MPD MB5024S24RW Mb5000rw sery Datasheet

MB5000RW Series
Compact, 1 x 2 Inch
50W, 2:1 Input Range
DC/DC Con
verters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 50W Output Power
Input
Parameter
Conditions
Min.
12 VDC Input
24 VDC Input
48 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
LC Filter
See Note 1
Input Start Voltage
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
Input Shutdown Voltage
• 15 Standard Models
• Efficiency to 92%
Input Filter
Start-Up Time
• Compact 1 x 2 Inch Case
Output
• Wide Temp Operation
• Industry Standard Pin-Out
• Low Cost
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Conditions
Ripple & Noise, See Note 2
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Over Temperature Protection
Output Power Protection
Output Short Circuit, See Note 4
Min.
Typ.
Units
VDC
8.3
16.5
33.0
VDC
30
mS
Typ.
VIN = Min to Max
Min Load to Full Load
3.3 & 5.0 Vout Models
12, 15 & 24 Vout Models
250
±3.0
25% Load Step Change
Max.
9.0
18.0
36.0
Max.
±1.0
±0.5
±0.5
100
150
±5.0
±0.02
Shutdown Temperature
110
150
Continuous (Autorecovery)
Units
%
%
%
mV P - P
mV P - P
µSec
%
%/°C
°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
See Note 5
Min.
1,500
1,000
Typ.
Max.
2,200
320
Units
VDC
M⍀
pF
kHz
Environmental
Parameter
Operating Temperature Range,
Ambient Without Heatsink
Operating Temperature Range,
Ambient With Heatsink
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size, See Note On Page 4
Case Material
Weight
Conditions
MB50xxS-03RW
MB5024S-05RW, -12RW, -15RW
MB5048S-05RW, -12RW, -15RW
MB5012S-12RW, -15RW, -24RW
MB5024S-24RW, MB5048S-24RW
MB5012S-05RW
MB50xxS-03RW
MB5024S-05RW, -12RW, -15RW
MB5048S-05RW, -12RW, -15RW
MB5012S-12RW, -15RW, -24RW
MB5024S-24RW, MB5048S-24RW
MB5012S-05RW
Case
Min.
Typ.
-40
+25
Max.
+56
Units
+53
°C
+46
+38
+64
+62
-40
+25
°C
+56
-50
Free Air Convection
RH, Non-condensing
+49
+105
+125
°C
°C
95
%
2.0 x 1.0 x 0.43 Inches (50.8 x 25.4 x 11.0 mm)
Metal with Non-Conductive Base
1.06 Oz (30g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
224.7
Typ.
Max.
Units
kHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
-0.7
Typ.
Max.
25.0
50.0
100.0
260.0
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
12
12
12
12
12
24
24
24
24
24
48
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
MB5012S-03RW
MB5012S-05RW
MB5012S-12RW
MB5012S-15RW
MB5012S-24RW
MB5024S-03RW
MB5024S-05RW
MB5024S-12RW
MB5024S-15RW
MB5024S-24RW
MB5048S-03RW
MB5048S-05RW
MB5048S-12RW
MB5048S-15RW
MB5048S-24RW
Output
Current (mA)
Voltage
Current
Current
Full-Load No-Load
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
24.0
3.3
5.0
12.0
15.0
24.0
3.3
5.0
12.0
15.0
24.0
10,000
10,000
4,170
3,330
2,080
10,000
10,000
4,170
3,330
2,080
10,000
10,000
4,170
3,330
2,080
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3,090
4,630
4,580
4,580
4,570
1,550
2,260
2,260
2,260
2,290
770
1,130
1,130
1,130
1,150
85
110
160
160
250
50
70
85
85
110
35
45
50
50
60
Efficiency
(%, Typ)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection (µF
Slow-Blow
Max)
(VDC)
89
90
91
91
91
89
92
92
92
91
89
92
92
92
91
3.9
6.2
15.0
18.0
30.0
3.9
6.2
15.0
18.0
30.0
3.9
6.2
15.0
18.0
30.0
(A)
25,800
17,000
2,900
1,900
750
25,800
17,000
2,900
1,900
750
25,800
17,000
2,900
1,900
750
10.0
10.0
10.0
10.0
10.0
5.0
5.0
5.0
5.0
5.0
2.5
2.5
2.5
2.5
2.5
Notes:
For heatsink option, add suffix “H” to model number (i.e. MB5012S-05RW-H)
1. Start up time is measured at nominal input and with a constant resistive load.
2. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in parallel from the +VOUT to the -VOUT pins.
3. Transient recovery is measured to within a 1% error band for a load step change of 25%.
4. Short circuit protection is provided by a “hiccup mode” circuit.
5. The switching frequency for 24 VDC output models is 285 kHz.
6. Operation at no-load will not damage these units.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating.
External Trim
An external resister may be added to adjust the converter
output.
To adjust the output UP, connect a 5%, 3W resistor between
the minus output pin (5) and the Vout trim pin (6). To adjust
the output DOWN, connect a 5%, 3W resistor between the plus
output pin (4) and the Vout trim pin (6).
The trim table at right gives suggested resistor values for
this adjustment.
MB50xxS-03RW
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
72.61
32.55
19.20
12.52
8.51
5.84
3.94
2.51
1.39
0.50
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
60.84
27.40
16.25
10.68
7.34
5.11
3.51
2.32
1.39
0.65
Volts
k⍀
MB50xxS-05RW
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
138.88
62.41
36.92
24.18
16.53
11.44
7.79
5.06
2.94
1.24
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
106.87
47.76
28.06
18.21
12.30
8.36
5.55
3.44
1.79
0.48
Volts
k⍀
MB50xxS-12RW
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
413.55
184.55
108.22
70.05
47.15
31.88
20.98
12.80
6.44
1.35
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
351.00
157.50
93.00
60.75
41.40
28.50
19.29
12.37
7.00
2.70
Volts
k⍀
MB50xxS-15RW
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
530.73
238.61
141.24
92.56
63.35
43.87
29.96
19.53
11.41
4.92
Volts
k⍀
Trim Up
Vout
RUP
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
422.77
189.89
112.26
73.44
50.15
34.63
23.54
15.22
8.75
3.58
Volts
k⍀
MB50xxS-24RW
Trim Down
Vout
VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90
RDOWN
333.39
148.80
87.26
56.50
38.04
25.73
16.94
10.35
5.22
1.12
Volts
k⍀
Trim Up
Vout
RUP
Volts
k⍀
VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10
243.70
108.50
63.43
40.90
27.38
18.37
11.93
7.10
3.34
0.34
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
All units should meet EN 55022 (CE/RE) class A/B
with the simple external circuit shown; using the
component values given in the table.
To meet the requirements of EN 61000-4-4 and
EN 61000-4-5, the value of C1 should be changed
to 330 µF/200V. Contact the factory for more
information.
Parameter
Standard
Model
C1
MB5012x-xxRW 22 µF/25V 1210 MLCC
EN55022 Class A MB5024x-xxRW 3.3 µF/50V 1210 MLCC
MB5048x-xxRW 2.2 µF/100V 1210 MLCC
EN55022 Class B MB50xxS-xxRW 3.3 µF/100V 1210/X7S
C2
------3.3 µF/100V 1210/X7S
L1
------1 mH
C3
------1,000 pF/2kV 1808 X7R
C4
------1,000 pF/2kV 1808 X7R
Standard
Radiated Emissions
Conducted Emissions
ESD
RS
EFT, See Notes
Surge, See Notes
CS
EN 55022
Class A/B
EN 55022
Class A/B
EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact
EN 61000-4-3
Criteria A; 10V/m
EN 61000-4-4
Criteria A; ±2 kV
EN 61000-4-5
Criteria A; ±1 kV
EN 61000-4-6
Criteria A; 10 V/m
Derating Curves
MB50xxS-03RW Without Heatsink
MB50xxS-03RW With Heatsink
MB5024/48S-05RW, -12RW, -15RW Without Heatsink
MB5024/48S-05RW, -12RW, -15RW With Heatsink
MB5012S-12RW, 15RW & MB50xxS-24RW Without Heatsink
MB5012S-12RW, 15RW & MB50xxS-24RW With Heatsink
MB5012S-05RW Without Heatsink
MB5012S-05RW With Heatsink
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Remote On/Off
Parameter
Min
Supply On
Supply Off
Standby Input Current
Control Common
Control Input Current (ON)
Control Input Current (OFF)
3.5
0.0
Typ
Max
Units
12.0
1.2
VDC
VDC
2.5
mA
Referenced to Negative Input (pin 2)
0.5
mA
-0.5
mA
Applying a signal to pin 3 will turn the unit ON/OFF. If the
pin is left open, the unit operates. If grounded, the unit will
shut off. The specifications for the ON/OFF function are
given in the table at left.
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Mechanical Dimensions: With Optional Heatsink
Function
+Vin
-Vin
Remote On/Off
+Vout
-Vout
Trim
For the heatsink option, add suffix “H” to the
model number (i.e. MB5048S-12RW-H)
Notes:
Not
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Heatsink is black, anodized aluminum
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages