Series AM2Q-Z 2 Watt | DC-DC Converter FEATURES: RoHS Compliant Wide 2:1 input range High Efficiency up to 83% Continuous short circuit Operating Temperature -40ºC to 85ºC Input / Output Isolation of 500VAC No Tantalum capacitors used inside Over voltage protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) 4.5-9 4.5-9 4.5-9 9-18 9-18 9-18 18-36 18-36 18-36 36-75 36-75 36-75 5 12 15 5 12 15 5 12 15 5 12 15 300 130 100 300 130 100 300 130 100 300 130 100 500 500 500 500 500 500 500 500 500 500 500 500 100 100 100 100 100 100 100 100 100 100 100 100 73 78 78 75 80 81 74 78 79 73 78 78 Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) 4.5-9 4.5-9 9-18 9-18 18-36 18-36 36-75 36-75 ±12 ±15 ±12 ±15 ±12 ±15 ±12 ±15 ±65 ±50 ±65 ±50 ±65 ±50 ±65 ±50 500 500 500 500 500 500 500 500 ±100 ±100 ±100 ±100 ±100 ±100 ±100 ±100 82 81 83 83 81 82 80 79 AM2Q-0505SZ AM2Q-0512SZ AM2Q-0515SZ AM2Q-1205SZ AM2Q-1212SZ AM2Q-1215SZ AM2Q-2405SZ AM2Q-2412SZ AM2Q-2415SZ AM2Q-4805SZ AM2Q-4812SZ AM2Q-4815SZ Models Dual output Model AM2Q-0512DZ AM2Q-0515DZ AM2Q-1212DZ AM2Q-1215DZ AM2Q-2412DZ AM2Q-2415DZ AM2Q-4812DZ AM2Q-4815DZ NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 5 12 24 48 4.5-9 9-18 18-36 36-75 LC Type 20 30 20 Filter Start up time No Load Input Current Input reflected current www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 1 of 3 Maximum Units VDC ms mA mA Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2Q-Z 2 Watt | DC-DC Converter Isolation Specifications Parameters Conditions Typical 3sec 500 50 500 Tested I/O voltage Resistance Capacitance Maximum Units VAC MOhm pF Output Specifications Parameters Conditions Typical Voltage accuracy Cross Regulation (Dual Output Models) Over voltage protection 25% load on one output / 100% load on the other output LL-HL Load:0-100% unbalanced 20MHz Bandwidth Units % ±5 % 5 12 15 ±12 ±15 Continuous Auto Recovery ±0.5 ±1 ±0.02 50 0 Zener Diode Clamp Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Minimum Load Current Maximum ±1 6.2 15 18 ±15 ±18 V % of Vin % %/oC mV p-p % of Max General Specifications Parameters Switching frequency Operating temperature (Dual) Operating temperature (Single) Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Transient recovery deviation Conditions Typical 100% load Derating above 60ºC No Derating 100 Maximum Units 100 KHz o C o C o C o C -40 to +85 -40 to +85 -40 to +125 Free Air Convection 95 Nickel Coated Copper 10 1.08 x 0.70x 0.28 inches 27.50 x 18.00 x 7.00 mm >1.6Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C ) ±3 % RH g % Safety Specifications Parameters Standards Designed to meet IEC/EN 60950-1 Pin Out Specifications Pin Single Dual 1 2 3 4 5 -V Input +V Input +V Output NP -V Output -V Input +V Input +V Output Common -V Output NP: Not Populated www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2Q-Z 2 Watt | DC-DC Converter 6.35 (0.25) 6.35 (0.25) 6.35 (0.25) 7.00 (0.28) 2.70 (0.11) 4.40 (0.17) 6.60 (0.26) 18.00 (0.70) 2.65 (0.10) Dimensions Derating (Dual outputs) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only