin is asserted when the alert function selected in the Mask/Enable
register exceeds the value programmed into the Alert Limit register. Only one of these alert functions can be
enabled and monitored at a time. If multiple alert functions are enabled, the selected function in the highest
significant bit position takes priority and responds to the Alert Limit register value. For example, if the Shunt
Voltage Over Limit and the Shunt Voltage Under Limit are both selected, the Alert pin asserts when the Shunt
Voltage Over Limit Register exceeds the value in the Alert Limit register.
The Conversion Ready state of the device can also be monitored at the Alert pin to inform the user when the
device has completed the previous conversion and is ready to begin a new conversion. Conversion Ready can
be monitored at the Alert pin along with one of the alert functions. If an alert function and the Conversion Ready
are both enabled to be monitored at the Alert pin, after the Alert pin is asserted, the Mask/Enable register must
be read following the alert to determine the source of the alert. By reading the Conversion Ready Flag (CVRF),
bit D3, and the Alert Function Flag (AFF), bit D4 in the Mask/Enable register, the source of the alert can be
determined. If the conversion ready feature is not desired, and the CNVR bit is not set, the Alert pin only
responds to an exceeded alert limit based on the alert function enabled.
If the Alert function is not used, the Alert pin can be left floating without impacting the operation of the device.
Refer to Figure 20 to see the relative timing of when the value in the Alert Limit Register is compared to the
corresponding converted value. For example, if the alert function that is enabled is Shunt Voltage Over Limit
(SOL), following every shunt voltage conversion the value in the Alert Limit Register is compared to the
measured shunt voltage to determine if the measurements has exceeded the programmed limit. The AFF, bit 4 of
the Mask/Enable Register, asserts high any time the measured voltage exceeds the value programmed into the
Alert Limit Register. In addition to the AFF being asserted, the Alert pin is asserted based on the Alert Polarity Bit
(APOL, bit 1 of the Mask/Enable Register). If the Alert Latch is enabled, the AFF and Alert pin remain asserted
until either the Configuration Register is written to or the Mask/Enable Register is read.
The Bus Voltage alert functions compare the measured bus voltage to the Alert Limit Register following every
bus voltage conversion and assert the AFF bit and Alert pins if the limit threshold is exceeded.
The Power Over Limit alert function is also compared to the calculated power value following every bus voltage
measurement conversion and asserts the AFF bit and Alert pins if the limit threshold is exceeded.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
13
INA226
SBOS547 – JUNE 2011
www.ti.com
PROGRAMMING THE INA226
An important aspect of the INA226 is that it does not necessarily measure current or power. The INA226
measures both the differential voltage applied between the VIN+ and VIN- input pins and the voltage applied to
the VBUS pin. In order for the INA226 to report both current and power values, the user must program the
resolution of the Current Register and the value of the shunt resistor present in the application to develop the
differential voltage applied between the input pins. The Power Register is internally set to be 25 times the
programmed Current_LSB. Both the Current_LSB and shunt resistor value are used in the calculation of the
Calibration Register value the INA226 uses to calculate the corresponding current and power values based on
the measured shunt and bus voltages.
The Calibration Register is calculated based on Equation 1. This equation includes the term Current_LSB. This is
the programmed value for the LSB for the Current Register. This is the value the user will use to convert the
value in the Current Register to the actual current in amps. The highest resolution for the Current Register can
be obtained by using the smallest allowable Current_LSB based on the maximum expected current as shown in
Equation 2. While this value will yield the highest resolution, it is common to select a value for the Current_LSB
to the nearest round number above this value to simplify the conversion of the Current Register and Power
Register to amps and watts respectively. The RSHUNT term is the value of the external shunt used to develop
the differential voltage across the input pins. The 0.00512 value in Equation 1 is an internal fixed value used to
ensure scaling is maintained properly.
0.00512
CAL = Current_LSB · R
SHUNT
Current_LSB =
(1)
Maximum Expected Current
215
(2)
Once the Calibration Register has been programmed, the Current Register and Power Register will be updated
accordingly based on the corresponding shunt voltage and bus voltage measurements. Until the Calibration
Register is programmed, the Current and Power Registers remain at zero.
14
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
CONFIGURE/MEASURE/CALCULATE EXAMPLE
In this example, shown in Figure 23, a nominal 10A load creates a differential voltage of 20mV across a 2mΩ
shunt resistor. The bus voltage for the INA226 is measured at the external VBUS input pin, which in this example
is connected to the VIN– pin to measure the voltage level delivered to the load. For this example, the VBUS pin
measures less than 12V because the voltage at the VIN– pin is 11.98V as a result of the voltage drop across the
shunt resistor.
+12V Supply
CBYPASS
0.1mF
VS
(Supply Voltage)
VBUS
SDA
SCL
´
VIN+
Power Register
V
2
Current Register
ADC
RSHUNT
2mW
I
Voltage Register
IC
Interface
Alert
A0
VINAlert Register
10A
Load
A1
GND
Figure 23. Example Circuit Configuration
For this example, assuming a maximum expected current of 15A, the Current_LSB is calculated to be
457.7μA/bit using Equation 2. Using a value for the Current_LSB of 500μA/Bit or 1mA/Bit would significantly
simplifiy the conversion from the Current Register and Power Register to amps and watts. For this example, a
value of 1mA/bit was chosen for the current LSB. Using this value for the Current_LSB does trade a small
amount of resolution for having a simpler conversion process on the user side. Using Equation 1 in this example
with a current LSB of 1mA/bit and a shunt resistor of 2mΩ results in a Calibration Register value of 2560, or
A00h.
The Current Register (04h) is then calculated by multiplying the decimal value of the Shunt Voltage Register
contents by the decimal value of the Calibration Register and then dividing by 2048, as shown in Equation 3. For
this example, the Shunt Voltage Register contains a value of 8,000, which is multiplied by the Calibration
Register value of 2560 and then divided by 2048 to yield a decimal value for the Current Register of 10000, or
2710h. Multiplying this value by 1mA/bit results in the original 10A level stated in the example.
Current =
ShuntVoltage · CalibrationRegister
2048
(3)
The LSB for the Bus Voltage Register (02h) is a fixed 1.25mV/bit, which means that the 11.98V present at the
VBUS pin results in a register value of 2570h, or a decimal equivalent of 9584. Note that the MSB of the Bus
Voltage Register is always zero because the VBUS pin is only able to measure positive voltages.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
15
INA226
SBOS547 – JUNE 2011
www.ti.com
The Power Register (03h) is then be calculated by multiplying the decimal value of the Current Register, 10000,
by the decimal value of the Bus Voltage Register, 9584, and then dividing by 20,000, as defined in Equation 4.
For this example, the result for the Power Register is 12B8h, or a decimal equivalent of 4792. Multiplying this
result by the power LSB (25 times the [1 × 10–3 Current LSB]) results in a power calculation of (4792 ×
25mW/bit), or 119.82W. The power LSB has a fixed ratio to the current LSB of 25W/bit to 1A/bit. For this
example, a programmed 1mA/bit current LSB results in a power LSB of 25mW/bit. This ratio is internally
programmed to ensure that the scaling of the power calculation is within an acceptable range. A manual
calculation for the power being delivered to the load would use a bus voltage of 11.98V (12VCM – 20mV shunt
drop) multiplied by the load current of 10A to give a result of 119.8W.
Power =
Current · BusVoltage
20,000
(4)
Table 1 shows the steps for configuring, measuring, and calculating the values for current and power for this
device.
Table 1. Configure/Measure/Calculate Example (1)
(1)
STEP #
REGISTER NAME
ADDRESS
CONTENTS
DEC
LSB
Step 1
Configuration
00h
4127h
—
—
VALUE
—
Step 2
Shunt
01h
1F40h
8000
2.5µV
20mV
Step 3
Bus
02h
2570h
9584
1.25mV
11.98V
Step 4
Calibration
05h
A00h
2560
—
—
Step 5
Current
04h
2710
10000
1mA
10A
Step 6
Power
03h
12B8h
4792
25mW
119.82W
Conditions: Load = 10A, VCM = 12V, RSHUNT = 2mΩ, and VBUS = 12V.
PROGRAMMING THE INA226 POWER MEASUREMENT ENGINE
Calibration Register and Scaling
The Calibration Register makes it possible to set the scaling of the Current and Power Registers to whatever
values are most useful for a given application. One strategy may be to set the Calibration Register such that the
largest possible number is generated in the Current Register or Power Register at the expected full-scale point.
This approach would yield the highest resolution based using the previously calculated minimum current LSB in
the equation for the Calibration Register. The Calibration Register can also be selected to provide values in the
Current and Power Registers that either provide direct decimal equivalents of the values being measured, or
yield a round LSB value for each corresponding register. After these choices have been made, the Calibration
Register also offers possibilities for end user system-level calibration. By physically measuring the current with
an external ammeter, the exact current is known. The value of the Calibration Register can then be adjusted
based on the measured current result of the INA226 to cancel the total system error as shown in Equation 5.
Corrected_Full_Scale_Cal = trunc
Cal ´ MeasShuntCurrent
INA226_Current
(5)
16
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
Simple Current Shunt Monitor Usage
(No Programming Necessary)
The INA226 can be used without any programming if it is only necessary to read a shunt voltage drop and bus
voltage with the default power-on reset configuration and continuous conversion of shunt and bus voltage.
Without programming the INA226 Calibration Register, the device is unable to provide either a valid current or
power value, because these outputs are both derived using the values loaded into the Calibration Register.
Default INA226 Settings
The default power-up states of the registers are shown in the INA226 Register Descriptions section of this data
sheet. These registers are volatile, and if programmed to a value other than the default values shown in Table 2,
they must be re-programmed at every device power-up. Detailed information on programming the Calibration
Register specifically is given in the Configure/Measure/Calculate Example section and calculated based on
Equation 1.
REGISTER INFORMATION
The INA226 uses a bank of registers for holding configuration settings, measurement results, minimum/maximum
limits, and status information. Table 2 summarizes the INA226 registers; refer to Figure 1 for an illustration of the
registers.
Table 2. Summary of Register Set
POINTER
ADDRESS
(1)
(2)
POWER-ON RESET
HEX
REGISTER NAME
FUNCTION
BINARY
HEX
TYPE (1)
0
Configuration Register
All-register reset, shunt voltage and bus
voltage ADC conversion times and
averaging, operating mode.
01000001 00100111
4127
R/W
1
Shunt Voltage
Shunt voltage measurement data.
00000000 00000000
0000
R
2
Bus Voltage
Bus voltage measurement data.
00000000 00000000
0000
R
Contains the value of the calculated
power being delivered to the load.
00000000 00000000
0000
R
(2)
3
Power
4
Current (2)
Contains the value of the calculated
current flowing through the shunt
resistor.
00000000 00000000
0000
R
5
Calibration
Sets full-scale range and LSB of current
and power measurements. Overall
system calibration.
00000000 00000000
0000
R/W
6
Mask/Enable
Alert configuration and conversion ready
flag.
00000000 00000000
0000
R/W
7
Alert Limit
Contains the limit value to compare to
the selected Alert function.
00000000 00000000
0000
R/W
FF
Die ID
ASCII
ASCII
R
Contains unique die identification
number.
Type: R = Read-Only, R/W = Read/Write.
The Current Register defaults to '0' because the Calibration Register defaults to '0', yielding a zero current and power value until the
Calibration Register is programmed.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
17
INA226
SBOS547 – JUNE 2011
www.ti.com
REGISTER DETAILS
All 16-bit INA226 registers are two 8-bit bytes via the I2C interface.
Configuration Register 00h (Read/Write)
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
RST
—
—
—
AVG2
AVG1
AVG0
VBUSCT2
VBUSCT1
VBUSCT0
VSHCT2
VSHCT1
VSHCT0
MODE3
MODE2
MODE1
POR
VALUE
0
1
0
0
0
0
0
1
0
0
1
0
0
1
1
1
The Configuration Register settings control the operating modes for the INA226. This register controls the
conversion time settings for both the shunt and bus voltage measurements as well as the averaging mode used.
The operating mode that controls what signals are selected to be measured is also programmed in the
Configuration Register.
The Configuration Register can be read from at any time without impacting or affecting the device settings or a
conversion in progress. Writing to the Configuration Register will halt any conversion in progress until the write
sequence is completed resulting in a new conversion starting based on the new contents of the Configuration
Register. This prevents any uncertainty in the conditions used for the next completed conversion.
Bit Descriptions
RST:
Reset Bit
Bit 15
Setting this bit to '1' generates a system reset that is the same as power-on reset. Resets all registers to default
values; this bit self-clears.
AVG:
Averaging Mode
Bits 9–11
Sets the number of samples that will be collected and averaged together. Table 3 summarizes the AVG bit settings
and related number of averages for each bit.
Table 3. AVG Bit Settings[11:9] (1)
(1)
18
AVG2
D11
AVG1
D10
AVG0
D9
NUMBER OF
AVERAGES
0
0
0
1
0
0
1
4
0
1
0
16
0
1
1
64
1
0
0
128
1
0
1
256
1
1
0
512
1
1
1
1024
Shaded values are default.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
VBUS CT:
Bus Voltage Conversion Time
Bits 6–8
Sets the conversion time for the bus voltage measurement. Table 4 shows the VBUS CT bit options and related
conversion times for each bit.
Table 4. VBUS CT Bit Settings [8:6]
(1)
(1)
VBUS CT2
D8
VBUS CT1
D7
VBUS CT0
D6
CONVERSION TIME
0
0
0
140µs
0
0
1
204µs
0
1
0
332µs
0
1
1
588µs
1
0
0
1.1ms
1
0
1
2.116ms
1
1
0
4.156ms
1
1
1
8.244ms
Shaded values are default.
VSH CT:
Shunt Voltage Conversion Time
Bits 3–5
Sets the conversion time for the shunt voltage measurement. Table 5 shows the VSH CT bit options and related
conversion times for each bit.
Table 5. VSH CT Bit Settings [5:3] (1)
(1)
VSH CT2
D5
VSH CT1
D4
VSH CT0
D3
CONVERSION TIME
0
0
0
140µs
0
0
1
204µs
0
1
0
332µs
0
1
1
588µs
1
0
0
1.1ms
1
0
1
2.116ms
1
1
0
4.156ms
1
1
1
8.244ms
Shaded values are default.
MODE:
Operating Mode
Bits 0–2
Selects continuous, triggered, or power-down mode of operation. These bits default to continuous shunt and bus
measurement mode. The mode settings are shown in Table 6.
Table 6. Mode Settings [2:0] (1)
(1)
MODE3
D2
MODE2
D1
MODE1
D0
0
0
0
Power-Down
0
0
1
Shunt Voltage, Triggered
0
1
0
Bus Voltage, Triggered
0
1
1
Shunt and Bus, Triggered
1
0
0
Power-Down
1
0
1
Shunt Voltage, Continuous
1
1
0
Bus Voltage, Continuous
1
1
1
Shunt and Bus, Continuous
MODE
Shaded values are default.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
19
INA226
SBOS547 – JUNE 2011
www.ti.com
DATA OUTPUT REGISTERS
Shunt Voltage Register 01h (Read-Only)
The Shunt Voltage Register stores the current shunt voltage reading, VSHUNT. Negative numbers are represented
in twos complement format. Generate the twos complement of a negative number by complementing the
absolute value binary number and adding 1. Extend the sign, denoting a negative number by setting the MSB =
'1'.
Example: For a value of VSHUNT = –80mV:
1. Take the absolute value: 80mV
2. Translate this number to a whole decimal number (80mV ÷ 2.5µV) = 32000
3. Convert this number to binary = 111 1101 0000 0000
4. Complement the binary result = 000 0010 1111 1111
5. Add '1' to the complement to create the twos complement result = 000 0011 0000 0000
6. Extend the sign and create the 16-bit word: 1000 0011 0000 0000 = 8300h
If averaging is enabled, this register displays the averaged value. Full-scale range = 81.92mV (decimal = 7FFF);
LSB: 2.5μV.
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
SIGN
SD14
SD13
SD12
SD11
SD10
SD9
SD8
SD7
SD6
SD5
SD4
SD3
SD2
SD1
SD0
POR
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bus Voltage Register 02h (Read-Only) (1)
The Bus Voltage Register stores the most recent bus voltage reading, VBUS.
If averaging is enabled, this register displays the averaged value. Full-scale range = 40.96V (decimal = 7FFF);
LSB = 1.25mV.
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
—
BD14
BD13
BD12
BD11
BD10
BD9
BD8
BD7
BD6
BD5
BD4
BD3
BD2
BD1
BD0
POR
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
(1)
D15 is always zero because bus voltage can only be positive.
Power Register 03h (Read-Only)
If averaging is enabled, this register displays the averaged value.
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
PD15
PD14
PD13
PD12
PD11
PD10
PD9
PD8
PD7
PD6
PD5
PD4
PD3
PD2
PD1
PD0
POR
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
The Power Register LSB is internally programmed to equal 25 times the programmed value of the Current_LSB.
The Power Register records power in watts by multiplying the decimal values of the current register with the
decimal value of the bus voltage register according to Equation 4.
20
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
Current Register 04h (Read-Only)
If averaging is enabled, this register displays the averaged value.
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
CSIGN
CD14
CD13
CD12
CD11
CD10
CD9
CD8
CD7
CD6
CD5
CD4
CD3
CD2
CD1
CD0
POR
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
The value of the Current Register is calculated by multiplying the decimal value in the Shunt Voltage Register
with the decimal value of the Calibration Register, according to Equation 3.
Calibration Register 05h (Read/Write)
This register provides the INA226 with the value of the shunt resistor that was present to create the measured
differential voltage. It also sets the resolution of the Current Register. The current LSB and power LSB are set
through the programming of this register. This register is also suitable for use in overall system calibration. See
the Configure/Measure/Calculate Example for additional information on programming the Calibration Register.
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
—
FS14
FS13
FS12
FS11
FS10
FS9
FS8
FS7
FS6
FS5
FS4
FS3
FS2
FS1
FS0
POR
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Mask/Enable 06h (Read/Write)
The Mask/Enable Register selects the function that is enabled to control the Alert pin, as well as how that pin
functions. If multiple functions are enabled, the highest significant bit position Alert Function (D11-D15) takes
priority and responds to the Alert Limit register.
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
SOL
SUL
BOL
BUL
POL
CNVR
—
—
—
—
—
AFF
CVRF
OVF
APOL
LEN
POR
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
SOL:
Shunt Voltage Over-Voltage
Bit 15
Setting this bit high configures the Alert pin to be asserted when the Shunt Voltage Register exceeds the value in
the Alert Limit Register.
SUL:
Shunt Voltage Under-Voltage
Bit 14
Setting this bit high configures the Alert pin to be asserted when the Shunt Voltage Register drops below the value
in the Alert Limit Register.
BOL:
Bus Voltage Over-Voltage
Bit 13
Setting this bit high configures the Alert pin to be asserted when the Bus Voltage Register exceeds the value in the
Alert Limit Register.
BUL:
Bus Voltage Under-Voltage
Bit 12
Setting this bit high configures the Alert pin to be asserted when the Bus Voltage Register drops below the value in
the Alert Limit Register.
POL:
Over-Limit Power
Bit 11
Setting this bit high configures the Alert pin to be asserted when the Power Register exceeds the value in the Alert
Limit Register.
CNVR:
Conversion Ready
Bit 10
Setting this bit high configures the Alert pin to be asserted when the Conversion Ready Flag, Bit 3, is asserted
indicating that the device is ready for the next conversion.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
21
INA226
SBOS547 – JUNE 2011
www.ti.com
AFF:
Alert Function Flag
Bit 4
While only one Alert Function can be monitored at the Alert pin at a time, the Conversion Ready can also be
enabled to assert the Alert pin. Reading the Alert Function Flag following an alert allows the user to determine if the
Alert Function was the source of the Alert.
When the Alert Latch Enable bit is set to Latch mode, the Alert Function Flag clears only when the Mask/Enable
Register is read. When the Alert Latch Enable bit is set to Transparent mode, the Alert Function Flag is cleared
following the next conversion that does not result in an Alert condition.
CVRF:
Conversion Ready Flag
Bit 3
Although the INA226 can be read at any time, and the data from the last conversion is available, the Conversion
Ready bit is provided to help coordinate one-shot or triggered conversions. The Conversion bit is set after all
conversions, averaging, and multiplications are complete. Conversion Ready clears under the following conditions:
1.) Writing to the Configuration Register (except for Power-Down or Disable selections)
2.) Reading the Mask/Enable Register
OVF:
Math Overflow Flag
Bit 2
This bit is set to '1' if an arithmetic operation resulted in an overflow error. It indicates that current and power data
may be invalid.
APOL:
Alert Polarity bit; sets the Alert pin polarity.
Bit 1
1 = Inverted (active-high open collector)
0 = Normal (active-low open collector) (default)
LEN:
Alert Latch Enable; configures the latching feature of the Alert pin and Flag bits.
Bit 0
1 = Latch enabled
0 = Transparent (default)
When the Alert Latch Enable bit is set to Transparent mode, the Alert pin and Flag bits will reset to their idle states
when the fault has been cleared. When the Alert Latch Enable bit is set to Latch mode, the Alert pin and Flag bits
will remain active following a fault until the Mask/Enable Register has been read.
Alert Limit 07h (Read/Write)
The Alert Limit Register contains the value used to compare to the register selected in the Mask/Enable Register
to determine if a limit has been exceeded.
BIT #
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
BIT
NAME
AUL15
AUL14
AUL13
AUL12
AUL11
AUL10
AUL9
AUL8
AUL7
AUL6
AUL5
AUL4
AUL3
AUL2
AUL1
AUL0
POR
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
BUS OVERVIEW
The INA226 offers compatibility with both I2C and SMBus interfaces. The I2C and SMBus protocols are
essentially compatible with one another.
The I2C interface is used throughout this data sheet as the primary example, with SMBus protocol specified only
when a difference between the two systems is discussed. Two bidirectional lines, SCL and SDA, connect the
INA226 to the bus. Both SCL and SDA are open-drain connections.
The device that initiates a data transfer is called a master, and the devices controlled by the master are slaves.
The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access,
and generates START and STOP conditions.
To address a specific device, the master initiates a start condition by pulling the data signal line (SDA) from a
high to a low logic level while SCL is high. All slaves on the bus shift in the slave address byte on the rising edge
of SCL, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the
slave being addressed responds to the master by generating an Acknowledge and pulling SDA low.
22
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
Data transfer is then initiated and eight bits of data are sent, followed by an Acknowledge bit. During data
transfer, SDA must remain stable while SCL is high. Any change in SDA while SCL is high is interpreted as a
start or stop condition.
Once all data have been transferred, the master generates a stop condition, indicated by pulling SDA from low to
high while SCL is high. The INA226 includes a 28ms timeout on its interface to prevent locking up the bus.
Serial Bus Address
To communicate with the INA226, the master must first address slave devices via a slave address byte. The
slave address byte consists of seven address bits and a direction bit that indicates whether the action is to be a
read or write operation.
The INA226 has two address pins, A0 and A1. Table 7 describes the pin logic levels for each of the 16 possible
addresses. The state of pins A0 and A1 is sampled on every bus communication and should be set before any
activity on the interface occurs.
Table 7. INA226 Address Pins and
Slave Addresses
A1
A0
SLAVE ADDRESS
GND
GND
1000000
GND
VS+
1000001
GND
SDA
1000010
GND
SCL
1000011
VS+
GND
1000100
VS+
VS+
1000101
VS+
SDA
1000110
VS+
SCL
1000111
SDA
GND
1001000
SDA
VS+
1001001
SDA
SDA
1001010
SDA
SCL
1001011
SCL
GND
1001100
SCL
VS+
1001101
SCL
SDA
1001110
SCL
SCL
1001111
Serial Interface
The INA226 operates only as a slave device on both the I2C bus and the SMBus. Connections to the bus are
made via the open-drain I/O lines SDA and SCL. The SDA and SCL pins feature integrated spike suppression
filters and Schmitt triggers to minimize the effects of input spikes and bus noise. While there is spike suppression
integrated into the digital I/O lines, proper layout should be used to minimize the amount of coupling into the
communication lines. This noise introduction could occur from capacitively coupling signal edges between the
two communication lines themselves or from other switching noise sources present in the system. Routing traces
in parallel with ground in between layers on a printed circuit board (PCB) typically reduces the effects of coupling
between the communication lines. Shielding communication lines in general is recommended to reduce to
possibility of unintended noise coupling into the digital I/O lines that could be incorrectly interpreted as start or
stop commands.
The INA226 supports the transmission protocol for Fast (1kHz to 400kHz) and High-speed (1kHz to 3.4MHz)
modes. All data bytes are transmitted most significant byte first.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
23
INA226
SBOS547 – JUNE 2011
www.ti.com
WRITING TO/READING FROM THE INA226
Accessing a specific register on the INA226 is accomplished by writing the appropriate value to the register
pointer. Refer to Table 2 for a complete list of registers and corresponding addresses. The value for the register
pointer (as shown in Figure 27) is the first byte transferred after the slave address byte with the R/W bit low.
Every write operation to the INA226 requires a value for the register pointer.
Writing to a register begins with the first byte transmitted by the master. This byte is the slave address, with the
R/W bit low. The INA226 then acknowledges receipt of a valid address. The next byte transmitted by the master
is the address of the register which data will be written to. This register address value updates the register
pointer to the desired register. The next two bytes are written to the register addressed by the register pointer.
The INA226 acknowledges receipt of each data byte. The master may terminate data transfer by generating a
start or stop condition.
When reading from the INA226, the last value stored in the register pointer by a write operation determines
which register is read during a read operation. To change the register pointer for a read operation, a new value
must be written to the register pointer. This write is accomplished by issuing a slave address byte with the R/W
bit low, followed by the register pointer byte. No additional data are required. The master then generates a start
condition and sends the slave address byte with the R/W bit high to initiate the read command. The next byte is
transmitted by the slave and is the most significant byte of the register indicated by the register pointer. This byte
is followed by an Acknowledge from the master; then the slave transmits the least significant byte. The master
acknowledges receipt of the data byte. The master may terminate data transfer by generating a
Not-Acknowledge after receiving any data byte, or generating a start or stop condition. If repeated reads from the
same register are desired, it is not necessary to continually send the register pointer bytes; the INA226 retains
the register pointer value until it is changed by the next write operation.
Figure 24 and Figure 25 show the write and read operation timing diagrams, respectively. Note that register
bytes are sent most-significant byte first, followed by the least significant byte.
1
9
9
1
9
1
9
1
SCL
SDA
1
0
0
A3
A2
A1
A0
R/W
Start By
Master
P7
P6
P5
P4
P3
P2
P1
ACK By
INA226
Frame 1 Two-Wire Slave Address Byte
(1)
P0
D15 D14
D13
D12 D11 D10
D9
D8
(1)
D7
D6
D5
D4
D3
D2
D1
D0
ACK By
INA226
ACK By
INA226
Frame 2 Register Pointer Byte
ACK By
INA226
Frame 3 Data MSByte
Stop By
Master
Frame 4 Data LSByte
The value of the Slave Address byte is determined by the settings of the A0 and A1 pins. Refer to Table 7.
Figure 24. Timing Diagram for Write Word Format
1
9
1
9
1
9
SCL
SDA
1
0
0
A3
A2
A1
A0
R/W
Start By
Master
D15 D14
ACK By
INA226
Frame 1 Two-Wire Slave Address Byte
(1)
D13
D12
D11 D10
D9
D8
From
INA226
Frame 2 Data MSByte
D7
D6
D5
D4
D3
D2
D1
From
INA226
ACK By
Master
(2)
Frame 3 Data LSByte
D0
No ACK By
Master
(3)
Stop
(2)
(1)
The value of the Slave Address byte is determined by the settings of the A0 and A1 pins. Refer to Table 7.
(2)
Read data is from the last register pointer location. If a new register is desired, the register pointer must be updated.
See Figure 23.
(3)
ACK by Master can also be sent.
Figure 25. Timing Diagram for Read Word Format
24
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
Figure 26 shows the timing diagram for the SMBus Alert response operation. Figure 27 illustrates a typical
register pointer configuration.
ALERT
1
9
1
9
SCL
SDA
0
0
0
1
1
0
0
R/W
Start By
Master
1
0
0
A2
ACK By
INA226
A1
A0
0
From
INA226
Frame 1 SMBus ALERT Response Address Byte
(1)
A3
Frame 2 Slave Address Byte
NACK By
Master
Stop By
Master
(1)
The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 7.
Figure 26. Timing Diagram for SMBus ALERT
1
9
1
9
SCL
¼
SDA
1
0
0
A3
A2
A1
A0
R/W
Start By
Master
Frame 1 Two-Wire Slave Address Byte
(1)
P7
P6
P5
P4
P3
P2
P1
ACK By
INA226
(1)
P0
Stop
ACK By
INA226
Frame 2 Register Pointer Byte
The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 7.
Figure 27. Typical Register Pointer Set
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
25
INA226
SBOS547 – JUNE 2011
www.ti.com
High-Speed I2C Mode
When the bus is idle, both the SDA and SCL lines are pulled high by the pull-up devices. The master generates
a start condition followed by a valid serial byte containing High-Speed (HS) master code 00001XXX. This
transmission is made in fast (400kHz) or standard (100kHz) (F/S) mode at no more than 400kHz. The INA226
does not acknowledge the HS master code, but does recognize it and switches its internal filters to support
3.4MHz operation.
The master then generates a repeated start condition (a repeated start condition has the same timing as the start
condition). After this repeated start condition, the protocol is the same as F/S mode, except that transmission
speeds up to 3.4MHz are allowed. Instead of using a stop condition, repeated start conditions should be used to
secure the bus in HS-mode. A stop condition ends the HS-mode and switches all the internal filters of the
INA226 to support the F/S mode.
t(LOW)
tF
tR
t(HDSTA)
SCL
t(HDSTA)
t(HIGH)
t(SUSTO)
t(SUSTA)
t(HDDAT)
t(SUDAT)
SDA
t(BUF)
P
S
S
P
Figure 28. Bus Timing Diagram
Bus Timing Diagram Definitions
FAST MODE
PARAMETER
HIGH-SPEED MODE
MIN
MAX
MIN
MAX
UNITS
SCL operating frequency
f(SCL)
0.001
0.4
0.001
3.4
MHz
Bus free time between stop and start
conditions
t(BUF)
600
160
ns
Hold time after repeated START condition.
After this period, the first clock is generated.
t(HDSTA)
100
100
ns
Repeated start condition setup time
t(SUSTA)
100
100
ns
STOP condition setup time
t(SUSTO)
100
100
ns
Data hold time
t(HDDAT)
0
0
ns
Data setup time
t(SUDAT)
100
10
ns
SCL clock low period
t(LOW)
1300
160
ns
SCL clock high period
t(HIGH)
600
60
Clock/data fall time
tF
Clock/data rise time
Clock/data rise time for SCLK ≤ 100kHz
26
ns
300
160
ns
tR
300
160
ns
tR
1000
Submit Documentation Feedback
ns
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
INA226
SBOS547 – JUNE 2011
www.ti.com
SMBus Alert Response
The INA226 is designed to respond to the SMBus Alert Response address. The SMBus Alert Response provides
a quick fault identification for simple slave devices. When an Alert occurs, the master can broadcast the Alert
Response slave address (0001 100) with the Read/Write bit set high. Following this Alert Response, any slave
devices that generated an alert will identify themselves by acknowledging the Alert Response and sending their
respective address on the bus.
The Alert Response can activate several different slave devices simultaneously, similar to the I2C General Call. If
more than one slave attempts to respond, bus arbitration rules apply. The losing device does not generate an
Acknowledge and continues to hold the Alert line low until the interrupt is cleared.
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): INA226
27
PACKAGE OPTION ADDENDUM
www.ti.com
11-Apr-2013
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
(2)
MSL Peak Temp
Op Temp (°C)
Top-Side Markings
(3)
(4)
INA226AIDGSR
ACTIVE
VSSOP
DGS
10
2500
Green (RoHS CU NIPDAUAG Level-2-260C-1 YEAR
& no Sb/Br)
-40 to 125
226
INA226AIDGST
ACTIVE
VSSOP
DGS
10
250
Green (RoHS CU NIPDAUAG Level-2-260C-1 YEAR
& no Sb/Br)
-40 to 125
226
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
Multiple Top-Side Markings will be inside parentheses. Only one Top-Side Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a
continuation of the previous line and the two combined represent the entire Top-Side Marking for that device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
Samples
PACKAGE MATERIALS INFORMATION
www.ti.com
19-Nov-2012
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
Package Package Pins
Type Drawing
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
INA226AIDGSR
VSSOP
DGS
10
2500
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
INA226AIDGST
VSSOP
DGS
10
250
330.0
12.4
5.3
3.4
1.4
8.0
12.0
Q1
Pack Materials-Page 1
PACKAGE MATERIALS INFORMATION
www.ti.com
19-Nov-2012
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
INA226AIDGSR
VSSOP
DGS
10
2500
366.0
364.0
50.0
INA226AIDGST
VSSOP
DGS
10
250
366.0
364.0
50.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated
Similar pages