Power-One MPU150-3300 Power factor correction (pfc) with a low-profile package Datasheet

MPU150/MDU150 Series Data Sheet
Features
•
•
•
•
•
•
•
•
•
•
RoHS lead free solder and lead solder exempted products
are available
Power Factor Correction (PFC) meets EN61000-3-2
Low-profile height fits 1U constraints
Dual main outputs provide 3.3V and 5V for mixed mode
applications
Single wire current sense on outputs V1 and V2
Remote sense on outputs V1 and V2
Overtemperature, overload, and overvoltage protection
Available with metric or SAE mountings
Greater than 340,000 Hours MTBF
MDU150 models have 48VDC input
Description
The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet
1U height constraints. The MPU150-4530 and MPU150-4350 provide high current +3.3V and +5V on a single platform
to support mixed-mode, high-speed digital circuitry. Power-One’s unique dual converter architecture combines high
reliability with exceptional regulation.
All multiple output models feature remote sense on outputs V1 and V2 to provide independent compensation of output
cable losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and
remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per
cubic inch.
The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.
AC Input, Single Output Model Selection MODEL
MPU150-S259
MPU150-S262
MPU150-S261
180W WITH 300 LFM FORCED-AIR COOLING
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
15A (Note 3)
7.5A (Note 3)
3.75A (Note 3)
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
Model numbers highlighted in yellow or shaded are not recommended for new designs. See MPU200 for new designs.
AC Input, Multiple Output Model Selection -
150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
MPU150-3300
MPU150-3524
MPU150-4000
MPU150-4230
MPU150-4350
MPU150-4530
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
INITIAL SETTING
ACCURACY
+3.3V
+5V
+12V
+5V
+12V
+24V
+5V
+12V
12V
5V
+2.5V
+3.3V
12V
5V
+3.3V
+5V
12V
12V
+5V
+3.3V
12V
12V
3.15V to 3.80V
5.0V to 5.5V
Fixed
5.0V to 5.5V
10.8V to 13.2V
Fixed
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
2.25V to 3.0V
3.15V to 3.8V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.80V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
35A
20A
2A
17.5A
4A
2A
30A (Note 4)
8A
3A
2A
30A (Note 4)
15A (Note 4)
4A (Note 5)
2A (Note 5)
30A (Note 4)
15A (Note 4)
3A (Note 5)
3A (Note 5)
30A (Note 4)
15A (Note 4)
3A (Note 5)
3A (Note 5)
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.8%
0.6%
0.4%
0.4%
0.6%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
1.5%
3%
3%
1%
3%
3%
1%
1%
1%
1%
2%
1.5%
1%
1%
1.5%
1%
7%
7%
1%
1.5%
7%
7%
1.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
2%
1.5%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
3.28V to 3.32V
4.98V to 5.02V
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
23.52V to 24.48V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
11.94V to 12.06V
4.98V to 5.0V
3.28V to 3.32V
5.00V to 5.04V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Total power of 180 Watts.
JUN 08, 2006 revised to JUL 14, 2006
Page 1 of 6
4) Total current between V1 and V2 is 30A, maximum rating.
5) Total current between V3 and V4 is 5A, maximum rating.
www.power-one.com
MPU150/MDU150 Series Data Sheet
DC Input Model Selection -
150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
MDU150-3300
MDU150-4000
MDU150-4230
MDU150-4350
MDU150-4530
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
INITIAL SETTING
ACCURACY
+3.3V
+5V
+12V
+5V
+12V
12V
5V
+2.5V
+3.3V
12V
5V
+3.3V
+5V
12V
12V
+5V
+3.3V
12V
12V
3.15V to 3.80V
5.0V to 5.5V
N/A
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
2.25V to 3.0V
3.15V to 3.8V
10.8V to 13.2V
5.0V to 5.5 V
3.15V to 3.8V
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
35A
20A
2A
30A (Note 3)
8A
3A
2A
30A (Note 3)
15A (Note 3)
3A
2A
30A (Note 5)
15A (Note 5)
3A (Note 4)
3A (Note 4)
30A (Note 3)
15A (Note 3)
3A (Note 4)
3A (Note 4)
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
2%
1.5%
1%
1%
1.5%
1%
7%
7%
0.4%
0.6%
0.4%
0.4%
1.5%
3%
3%
1%
1%
1%
1%
2%
1.5%
1%
1%
1.5%
1%
7%
7%
1%
1.5%
7%
7%
1.5%
1%
1%
1%
1%
1%
1%
2%
1.5%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
3.28V to 3.32V
4.98V to 5.02V
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
2.49V to 2.51V
3.28V to 3.32V
11.94V to 12.06V
4.98V to 5.0V
3.28V to 3.32V
5.00V to 5.04V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Total current between V1 and V2 is 30A, maximum rating.
4) Total current between V3 and V4 is 5A, maximum rating.
5) Total current between V1 and V2 is 40A, maximum rating.
Ordering Information:
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
Metric Mounting
Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric mounting
inserts are standard for single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
No RoHS suffix character required.
Add “G” as the last character of the part number.
RoHS lead solder exemption
RoHS compliant for all 6 substances
MPU150 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage - AC
Input Frequency
Hold-up Time
Continuous input range.
AC input.
After last AC line peak at 150 watts.
85
47
17.5
20
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
JUN 08, 2006 revised to JUL 14, 2006
Page 2 of 6
MPU150-4350
All other models
MPU150
NOM
0.95
100
65
MAX
UNITS
264
63
VAC
Hz
ms
3.0
ARMS
35
APK
W/VA
120
90
kHz
60
www.power-one.com
MPU150/MDU150 Series Data Sheet
MDU150 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage - DC
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Operating Frequency
Continuous input range.
Lowest DC input voltage that regulation is maintained with full rated loads.
At 150 watts, over DC input range.
36 VDC at full rated load.
Non-user serviceable internally located AC input line fuse.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Consult factory.
36
34
20
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Efficiency
Minimum Load, V1
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
Minimum load required to maintain regulation on,
Triple output models V1
V2 at maximum load.
Quad output models V1
Minimum load required on single output models.
Single output models V1
Minimum load required to maintain regulation on
Quad output models V3
V4 at maximum load.
Triple output models V3
Full load, 20 MHz bandwidth.
With 300 LFM forced air cooling. (Note 1)
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
65
75
4
3
0
0.3
0
See Model Selection Charts
150
0
3
5
Inrush Current
NOM
MAX
UNITS
75
VDC
VDC
ms
ARMS
6.4
100
70
kHz
Output Specifications
Minimum Load, V3
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
NOM
MAX
UNITS
%
A
A
Watts
%
See Model Selection Charts
500
µs
2
50
s
ms
NOTES: 1) This product is not rated for convection applications.
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
Overvoltage Protection
Latch style overvoltage protection. Available on
V1, V2, all models, and V3 on all models except
MPU150-3300.
Overload Protection
Overtemperature Protection
Output Good Signal,
Low to High Transition
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
MIN
NOM
MAX
2.5V output, V1 3.0
3.25
3.3V output, V1 4.1
4.65
3.3V output, V2 3.8
4.2
5V output, V1, V2 6.0
6.4
12V output, V2
14
16
12V output, V3
14
19
MPU150-4350G 3.3V output, V1 4.3
4.65
MPU150-S259 V1 17.0
20.5
MPU150-S262 V1 32.0
38.0
MPU150-S261 V1 58.0
62.7
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
TTL compatible signal available for V1. Pull-up resistor is 10k⍀. Signal
3.3V 3.16
3.25
is high when output is above the specified limits. Signal shall remain low
5V 4.75
4.90
for 20 milliseconds following loss of Output Good.
MPU150-S259 12V 10.5
11.9
MPU150-S262 24V 21.5
23.5
MPU150-S261 48V 43.0
47.0
TTL compatible logic signal. Time before regulation dropout due to loss of input
5
power. May be used as independent PSOK signal in redundant applications.
Accuracy of shared current with up to 6 parallel units. Single wire current share
10
on V1 and V2 with return via -Sense return.
Available on V1 and V2. Total voltage compensation for cable losses with
500
respect to the main output.
Output voltage is inhibited by application of an external high (5V) signal.
JUN 08, 2006 revised to JUL 14, 2006
Page 3 of 6
UNITS
V
V
ms
%
mV
www.power-one.com
MPU150/MDU150 Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to output per EN60950.
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
MIN
NOM
MAX
UNITS
Approved
MPU150
MDU150
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Input to output.
Per EN60950.
MPU150:
MPU150:
MDU150:
MDU150:
Line to Line
Line to Ground
Line to Line
Line to Ground
2600
1544
B
B
8
10
±2
1
2
0.5
0.5
VDC
Class
kV
V/M
kV
kV
10
Dual output MPU150 at 264 VAC
Single and triple output MPU150 at 264 VAC
MDU150 at 72 VDC
M⍀
22
1.7
(Not required by EN60950)
mA
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-Operating.
MIN
Operating Temperature
Derate linearly above 50°C by 2.5% per °C.
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
At 100% load
At 50% load
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
NOM
0
0
-55
±0.02
5
MAX
UNITS
10k
40k
50
70
85
±0.05
95
20
6
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
GPK
GRMS
Options
DESCRIPTION
NOTES
Metric Mounting
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts. Metric mounting inserts are standard for
single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
SIZE IMPACT
8.00" x 4.20" x 1.50"
(203.2mm x 106.7mm x 38.1mm)
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
JUN 08, 2006 revised to JUL 14, 2006
Page 4 of 6
www.power-one.com
MPU150/MDU150 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 1.8 lb (0.82 kg)
SINGLE OUTPUT
OUTPUTS:
8-32 SCREW
CONNECTIONS
(4PL)
+V1
RTN
INTERFACE CONNECTIONS (J300)
INPUT
L
S
V1,V.
ADJ.
J1
N
PIN
10. +S, V1
9. -S, V1
8. CURRENT SHARE, V1
7. NO CONNECTION
6. NO CONNECTION
5. NO CONNECTION
4. OUTPUT GOOD, V1
3. POWER FAIL WARNING
2. INHIBIT
1. SIGNAL GROUND
MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS
ON 2.50mm CENTERS.
MATES WITH MOLEX:
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)
M4 X 0.7, 8 PLACES.
MAXIMUM TORQUE: 3.5 IN/LBS (0.40 N/M)
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
CONNECTOR
J1
(ALL MODELS)
J300
MOLEX
SERIES
41695
41695
2139
5264-N
JUN 08, 2006 revised to JUL 14, 2006
09-50-8051
09-50-8051
09-50-3051
PIN
SERIES
6838
2478
2478
PINS
(LOOSE)
08-50-0189
08-50-0106
08-50-0106
PINS
(CHAIN)
08-50-0187
08-50-0105
08-50-0105
WIRE
GAUGE
18-20AWG
18-20AWG
18-20AWG
50-37-5103
5263
08-70-1040
08-70-1039
22-28AWG
HOUSING
Page 5 of 6
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,
WITH CLEAR FINISH
www.power-one.com
MPU150/MDU150 Series Data Sheet
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)
NOTE:
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)
ON THE FOUR BOTTOM MOUNTING HOLES.
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING
HOLES.
CONNECTOR
J1
(ALL MODELS)
J2
(TRIPLE OUTPUT)
J3
(TRIPLE OUTPUT)
J3
(QUAD OUTPUT)
J300
MOLEX
SERIES
41695
41695
2139
5051-N
5051-N
41695
41695
2139
41695
41695
2139
5264-N
JUN 08, 2006 revised to JUL 14, 2006
HOUSING
09-50-8051
09-50-8051
09-50-3051
22-01-1022
22-01-1022
09-50-8021
09-50-8021
09-50-3021
09-50-8061
09-50-8061
09-50-3061
50-37-5103
PIN
SERIES
6838
2478
2478
2759
2759
6838
2478
2478
6838
2478
2478
5263
PINS
(LOOSE)
08-50-0189
08-50-0106
08-50-0106
08-50-0114
08-65-0805
08-50-0189
08-50-0106
08-50-0106
08-50-0189
08-50-0106
08-50-0106
08-70-1040
PINS
(CHAIN)
08-50-0187
08-50-0105
08-50-0105
08-50-0113
08-65-0804
08-50-0187
08-50-0105
08-50-0105
08-50-0187
08-50-0105
08-50-0105
08-70-1039
Page 6 of 6
WIRE
GAUGE
18-20AWG
18-20AWG
18-20AWG
22-30AWG
22-30AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
22-28AWG
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,