Series AM2GW-NZ 2 Watt | DC-DC Converter FEATURES: • RoHS compliant • Ultra wide 4:1 input range • Remote On/Off Control • 9 pin SIP package • • • • Operating temperature -40oC to + 85oC Continuous Short circuit protection High efficiency up to 82% Low ripple and noise Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load (μF) AM2GW-2403S-NZ AM2GW-2405S-NZ AM2GW-2409S-NZ AM2GW-2412S-NZ AM2GW-2415S-NZ AM2GW-4803S-NZ AM2GW-4805S-NZ AM2GW-4809S-NZ AM2GW-4812S-NZ AM2GW-4815S-NZ 9-36 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 18-72 3.3 5 9 12 15 3.3 5 9 12 15 500 400 222 167 133 500 400 222 167 133 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1200 820 680 470 330 1200 820 680 470 330 Efficiency 73 75 78 82 81 72 76 78 81 80 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load (μF) Efficiency (%) AM2GW-2405D-NZ AM2GW-2409D-NZ AM2GW-2412D-NZ AM2GW-2415D-NZ AM2GW-4805D-NZ AM2GW-4809D-NZ AM2GW-4812D-NZ AM2GW-4815D-NZ 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 ±5 ±9 ±12 ±15 ±5 ±9 ±12 ±15 ±200 ±111 ±83 ±67 ±200 ±111 ±83 ±67 1500 1500 1500 1500 1500 1500 1500 1500 ±330 ±270 ±220 ±180 ±330 ±270 ±220 ±180 76 78 82 81 75 77 81 80 Maximum Units Input Specifications Parameters Nominal Typical 24 48 9-36 Voltage range 18-72 Filter Capacitor 24 Vin 40 Maximum Rating 48 Vin 80 Peak Input Voltage time 100 On/Off Control ON – low or open; OFF – high On/Off input current 5 10 * Exceeding the maximum permissible value of 20mA for the Input On/Off current will damage the converter. VDC VDC ms mA Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R6.B Conditions Typical 60 sec At 500VDC > 1000 80 Tel: +1 514 620 2722 1 of 3 Rated Units 1500 VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2GW-NZ 2 Watt | DC-DC Converter Output Specifications Parameters Conditions Voltage accuracy Short Circuit protection Short Circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Typical Maximum Units ±3 Continuous Auto recovery ±0.75 ±1.5 ±0.03 100 LL~HL Load 10~100% At 20MHz Bandwidth % % % %/oC mV p-p General Specifications Parameters Switching frequency Operating temperature Storage temperature Temperature rise Cooling Humidity Case material Weight Dimensions (L x H x W) MTBF Conditions Typical Maximum Units 100% load, Vin nominal With derating above 71oC >100 550 KHz o C o C o C -40 to +85 -50 to +125 Full load 15 Free air convection 35 % 95 Non-conductive black plastic (UL94V-0 rated) 7 g 1.02 x 0.37 x 0.49 inch 26.00 x 9.60 x 12.00 mm >1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified Pin Out Specifications Dimensions 26.00 (1.02) Pin Single Dual 1 2 3 6 7 8 9 - V Input + V Input On/Off Control + V Output N.C. N.C. - V Output - V Input + V Input On/Off Control + V Output Common N.C. - V Output PRINTED FACE 9.60 (0.37) 12.50 (0.49) 0.50 (0.02) 4.00 (0.16) 2.54 (0.10) Derating 0.50 (0.02) Free Air Convection 71º C Output Power (%) 100 2.90 (0.11) 80 1 2 3 2.000 (0.079) 6 7 8 9 0.300 (0.012) 9.60 (0.37) 0.50 (0.02) Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 051e R6.B Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2GW-NZ 2 Watt | DC-DC Converter Control ON/OFF pin connection example: The voltage could be applied through a limiting resistor and a switching diode. The converter is in a low power mode during high level phase. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R6.B Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only