Click on Series name for product info on aimtec.com Series AM3TI-RZ 3 Watt | DC-DC Converter FEATURES: No Minimum Load 24 Pin DIP Package Wide 2:1 Input Range High Efficiency up to 81% Over Load Protection Operating Temperature -40 to +85°C Input / Output Isolation 1500 or 3000 VDC Internal EMC Filter Meets EN55022 Class A Continuous Short Circuit Protection Input Under Voltage Lockout Models Single output Input Voltage (V) Output Voltage (V) Output Current Max (mA) Isolation (VDC) Max Capacitive Load (uF) AM3TI-1203S-RZ AM3TI-1205S-RZ AM3TI-1212S-RZ AM3TI-1215S-RZ AM3TI-1224S-RZ AM3TI-2403S-RZ AM3TI-2405S-RZ AM3TI-2412S-RZ AM3TI-2415S-RZ AM3TI-2424S-RZ AM3TI-4803S-RZ AM3TI-4805S-RZ AM3TI-4812S-RZ AM3TI-4815S-RZ AM3TI-4824S-RZ 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 3.3 5 12 15 24 3.3 5 12 15 24 3.3 5 12 15 24 900 600 250 200 125 900 600 250 200 125 900 600 250 200 125 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 470 470 100 100 47 470 470 100 100 47 470 470 100 100 47 339 325 313 313 316 172 164 156 156 156 84 80 78 78 78 7 7 10 10 20 7 7 7 7 10 7 7 7 7 7 74 78 81 81 80 73 77 81 81 81 75 79 81 81 81 AM3TI-1203SH30-RZ AM3TI-1205SH30-RZ AM3TI-1212SH30-RZ AM3TI-1215SH30-RZ AM3TI-1224SH30-RZ AM3TI-2403SH30-RZ AM3TI-2405SH30-RZ AM3TI-2412SH30-RZ AM3TI-2415SH30-RZ AM3TI-2424SH30-RZ AM3TI-4803SH30-RZ AM3TI-4805SH30-RZ AM3TI-4812SH30-RZ AM3TI-4815SH30-RZ AM3TI-4824SH30-RZ 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 3.3 5 12 15 24 3.3 5 12 15 24 3.3 5 12 15 24 900 600 250 200 125 900 600 250 200 125 900 600 250 200 125 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 470 470 100 100 47 470 470 100 100 47 470 470 100 100 47 339 325 313 313 316 172 164 156 156 156 84 80 78 78 78 7 7 10 10 20 7 7 7 7 10 7 7 7 7 7 74 78 81 81 80 73 77 81 81 81 75 79 81 81 81 Input Voltage (V) Output Voltage (V) Output Current Max (mA) Isolation (VDC) Max Capacitive Load (uF) 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 ±3.3 ±5 ±12 ±15 ±24 ±3.3 ±5 ±12 ±15 ±24 ±450 ±300 ±125 ±100 ±63 ±450 ±300 ±125 ±100 ±63 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 ±220 ±220 ±100 ±100 ±47 ±220 ±220 ±100 ±100 ±47 Model Input Current Full Load | No Load (mA) Efficiency (%) Models Dual output Model AM3TI-1203D-RZ AM3TI-1205D-RZ AM3TI-1212D-RZ AM3TI-1215D-RZ AM3TI-1224D-RZ AM3TI-2403D-RZ AM3TI-2405D-RZ AM3TI-2412D-RZ AM3TI-2415D-RZ AM3TI-2424D-RZ www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 1 of 6 Input Current Full Load | No Load (mA) 339 325 313 313 319 167 160 156 156 158 10 10 15 20 35 7 7 10 15 20 Efficiency (%) 74 78 81 81 80 75 79 81 81 81 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3TI-RZ 3 Watt | DC-DC Converter Models Dual output (continued) Input Voltage (V) Output Voltage (V) Output Current Max (mA) Isolation (VDC) Max Capacitive Load (uF) AM3TI-4803D-RZ AM3TI-4805D-RZ AM3TI-4812D-RZ AM3TI-4815D-RZ AM3TI-4824D-RZ 36-75 36-75 36-75 36-75 36-75 ±3.3 ±5 ±12 ±15 ±24 ±450 ±300 ±125 ±100 ±63 1500 1500 1500 1500 1500 ±220 ±220 ±100 ±100 ±47 81 78 78 78 81 7 7 7 7 15 77 81 81 81 79 AM3TI-1203DH30-RZ AM3TI-1205DH30-RZ AM3TI-1212DH30-RZ AM3TI-1215DH30-RZ AM3TI-1224DH30-RZ AM3TI-2403DH30-RZ AM3TI-2405DH30-RZ AM3TI-2412DH30-RZ AM3TI-2415DH30-RZ AM3TI-2424DH30-RZ AM3TI-4803DH30-RZ AM3TI-4805DH30-RZ AM3TI-4812DH30-RZ AM3TI-4815DH30-RZ AM3TI-4824DH30-RZ 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 ±3.3 ±5 ±12 ±15 ±24 ±3.3 ±5 ±12 ±15 ±24 ±3.3 ±5 ±12 ±15 ±24 ±450 ±300 ±125 ±100 ±63 ±450 ±300 ±125 ±100 ±63 ±450 ±300 ±125 ±100 ±63 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 ±220 ±220 ±100 ±100 ±47 ±220 ±220 ±100 ±100 ±47 ±220 ±220 ±100 ±100 ±47 339 325 313 313 319 167 160 156 156 158 81 78 78 78 81 10 10 15 20 35 7 7 10 15 20 7 7 7 7 15 75 79 81 81 81 75 79 81 81 81 77 81 81 81 79 Model Input Current Full Load | No Load (mA) Efficiency (%) Input Specifications Parameters Voltage range Nominal Typical 12 24 48 9-18 18-36 36-75 Input Reflected Ripple Current Under Voltage Lockout Units VDC (Pi) Network Filter Startup time Absolute Maximum Rating Maximum 20 12 Vin 24 Vin 48 Vin Refer to application test circuit 12 Vin 24 Vin 48 Vin ms 25 50 100 VDC 20 mA p-p (Model On / Off) 8.5 / 7.0 (Model On / Off) 16.5 / 14.5 (Model On / Off) 34.5 / 30.0 VDC Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 60 sec Rated Units 1500 or 3000 VDC MOhm pF Maximum Units > 1000 1000 Output Specifications Parameters Voltage Accuracy Voltage Balance Short Circuit Protection Short Circuit Restart Over Load Protection Line Voltage Regulation Load Voltage Regulation www.aimtec.com F 051e R12.B Conditions Typical ±2 ±2 % % Continuous Auto Recovery 160% Iout ±0.5 ±1.2 0 – 100% load Tel: +1 514 620 2722 2 of 6 % % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3TI-RZ 3 Watt | DC-DC Converter Output Specifications (continued) Parameters Conditions Typical Transient Recovery Time Transient Deviation Cross Regulation (Dual) (other models) (Single output 3.3V) 25% min load one output & 100% load on other Temperature Coefficient Ripple & Noise * (other models) (24V dual Models) Maximum Units 300 ±3 ±5 µsec ±5 % ±0.02 80 100 %/oC % mV p-p *- 20MHz Bandwidth measured with 1µf capacitor General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load Derating above 70 330 Maximum Units 100 KHz oC oC oC -40 to +85 -55 to +125 Free air convection 95 % Plastic (UL94V-0 rated) 13 g Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm >800 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency Approval Standards CE, UL IEC/EN 60950-1 EN 55022 Class A EN 55024 Class A IEC61000-4-2, Perf. Criteria A IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria A IEC61000-4-5, Perf. Criteria A IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Pin Out Specifications Pin Single Dual 2 3 9 11 14 16 22 23 -V Input -V Input Omitted N.C. +V Output -V Output +V Input +V Input -V Input -V Input Common -V Output +V Output Common +V Input +V Input www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 3 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3TI-RZ 3 Watt | DC-DC Converter Dimensions Derating Free Air Convection 70 ºC Output Power % 100 80 60 Safe Operating Area 40 20 0 85 -40 -20 0 20 40 60 80 100 Ambient Temperature º C www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 4 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3TI-RZ 3 Watt | DC-DC Converter Input Reflected Ripple Current Test Circuit Typical Efficiency Example Charts Eff % AM3TI‐1215S‐RZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 10% 20% 40% 60% 80% 100% Loading % www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 5 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3TI-RZ 3 Watt | DC-DC Converter Eff % AM3TI‐2405S‐RZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 10% 20% 40% 60% 80% 100% Loading % Eff % AM3TI‐4812S‐RZ Efficiency vs. Loading 100 90 80 70 60 50 40 30 20 10 0 10% 20% 40% 60% 80% 100% Loading % NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 6 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only