ACDC 60 Watts AEM60 Series xppower.com • CEC 2008 & EISA 2007 Compliant 12 V • Worldwide Medical Approvals • 4000 VAC Isolation • Class II Construction • Single Outputs from 5 V to 48 V • High Efficiency • 3 Year Warranty Specification Input Input Voltage Input Frequency Input Current Inrush Current Input Protection No Load Input Power General • 80-264 VAC, derate output power 5% <90 VAC and 10% <85 VAC • 47-63 Hz • 1.5 A rms max • 80 A max at 240 VAC • Fitted with a T2 A/250 VAC fuse in live line • <0.5 W for ≥12 V output Output Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • Ripple & Noise • Overvoltage Protection • Overload Protection • Short Circuit Protection • Temperature • Coefficient See table See table No mimimum load required 3 s max 3 ms 8 ms minimum at 115 VAC ±1% See table 5% max deviation recovering to within 1% within 500 µs for 50% load change 1% max, 20 MHz bandwidth (see note 2) See table 120-150%, trip & restart (hiccup mode), auto-recovery Continuous ±0.05%/°C Efficiency Isolation Switching Frequency Power Density MTBF • • • • • 85%, see note 5 4000 VAC Input to Output 100 kHz typical 4.2 W/Inch3 300 kHrs to MIL-HDBK-217F at 25 ˚C, GB Environmental Operating Temperature • 0 °C to +60 °C, derate linearly from 100% load at +40 °C to 50% load at +60 °C Cooling • Convection-cooled Operating Humidity • 15-95% non-condensing Storage Temperature • -20 °C to +85 °C Operating Altitude • 3000 m Vibration • 5-500 Hz at 3 g for 10 mins on each axis Shock • 30 g with 18 ms half sine wave, 3 times on each axis EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals • • • • • • • • • EN55011 Level B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2 Level 3, Perf Criteria A EN61000-4-3 Level 2, Perf Criteria A EN61000-4-4, Level 3, Perf Criteria A EN61000-4-5 Level 3, Perf Criteria A EN61000-4-6 Level 3, Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B • UL60601-1, EN60601-1, IEC60601-1, CE Mark Output Voltage 5V 12 V 15 V 18 V 19 V 24 V 36 V 48 V Output Current Overvoltage Setpoint 6.00 5.00 4.00 3.33 3.15 2.50 1.66 1.25 6.45 14.3 17.1 20.9 20.9 28.5 40.9 53.2 A A A A A A A A - Initial Set Accuracy(1) 7.14 15.8 18.9 23.1 23.1 31.5 45.2 58.8 ± ± ± ± ± ± ± ± 4% 2% 2% 2% 2% 2% 2% 2% Regulation Line(3) ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% Load(4) ± 6% ± 5% ± 3% ± 2% ± 2% ± 2% ± 2% ± 2% Model Number AEM60US05 AEM60US12 AEM60US15 AEM60US18 AEM60US19 AEM60US24 AEM60US36 AEM60US48 Notes 1. 2. 3. 4. 5. Initial set accuracy is set at 60% full load. Add a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor to output for ripple and noise measuring at 20 MHz bandwidth. Line regulation is measured from 100 VAC to 240 VAC with full load. Load regulation is measured from 20% to 100% full load (60% ±40% full load). Minimum average of efficiencies measured at 25%, 50%, 75% and 100% load. Mechanical Details 48.00 ±0.80 (1220.0 ±20.0) 5.2 (132.1) 2.28 (58.0) LED 0.47 (12.00) 1.2 (30.5) IEC320-C8 Output connector is right angle jack 0.22 x 0.10 x 0.47 (5.5 x 2.5 x 12.0), center postive. Weight: 345 g (0.77 lbs). All dimensions in inches (mm). Tolerance: ±0.02 (±0.51) except where indicated For European mains lead order part EU-MAINS-8 For UK mains lead order part: UK-MAINS-8 For US mains lead order part US-MAINS-8 Derating Curves 100 Load (%) 80 60 40 20 0 10 20 40 50 30 Ambient Temperature (ºC) 60 70 31-Jan-12 ACDC AEM60 Models and Ratings