MORNSUN FB2409S-1W Dual/single output dc-dc converter Datasheet

EA_S-1W & FB_S-1W Series
1W, FIXED INPUT, 5200V ISOLATED & UNREGULATED
DUAL/SINGLE OUTPUT DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
5.2KVDC Isolation
SIP Package
Temperature Range: -40°C to +85°C
No Heat Sink Required
Internal SMD Construction
Low Isolation Capacitance
No External Component Required
Industry Standard Pinout
RoHS Compliance
& FB_S-1W
Series
Output
Voltage (VDC)
Efficiency
(%, Typ)
Current (mA)
Voltage
(VDC)
Max
Min
EA0505S-1W
±5
±100
±10
70
EA0509S-1W
±9
±56
±6
71
EA0512S-1W
±12
±42
±5
72
EA0515S-1W
±15
±33
±4
74
5
200
20
70
FB0509S-1W
9
111
12
71
FB0512S-1W
12
83
9
72
FB0515S-1W
15
67
7
74
EA1205S-1W
±5
±100
±10
70
EA1209S-1W
±9
±56
±6
72
Nominal
FB0505S-1W
APPLICATIONS
The EA_S-1W
Input
Part
Number
5
Range
4.5-5.5
are
EA1212S-1W
±12
±42
±5
74
specially designed for applications where a
EA1215S-1W
±15
±33
±4
75
group of polar power supplies are isolated from
FB1205S-1W
5
200
20
70
the input power supply in a distributed power
FB1209S-1W
9
111
12
72
supply system on a circuit board.
FB1212S-1W
12
83
9
74
These products apply to:
FB1215S-1W
15
67
7
75
1) Where the voltage of the input power supply
EA2405S-1W
±5
±100
±10
72
EA2409S-1W
±9
+56
±6
74
EA2412S-1W
±12
±42
±5
76
±15
±33
±4
78
5
200
20
72
FB2409S-1W
9
111
12
74
FB2412S-1W
12
83
9
76
FB2415S-1W
15
67
7
78
is fixed (voltage variation ≤ ±10%);
2) Where isolation is necessary between input
and output (isolation voltage ≤5200VDC);
EA2415S-1W
3) Where the regulation of the output voltage
and
the
output
ripple
noise
are
not
demanding.
Such as: purely digital circuits, ordinary low
FB2405S-1W
12
24
10.8-13.2
21.6-26.4
frequency analog circuits, and IGBT power
device driving circuits.
ISOLATION SPECIFICATIONS
Item
Test Conditions
Isolation voltage
Tested for 1 minute and 1mA max
5200
Min
Isolation resistance
Test at 1000VDC
1000
Isolation capacitance
MODEL SELECTION
EA0505S-1W
Rat ed Power
Pa ck a g e St yle
O u t p u t Vo lt a g e
In p u t Volta g e
Pro du c t S e rie s
Max
Units
VDC
MΩ
10
pF
COMMON SPECIFICATIONS
Item
Test Conditions
Min
Typ
Storage humidity
Operating temperature
Storage temperature
Lead temperature
Short circuit protection*
MORNSUN Science & Technology co., Ltd.
Max
Units
95
%
-40
85
-55
125
1.5mm from case for 10 seconds
°C
300
Temp. rise at full load
Address: 2th floor 6th building, Hangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
http://www.mornsun-power.com
Typ
15
5V input voltage
25
1
12V/24V input voltage
Second
Continuous
Cooling
Free air convection
Case material
Plastic(UL94-V0)
MTBF
3500
Weight
K hours
4.2
g
*supply voltage must be discontinued at the end of short circuit duration.
MORNSUN reserves the copyright
Specifications subject to change without notice.
EA_S-1W & FB_S-1W
A/1-2008
Page 1 of 2
OUTPUT SPECIFICATIONS
Item
Output power
Line regulation
Recommended testing and application circuit
Test conditions
Min
0.1
If you want to further decrease the input/output
Max
Units
1
W
±1.2
12.8
15
%
8.3
15
6.8
15
6.3
15
See tolerance envelope graph
0.03
%/°C
150
200
mVp-p
250
KHz
42
For Vin change of 1%
10% to 100% load(5V output)
10% to 100% load (9V output)
Load regulation
10% to 100% load (12V output)
10% to 100% load (15V output)
Output voltage accuracy
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
(5V input)
Full load,
Switching frequency
nominal input
(others input)
Typ
ripple,
“LC”
an
filtering
network
may
be
connected to the input and output ends of the
DC/DC converter, see (Figure 1).
Dual Output
L
L
+Vo
Vin
Cout
DC DC
Cin
0V
L Cout
GND
-Vo
Single Output
L
L
+Vo
Vin
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2. Dual output models unbalanced load: ±5%.
Cout
DC DC
Cin
GND
0V
(Figure 1)
It should also be noted that the inductance and
the frequency of the “LC” filtering network should
be staggered with the DC/DC frequency to avoid
TYPICAL CHARACTERISTICS
mutual interference. However, the capacitance of
the output filter capacitor must be proper. If the
capacitance is too big, a startup problem might
arise. For every channel of output, provided the
safe and reliable operation is ensured, the
greatest capacitance of its filter capacitor sees
(Table 1).
EXTERNAL CAPACITOR TABLE (TABLE 1)
Ambient Temperature ( C )
OUTLINE DIMENSIONS & PIN CONNECTIONS
First A ngle Projection
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
1 2
Cin
(uF)
5
12
24
-
4.7
2.2
1
-
Single Cout
Vout (uF)
(VDC)
5
10
9
4.7
12
2.2
15
1
Dual
Vout
(VDC)
±5
±9
±12
±15
Cout
(uF)
4.7
2.2
1
1
It’s not recommended to connect any external
capacitor in the application field with less than 0.5
Dual Output
5 6
Vin
(VDC)
watt output.
1
2
5 6
Output Voltage Regulation and Over-voltage
Protection Circuit
The simplest device for output voltage
7
regulation,
Single Output
over-voltage
and
over-current
protection is a linear voltage regulator with
overheat protection that is connected to the input
1
2
5
or output end in series (Figure 2).
7
Dual Output
FOOTPRINT DETAILS
Pin
Note:
Unit:mm(inch)
Pin section: 0. 50*0.30mm(0.020*0.012inch)
Pin tolerances: 0.10mm( 0.004inch)
General tolerances: 0.25mm( 0.010inch)
Singles
Vin
REG
Duals
GND
1
2
5
6
7
+Vout
REG
-Vout
REG
+Vout
0V
Single Output
Vin
REG
GND
DC DC
0V
(Figure 2)
APPLICATION NOTE
Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum
output load is not less than 10% of the full load, and that this product should never be
operated under no load! If the actual output power is very small, please connect a resistor
with proper resistance at the output end in parallel to increase the load, or use our company’s
products with a lower rated output power.
MORNSUN reserves the copyright
REG
DC DC
Overload Protection
Under normal operating conditions, the output
circuit of these products has no protection
against overload. The simplest method is to
connect a self-recovery fuse in series at the input
end or add a circuit breaker to the circuit.
No parallel connection or plug and play.
Specifications subject to change without notice.