XP Power CCH400PS12 5v standby output Datasheet

AC-DC
400/600 Watts
CCH400-600 Series
xppower.com
•
Baseplate Cooled
•
High Efficiency up to 90%
•
-40 °C to +85 °C Operation
•
Industrial & MIL-STD461E EMC Compliance
•
Power Fail, Inhibit, Overtemp & Current Share
•
5V Standby Output
•
3 Year Warranty
Specification
Input
General
• 90-264 VAC
• 47-400 Hz(1)
• CCH400: 4.3/2.1 A typ. at 115/230 VAC,
CCH600: 6.3/3.1 A typ. at 115/230 VAC,
full load
Inrush Current
• 60 A max at 230 VAC, 25 °C cold start
Power Factor
• >0.9
Earth Leakage Current • 0.7/1.1 mA at 115/230 VAC at 60/50 Hz
Input Protection
• Internal F10 A/250 V fuse
Input Voltage
Input Frequency
Input Current
Switching Frequency
Signals
MTBF
• 89% typical
• 3000 VAC Input to Output,
1500 VAC Input to Ground,
500 VDC Output to Ground
• 30-333 kHz PFC, 51.1 kHz main and
138 kHz standby converter
• Power Fail, Inhibit, Current Share,
Overtemperature Warning and 5 V Standby
• 300 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
•
•
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection •
Overload Protection
•
Short Circuit Protection •
Temperature
Coefficient
Overtemp. Protection
Remote Sense
Remote On/Off
Efficiency
Isolation
•
12-48 VDC
±10%
±1% V1, ±3% V2
No minimum load required
Typically 1 s
50 ms typical
20 ms min
±0.2% after 20 min warm up
±0.5% max
±1% V1, ±5% V2 max
1% typical
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Typically 1% pk-pk V1, V2 2%,
20 MHz bandwidth
110-140% Vnom, recycle input to reset
105-140% V1 only
Continuous, approximately constant
current
0.05%/˚C
• Fitted
• Compensates for 0.5 V total voltage drop
• Uncommitted isolated optocoupler diode,
powered diode inhibits V1
Notes
1. Safety approvals cover frequency 47-63 Hz.
Operating Temperature • -40 ˚C to +85 ˚C baseplate, see thermal
considerations
Cooling
• Baseplate, conduction cooling
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Shock
• MIL-STD 810F Clause 516.5 proc 1
Vibration
• MIL-STD 810F figure 514.5C-17
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
Emissions
• EN55022 level B conducted, level A
radiated, MIL-STD 461D-F, CE102
Harmonic Currents
• EN61000-3-2, class A
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
• EN61000-4-6, level 3 Perf Criteria A,
MIL-STD 461 CS114
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
• IEC60950-1 CB report, UL60950-1, TUV
EN60950-1
Equipment Protection • Class I
Class
AC-DC
CCH400/600
Models and Ratings
Output Power
411 W
411 W
409 W
411 W
Output Voltage V1
12.0 VDC
24.0 VDC
28.0 VDC
48.0 VDC
603 W
603 W
605 W
603 W
12.0 VDC
24.0 VDC
28.0 VDC
48.0 VDC
Output Current V1
34.0 A
17.0 A
14.5 A
8.5 A
50.0
25.0
21.5
12.5
Standby Supply V2
5.0 V/0.5 A
5.0 V/0.5 A
5.0 V/0.5 A
5.0 V/0.5 A
A
A
A
A
5.0 V/0.5
5.0 V/0.5
5.0 V/0.5
5.0 V/0.5
Model Number
CCH400PS12
CCH400PS24
CCH400PS28
CCH400PS48
A
A
A
A
CCH600PS12
CCH600PS24
CCH600PS28
CCH600PS48
Mechanical Details
8.43 (214.00)
- +
Voltage Adjust.
Pin
1
2
3
4
5
6
7
8
9
10
Signals Connector
Exploded View
Signal Connector
Function
Current Share
Inhibit
Overtemp. Warning
Power Fail
+Sense
-Sense
-Standby
-Standby
+Standby
+Standby
Pin 2
Pin 1
P in 10
Pin 9
4.02
(102.00)
See note 5.
0.30 (7.72)
Input Connector
3 Way AMP/Tyco
Input Connector
Connector: 10 WAY 2mm pitch p/n
MOLEX 87833-1031
Mating half: p/n MOLEX 51110-1056
Contact: p/n MOLEX 50394-8100
Pin
1
2
3
Output Terminals (M4)
Torque 8 in-lb (0.9 Nm) max
1.69
(43.00)
Input Connector
Function
Earth
Neutral
Line
Pin 3
Pin 2 Pin 1
7.84 (199.00)
4.21 (107.00)
0.59 (15.00)
Connector: 3 way AMP/Tyco
type MATE-N-LOK 1-350943-0
M4 fixings in 6 positions
Max. screw penetration to be 0.16 (4.0)
from bottom face of baseplate
Torque 13.2 in-lb (1.5 Nm) max
Mates with MATE-N-LOK 350766-1
0.177 Ø (4.50)
thru in 4 positions
Notes
3.48 (88.4)
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50);
.xxx = ±0.01 (0.25)
3. Weight 3.3 lbs (1.5 kg)
4. Connector kit available,
order part no. ‘CCH CONKIT’
5. Inhibit, overtemperature and power fail are
referenced to the OV power terminal.
2.83
(72.00)
1.18
(30.00)
0.20
(5.00)
0.27
(6.80)
8.23 (209.00)
Thermal Considerations
The baseplate must be maintainedat or below 85 °C and therefore a suitable heatsink must be selected to remove the heat from the power
supply. Details of the heatsink calculations and other considerations can be found in the longform datasheet.
50
0
-40
Some specification
parameters may not be met
Output Load (%)
100
-20
0
+85
Baseplate Temperature (ºC)
31 Jan 17