XP Power ECP225PS48-A Ac-dc power supply Datasheet

ECP225A Series
AC-DC Power Supplies
225 Watts
• Low 1” Profile
• High Power Density
• 3” by 5.0” Footprint
• 150 W Convention/ 225 W Force Cooled Ratings
• 5 V Standby and 12 V Fan Outputs
• Medical and ITE Approvals
• High Efficiency, up to 94%
• Less than 0.5 W No Load Input Power
The ECP225-A series is designed to minimize the no load power consumption and maximize
efficiency to facilitate equipment design to meet the latest environmental legislation. Approved for
medical and ITE applications, this range of single output AC/DC power supplies are packaged in an
ultra-low profile 1” height with a foot print of just 3.0” by 5.0”. The ECP225-A provides up to 225 W
force-cooled or 150 W convection-cooled leading to very high power densities of 15 W/in3 or 10
W/in3 respectively. A 5 V, 2 A standby output and a 12 V, 500 mA fan supply are included in the
design. The power supply contains two fuses and low leakage currents as required by medical
applications and is safety approved to operate in a 70 °C ambient. The low profile and safety
approvals covering ITE and medical standards along with conducted emissions to EN55011/22 level
B allow the versatile ECP225-A series to be used in a vast range of applications.
Dimensions:
ECP225A:
5.00 x 3.00 x 1.00” (127.0 x 76.2 x 25.4 mm)
Models & Ratings
Output
Voltage
Output Current
Convection-cooled
Standby Voltage
Forced-cooled(1)
12.0 V
12.50 A
18.75 A
15.0 V
10.00 A
15.00 A
24.0 V
6.25 A
9.38 A
28.0 V
5.36 A
8.04 A
48.0 V
3.10 A
4.69 A
Fan Output
Efficiency(3)
Model Number(4)
5 V/2.0 A
12 V/0.5 A
92%
ECP225PS12-A
12 V/0.5 A
92%
ECP225PS15-A
12 V/0.5 A
92%
ECP225PS24-A
5 V/2.0 A
12 V/0.5 A
92%
ECP225PS28-A
12 V/0.5 A
92%
ECP225PS48-A
Convection-cooled
Forced-cooled
5 V/1.0 A
5 V/1.0 A
5 V/1.0 A
5 V/1.0 A
5 V/1.0 A
5 V/2.0 A
5 V/2.0 A
5 V/2.0 A
Notes
1. Requires 10 CFM.
2. Measured with 20 MHz bandwidth and 10 µF electrolytic capacitor in parallel with 0.1 µF ceramic capacitor
3. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 225 W load and 230 VAC input.
1
www.xppower.com
ECP225A Series
AC-DC Power Supplies
Input
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage - Operating
85
115/230
264
VAC
Derate output from 100% at 90 VAC to 90% at 85 VAC
Input Frequency
47
50/60
63
Hz
Characteristic
Power Factor
>0.9
Input Current - Full Load
Inrush Current
Earth Leakage Current
2.2/1.1
A
115/230 VAC
120
A
80/140
No load Input Power
Input Protection
Agency approval, 47-63 Hz
230 VAC, 100% load EN61000-3-2 class A
EN6100-2-2 class C > 145W
230
µA
230 VAC cold start, 25 ºC
115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max)
0.5
W
When main output is Inhibited
F3.15 A/250 V Internal fuse fitted in line and neutral.
Output Main Output
Characteristic
Minimum
Output Voltage - V1
Typical
12
Initial Set Accuracy
Maximum
Units
Notes & Conditions
48
VDC
See Models and Ratings table
±1
Output Voltage Adjustment-V1
5
Minimum Load
0
2
10
50% load, 115/230 VAC
V1 only via potentiometer. See Mech. Details, Vfan will track
A
Start Up Delay
Hold Up Time
%
%
20/13
s
ms
115/230 VAC full load.
Min at full load, 115 VAC. Typical at 150W/ 225W
Drift
±0.02
%
After 20 min warm up
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±0.5
%
0-100% load.
Transient Response
4
%
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
Over/Undershoot
7
%
Full load
Ripple & Noise
1
% pk-pk
Overvoltage Protection
110
140
%
Overload Protection
110
170
% I nom
0.02
%/˚C
Short Circuit Protection
Vnom, recycle input to reset
Trip & Restart
Temperature Coefficient
Overtemperature Protection
Remote On/Off
20 MHz bandwidth and 10 µF electrolytic capacitator in
parallel with 0.1 µF ceramic capacitator.
°C
Measured internally, Auto Resetting
Connect pin 3 of CN2 to pin 1 to turn main output off. Connect to pin 2 or leave open to turn main output on.
Output 5 V Standby Output
Characteristic
Minimum
Output Voltage
Typical
Initial Set Accuracy
Minimum Load
Units
Notes & Conditions
VDC
±1
0
%
50% load, 115/230 VAC
A
Start Up Delay
Hold Up Time
Maximum
5.0
0.5
300
s
115/230 VAC full load.
ms
Min at full load, 115 VAC.
Drift
±0.02
%
After 20 min warm up
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±0.5
%
0-100% load.
Transient Response
4
%
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
Over/Undershoot
5
%
Full load
Ripple & Noise
1
% pk-pk
4.0
A
0.02
%/˚C
Overload Protection
3.0
Short Circuit Protection
Temperature Coefficient
Overtemperature Protection
20 MHz bandwidth and 10 µF electrolytic capacitator in
parallel with 0.1 µF ceramic capacitator
Trip & Restart
°C
www.xppower.com
Measured internally, Auto Resetting
2
ECP225A Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Maximum
Units
94
Efficiency
Isolation: Input to Output
Input to Ground
Output to Ground
%
230 VAC Full load (see fig. 1 and 2)
4000
VAC
2 MOPP
1500
VAC
1 MOPP
1500
VAC
1 MOPP
kHz
PFC
80
kHz
Main converters
15/10
W/in3
Forced/convection-cooled
300
kHrs
MIL-HDBK-217F, Notice 2 +25 °C GB
0.51(230)
lb(g)
130
70
Switching Frequency
Notes & Conditions
50
Power Density
Mean Time Between Failure
Weight
Efficiency Vs Load
Figure 1
ECP225PS12-A
12 V at 215 W
5 V at 10 W
100%
Efficiency
95%
90%
85Vac input
90Vac input
85%
115Vac input
230Vac input
80%
264Vac input
75%
70%
10
20
30
40
50
60
70
80
90
100
Load (%)
Figure 2
ECP225PS24-A
24 V at 215 W
5 V at 10 W
100%
95%
Efficiency
90%
85Vac input
90Vac input
85%
115Vac input
230Vac input
80%
264Vac input
75%
70%
10
20
30
40
50
60
70
Load (%)
3
www.xppower.com
80
90
100
ECP225A Series
AC-DC Power Supplies
Environmental
Characteristic
Maximum
Units
Operating Temperature
Minimum
-20
Typical
+70
°C
Storage Temperature
-40
+85
Cooling
10
Humidity
5
Operating Altitude
Notes & Conditions
See derating curve, fig.3
°C
CFM
Forced-cooled > 150W
95
%RH
Non-condensing
5000
m
Shock
±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27
Vibration
Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
Temperature Derating Curve
Figure 3
Output Load (%)
100
50
0
-20
0
+50
+70
Ambient Temperature (ºC)
EMC: Emissions
Standard
Test Level
Conducted
Phenomenon
EN55011/22
Class B
Criteria
Notes & Conditions
Radiated
EN55011/22
Class A
Class B with King Core
KSB RC 13 x 23 x 7 on input cable and
KSB + 25 x 12 x 5 on output cable.
Harmonic Current
EN61000-3-2
Class A
Meet Class C for loads above 145W
Voltage Functions
EN61000-3-3
EMC: Immunity
Phenomenon
Medical Device EMC
Low Voltage PSU EMC
Standard
Test Level
Criteria
IEC60601-1-2
Ed.4.0 : 2014
as below
EN61204-3
High severity level
as below
ESD
EN61000-4-2
4
A
Radiated
EN61000-4-3
3
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
3
A
Magnetic Fields
EN61000-4-8
4
A
EN55024 (100 VAC)
EN55024 (240 VAC)
Dips and Interruptions
EN60601-1-2 (100 VAC)
Dip >95% (0 VAC), 8.3 ms
A
Dip 30% (70 VAC), 416 ms
A
Dip >95% (0 VAC), 4160 ms
Dip >95% (0 VAC), 10.0 ms
B
A
Dip >95% (0 VAC), 5000 ms
Dip 100% (0 VAC), 10.0 ms
B
Dip 100% (0 VAC), 20 ms
Dip 30% (40 VAC), 500 ms
A
A
EN60601-1-2 (240 VAC)
A
A
Dip 100% (0 VAC), 5000 ms
B
Dip 100% (0 VAC), 20 ms
A
Dip 100% (0 VAC), 10.0 ms
Dip 60% (96 VAC), 100 ms
Dip 30% ( 168 VAC), 500 ms
Dip 100% (0 VAC), 5000 ms
www.xppower.com
±8kV contact, ±15kV air
A
Dip 30% (168 VAC), 500 ms
Dip 60% (40 VAC), 100 ms
Notes & Conditions
Derate Output Power to 45W
A
A
A
B
4
ECP225A Series
AC-DC Power Supplies
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
CB Report
IEC60950-1:2005 + A1:2009 + A2: 2013
Information Technology
UL
UL60950-1 (2011), CSA 22.2 No.60950-1-11 Ed 2
Information Technology
TUV
EN60950-1: 2006 + A11: 2009 + A1:2010 + A12: 2012
Information Technology
CE
LVD
Safety Agency
Safety Standard
Notes & Conditions
CB Report
IEC60601-1 Ed 3 Including Risk Management
Medical
UL
ANSI/AAMI ES60601-1: 2005 & CSA C22.2 No.6061-1:08
Medical
CE
EN60601-1:2006
Medical
Notes & Conditions
Isolation
Safety Standard
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Primary to Earth
1 x MOPP (Means of Patient Protection)
Secondary to Earth
1 x MOPP (Means of Patient Protection)
IEC60601-1 Ed 3
Mechanical Details
5.00 (127.0)
4.75 (120.6)
0.25 (6.35) Faston ground tab
VR
1
2.75
(69.9)
Q1
L1
CN2
3.00
(76.2)
11
3
CN1
1
C2
TR1
C52
2
1
CN3
Mounting Screw
Holes 4 Places
0.134 (Ø3.4 ±0.3)
0.06
(1.60)
CN2 - Output Connector
0.11 0.83
(2.80) (21.0)
CN1 - Input Connector
CN3 - Fan Connector
Pin 1
+5 V Standby
Pin 1
Neutral
Pin 1
Fan -
Pin 2
-Vout
Pin 2
Not Fitted
Pin 2
Fan +
Pin 3
Remote On/Off
Pin 3
Line
Pin 4
+Vout
Pin 5
+Vout
Pin 6
+Vout
Pin 7
+Vout
Pin 8
-Vout
Pin 9
-Vout
Pin 10
-Vout
Pin 11
-Vout
Mates with Molex housing
22-01-1022 and 2759 crimp terminals
Mates with JST housing
VHR-3N and JST Series
SVH-21T-P1.1 crimp terminals
Mounting holes marked with
must be connected to safety earth
Mates with JST housing
VHR-11N and JST Series
SVH-21T-P1.1 crimp terminals
Notes
1. All dimensions shown in inches (mm).
Tolerance: ±0.02 (0.5)
5
2. Weight: 0.51 lbs (230 g) approx.
www.xppower.com
ECP225A Series
AC-DC Power Supplies
Thermal Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below
must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component
(out of direct air flow). See Mechanical Details for component locations.
Temperature Measurements (At Maximum Ambient)
Max Temperature °C
Component
TR1 Coil
110°C
L1 Coil
120°C
Q1 Body
120°C
C2
105°C
C52
105°C
Service Life
The estimated service life of the ECP225-A is determined by the cooling arrangements and load conditions experienced in the end
application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of
a key capacitor with in the product when installed by the end application,
The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this
temperature.
Estimated Service Life vs Component Temperature
Figure 4
80000
70000
60000
Lifetime (Hrs)
50000
C52
40000
C2
30000
20000
10000
0
105
95
85
75
65
55
45
C2 + C52 Temperature (ºC)
www.xppower.com
01Oct14