MPD MB3000ERW Low cost, 1 x 2 inch 30w, 2:1 input range dc/dc con vert er Datasheet

MB3000ERW
Low Cost, 1 x 2 Inch
30W, 2:1 Input Range
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 30W Output Power
Input
Parameter
• 2:1 Input Voltage Range
Input Voltage Range
Conditions
Min.
24 VDC Input 18.0
48 VDC Input 36.0
24 VDC Input
48 VDC Input
(Pi) Filter
See Note 1
• 1,500 VDC Isolation
• 11 Single Output Models
Input Start Voltage
• Efficiency to 89%
Input Filter
Start-Up Time
• Compact 1 x 2 Inch Case
Output
• -40°C to +85°C Operation
Parameter
Output Voltage Accuracy
Output Trim Range
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 3
Transient Response Deviation
Output Power Protection
Temperature Coefficient
Output Short Circuit, See Note 4
• Industry Standard Pin-Out
• Low Cost
Conditions
Typ.
24.0
48.0
17.8
35.8
Max.
36.0
75.0
18.0
36.0
10
Min.
Units
VDC
VDC
mS
Typ.
±1.0
±10
±0.2
VIN = Min to Max
IOUT = 10% to 100%
±0.5
See Note 2
50
300
25% Load Step Change
±3.0
120
130
±0.02
Continuous (Autorecovery)
Max.
±3.0
Conditions
Max.
Units
VDC
M
pF
kHz
Max.
+85
+105
+125
Units
°C
°C
°C
95
%
±0.5
±1.0
120
500
±5.0
150
Units
%
%
%
%
mV P - P
µS
%
%
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
60 Seconds
500 VDC
100 kHz/0.1V
Min.
1,500
1,000
Typ.
1,000
300
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
See Mechanical Diagram (Page 4))
Aluminum Alloy With Non-Conductive Base (UL94-V0)
0.78 Oz (22g)
Remote On/Off
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Unit On
Unit Off
Off Idle Current
Conditions
See Note 5
See Note 5
Min.
3.0
0
Typ.
Max.
40.0
1.2
1.0
Units
VDC
VDC
mA
Reliability Specifications
Parameter
MTBF
Vibration
Conditions
Min.
Typ.
Max.
MIL HDBK 217F, 25°C, Gnd Benign
1.0
10 - 55 Hz, 10G, 30 Min, on X, Y & Z Axis
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
300
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Current (mA)
Voltage
Current
Full-Load No-Load
(VDC)
(mA, Max)
Current
(mA, Min)
Efficiency
(%, Typ)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection
Slow-Blow
(VDC Typ)
(µF, Max)
(mA)
Nominal
Range
MB3024S-03ERW
24
18.0 - 36.0
960
120
3.3
6,000
600
87
3.96
6,800
2,000
MB3024S-05ERW
24
18.0 - 36.0
1,460
120
5.0
6,000
600
88
6.00
6,800
3,000
MB3024S-09ERW
24
18.0 - 36.0
1,440
20
9.0
3,333
333
88
10.8
680
3,000
MB3024S-12ERW
24
18.0 - 36.0
1,440
20
12.0
2,500
250
88
15.0
680
3,000
MB3024S-15ERW
24
18.0 - 36.0
1,440
20
15.0
2,000
200
89
18.0
680
3,000
MB3024S-24ERW
24
18.0 - 36.0
1,440
20
24.0
1,250
125
89
28.0
470
3,000
MB3048S-03ERW
48
36.0 - 75.0
500
80
3.3
6,000
600
87
3.96
6,800
1,000
MB3048S-05ERW
48
36.0 - 75.0
730
80
5.0
6,000
600
88
6.00
6,800
1,500
MB3048S-12ERW
48
36.0 - 75.0
720
20
12.0
2,500
250
89
15.0
680
1,500
MB3048S-15ERW
48
36.0 - 75.0
720
20
15.0
2,000
200
89
18.0
680
1,500
MB3048S-24ERW
48
36.0 - 75.0
720
20
24.0
1,250
125
88
28.0
470
1,500
Notes:
1. Start up time is measured at nominal input and with a constant resistive
load.
2. When measuring output ripple, it is recommended that an external
ceramic capacitor (approx 1 µF to 10 µF) be placed from the +VOUT to the
-VOUT pins.
3. Transient recovery is measured to within a 1% error band for a load step
change of 25%.
4. Short circuit protection is provided by a “hiccup mode” circuit.
5. If the on/off pin is left open, the unit operates. If it is grounded, the unit
will shut off.
6. These units should not be operated with a load under 10% of full load.
Operation at no-load will not damage the unit, but they may not meet all
specifications.
7. These units should not be operated over +85°C. Exceeding +85°C may
damage the unit.
8. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Derating Curve, Output Voltage <5V
External Trim
Derating Curve, Output Voltage >5V
External Trim Notes:
On single output units, an external resistor can be used to adjust the converter
output up/down by about 10%. The connection is shown in the diagram at left. The
required resistor value is calculated by the formulas:
Trim UP = RTRIM = A $-R2 - R3
R2 A
Trim Down = RTRIM = A $-R1 - R3
R1 A
Where A =
VREF
$ R1
VTRIM - VREF
Where A = VTRIM VREF $ R2
VREF
Where RTRIM = The value of the external trim resistor
VTRIM = The amount of voltage adjustment required
The value of R1, R2, R3 and VREF are given in the table below.
292 Page Street Ste D Stoughton, MA 02072
Output Trim Resistor Values
Parameter
R1 (k)
R2 (k)
R3 (k)
VREF (V)
3.3
4.801
2.863
15.00
1.24
5.0
2.883
2.864
10.00
2.50
Output Voltage (VDC)
9.0
12
15
7.500
10.971
14.497
2.864
2.864
2.864
15.00
17.80
17.80
2.50
2.50
2.50
24
24.872
2.864
20.00
2.50
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Voltage Dips
Standard
See Note 1
EN 55022
See Note 1
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 2
EN 61000-4-4
See Note 3
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Notes:
1. All units are rated for EN 55022 (CE/RE) class A without external components.
They will meet class B with the addition of the MDCFM-xxW (or a similar discrete
filter circuit). Contact the factory for more information.
2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the MDCFM-xxW.
Contact the factory for more information.
3. To meet the requirements of EN 61000-4-5 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the MDCFM-xxW.
Contact the factory for more information.
Typical Connection
The diagram above illustrates a typical connection of the MB3000ERW 5. Recommended values for components are:
series for applications that require meeting EMC standards. The units do not Component
48 VIN
24 VIN
require external components to operate as specified. Some notes on this
MOV
S14K35
S14K60
diagram (starting with the input circuit) are:
L1
56 µH
56 µH
1. It is recommended that an external fuse be used. The recommended fuse
is shown in the model chart on page 2.
TVS
SMCJ48A
SMCJ90A
2. An external MOV is recommended on the input to protect the unit in the
C1
330 µF/50V
330 µF/100V
event of a surge. A recommended value is given in the table at right.
C2, C3
4.7 µF/50V
2.2 µF/100V
3. An external TVS is recommended on the input to protect the unit in the
L2
1.0 mH
1.0 mH
event of a voltage spike. A recommended value is given in the table at
CY1, CY2
1nF/2 kV
1nF/2 kV
right.
4. The output filtering capacitor (C4) is a high frequency, low resistance
C0
400 uF/200V
400 uF/200V
electrolytic capacitor. Care must be taken in choosing this capacitor not
to exceed the capacitive load specification for the unit. Voltage derating 6. Input noise and surge suppression modules are available for a
number of MPD DC/DC power supplies. A connection for one of
of capacitors should be 80% or above.
these modules is illustrated in the typical board layout shown at
the bottom of this page For pricing or full technical information, please contact
the factory.
Input
Vout
Output
7. In many applications simply Vin
adding input/output capaci- (VDC) Capacitor (VDC) Capacitor
tors will enhance the input
3.3
220 µF
24
100 µF
surge protection and reduce
5.0
220 µF
output ripple sufficiently. The
9.0
100 µF
100 µF
input capacitor C1 and output 48
12
100 µF
capacitor C4 shown in the
100 µF
typical connection diagram above (& board layout 15
24
47 µF
drawing below) illustrate their connection. Recommended capacitor values are given in the table.
Typical Board Layout: With External Filter/Surge Components
Typical Connection: With External Filter ModuleUnit
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Function
+Vin
-Vin
Remote On/Off
+Vout
-Vout
Trim
Adapter Plate
Mechanical Dimensions: With Optional Heatsink
All models of the MB3000x-xxERW series are available
mounted on an adapter plate similar to the one pictured at left. The
adapter plate makes it easier to mount the unit to a chassis or to a
standard DIN rail. Please contact the factory for more information.
For the heatsink option, add suffix “H” to the
model number (i.e. MB3024S-05ERW-H)
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]