LDE160-26 is a wide range DIN rail switching power supply with output power up to 160 W offering unmatched flexibility for many applications. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes it market leader for various industrial applications. LDE160-26 is Class I isolation device suitable for SELV and PELV circuitry and is designed to be mounted on DIN rail and installed inside a protective enclosure. • Single or two-phase AC input 187 - 528 VAC • Latched overload and short-circuit protection • Designed according to EN12015 and EN12016 for elevators use • High efficiency • Industrial Control • Instrumentation Equipment LDE160-26 2 LDE160-26 380 VAC (range 187 - 528 VAC) 26 VDC (Fixed) 6.0 A Specifications are measured at 25°C and 230 VAC, typical unless otherwise stated. Input AC Voltage Nominal – single or two phases Range 380 VAC 187 - 528 VAC Input Frequency 47 - 63 Hz Vin = 187 VAC Vin = 380 VAC Vin = 528 VAC Input AC Rated Current 1.8 A 1.0 A 0.8 A Inrush Peak Current ≤ 30 A Touch (Leakage) Current ≤ 0.8 mA Internal Protection Fuse External Protection on AC Line None, external fuse must be provided It is strongly recommended to provide external surge arresters (SPD) according to local regulations. Fuse 4AT or MCB 6A C curve Output Power 160 W Output Voltage 26 VDC (Fixed) Continuous Current Overload Limit 6A Latched protection Up to 10 A / 5 s Short Circuit Peak Current 25 A Load Regulation ≤ 1% Ripple & ≤ 150 mVpp Noise1 Hold up Time Vin = 230 VAC Vin = 480 VAC ≥ 33 VDC Output Overvoltage Protection Protections Status Signals Parallel Connection Efficiency ≥ 20 ms ≥ 110 ms Overload and overvoltage latched off Thermal protection Output overvoltage Green LED - DC OK Red LED - ALARM Possible for redundancy (with external ORing module) > 88% Dissipated Power 1 < 25 W Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1 μF MKP parallel capacitor. [email protected] LDE160-26 3 Operating Temperature2 - 40°C to + 50°C Storage Temperature - 40°C to + 80°C Derating - 15 W/ºC over 45ºC Humidity Non-condensing 5 – 95% RH Life Time Expectancy At 25°C ambient, full load 77 726 h (8.8 years) Overvoltage Category Pollution Degree EN50178 IEC60664-1 UL508 (reference) EN60950 (reference) EN50178 (reference) EN55011 (CISPR11) EN55022 (CISPR22) EN12015 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-11 EN12016 Input to output Input to ground Output to ground III 2 Safety Standards & Approvals Emission: EMC Standards Immunity: Isolation Voltage Class A Class A Class A Level 3 Level 3 Level 3 Level 3 Level 2 4.2 kVDC 2.2 kVDC 0.75 kVDC Protection Degree EN60529 IP20 Vibration Sinusoidal IEC 60068-2-6 (5-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 2Hours / axis (X,Y,Z) Shock IEC 60068-2-27 (30g 6ms, 20g 11ms; 3 bumps / direction, 18 bumps total) Weight 0.5 kg Dimensions (W x H x D) 108.5 x 110.0 x 74.5 mm Connection Terminals Screw type (24 - 12 AWG) 2.5 mm² Case Material Aluminum IEC 60715/H15/TH35-7.5(-15) Mounting Rail Rail Mounting Information Vertical, allow 10mm spacing between adjacent items NOTES: Technical parameters are typical, measured in laboratory environment at 25ºC and 400 VAC / 50 Hz. Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range. Contact factory for details. 2 Start-up type tested: - 40°C, possible at nominal voltage with load derating. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00850_AA Asia-Pacific +86 755 298 85888 LDE160-26 4 Figure 1. Mechanical Drawing INPUT CONNECTION Single phase: L1 = Line N = Neutral I = Earth ground Two phases: L1 = Phase 1 L2 = Phase 2 I = Earth ground OUTPUT CONNECTION + = Positive DC - = Negative DC NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. [email protected]