AIMTEC AM30E-4812SZ 30watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM30E-Z
30Watt | DC-DC Converter
FEATURES:






Wide 2:1 Input Range
1600 VDC I/O Isolation
Adjustable Output Voltage
Soft Start
Over Current & Over Voltage Protection
Over Temperature Protection





Efficiency up to 92%
Temperature Range -40ºC to +75ºC
Remote On/Off Function
Continuous Short Circuit Protection
No Minimum Load Required
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Maximum
Capacitive Load
(uF)
Efficiency
(%)
3.3
5
5.1
12
15
3.3
5
5.1
12
15
3.3
5
5.1
12
15
8
6
6
2.5
2
8
6
6
2.5
2
8
6
6
2.5
2
20000
14000
14000
2000
2000
20000
14000
14000
2000
2000
20000
14000
14000
2000
2000
89
91
92
91
92
91
92
92
92
92
90
91
91
91
91
Output Voltage
(V)
Output Current
max (mA)
Maximum
Capacitive Load
(uF)
Efficiency
(%)
AM30E-1203SZ
9-18
AM30E-1205SZ
9-18
AM30E-1205.1SZ
9-18
AM30E-1212SZ
9-18
AM30E-1215SZ
9-18
AM30E-2403SZ
18-36
AM30E-2405SZ
18-36
AM30E-2405.1SZ
18-36
AM30E-2412SZ
18-36
AM30E-2415SZ
18-36
AM30E-4803SZ
36-75
AM30E-4805SZ
36-75
AM30E-4805.1SZ
36-75
AM30E-4812SZ
36-75
AM30E-4815SZ
36-75
Add suffix “-K” for optional heat sink
Models
Dual output
Model
Input Voltage
(V)
AM30E-1205DZ
9-18
±5
±3
±3000
89
AM30E-1212DZ
9-18
±12
±1.25
±1300
90
AM30E-1215DZ
9-18
±15
±1
±1300
91
AM30E-2405DZ
18-36
±5
±3
±3000
90
AM30E-2412DZ
18-36
±12
±1.25
±1300
91
AM30E-2415DZ
18-36
±15
±1
±1300
91
AM30E-4805DZ
36-75
±5
±3
±3000
90
AM30E-4812DZ
36-75
±12
±1.25
±1300
90
AM30E-4815DZ
36-75
±15
±1
±1300
90
Add suffix “-K” for optional heat sink
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
12
24
48
Filter
Start up time
Absolute Maximum Rating
www.aimtec.com
F 051e R12.E
12
24
48
Typical
9-18
18-36
36-75
π (Pi) Network
30
-0.7 ~ 25
-0.7 ~ 50
-0.7 ~ 100
Tel: +1 514 620 2722
1 of 5
Maximum
Units
VDC
ms
VDC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30E-Z
30Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Nominal
Peak Input Voltage time
On/Off control
Typical
Maximum
Units
100
ms
ON: 3 ~12VDC or open circuit ; OFF - 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3
12V ON/OFF
8.6 / 7.9
24V ON/OFF
17.8 / 16
VDC
48V ON/OFF
33.5 / 30.5
Under voltage lockout
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Case/Input tested voltage
Resistance
Capacitance
Typical
3 sec
3 sec
Rated
Units
1600
VDC
VDC
MOhm
pF
1600
1000
1500
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Thermal shutdown
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Voltage adjustment range (single)
Minimum Load Current
25% load on one output
100% load on second load
Maximum
%
±5
%
Zener diode clamp
150
Continuous
Auto-Recovery
115
±0.5
±0.5
±1
±0.02
100
±10
0
On Case
HL-LL
0 – 100% load
0 – 100% load
20MHz Bandwidth
Units
±1
%
ºC
%
%
%
%/oC
mV p-p
%
% of Max
General Specifications
Parameters
Conditions
Typical
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
100% load
Derating above 50
330
Maximum
-40 to +75
-40 to +125
105
2
Free Air Convection
95
Nickel coated Copper
31
2.00 x 1.00 x 0.40 inches
50.80 x 25.40 x 10.16 mm
>435,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours
1.5mm from case for 10 sec
260
250
±3
Units
KHz
o
C
o
C
o
C
o
%/ C
% RH
g
o
C
mS
%
Safety Specifications
Parameters
Agency Approvals
Standards
www.aimtec.com
F 051e R12.E
CE
EN55022 Class A
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria A (external 220uF/100V cap required)
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30E-Z
30Watt | DC-DC Converter
Safety Specifications (continued)
Parameters
IEC61000-4-5, Perf. Criteria A (external 220uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
NOTE: also designed to meet IEC/EN 60950-1
Pin Out Specifications
Pin
1
2
3
4
5
6
Single
+ V Input
- V Input
On/Off Control
+ V Output
-V Output
Trim
Dual
+ V Input
- V Input
On/Off Control
+ V Output
Common
- V Output
Dimensions
4
5
Bottom View
3
6
Diameter 1.00
(0.04)
5.08
(0.20)
10.16
(0.40)
2.54
(0.10)
10.16
(0.40)
25.40
(1.00)
1
2
10.16
(0.40)
2.54
(0.10)
5.08
(0.20)
5.08
(0.20)
50.80
(2.00)
10.16
(0.40)
Single and Dual Output Models
2.54
(0.10)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.35 (±0.014)
Case Tolerance ±0.50 (±0.02)
Dimensions with Optional Heat Sink
50.8
(2.0)
SIDE
25.4
(1.0)
16.3
(0.64)
END
Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 11.2g to
total mass (42.2g). Thermal impedance of converter is: with heat sink 10Ԩ/W and 12Ԩ/W without heat sink.
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30E-Z
30Watt | DC-DC Converter
Derating
Free Air Convection
50 ºC
100
60 ºC
Output Power %
Heatsink
80
60
Safe Operating Area
40
20
0
-40
-25
0
20
40
50
60
75
80
100
Ambient Temperature º C
Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number)
Trimming
Control ON/OFF
Positive logic turns on the module during high logic and off during low logic.
Module can be controlled by an external switch between the On/Off CTRL terminal and –Vinput terminal. The switch can be
either open collector or open drain
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30E-Z
30Watt | DC-DC Converter
Recommended Circuits
C1
100uF, 100V
L
12uH
C2
1206, 470pF, 2KV
Conducted/Radiated Emissions
Dual Output
Conducted/Radiated Emissions
Single Output
L
C1
L
+V output
+V input
+V output
+V input
C1
DC/DC
Converter
DC/DC
Converter
Load
Load
-V output
-V input
-V input
-V output
Load
Common
C2
C2
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only