MT9044 T1/E1/OC3 System Synchronizer Advance Information DS5058 Features • • • • • • • • • • • • Supports AT&T TR62411 and Bellcore GR-1244-CORE Stratum 3, Stratum 4 Enhanced and Stratum 4 timing for DS1 interfaces Supports ITU-T G.812 Type IV clocks for 1,544 kbit/s interfaces and 2,048 kbit/s interfaces Supports ETSI ETS 300 011, TBR 4, TBR 12 and TBR 13 timing for E1 interfaces Selectable 1.544MHz, 2.048MHz or 8kHz input reference signals Provides C1.5, C2, C3, C4, C6, C8, C16, and C19 (STS-3/OC3 clock divided by 8) output clock signals Provides 5 different styles of 8 KHz framing pulses Holdover frequency accuracy of 0.05 PPM Holdover indication Attenuates wander from 1.9Hz Provides Time Interval Error (TIE) correction Accepts reference inputs from two independent sources JTAG Boundary Scan • September 1999 Ordering Information MT9044AP 44 Pin PLCC MT9044AL 44 Pin MQFP -40 to +85 °C Description The MT9044 T1/E1/OC3 System Synchronizer contains a digital phase-locked loop (DPLL), which provides timing and synchronization signals for multitrunk T1 and E1 primary rate transmission links and STS-3/0C3 links. The MT9044 generates ST-BUS clock and framing signals that are phase locked to either a 2.048MHz, 1.544MHz, or 8kHz input reference. The MT9044 is compliant with AT&T TR62411 and Bellcore GR-1244-CORE Stratum 3, Stratum 4 Enhanced, and Stratum 4; and ETSI ETS 300 011. It will meet the jitter/wander tolerance, jitter/wander transfer, intrinsic jitter/wander, frequency accuracy, capture range, phase change slope, holdover frequency and MTIE requirements for these specifications. Applications • ISSUE 3 Synchronization and timing control for multitrunk T1,E1 and STS-3/OC3 systems ST-BUS clock and frame pulse sources OSCi OSCo VDD TCLR Master Clock TCK TDI TMS TRST TDO IEEE 1149.1a PRI SEC Reference Select MUX TIE Corrector Circuit TIE Corrector Enable C19o C1.5o C3o C2o C4o C6o C8o C16o F0o F8o F16o RSP TSP Virtual Reference DPLL Selected Reference Reference Select VSS Output Interface Circuit State Select State Select Input Impairment Monitor Feedback RSEL LOS1 LOS2 Automatic/Manual Control State Machine Guard Time Circuit Frequency Select MUX ACKi APLL ACKo MS1 MS2 RST HOLDOVER GTo GTi FS1 FS2 Figure 1 - Functional Block Diagram 1 MT9044 VDD OSCo OSCi VSS F16o RSP F0o TSP F8o C1.5o AVDD PRI SEC TRST TCLR TCK VSS TMS RST TDI FS1 FS2 PRI SEC TRST TCLR TCLK VSS TMS RST TDI FS1 FS2 Advance Information 6 5 4 3 2 1 44 43 42 41 40 44 43 42 41 40 39 38 37 36 35 34 7 8 9 10 11 12 13 14 15 16 17 39 38 37 36 35 34 33 32 31 30 29 MT9044 TEST RSEL MS1 MS2 TDO LOS1 LOS2 GTo VSS GTi HOLDOVER 1 2 3 4 5 6 7 8 9 10 11 MT9044AL 33 32 31 30 29 28 27 26 25 24 23 TEST RSEL MS1 MS2 TDO LOS1 LOS2 GTo VSS GTi HOLDOVER 12 13 14 15 16 17 18 19 20 21 22 ACKi VSS ACKo C8o C16o C6o VDD C3o C2o C4o C19o ACKi VSS ACKo C8o C16o C6o VDD 18 19 20 21 22 23 24 25 26 27 28 C3o C2o C4o C19o VDD OSCo OSCi VSS F16o RSP F0o TSP F8o C1.5o AVDD Figure 2 - Pin Connections Pin Description 2 Pin # Pin # PLCC MQFP Name 1,10, 39,4,17 23,31 ,25 VSS Ground. 0 Volts. Test Clock (TTL Input): Provides the clock to the JTAG test logic. This pin is internally pulled up to VDD. Description 2 40 TCK 3 41 TCLR TIE Circuit Reset (TTL Input): A logic low at this input resets the Time Interval Error (TIE) correction circuit resulting in a re-alignment of input phase with output phase as shown in Figure 19. The TCLR pin should be held low for a minimum of 300ns. This pin is internally pulled down to VSS. 4 42 TRST Test Reset (TTL Input): Asynchronously initializes the JTAG TAP controller by putting it in the Test-Logic-Reset state. This pin is internally pulled down to VSS. 5 43 SEC Secondary Reference (TTL Input). This is one of two (PRI & SEC) input reference sources (falling edge) used for synchronization. One of three possible frequencies (8kHz, 1.544MHzMHz, or 2.048MHz) may be used. The selection of the input reference is based upon the MS1, MS2, LOS1, LOS2, RSEL, and GTi control inputs (Automatic or Manual). This pin is internally pulled up to VDD. 6 44 PRI Primary Reference (TTL Input). See pin description for SEC. This pin is internally pulled up to VDD. 7,28 1,22 VDD Positive Supply Voltage. +5VDC nominal. 8 2 OSCo Oscillator Master Clock (CMOS Output). For crystal operation, a 20MHz crystal is connected from this pin to OSCi, see Figure 10. For clock oscillator operation, this pin is left unconnected, see Figure 9. 9 3 OSCi Oscillator Master Clock (CMOS Input). For crystal operation, a 20MHz crystal is connected from this pin to OSCo, see Figure 10. For clock oscillator operation, this pin is connected to a clock source, see Figure 9. 11 5 F16o Frame Pulse ST-BUS 8.192 Mb/s (CMOS Output). This is an 8kHz 61ns active low framing pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS operation at 8.192 Mb/s. See Figure 20. MT9044 Advance Information Pin Description (continued) Pin # Pin # PLCC MQFP Name Description 12 6 RSP Receive Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing pulse, which marks the end of an ST-BUS frame. This is typically used for connection to the Siemens MUNICH-32 device. See Figure 21. 13 7 F0o Frame Pulse ST-BUS 2.048Mb/s (CMOS Output). This is an 8kHz 244ns active low framing pulse, which marks the beginning of an ST-BUS frame. This is typically used for ST-BUS operation at 2.048Mb/s and 4.096Mb/s. See Figure 20. 14 8 TSP Transmit Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing pulse, which marks the beginning of an ST-BUS frame. This is typically used for connection to the Siemens MUNICH-32 device. See Figure 21. 15 9 F8o Frame Pulse (CMOS Output). This is an 8kHz 122ns active high framing pulse, which marks the beginning of a frame. See Figure 20. 16 10 C1.5o Clock 1.544MHz (CMOS Output). This output is used in T1 applications. 17 11 AVdd Analog Vdd. +5VDC nominal. 18 12 C3o Clock 3.088MHz (CMOS Output). This output is used in T1 applications. 19 13 C2o Clock 2.048MHz (CMOS Output). This output is used for ST-BUS operation at 2.048Mb/s. 20 14 C4o Clock 4.096MHz (CMOS Output). This output is used for ST-BUS operation at 2.048Mb/s and 4.096Mb/s. 21 15 C19o Clock 19.44MHz (CMOS Output). This output is used in OC3/STS3 applications. 22 16 ACKi Analog PLL Clock Input (CMOS Input). This input clock is a reference for an internal analog PLL. This pin is internally pulled down to VSS. 24 18 ACKo Analog PLL Clock Output (CMOS Output). This output clock is generated by the internal analog PLL. 25 19 C8o Clock 8.192MHz (CMOS Output). This output is used for ST-BUS operation at 8.192Mb/s. 26 20 C16o Clock 16.384MHz (CMOS Output). This output is used for ST-BUS operation with a 16.384MHz clock. 27 21 C6o Clock 6.312 Mhz (CMOS Output). This output is used for DS2 applications. 29 23 30 24 GTi Guard Time (Schmitt Input). This input is used by the MT9044 state machine in both Manual and Automatic modes. The signal at this pin affects the state changes between Primary Holdover Mode and Primary Normal Mode, and Primary Holdover Mode and Secondary Normal Mode. The logic level at this input is gated in by the rising edge of F8o. See Tables 4 and 5. 32 26 GTo Guard Time (CMOS Output). The LOS1 input is gated by the rising edge of F8o, buffered and output on GTo. This pin is typically used to drive the GTi input through an RC circuit. 33 27 LOS2 Secondary Reference Loss (TTL Input). This input is normally connected to the loss of signal (LOS) output signal of a Line Interface Unit (LIU). When high, the SEC reference signal is lost or invalid. LOS2, along with the LOS1 and GTi inputs control the MT9044 state machine when operating in Automatic Control. The logic level at this input is gated in by the rising edge of F8o. This pin is internally pulled down to VSS. HOLDOVER Holdover (CMOS Output). This output goes to a logic high whenever the digital PLL goes into holdover mode. 3 MT9044 Advance Information Pin Description (continued) Pin # Pin # PLCC MQFP 4 Name Description 34 28 LOS1 Primary Reference Loss (TTL Input). Typically, external equipment applies a logic high to this input when the PRI reference signal is lost or invalid. The logic level at this input is gated in by the rising edge of F8o. See LOS2 description. This pin is internally pulled down to VSS. 35 29 TDO Test Serial Data Out (TTL Output). JTAG serial data is output on this pin on the falling edge of TCK. This pin is held in high impedance state when JTAG scan is not enable. 36 30 MS2 Mode/Control Select 2 (TTL Input). This input, in conjunction with MS1, determines the device’s mode (Automatic or Manual) and state (Normal, Holdover or Freerun) of operation. The logic level at this input is gated in by the rising edge of F8o. See Table 3. 37 31 MS1 Mode/Control Select 1 (TTL Input). The logic level at this input is gated in by the rising edge of F8o. See pin description for MS2. This pin is internally pulled down to VSS. 38 32 RSEL Reference Source Select (TTL Input). In Manual Control, a logic low selects the PRI (primary) reference source as the input reference signal and a logic high selects the SEC (secondary) input. In Automatic Control, this pin must be at logic low. The logic level at this input is gated in by the rising edge of F8o. See Table 2. This pin is internally pulled down to VSS. 39 33 TEST Test (TTL Input). This input is normally tied low. When pulled high, it enables internal test modes. This pin is internally pulled down to VSS. 40 34 FS2 Frequency Select 2 (TTL Input). This input, in conjunction with FS1, selects which of three possible frequencies (8kHz, 1.544MHz, or 2.048MHz) may be input to the PRI and SEC inputs. See Table 1. 41 35 FS1 Frequency Select 1 (TTL Input). See pin description for FS2. 42 36 TDI Test Serial Data In (TTL Input). JTAG serial test instructions and data are shifted in on this pin. This pin is internally pulled up to VDD. 43 37 RST Reset (Schmitt Input). A logic low at this input resets the MT9044. To ensure proper operation, the device must be reset after changes to the method of control, reference signal frequency changes and power-up. The RST pin should be held low for a minimum of 300ns. While the RST pin is low, all frame and clock outputs are at logic high. Following a reset, the input reference source and output clocks and frame pulses are phase aligned as shown in Figure 19. 44 38 TMS Test Mode Select (TTL Input). JTAG signal that controls the state transitions of the TAP controller. This pin is internally pulled up to VDD. MT9044 Advance Information Functional Description FS2 FS1 Input Frequency The MT9044 is a Multitrunk System Synchronizer, providing timing (clock) and synchronization (frame) signals to interface circuits for T1 and E1 Primary Rate Digital Transmission links. 0 0 Reserved 0 1 8kHz 1 0 1.544MHz Figure 1 shows the functional block diagram which is described in the following sections. 1 1 2.048MHz Table 1 - Input Frequency Selection Reference Select MUX Circuit Time Interval Error (TIE) Corrector Circuit The MT9044 accepts two simultaneous reference input signals and operates on their falling edges. Either the primary reference (PRI) signal or the secondary reference (SEC) signal can be selected as input to the TIE Corrector Circuit. The selection is based on the Control, Mode and Reference Selection of the device. See Tables 1, 4 and 5. The TIE corrector circuit, when enabled, prevents a step change in phase on the input reference signals (PRI or SEC) from causing a step change in phase at the input of the DPLL block of Figure 1. Frequency Select MUX Circuit The MT9044 operates with one of three possible input reference frequencies (8kHz, 1.544MHz or 2.048MHz). The frequency select inputs (FS1 and FS2) determine which of the three frequencies may be used at the reference inputs (PRI and SEC). Both inputs must have the same frequency applied to them. A reset (RST) must be performed after every frequency select input change. Operation with FS1 and FS2 both at logic low is reserved and must not be used. See Table 1. During reference input rearrangement, such as during a switch from the primary reference (PRI) to the secondary reference (SEC), a step change in phase on the output signals will occur. A phase step at the input of the DPLL will lead to unacceptable phase changes in the output signal. As shown in Figure 3, the TIE Corrector Circuit receives one of the two reference (PRI or SEC) signals, passes the signal through a programmable delay line, and uses this delayed signal as an internal virtual reference, which is input to the DPLL. Therefore, the virtual reference is a delayed version of the selected reference. During a switch, from one reference to the other, the State Machine first changes the mode of the device TCLR Resets Delay Control Circuit Control Signal Delay Value PRI or SEC from Reference Select Mux Programmable Delay Circuit Virtual Reference to DPLL Compare Circuit TIE Corrector Enable from State Machine Feedback Signal from Frequency Select MUX Figure 3 - TIE Corrector Circuit 5 MT9044 Advance Information from Normal to Holdover. In Holdover Mode, the DPLL no longer uses the virtual reference signal, but generates an accurate clock signal using storage techniques. The Compare Circuit then measures the phase delay between the current phase (feedback signal) and the phase of the new reference signal. This delay value is passed to the Programmable Delay Circuit (See Figure 3). The new virtual reference signal is now at the same phase position as the previous reference signal would have been if the reference switch had not taken place. The State Machine then returns the device to Normal Mode. The DPLL now uses the new virtual reference signal, and since no phase step took place at the input of the DPLL, no phase step occurs at the output of the DPLL. In other words, reference switching will not create a phase change at the input of the DPLL, or at the output of the DPLL. Since internal delay circuitry maintains the alignment between the old virtual reference and the new virtual reference, a phase error may exist between the selected input reference signal and the output signal of the DPLL. This phase error is a function of the difference in phase between the two input reference signals during reference rearrangements. Each time a reference switch is made, the delay between input signal and output signal will change. The value of this delay is the accumulation of the error measured during each reference switch. The programmable delay circuit can be zeroed by applying a logic low pulse to the TIE Circuit Reset (TCLR) pin. A minimum reset pulse width is 300ns. This results in a phase alignment between the input reference signal and the output signal as shown in Figure 20. The speed of the phase alignment correction is limited to 5ns per 125us, and convergence is in the direction of least phase travel. The state diagrams of Figure 7 and 8 indicate the state changes that activate the TIE Corrector Circuit. Virtual Reference from TIE Corrector Phase Detector Feedback Signal from Frequency Select MUX Limiter Digital Phase Lock Loop (DPLL) As shown in Figure 4, the DPLL of the MT9044 consists of a Phase Detector, Limiter, Loop Filter, Digitally Controlled Oscillator, and a Control Circuit. Phase Detector - the Phase Detector compares the virtual reference signal from the TIE Corrector circuit with the feedback signal from the Frequency Select MUX circuit, and provides an error signal corresponding to the phase difference between the two. This error signal is passed to the Limiter circuit. The Frequency Select MUX allows the proper feedback signal to be externally selected (e.g., 8kHz, 1.544MHz or 2.048MHz). Limiter - the Limiter receives the error signal from the Phase Detector and ensures that the DPLL responds to all input transient conditions with a maximum output phase slope of 5ns per 125us. This is well within the maximum phase slope of 7.6ns per 125us or 81ns per 1.326ms specified by AT&T TR62411, and Bellcore GR-1244-CORE. Loop Filter - the Loop Filter is similar to a first order low pass filter with a 1.9 Hz cutoff frequency for all three reference frequency selections (8kHz, 1.544MHz or 2.048MHz). This filter ensures that the jitter transfer requirements in ETS 300 011 and AT&T TR62411 are met. Control Circuit - the Control Circuit uses status and control information from the State Machine and the Input Impairment Circuit to set the mode of the DPLL. The three possible modes are Normal, Holdover and Freerun. Digitally Controlled Oscillator (DCO) - the DCO receives the limited and filtered signal from the Loop FIlter, and based on its value, generates a corresponding digital output signal. The synchronization method of the DCO is dependent on the state of the MT9044. Loop Filter State Select from Input Impairment Monitor Digitally Controlled Oscillator Control Circuit State Select from State Machine Figure 4 - DPLL Block Diagram 6 DPLL Reference to Output Interface Circuit MT9044 Advance Information In Normal Mode, the DCO provides an output signal which is frequency and phase locked to the selected input reference signal. T1 Divider C1.5o C3o 12MHz In Holdover Mode, the DCO is free running at a frequency equal to the last (less 30ms to 60ms) frequency the DCO was generating while in Normal Mode. In Freerun Mode, the DCO is free running with an accuracy equal to the accuracy of the OSCi 20MHz source. Tapped Delay Line E1 Divider Tapped Delay Line From DPLL 16MHz Output Interface Circuit Tapped Delay Line The output of the DCO (DPLL) is used by the Output Interface Circuit to provide the output signals shown in Figure 5. The Output Interface Circuit uses four Tapped Delay Lines followed by a T1 Divider Circuit , an E1 Divider Circuit, a DS2 Divider Circuit and an analog PLL to generate the required output signals. Four tapped delay lines are used to generate a 16.384MHz, 12.352MHz, 12.624MHz and 19.44 MHz signals. The E1 Divider Circuit uses the 16.384MHz signal to generate four clock outputs and three frame pulse outputs. The C8o, C4o and C2o clocks are generated by simply dividing the C16o clock by two, four and eight respectively. These outputs have a nominal 50% duty cycle. The T1 Divider Circuit uses the 12.384MHz signal to generate two clock outputs. C1.5o and C3o are generated by dividing the internal C12 clock by four and eight respectively. These outputs have a nominal 50% duty cycle. The DS2 Divider Circuit uses the 12.624 MHz signal to generate the clock output C6o. This output has a nominal 50% duty cycle. Tapped Delay Line 12MHz DS2 Divider 19MHz C2o C4o C8o C16o F0o F8o F16o C6o C19o Analog PLL ACKo ACKi Figure 5 - Output Interface Circuit Block Diagram The frame pulse outputs (F0o, F8o, F16o, TSP, RSP) are generated directly from the C16 clock. The T1 and E1 signals are generated from a common DPLL signal. Consequently, the clock outputs C1.5o, C3o, C2o, C4o, C8o, C16o, F0o, F16o and C6o are locked to one another for all operating states, and are also locked to the selected input reference in Normal Mode. See Figures 20 and 21. All frame pulse and clock outputs have limited driving capability, and should be buffered when driving high capacitance (e.g. 30pF) loads. Analog Phase Lock Loop (APLL) The analog PLL is intended to be used to achieve a 50% duty cycle output clock. Connecting C19o to ACKi will generate a phase locked 19.44 MHz ACKo output with a nominal 50% duty cycle. The analog PLL has an intrinsic jitter of less than 0.01 U.I. In order to achieve this low jitter level a separate pin is provided to power (AVdd) the analog PLL. 7 MT9044 Advance Information Input Impairment Monitor Guard Time Circuit This circuit monitors the input signal to the DPLL and automatically enables the Holdover Mode (Auto-Holdover) when the frequency of the incoming signal is outside the auto-holdover capture range (See AC Electrical Characteristics - Performance). This includes a complete loss of incoming signal, or a large frequency shift in the incoming signal. When the incoming signal returns to normal, the DPLL is returned to Normal Mode with the output signal locked to the input signal. The holdover output signal is based on the incoming signal 30ms minimum to 60ms prior to entering the Holdover Mode. The amount of phase drift while in holdover is negligible because the Holdover Mode is very accurate (e.g. ±0.05ppm). The the Auto-Holdover circuit does not use TIE correction. Consequently, the phase delay between the input and output after switching back to Normal Mode is preserved (is the same as just prior to the switch to Auto-Holdover). The GTi pin is used by the Automatic/Manual Control State Machine in the MT9044 under either Manual or Automatic control. The logic level at the GTi pin performs two functions, it enables and disables the TIE Corrector Circuit (Manual and Automatic), and it selects which mode change takes place (Automatic only). See the Applications - Guard Time section. Automatic/Manual Control State Machine For both Manual and Automatic control, when switching from Primary Holdover to Primary Normal, the TIE Corrector Circuit is enabled when GTi=1, and disabled when GTi=0. Under Automatic control and in Primary Normal Mode, two state changes are possible (not counting Auto-Holdover). These are state changes to Primary Holdover or to Secondary Normal. The logic level at the GTi pin determines which state change occurs. When GTi=0, the state change is to Primary Holdover. When GTi=1, the state change is to Secondary Normal. The Automatic/Manual Control State Machine allows the MT9044 to be controlled automatically (i.e. LOS1, LOS2 and GTi signals) or controlled manually (i.e. MS1, MS2, GTi and RSEL signals). With manual control a single mode of operation (i.e. Normal, Holdover and Freerun) is selected. Under automatic control the state of the LOS1, LOS2 and GTi signals determines the sequence of modes that the MT9044 will follow. Master Clock As shown in Figure 1, this state machine controls the Reference Select MUX, the TIE Corrector Circuit, the DPLL and the Guard Time Circuit. Control is based on the logic levels at the control inputs LOS1, LOS2, RSEL, MS1, MS2 and GTi of the Guard Time Circuit (See Figure 6). The MT9044 can operate either in Manual or Automatic Control. Each control method has three possible modes of operation, Normal, Holdover and Freerun. All state machine changes occur synchronously on the rising edge of F8o. See the Controls and Modes of Operation section for full details on Automatic Control and Manual Control. To Reference Select MUX RSEL LOS1 LOS2 To TIE Corrector Enable To DPLL State Select Automatic/Manual Control State Machine MS1 Control and Modes of Operation As shown in Table 3, Mode/Control Select pins MS2 and MS1 select the mode and method of control. Control RSEL Input Reference MANUAL 0 PRI 1 SEC 0 State Machine Control 1 Reserved AUTO To and From Guard Time Circuit MS2 Figure 6 - Automatic/Manual Control State Machine Block Diagram 8 The MT9044 can use either a clock or crystal as the master timing source. For recommended master timing circuits, see the Applications - Master Clock section. Table 2 - Input Reference Selection MT9044 Advance Information Normal Mode MS2 MS1 Control Mode 0 0 MANUAL NORMAL 0 1 MANUAL HOLDOVER 1 0 MANUAL FREERUN 1 1 AUTO State Machine Control Table 3 - Operating Modes and States Manual Control Manual Control should be used when either very simple MT9044 control is required, or when complex control is required which is not accommodated by Automatic Control. For example, very simple control could include operation in a system which only requires Normal Mode with reference switching using only a single input stimulus (RSEL). Very simple control would require no external circuitry. Complex control could include a system which requires state changes between Normal, Holdover and Freerun Modes based on numerous input stimuli. Complex control would require external circuitry, typically a microcontroller. Under Manual Control, one of the three modes is selected by mode/control select pins MS2 and MS1. The active reference input (PRI or SEC) is selected by the RSEL pin as shown in Table 2. Refer to Table 4 and Figure 7 for details of the state change sequences. Automatic Control Automatic Control should be used when simple MT9044 control is required, which is more complex than the very simple control provide by Manual Control with no external circuitry, but not as complex as Manual Control with a microcontroller. For example, simple control could include operation in a system which can be accommodated by the Automatic Control State Diagram shown in Figure 8. Automatic Control is also selected by mode/control pins MS2 and MS1. However, the mode and active reference source is selected automatically by the internal Automatic State Machine (See Figure 6). The mode and reference changes are based on the logic levels on the LOS1, LOS2 and GTi control pins. Refer to Table 5 and Figure 8 for details of the state change sequences. Normal Mode is typically used when a slave clock source, synchronized to the network is required. In Normal Mode, the MT9044 provides timing (C1.5o, C2o, C3o, C4o, C8o, C16o, and C19) and frame synchronization (F0o, F8o, F16o, RSP, TSP) signals, which are synchronized to one of two reference inputs (PRI or SEC). The input reference signal may have a nominal frequency of 8kHz, 1.544MHz or 2.048MHz. From a reset condition, the MT9044 will take up to 25 seconds for the output signal to be phase locked to the selected reference. The selection of input references is control dependent as shown in State Tables 4 and 5. The reference frequencies are selected by the frequency control pins FS2 and FS1 as shown in Table 1. Holdover Mode Holdover Mode is typically used for short durations (e.g. 2 seconds) while network synchronization is temporarily disrupted. In Holdover Mode, the MT9044 provides timing and synchronization signals, which are not locked to an external reference signal, but are based on storage techniques. The storage value is determined while the device is in Normal Mode and locked to an external reference signal. When in Normal Mode, and locked to the input reference signal, a numerical value corresponding to the MT9044 output frequency is stored alternately in two memory locations every 30ms. When the device is switched into Holdover Mode, the value in memory from between 30ms and 60ms is used to set the output frequency of the device. The frequency accuracy of Holdover Mode is ±0.05ppm, which translates to a worst case 35 frame (125us) slips in 24 hours. This meets the Bellcore GR-1244-CORE Stratum 3 requirement of ±0.37ppm (255 frame slips per 24 hours). Two factors affect the accuracy of Holdover Mode. One is drift on the Master Clock while in Holdover Mode, drift on the Master Clock directly affects the Holdover Mode accuracy. Note that the absolute Master Clock (OSCi) accuracy does not affect Holdover accuracy, only the change in OSCi accuracy while in Holdover. For example, a ±32ppm 9 MT9044 Advance Information master clock may have a temperature coefficient of ±0.1ppm per degree C. So a 10 degree change in temperature, while the MT9044 is in Holdover Mode may result in an additional offset (over the ±0.05ppm) in frequency accuracy of ±1ppm, which is much greater than the ±0.05ppm of the MT9044. The other factor affecting accuracy is large jitter on the reference input prior (30ms to 60ms) to the mode switch. For instance, jitter of 7.5UI at 700Hz may reduce the Holdover Mode accuracy from 0.05ppm to 0.10ppm. Freerun Mode Freerun Mode is typically used when a master clock source is required, or immediately following system power-up before network synchronization is achieved. In Freerun Mode, the MT9044 provides timing synchronization signals which are based on master clock frequency (OSCi) only, and are synchronized to the reference signals (PRI SEC). and the not and The accuracy of the output clock is equal to the accuracy of the master clock (OSCi). So if a ±32ppm output clock is required, the master clock must also be ±32ppm. See Applications - Crystal and Clock Oscillator sections. 10 MT9044 Advance Information Description State Input Controls Freerun Normal (PRI) Normal (SEC) Holdover (PRI) Holdover (SEC) MS2 MS1 RSEL GTi S0 S1 S2 S1H S2H 0 0 0 0 S1 - S1 MTIE S1 S1 MTIE 0 0 0 1 S1 - S1 MTIE S1 MTIE S1 MTIE 0 0 1 X S2 S2 MTIE - S2 MTIE S2 MTIE 0 1 0 X / S1H / - / 0 1 1 X / S2H S2H / - 1 0 X X - S0 S0 S0 S0 Legend: No Change / Not Valid MTIE State change occurs with TIE Corrector Circuit Refer to Manual Control State Diagram for state changes to and from Auto-Holdover State Table 4 - Manual Control State Table S0 Freerun (10X) S1 Normal Primary (000) {A} (GTi=0) (GTi=1) NOTES: (XXX) MS2 MS1 RSEL {A} Invalid Reference Signal S1A Auto-Holdover Primary (000) S2A Auto-Holdover Secondary (001) S1H Holdover Primary (010) S2H Holdover Secondary (011) {A} S2 Normal Secondary (001) Phase Re-Alignment Phase Continuity Maintained (without TIE Corrector Circuit) Phase Continuity Maintained (with TIE Corrector Circuit) Movement to Normal State from any state requires a valid input signal Figure 7 - Manual Control State Diagram 11 MT9044 Advance Information Description State Input Controls Freerun Normal (PRI) Normal (SEC) Holdover (PRI) Holdover (SEC) LOS2 LOS1 GTi RST S0 S1 S2 S1H S2H 1 1 X 0 to 1 - S0 S0 S0 S0 X 0 0 1 S1 - S1 MTIE S1 S1 MTIE X 0 1 1 S1 - S1 MTIE S1 MTIE S1 MTIE 0 1 0 1 S1 S1H - - S2 MTIE 0 1 1 1 S2 S2 MTIE - S2 MTIE S2 MTIE 1 1 X 1 - S1H S2H - - Legend: No Change MTIE State change occurs with TIE Corrector Circuit Refer to Automatic Control State Diagram for state changes to and from Auto-Holdover State Table 5 - Automatic Control (MS1=MS2=1, RSEL=0) State Table (11X) (11X) RST=1 Reset S0 Freerun (X0X) (01X) (X0X) (X0X) (01X) (01X) (X0X) S1 Normal Primary {A} (01X) S1A Auto-Holdover Primary S2A Auto-Holdover Secondary S2 Normal Secondary {A} (X0X) (011) (11X) (010 or 11X) (X0X) (011) (01X) (X00) S1H Holdover Primary (X01) (010 or 11X) NOTES: (XXX) LOS2 LOS1 GTi {A} Invalid Reference Signal S2H Holdover Secondary (11X) Phase Re-Alignment Phase Continuity Maintained (without TIE Corrector Circuit) Phase Continuity Maintained (with TIE Corrector Circuit) Movement to Normal State from any state requires a valid input signal Figure 8 - Automatic Control State Diagram 12 MT9044 Advance Information MT9044 Measures of Performance same signal, these transfer values apply to all outputs. The following are some synchronizer performance indicators and their corresponding definitions. It should be noted that 1UI at 1.544MHz is 644ns, which is not equal to 1UI at 2.048MHz, which is 488ns. Consequently, a transfer value using different input and output frequencies must be calculated in common units (e.g. seconds) as shown in the following example. Intrinsic Jitter Intrinsic jitter is the jitter produced by the synchronizing circuit and is measured at its output. It is measured by applying a reference signal with no jitter to the input of the device, and measuring its output jitter. Intrinsic jitter may also be measured when the device is in a non-synchronizing mode, such as free running or holdover, by measuring the output jitter of the device. Intrinsic jitter is usually measured with various bandlimiting filters depending on the applicable standards. Jitter Tolerance Jitter tolerance is a measure of the ability of a PLL to operate properly (i.e., remain in lock and or regain lock in the presence of large jitter magnitudes at various jitter frequencies) when jitter is applied to its reference. The applied jitter magnitude and jitter frequency depends on the applicable standards. Jitter Transfer Jitter transfer or jitter attenuation refers to the magnitude of jitter at the output of a device for a given amount of jitter at the input of the device. Input jitter is applied at various amplitudes and frequencies, and output jitter is measured with various filters depending on the applicable standards. For the MT9044, two internal elements determine the jitter attenuation. This includes the internal 1.9Hz low pass loop filter and the phase slope limiter. The phase slope limiter limits the output phase slope to 5ns/125us. Therefore, if the input signal exceeds this rate, such as for very large amplitude low frequency input jitter, the maximum output phase slope will be limited (i.e. attenuated) to 5ns/125us. The MT9044 has thirteen outputs with three possible input frequencies for a total of 39 possible jitter transfer functions. However, the data sheet section on AC Electrical Characteristics - Jitter Transfer specifies transfer values for only three cases, 8kHz to 8kHz, 1.544MHz to 1.544MHz and 2.048MHz to 2.048MHz. Since all outputs are derived from the What is the T1 and E1 output jitter when the T1 input jitter is 20UI (T1 UI Units) and the T1 to T1 jitter attenuation is 18dB? A –----- 20 OutputT 1 = InputT 1 ×10 18 –------- 20 OutputT 1 = 20 ×10 = 2.5UI ( T 1 ) ( 1UIT 1 ) OutputE1 = OutputT 1 × ---------------------( 1UIE1 ) ( 644ns ) OutputE1 = OutputT 1 × ------------------- = 3.3UI ( T 1 ) ( 488ns ) Using the above method, the jitter attenuation can be calculated for all combinations of inputs and outputs based on the three jitter transfer functions provided. Note that the resulting jitter transfer functions for all combinations of inputs (8kHz, 1.544MHz, 2.048MHz) and outputs (8kHz, 1.544MHz, 2.048MHz, 4.096MHz, 8.192MHz, 16.384MHz) for a given input signal (jitter frequency and jitter amplitude) are the same. Since intrinsic jitter is always present, jitter attenuation will appear to be lower for small input jitter signals than for large ones. Consequently, accurate jitter transfer function measurements are usually made with large input jitter signals (e.g. 75% of the specified maximum jitter tolerance). Frequency Accuracy Frequency accuracy is defined as the absolute tolerance of an output clock signal when it is not locked to an external reference, but is operating in a free running mode. For the MT9044, the Freerun accuracy is equal to the Master Clock (OSCi) accuracy. Holdover Accuracy Holdover accuracy is defined as the absolute tolerance of an output clock signal, when it is not 13 MT9044 locked to an external reference signal, but is operating using storage techniques. For the MT9044, the storage value is determined while the device is in Normal Mode and locked to an external reference signal. The absolute Master Clock (OSCi) accuracy of the MT9044 does not affect Holdover accuracy, but the change in OSCi accuracy while in Holdover Mode does. Capture Range Also referred to as pull-in range. This is the input frequency range over which the synchronizer must be able to pull into synchronization. The MT9044 capture range is equal to ±230ppm minus the accuracy of the master clock (OSCi). For example, a ±32ppm master clock results in a capture range of ±198ppm. Lock Range This is the input frequency range over which the synchronizer must be able to maintain synchronization. The lock range is equal to the capture range for the MT9044. Phase Slope Phase slope is measured in seconds per second and is the rate at which a given signal changes phase with respect to an ideal signal. The given signal is typically the output signal. The ideal signal is of constant frequency and is nominally equal to the value of the final output signal or final input signal. Time Interval Error (TIE) TIE is the time delay between a given timing signal and an ideal timing signal. Maximum Time Interval Error (MTIE) MTIE is the maximum peak to peak delay between a given timing signal and an ideal timing signal within a particular observation period. MTIE ( S ) = TIEmax ( t ) – TIEmin ( t ) Phase Continuity Phase continuity is the phase difference between a given timing signal and an ideal timing signal at the 14 Advance Information end of a particular observation period. Usually, the given timing signal and the ideal timing signal are of the same frequency. Phase continuity applies to the output of the synchronizer after a signal disturbance due to a reference switch or a mode change. The observation period is usually the time from the disturbance, to just after the synchronizer has settled to a steady state. In the case of the MT9044, the output signal phase continuity is maintained to within ±5ns at the instance (over one frame) of all reference switches and all mode changes. The total phase shift, depending on the switch or type of mode change, may accumulate up to ±200ns over many frames. The rate of change of the ±200ns phase shift is limited to a maximum phase slope of approximately 5ns/125us. This meets the maximum phase slope requirement of Bellcore GR-1244-CORE (81ns/ 1.326ms). Phase Lock Time This is the time it takes the synchronizer to phase lock to the input signal. Phase lock occurs when the input signal and output signal are not changing in phase with respect to each other (not including jitter). Lock time is very difficult to determine because it is affected by many factors which include: i) initial input to output phase difference ii) initial input to output frequency difference iii) synchronizer loop filter iv) synchronizer limiter Although a short lock time is desirable, it is not always possible to achieve due to other synchronizer requirements. For instance, better jitter transfer performance is achieved with a lower frequency loop filter which increases lock time. And better (smaller) phase slope performance (limiter) results in longer lock times. The MT9044 loop filter and limiter were optimized to meet the AT&T TR62411 jitter transfer and phase slope requirements. Consequently, phase lock time, which is not a standards requirement, may be longer than in other applications. See AC Electrical Characteristics Performance for maximum phase lock time. MT9044 Advance Information MT9044 and Network Specifications Applications The MT9044 fully meets all applicable PLL requirements (intrinsic jitter/wander, jitter/wander tolerance, jitter/wander transfer, frequency accuracy, frequency holdover accuracy, capture range, phase change slope and MTIE during reference rearrangement) for the following specifications. This section contains MT9044 application specific details for clock and crystal operation, guard time usage, reset operation, power supply decoupling, Manual Control operation and Automatic Control operation. Master Clock 1. Bellcore GR-1244-CORE June 1995 for Stratum 3, Stratum 4 Enhanced and Stratum 4 2. AT&T TR62411 (DS1) December 1990 for Stratum 3, Stratum 4 Enhanced and Stratum 4 3. ANSI T1.101 (DS1) February 1994 for Stratum 3, Stratum 4 Enhanced and Stratum 4 4. ETSI 300 011 (E1) April 1992 for Single Access and Multi Access 5. TBR 4 November 1995 6. TBR 12 December 1993 7. TBR 13 January 1996 8. ITU-T I.431 March 1993 9. ITU-T G.812 June 1998 for type IV clocks for 1,544 kbit/s interfaces and 2,048 kbit/s interfaces The MT9044 can use either a clock or crystal as the master timing source. In Freerun Mode, the frequency tolerance at the clock outputs is identical to the frequency tolerance of the source at the OSCi pin. For applications not requiring an accurate Freerun Mode, tolerance of the master timing source may be ±100ppm. For applications requiring an accurate Freerun Mode, such as Bellcore GR-1244-CORE, the tolerance of the master timing source must Be no greater than ±32ppm. Another consideration in determining the accuracy of the master timing source is the desired capture range. The sum of the accuracy of the master timing source and the capture range of the MT9044 will always equal ±230ppm. For example, if the master timing source is ±100ppm, then the capture range will be ±130ppm. Clock Oscillator - when selecting a Clock Oscillator, numerous parameters must be considered. This includes absolute frequency, frequency change over temperature, output rise and fall times, output levels and duty cycle. See AC Electrical Characteristics. MT9044 OSCi +5V +5V 20MHz OUT GND 0.1uF OSCo No Connection Figure 9 - Clock Oscillator Circuit For applications requiring ±32ppm clock accuracy, the following clock oscillator module may be used. CTS CXO-65-HG-5-C-20.0MHz Frequency: 20MHz Tolerance: 25ppm 0C to 70C 15 MT9044 Rise & Fall Time: Duty Cycle: Advance Information 8ns (0.5V 4.5V 50pF) 45% to 55% e.g., CTS R1027-2BB-20.0MHZ (±20ppm absolute, ±6ppm 0C to 50C, 32pF, 25Ω) The output clock should be connected directly (not AC coupled) to the OSCi input of the MT9044, and the OSCo output should be left open as shown in Figure 9. Crystal Oscillator - Alternatively, a Crystal Oscillator may be used. A complete oscillator circuit made up of a crystal, resistor and capacitors is shown in Figure 10. MT9044 Guard Time Adjustment Excessive switching of the timing reference (from PRI to SEC) in the MT9044 can be minimized by first entering Holdover Mode for a predetermined maximum time (i.e., guard time). If the degraded signal returns to normal before the expiry of the guard time (e.g. 2.5 seconds), then the MT9044 is returned to its Normal Mode (with no reference switch taking place). Otherwise, the reference input may be changed from Primary to Secondary. OSCi MT9044 20MHz GTo 1MΩ R 150kΩ 56pF 39pF + 3-50pF C 10uF OSCo 100Ω 1uH GTi 1uH inductor: may improve stability and is optional RP 1kΩ Figure 10 - Crystal Oscillator Circuit The accuracy of a crystal oscillator depends on the crystal tolerance as well as the load capacitance tolerance. Typically, for a 20MHz crystal specified with a 32pF load capacitance, each 1pF change in load capacitance contributes approximately 9ppm to the frequency deviation. Consequently, capacitor tolerances, and stray capacitances have a major effect on the accuracy of the oscillator frequency. The trimmer capacitor shown in Figure 10 may be used to compensate for capacitive effects. If accuracy is not a concern, then the trimmer may be removed, the 39pF capacitor may be increased to 56pF, and a wider tolerance crystal may be substituted. The crystal should be a fundamental mode type - not an overtone. The fundamental mode crystal permits a simpler oscillator circuit with no additional filter components and is less likely to generate spurious responses. The crystal specification is as follows. Frequency: Tolerance: Oscillation Mode: Resonance Mode: Load Capacitance: Maximum Series Resistance: Approximate Drive Level: 16 20MHz As required Fundamental Parallel 32pF 35Ω 1mW Figure 11 - Symmetrical Guard Time Circuit A simple way to control the guard time (using Automatic Control) is with an RC circuit as shown in Figure 11. Resistor RP is for protection only and limits the current flowing into the GTi pin during power down conditions. The guard time can be calculated as follows. V DD guard time = RC × ln ---------------------------------- V – V DD SIH guard time ≈ RC × 0.6 example guard time ≈ 150k × 10u × 0.6 = 0.9s • VSIH is the logic high going threshold level for the GTi Schmitt Trigger input, see DC Electrical Characteristics In cases where fast toggling might be expected of the LOS1 input, then an unsymmetrical Guard Time Circuit is recommended. This ensures that reference switching doesn’t occur until the full guard time value has expired. An unsymmetrical Guard Time Circuit is shown in Figure 12. MT9044 Advance Information For instance, 10 Normal to Holdover to Normal mode change sequences occur, and in each case Holdover was entered for 2s. Each mode change sequence could account for a phase change as large as 350ns. Thus, the accumulated phase change could be as large as 3.5us, and, the overall MTIE could be as large as 3.5us. MT9044 GTo + RC 150kΩ RD 1kΩ Phase hold = 0.05 ppm × 2s = 100ns C 10uF GTi Phase state = 50ns + 200ns = 250ns Phase 10 = 10 × ( 250ns + 100ns ) = 3.5us RP 1kΩ Figure 12 - Unsymmetrical Guard Time Circuit Figure 13 shows a typical timing example of an unsymmetrical Guard Time Circuit with the MT9044 in Automatic Control. • 0.05ppm is the accuracy of Holdover Mode • 50ns is the maximum phase continuity of the MT9044 from Normal Mode to Holdover Mode • 200ns is the maximum phase continuity of the MT9044 from Holdover Mode to Normal Mode (with or without TIE Corrector Circuit) TIE Correction (using GTi) When 10 Normal to Holdover to Normal mode change sequences occur without MTIE enabled, and in each case holdover was entered for 2s, each mode change sequence could still account for a phase change as large as 350ns. However, there would be no accumulated phase change, since the input to output phase is re-aligned after every Holdover to Normal state change. The overall MTIE would only be 350ns. When Primary Holdover Mode is entered for short time periods, TIE correction should not be enabled. This will prevent unwanted accumulated phase change between the input and output. This is mainly applicable to Manual Control, since Automatic Control together with the Guard Time Circuit inherently operate in this manner. SEC SIGNAL STATUS GOOD LOS2 PRI SIGNAL STATUS GOOD BAD GOOD TD GOOD BAD TD LOS1 GTo VSIH GTi MT9044 STATE PRI NORMAL PRI HOLDOVER PRI NORMAL PRI HOLDOVER SEC NORMAL PRI NORMAL NOTES: 1. TD represents the time delay from when the reference goes bad to when the MT9044 is provided with a LOS indication. Figure 13 - Automatic Control, Unsymmetrical Guard Time Circuit Timing Example 17 MT9044 Advance Information Reset Circuit Dual T1 Reference Sources with MT9044 in Automatic Control A simple power up reset circuit with about a 50us reset low time is shown in Figure 14. Resistor RP is for protection only and limits current into the RST pin during power down conditions. The reset low time is not critical but should be greater than 300ns. MT9044 +5V R 10kΩ RST RP 1kΩ C 10nF Figure 14 - Power-Up Reset Circuit To Line 1 DSTo DSTi TRING RTIP To RX Line XFMR In this circuit, the MT9044 is operating Automatically, using a Guard Time Circuit, and the LOS1 and LOS2 inputs to determine all mode changes. Since the Guard Time Circuit is set to about 1s, all line interruptions (LOS1=1) less than 1s will cause the MT9044 to go from Primary Normal Mode to Holdover Mode and not switch references. For line interruptions greater than 1s, the MT9044 will switch Modes from Holdover to Secondary Normal, provided that the secondary signal is valid (LOS2=0). After receiving a good primary signal (LOS1=0), the MT9044 will switch back to Primary Normal Mode For complete Automatic Control state machine details, refer to Table 5 for the State Table, and Figure 8 for the State Diagram. MT9074 TTIP To TX Line XFMR For systems requiring simple state machine control, the application circuit shown in Figure 15 using Automatic Control may be used. F0i C4i RRING MT9044 E1.5o LOS PRI SEC + 5V To Line 2 TTIP To TX Line XFMR RTIP To RX Line XFMR DSTo DSTi TRING + 5V FS1 FS2 150kΩ GTo GTi 1kΩ RST OSCi 1kΩ 10kΩ + 5V TRST 1kΩ F0i C4i LOS1 LOS2 MS1 MS2 RSEL MT9074 F0o C4o + 10uF RRING E1.5o LOS 10nF CLOCK Out 20MHz ±32ppm MT8985 STo0 STi0 STo1 STi1 F0i C4i Figure 15 - Dual T1 Reference Sources with MT9044 in 1.544MHz Automatic Control 18 MT9044 Advance Information To Line 1 To TX Line XFMR MT9075 TTIP TRING RTIP To RX Line XFMR DSTo DSTi F0i C4i RRING MT9044 RxFP PRI LOS To Line 2 DSTo DSTi TRING RST RTIP To RX Line XFMR F0o C4o LOS1 C1.5o LOS2 FS1 MS1 FS2 MS2 RSEL GTi TRST MT9075 TTIP To TX Line XFMR SEC F0i C4i OSCi + 5V CLOCK Out 20MHz ±32ppm RRING RxFP LOS External Stimulus CONTROLLER MT8985 STo0 STi0 STo1 STi1 F0i C4i Figure 16 - Dual E1 Reference Sources with MT9044 in 8kHz Manual Control Dual E1 Reference Sources with MT9044 in Manual Control circuit reset pin (TCLR), and a complete device reset is done with the RST pin. For systems requiring complex state machine control, the application circuit shown in Figure 16 using Manual Control may be used. The controller uses two stimulus inputs (LOS) directly from the MT9075 E1 interfaces, as well as an external stimulus input. The external input may come from a device that monitors the status registers of the E1 interfaces, and outputs a logic one in the event of an unacceptable status condition. In this circuit, the MT9044 is operating Manually and is using a controller for all mode changes. The controller sets the MT9044 modes (Normal, Holdover or Freerun) by controlling the MT9044 mode/control select pins (MS2 and MS1). The input (Primary or Secondary) is selected with the reference select pin (RSEL). TIE correction from Primary Holdover Mode to Primary Normal Mode is enabled and disabled with the guard time input pin (GTi). The input to output phase alignment is re-aligned with the TIE For complete Manual Control state machine details, refer to Table 4 for the State Table, and Figure 7 for the State Diagram. 19 MT9044 To E1 Line Advance Information MT9075 DSTo DSTi TTIP To TX Line XFMR TRING F0i C4i RTIP To RX Line XFMR RRING MT9044 RxFP PRI LOS To OC3 Line To TX Line XFMR To RX Line XFMR LOS1 C1.5o LOS2 FS1 MS1 FS2 MS2 RSEL OSCi TCLR C19o ACKi RST ACKo MT90840 PDo0-7 STo0-7 STi0-7 PPFTo PDi0-7 PCKR F0i C4b PCKT F0o C4o 1kΩ + 5V GTi 10kΩ + 5V PPFRi 10nF MT90820 STo0 STi0 STo1-8 STi1-8 F0i C4i Figure 17 - Single Source - E1 to STS-3 with 8kHz Reference Single Reference Source E1 to STS-3 with 8 kHz Reference The device may operate in freerun mode or with a single reference source. The 8 kHz output from the MT9075 is sourced from the clock extracted from the E1 trunk. It becomes the reference for the PLL which then generates ST-BUS signals F0o, C4o and C2o to form the system backplane clock. The MT90840 connects to the system backplane, as well as to an OC3 link via an STS-3 Framer and optical link. The 19.44 Mhz clock required by the MT90840 is generated by the MT9044. In the event that the E1 link is broken, the LOS output of the MT9075 goes high placing the MT9044 in freerun mode. 20 CLOCK Out 20MHz ±32ppm MT9044 Advance Information Absolute Maximum Ratings* - Voltages are with respect to ground (V SS) unless otherwise stated. Parameter Symbol Min Max Units 1 Supply voltage VDD -0.3 7.0 V 2 Voltage on any pin VPIN -0.3 VDD+0.3 V 3 Current on any pin IPIN 20 mA 4 Storage temperature TST 125 °C 5 PLCC package power dissipation PPD 900 mW 6 MQFP package power dissipation PPD 900 * Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied. mW -55 Recommended Operating Conditions* - * Voltages are with respect to ground (VSS) unless otherwise stated. Characteristics 1 Supply voltage 2 Operating temperature Sym Min Max Units VDD 4.5 5.5 V TA -40 85 C DC Electrical Characteristics* - * Voltages are with respect to ground (VSS) unless otherwise stated. Characteristics 1 Supply current with: 2 Sym Min Max Units Conditions/Notes OSCi = 0V IDDS 10 mA Outputs unloaded OSCi = Clock IDD 90 mA Outputs unloaded 3 TTL high-level input voltage VIH 2.0 4 TTL low-level input voltage VIL 5 CMOS high-level input voltage VCIH 6 CMOS low-level input voltage VCIL 7 Schmitt high-level input voltage VSIH 8 Schmitt low-level input voltage VSIL 9 Schmitt hysteresis voltage VHYS 0.4 10 Input leakage current IIL -10 11 High-level output voltage VOH 0.8VDD 12 Low-level output voltage VOL V 0.8 0.7VDD 0.3VDD 2.3 0.8 +10 0.2VDD V V OSCi V OSCi V GTi, RST V GTi, RST V GTi, RST uA VI=VDD or 0V V IOH=4mA V IOL=4mA * Supply voltage and operating temperature are as per Recommended Operating Conditions. 21 MT9044 Advance Information AC Electrical Characteristics - Performance Characteristics Min Max Units Conditions/Notes† ±±0ppm -0 +0 ppm 5-8 2 ±32ppm -32 +32 ppm 5-8 3 ±100ppm -100 +100 ppm 5-8 ±0ppm -0.05 +0.05 ppm 1,2,4,6-8,40 5 ±32ppm -0.05 +0.05 ppm 1,2,4,6-8,40 6 ±100ppm -0.05 +0.05 ppm 1,2,4,6-8,40 ±0ppm -230 +230 ppm 1-3,6-8 8 ±32ppm -198 +198 ppm 1-3,6-8 9 ±100ppm -130 +130 ppm 1-3,6-8 30 s 1-3,6-14 reference switch 200 ns 1-3,6-14 12 mode switch to Normal 200 ns 1-2,4-14 13 mode switch to Freerun 200 ns 1-,4,6-14 14 mode switch to Holdover 50 ns 1-3,6-14 1 4 7 Sym Freerun Mode accuracy with OSCi at: Holdover Mode accuracy with OSCi at: Capture range with OSCi at: 10 Phase lock time 11 Output phase continuity with: 15 MTIE (maximum time interval error) 600 ns 1-14,27 16 Output phase slope 45 us/s 1-14,27 17 Reference input for Auto-Holdover with: 8kHz -18k +18k ppm 1-3,6,9-11 18 1.544MHz -36k +36k ppm 1-3,7,9-11 19 2.048MHz -36k +36k ppm 1-3,8-11 † See "Notes" following AC Electrical Characteristics tables. AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels* - Voltages are with respect to ground (V SS) unless otherwise stated. Characteristics Sym Schmitt TTL CMOS Units VT 1.5 1.5 0.5VDD V 1 Threshold Voltage 2 Rise and Fall Threshold Voltage High VHM 2.3 2.0 0.7VDD V 3 Rise and Fall Threshold Voltage Low VLM 0.8 0.8 0.3VDD V * Supply voltage and operating temperature are as per Recommended Operating Conditions. * Timing for input and output signals is based on the worst case result of the combination of TTL and CMOS thresholds. * See Figure 18. Timing Reference Points V HM VT VLM ALL SIGNALS tIRF, tORF tIRF, tORF Figure 18 - Timing Parameter Measurement Voltage Levels 22 MT9044 Advance Information AC Electrical Characteristics - Input/Output Timing Characteristics Sym Min 100 1 Reference input pulse width high or low tRW 2 Reference input rise or fall time tIRF 3 8kHz reference input to F8o delay tR8D 4 1.544MHz reference input to F8o delay 5 Max Units ns 10 ns -21 6 ns tR15D 337 363 ns 2.048MHz reference input to F8o delay tR2D 222 238 ns 6 F8o to F0o delay tF0D 110 134 ns 7 F16o setup to C16o falling tF16S 11 35 ns 8 F16o hold from C16o rising tF16H 0 20 ns 9 F8o to C1.5o delay tC15D -51 -37 ns 10 F8o to C6o delay tC6D -3 11 ns 11 F8o to C3o delay tC3D -51 -37 ns 12 F8o to C2o delay tC2D -13 2 ns 13 F8o to C4o delay tC4D -13 2 ns 14 F8o to C8o delay tC8D -13 2 ns 15 F8o to C16o delay tC16D -13 2 ns 16 F8o to TSP delay tTSPD -10 10 ns 17 F8o to RSP delay tRSPD -10 10 ns 18 F8o to C19o delay tC19D 0 52 ns 19 C1.5o pulse width high or low tC15W 309 339 ns 20 C3o pulse width high or low tC3W 149 175 ns 21 C6o pulse width high or low tC6W 72 86 ns 22 C2o pulse width high or low tC2W 230 258 ns 23 C4o pulse width high or low tC4W 111 133 ns 24 C8o pulse width high or low tC8W 52 70 ns 25 C16o pulse width high or low tC16WL 24 35 ns 26 TSP pulse width high tTSPW 478 494 ns 27 RSP pulse width high tRSPW 474 491 ns 28 C19o pulse width high or low tC19W 16 36 ns 29 F0o pulse width low tF0WL 230 258 ns 30 F8o pulse width high tF8WH 111 133 ns 31 F16o pulse width low tF16WL 52 70 ns 32 Output clock and frame pulse rise or fall time 9 ns 33 Input Controls Setup Time tS 100 ns 34 Input Controls Hold Time tH 100 ns tORF † See "Notes" following AC Electrical Characteristics tables. 23 MT9044 Advance Information tR8D PRI/SEC 8kHz tRW tR15D PRI/SEC 1.544MHz VT tRW VT tR2D PRI/SEC 2.048MHz tRW VT VT F8o NOTES: 1. Input to output delay values are valid after a TRST or RST with no further state changes Figure 19 - Input to Output Timing (Normal Mode) tF8WH VT F8o tF0D tF0WL VT F0o tF16WL VT F16o tF16S tC16WL tF16H tC16D VT C16o tC8W tC8W tC8D VT C8o tC4W tC4W tC4D VT C4o tC2D tC2W C2o tC6W tC6W tC6D C6o tC3W tC3W VT VT tC3D VT C3o tC15W tC15D VT C1.5o tC19W tC19W VT C19o Figure 20 - Output Timing 1 24 tC19D MT9044 Advance Information F8o VT VT C2o tRSPD VT RSP tRSPW tTSPW TSP VT tTSPD Figure - 21 Output Timing 2 VT F8o tS tH MS1,2 LOS1,2 RSEL, GTi VT Figure 22 - Input Controls Setup and Hold Timing AC Electrical Characteristics - Intrinsic Jitter Unfiltered Characteristics Sym Min Max Units Conditions/Notes† 1 Intrinsic jitter at F8o (8kHz) 0.0002 UIpp 1-14,21-24,28 2 Intrinsic jitter at F0o (8kHz) 0.0002 UIpp 1-14,21-24,28 3 Intrinsic jitter at F16o (8kHz) 0.0002 UIpp 1-14,21-24,28 4 Intrinsic jitter at C1.5o (1.544MHz) 0.030 UIpp 1-14,21-24,29 5 Intrinsic jitter at C2o (2.048MHz) 0.040 UIpp 1-14,21-24,30 6 Intrinsic jitter at C3o (3.088MHz) 0.060 UIpp 1-14,21-24,31 7 Intrinsic jitter at C6o (6.312MHz) 0.120 UIpp 1-14,21-24,31 8 Intrinsic jitter at C4o (4.096MHz) 0.080 UIpp 1-14,21-24,32 9 Intrinsic jitter at C8o (8.192MHz) 0.160 UIpp 1-14,21-24,33 10 Intrinsic jitter at C16o (16.384MHz) 0.320 UIpp 1-14,21-24,34 11 Intrinsic jitter at TSP (8kHz) 0.0002 UIpp 1-14,21-24,28 12 Intrinsic jitter at RSP (8kHz) 0.0002 UIpp 1-14,21-24,28 13 Intrinsic jitter at C19o (19.44MHz) 0.10 UIpp 1-14,21-24,41 † See "Notes" following AC Electrical Characteristics tables. 25 MT9044 Advance Information AC Electrical Characteristics - C1.5o (1.544MHz) Intrinsic Jitter Filtered Characteristics Sym Min Max Units Conditions/Notes† 1 Intrinsic jitter (4Hz to 100kHz filter) 0.015 UIpp 1-14,21-24,29 2 Intrinsic jitter (10Hz to 40kHz filter) 0.010 UIpp 1-14,21-24,29 3 Intrinsic jitter (8kHz to 40kHz filter) 0.010 UIpp 1-14,21-24,29 4 Intrinsic jitter (10Hz to 8kHz filter) 0.005 UIpp 1-14,21-24,29 † See "Notes" following AC Electrical Characteristics tables. AC Electrical Characteristics - C2o (2.048MHz) Intrinsic Jitter Filtered Characteristics Sym Min Max Units Conditions/Notes† 1 Intrinsic jitter (4Hz to 100kHz filter) 0.015 UIpp 1-14,21-24,30 2 Intrinsic jitter (10Hz to 40kHz filter) 0.010 UIpp 1-14,21-24,30 3 Intrinsic jitter (8kHz to 40kHz filter) 0.010 UIpp 1-14,21-24,30 4 Intrinsic jitter (10Hz to 8kHz filter) 0.005 UIpp 1-14,21-24,30 † See "Notes" following AC Electrical Characteristics tables AC Electrical Characteristics - 8kHz Input to 8kHz Output Jitter Transfer Characteristics Sym Min Max Units Conditions/Notes† 1 Jitter attenuation for [email protected] input 0 6 dB 1-3,6,9-14,21-22,24,28,35 2 Jitter attenuation for [email protected] input 6 16 dB 1-3,6,9-14,21-22,24,28,35 3 Jitter attenuation for [email protected] input 12 22 dB 1-3,6,9-14,21-22,24,28,35 4 Jitter attenuation for [email protected] input 28 38 dB 1-3,6,9-14,21-22,24,28,35 5 Jitter attenuation for [email protected] input 42 dB 1-3,6,9-14,21-22,24,28,35 6 Jitter attenuation for [email protected] input 45 dB 1-3,6,9-14,21-22,24,28,35 † See "Notes" following AC Electrical Characteristics tables. AC Electrical Characteristics - 1.544MHz Input to 1.544MHz Output Jitter Transfer Characteristics Sym Min Max Units Conditions/Notes† 1 Jitter attenuation for 1Hz@20UIpp input 0 6 dB 1-3,7,9-14,21-22,24,29,35 2 Jitter attenuation for 1Hz@104UIpp input 6 16 dB 1-3,7,9-14,21-22,24,29,35 3 Jitter attenuation for 10Hz@20UIpp input 12 22 dB 1-3,7,9-14,21-22,24,29,35 4 Jitter attenuation for 60Hz@20UIpp input 28 38 dB 1-3,7,9-14,21-22,24,29,35 5 Jitter attenuation for 300Hz@20UIpp input 42 dB 1-3,7,9-14,21-22,24,29,35 6 Jitter attenuation for [email protected] input 45 dB 1-3,7,9-14,21-22,24,29,35 7 Jitter attenuation for [email protected] input 45 dB 1-3,7,9-14,21-22,24,29,35 † See "Notes" following AC Electrical Characteristics tables. 26 MT9044 Advance Information AC Electrical Characteristics - 2.048MHz Input to 2.048 MHz Output Jitter Transfer Characteristics Sym Min Max Units Conditions/Notes† 1 Jitter at output for [email protected] input 2.9 UIpp 1-3,8,9-14,21-22,24,30,35 2 with 40Hz to 100kHz filter 0.09 UIpp 1-3,8,9-14,21-22,24,30,36 3 Jitter at output for [email protected] input 1.3 UIpp 1-3,8,9-14,21-22,24,30,35 4 with 40Hz to 100kHz filter 0.10 UIpp 1-3,8,9-14,21-22,24,30,36 5 Jitter at output for [email protected] input 0.80 UIpp 1-3,8,9-14,21-22,24,30,35 6 with 40Hz to 100kHz filter 0.10 UIpp 1-3,8,9-14,21-22,24,30,36 7 Jitter at output for [email protected] input 0.40 UIpp 1-3,8,9-14,21-22,24,30,35 8 with 40Hz to 100kHz filter 0.10 UIpp 1-3,8,9-14,21-22,24,30,36 9 Jitter at output for [email protected] input 0.06 UIpp 1-3,8,9-14,21-22,24,30,35 10 with 40Hz to 100kHz filter 0.05 UIpp 1-3,8,9-14,21-22,24,30,36 11 Jitter at output for [email protected] input 0.04 UIpp 1-3,8,9-14,21-22,24,30,35 12 with 40Hz to 100kHz filter 0.03 UIpp 1-3,8,9-14,21-22,24,30,36 13 Jitter at output for [email protected] input 0.04 UIpp 1-3,8,9-14,21-22,24,30,35 14 with 40Hz to 100kHz filter 0.02 UIpp 1-3,8,9-14,21-22,24,30,36 † See "Notes" following AC Electrical Characteristics tables. AC Electrical Characteristics - 8kHz Input Jitter Tolerance Characteristics Sym Min Max Units Conditions/Notes† 1 Jitter tolerance for 1Hz input 0.80 UIpp 1-3,6,9-14,21-22,24-26,28 2 Jitter tolerance for 5Hz input 0.70 UIpp 1-3,6,9-14,21-22,24-26,28 3 Jitter tolerance for 20Hz input 0.60 UIpp 1-3,6,9-14,21-22,24-26,28 4 Jitter tolerance for 300Hz input 0.20 UIpp 1-3,6,9-14,21-22,24-26,28 5 Jitter tolerance for 400Hz input 0.15 UIpp 1-3,6,9-14,21-22,24-26,28 6 Jitter tolerance for 700Hz input 0.08 UIpp 1-3,6,9-14,21-22,24-26,28 7 Jitter tolerance for 2400Hz input 0.02 UIpp 1-3,6,9-14,21-22,24-26,28 8 Jitter tolerance for 3600Hz input 0.01 UIpp 1-3,6,9-14,21-22,24-26,28 † See "Notes" following AC Electrical Characteristics tables. 27 MT9044 Advance Information AC Electrical Characteristics - 1.544MHz Input Jitter Tolerance Characteristics Sym Min Max Units Conditions/Notes† 1 Jitter tolerance for 1Hz input 150 UIpp 1-3,7,9-14,21-22,24-26,29 2 Jitter tolerance for 5Hz input 140 UIpp 1-3,7,9-14,21-22,24-26,29 3 Jitter tolerance for 20Hz input 130 UIpp 1-3,7,9-14,21-22,24-26,29 4 Jitter tolerance for 300Hz input 35 UIpp 1-3,7,9-14,21-22,24-26,29 5 Jitter tolerance for 400Hz input 25 UIpp 1-3,7,9-14,21-22,24-26,29 6 Jitter tolerance for 700Hz input 15 UIpp 1-3,7,9-14,21-22,24-26,29 7 Jitter tolerance for 2400Hz input 4 UIpp 1-3,7,9-14,21-22,24-26,29 8 Jitter tolerance for 10kHz input 1 UIpp 1-3,7,9-14,21-22,24-26,29 9 Jitter tolerance for 100kHz input 0.5 UIpp 1-3,7,9-14,21-22,24-26,29 † See "Notes" following AC Electrical Characteristics tables. AC Electrical Characteristics - 2.048MHz Input Jitter Tolerance Characteristics Sym Min Max Units Conditions/Notes† 1 Jitter tolerance for 1Hz input 150 UIpp 1-3,8,9-14,21-22,24-26,30 2 Jitter tolerance for 5Hz input 140 UIpp 1-3,8,9-14,21-22,24-26,30 3 Jitter tolerance for 20Hz input 130 UIpp 1-3,8,9-14,21-22,24-26,30 4 Jitter tolerance for 300Hz input 50 UIpp 1-3,8,9-14,21-22,24-26,30 5 Jitter tolerance for 400Hz input 40 UIpp 1-3,8,9-14,21-22,24-26,30 6 Jitter tolerance for 700Hz input 20 UIpp 1-3,8,9-14,21-22,24-26,30 7 Jitter tolerance for 2400Hz input 5 UIpp 1-3,8,9-14,21-22,24-26,30 8 Jitter tolerance for 10kHz input 1 UIpp 1-3,8,9-14,21-22,24-26,30 9 Jitter tolerance for 100kHz input 1 UIpp 1-3,8,9-14,21-22,24-26,30 † See "Notes" following AC Electrical Characteristics tables. AC Electrical Characteristics - OSCi 20MHz Master Clock Input Characteristics 1 2 Frequency accuracy (20 MHz nominal) 3 Sym Min Max Units -0 +0 ppm 15,18 -32 +32 ppm 16,19 -100 +100 ppm 17,20 40 60 % 4 Duty cycle 5 Rise time 10 ns 6 Fall time 10 ns † See "Notes" following AC Electrical Characteristics tables. 28 Conditions/Notes† Advance Information MT9044 † Notes: Voltages are with respect to ground (VSS) unless otherwise stated. Supply voltage and operating temperature are as per Recommended Operating Conditions. Timing parameters are as per AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels 1. PRI reference input selected. 2. SEC reference input selected. 3. Normal Mode selected. 4. Holdover Mode selected. 5. Freerun Mode selected. 6. 8kHz Frequency Mode selected. 7. 1.544MHz Frequency Mode selected. 8. 2.048MHz Frequency Mode selected. 9. Master clock input OSCi at 20MHz ±0ppm. 10. Master clock input OSCi at 20MHz ±32ppm. 11. Master clock input OSCi at 20MHz ±100ppm. 12. Selected reference input at ±0ppm. 13. Selected reference input at ±32ppm. 14. Selected reference input at ±100ppm. 15. For Freerun Mode of ±0ppm. 16. For Freerun Mode of ±32ppm. 17. For Freerun Mode of ±100ppm. 18. For capture range of ±230ppm. 19. For capture range of ±198ppm. 20. For capture range of ±130ppm. 21. 25pF capacitive load. 22. OSCi Master Clock jitter is less than 2nspp, or 0.04UIpp where1UIpp=1/20MHz. 23. Jitter on reference input is less than 7nspp. 24. Applied jitter is sinusoidal. 25. Minimum applied input jitter magnitude to regain synchronization. 26. Loss of synchronization is obtained at slightly higher input jitter amplitudes. 27. Within 10ms of the state, reference or input change. 28. 1UIpp = 125us for 8kHz signals. 29. 1UIpp = 648ns for 1.544MHz signals. 30. 1UIpp = 488ns for 2.048MHz signals. 31. 1UIpp = 323ns for 3.088MHz signals. 32. 1UIpp = 244ns for 4.096MHz signals. 33. 1UIpp = 122ns for 8.192MHz signals. 34. 1UIpp = 61ns for 16.384MHz signals. 35. No filter. 36. 40Hz to 100kHz bandpass filter. 37. With respect to reference input signal frequency. 38. After a RST or TRST. 39. Master clock duty cycle 40% to 60%. 40. Prior to Holdover Mode, device was in Normal Mode and phase locked. 41. 1Ulpp = 51ns for 19.44MHz signals. 29 http://www.mitelsemi.com World Headquarters - Canada Tel: +1 (613) 592 2122 Fax: +1 (613) 592 6909 North America Tel: +1 (770) 486 0194 Fax: +1 (770) 631 8213 Asia/Pacific Tel: +65 333 6193 Fax: +65 333 6192 Europe, Middle East, and Africa (EMEA) Tel: +44 (0) 1793 518528 Fax: +44 (0) 1793 518581 Information relating to products and services furnished herein by Mitel Corporation or its subsidiaries (collectively “Mitel”) is believed to be reliable. However, Mitel assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual property rights owned by Mitel or licensed from third parties by Mitel, whatsoever. Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Mitel, or non-Mitel furnished goods or services may infringe patents or other intellectual property rights owned by Mitel. This publication is issued to provide information only and (unless agreed by Mitel in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this publication are subject to change by Mitel without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Mitel’s conditions of sale which are available on request. M Mitel (design) and ST-BUS are registered trademarks of MITEL Corporation Mitel Semiconductor is an ISO 9001 Registered Company Copyright 1999 MITEL Corporation All Rights Reserved Printed in CANADA TECHNICAL DOCUMENTATION - NOT FOR RESALE