XP Power AEM60US12 Worldwide medical approval Datasheet

ACDC
60 Watts
AEM60 Series
xppower.com
•
CEC 2008 & EISA 2007 Compliant 12 V
•
Worldwide Medical Approvals
•
4000 VAC Isolation
•
Class II Construction
•
Single Outputs from 5 V to 48 V
•
High Efficiency
•
3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Input Protection
No Load Input Power
General
• 80-264 VAC, derate output power 5%
<90 VAC and 10% <85 VAC
• 47-63 Hz
• 1.5 A rms max
• 80 A max at 240 VAC
• Fitted with a T2 A/250 VAC fuse in live line
• <0.5 W for ≥12 V output
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection •
Overload Protection
•
Short Circuit Protection •
Temperature
•
Coefficient
See table
See table
No mimimum load required
3 s max
3 ms
8 ms minimum at 115 VAC
±1%
See table
5% max deviation recovering to within 1%
within 500 µs for 50% load change
1% max, 20 MHz bandwidth (see note 2)
See table
120-150%, trip & restart (hiccup mode),
auto-recovery
Continuous
±0.05%/°C
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
•
•
•
•
•
85%, see note 5
4000 VAC Input to Output
100 kHz typical
4.2 W/Inch3
300 kHrs to MIL-HDBK-217F
at 25 ˚C, GB
Environmental
Operating Temperature • 0 °C to +60 °C, derate linearly from 100%
load at +40 °C to 50% load at +60 °C
Cooling
• Convection-cooled
Operating Humidity
• 15-95% non-condensing
Storage Temperature • -20 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 5-500 Hz at 3 g for 10 mins on each axis
Shock
• 30 g with 18 ms half sine wave,
3 times on each axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
•
•
•
•
•
•
•
•
•
EN55011 Level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2 Level 3, Perf Criteria A
EN61000-4-3 Level 2, Perf Criteria A
EN61000-4-4, Level 3, Perf Criteria A
EN61000-4-5 Level 3, Perf Criteria A
EN61000-4-6 Level 3, Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• UL60601-1, EN60601-1, IEC60601-1,
CE Mark
Output
Voltage
5V
12 V
15 V
18 V
19 V
24 V
36 V
48 V
Output
Current
Overvoltage
Setpoint
6.00
5.00
4.00
3.33
3.15
2.50
1.66
1.25
6.45
14.3
17.1
20.9
20.9
28.5
40.9
53.2
A
A
A
A
A
A
A
A
-
Initial Set
Accuracy(1)
7.14
15.8
18.9
23.1
23.1
31.5
45.2
58.8
±
±
±
±
±
±
±
±
4%
2%
2%
2%
2%
2%
2%
2%
Regulation
Line(3)
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
Load(4)
± 6%
± 5%
± 3%
± 2%
± 2%
± 2%
± 2%
± 2%
Model
Number
AEM60US05
AEM60US12
AEM60US15
AEM60US18
AEM60US19
AEM60US24
AEM60US36
AEM60US48
Notes
1.
2.
3.
4.
5.
Initial set accuracy is set at 60% full load.
Add a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor to output for ripple and noise measuring at 20 MHz bandwidth.
Line regulation is measured from 100 VAC to 240 VAC with full load.
Load regulation is measured from 20% to 100% full load (60% ±40% full load).
Minimum average of efficiencies measured at 25%, 50%, 75% and 100% load.
Mechanical Details
48.00 ±0.80 (1220.0 ±20.0)
5.2 (132.1)
2.28
(58.0)
LED
0.47
(12.00)
1.2
(30.5)
IEC320-C8
Output connector is right angle jack 0.22 x 0.10 x 0.47 (5.5 x 2.5 x 12.0), center postive.
Weight: 345 g (0.77 lbs). All dimensions in inches (mm). Tolerance: ±0.02 (±0.51) except where indicated
For European mains lead order part EU-MAINS-8
For UK mains lead order part: UK-MAINS-8
For US mains lead order part US-MAINS-8
Derating Curves
100
Load (%)
80
60
40
20
0
10
20
40
50
30
Ambient Temperature (ºC)
60
70
31-Jan-12
ACDC
AEM60
Models and Ratings
Similar pages