Bel LDE160-26 Instrumentation equipment Datasheet

LDE160-26 is a wide range DIN rail switching power supply with
output power up to 160 W offering unmatched flexibility for many
applications.
Its compact size, high efficiency, excellent reliability together with
easy installation due to pluggable connectors makes it market leader
for various industrial applications.
LDE160-26 is Class I isolation device suitable for SELV and PELV
circuitry and is designed to be mounted on DIN rail and installed inside
a protective enclosure.
•
Single or two-phase AC input 187 - 528 VAC
•
Latched overload and short-circuit protection
•
Designed according to EN12015 and EN12016 for elevators use
•
High efficiency
•
Industrial Control
•
Instrumentation Equipment
LDE160-26
2
LDE160-26
380 VAC (range 187 - 528 VAC)
26 VDC (Fixed)
6.0 A
Specifications are measured at 25°C and 230 VAC, typical unless otherwise stated.
Input AC Voltage
Nominal – single or two phases
Range
380 VAC
187 - 528 VAC
Input Frequency
47 - 63 Hz
Vin = 187 VAC
Vin = 380 VAC
Vin = 528 VAC
Input AC Rated Current
1.8 A
1.0 A
0.8 A
Inrush Peak Current
≤ 30 A
Touch (Leakage) Current
≤ 0.8 mA
Internal Protection Fuse
External Protection on AC Line
None, external fuse must be provided
It is strongly recommended to provide external
surge arresters (SPD) according to local regulations.
Fuse 4AT or MCB 6A C curve
Output Power
160 W
Output Voltage
26 VDC (Fixed)
Continuous Current
Overload Limit
6A
Latched protection
Up to 10 A / 5 s
Short Circuit Peak Current
25 A
Load Regulation
≤ 1%
Ripple &
≤ 150 mVpp
Noise1
Hold up Time
Vin = 230 VAC
Vin = 480 VAC
≥ 33 VDC
Output Overvoltage Protection
Protections
Status Signals
Parallel Connection
Efficiency
≥ 20 ms
≥ 110 ms
Overload and overvoltage latched off
Thermal protection
Output overvoltage
Green LED - DC OK
Red LED - ALARM
Possible for redundancy (with external ORing
module)
> 88%
Dissipated Power
1
< 25 W
Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1 μF MKP parallel capacitor.
[email protected]
LDE160-26
3
Operating Temperature2
- 40°C to + 50°C
Storage Temperature
- 40°C to + 80°C
Derating
- 15 W/ºC over 45ºC
Humidity
Non-condensing
5 – 95% RH
Life Time Expectancy
At 25°C ambient, full load
77 726 h (8.8 years)
Overvoltage Category
Pollution Degree
EN50178
IEC60664-1
UL508 (reference)
EN60950 (reference)
EN50178 (reference)
EN55011 (CISPR11)
EN55022 (CISPR22)
EN12015
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-11
EN12016
Input to output
Input to ground
Output to ground
III
2
Safety Standards & Approvals
Emission:
EMC Standards
Immunity:
Isolation Voltage
Class A
Class A
Class A
Level 3
Level 3
Level 3
Level 3
Level 2
4.2 kVDC
2.2 kVDC
0.75 kVDC
Protection Degree
EN60529
IP20
Vibration Sinusoidal
IEC 60068-2-6
(5-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 2Hours / axis (X,Y,Z)
Shock
IEC 60068-2-27
(30g 6ms, 20g 11ms; 3 bumps / direction, 18 bumps total)
Weight
0.5 kg
Dimensions (W x H x D)
108.5 x 110.0 x 74.5 mm
Connection Terminals
Screw type (24 - 12 AWG)
2.5 mm²
Case Material
Aluminum
IEC 60715/H15/TH35-7.5(-15)
Mounting Rail
Rail Mounting Information
Vertical, allow 10mm spacing between adjacent items
NOTES:
Technical parameters are typical, measured in laboratory environment at 25ºC and 400 VAC / 50 Hz.
Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range.
Contact factory for details.
2
Start-up type tested: - 40°C, possible at nominal voltage with load derating.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2017 Bel Power Solutions & Protection
BCD.00850_AA
Asia-Pacific
+86 755 298 85888
LDE160-26
4
Figure 1. Mechanical Drawing
INPUT CONNECTION
Single phase:
L1 = Line
N = Neutral
I = Earth ground
Two phases:
L1 = Phase 1
L2 = Phase 2
I = Earth ground
OUTPUT CONNECTION
+ = Positive DC
- = Negative DC
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
[email protected]