Mean Well GS12U15-P1I 10 ~ 12wac-dc single output wall-mounted type Datasheet

GS12U
10 ~ 12W AC-DC Single Output Wall-mounted type
series
Features :
Universal AC input / Full range
No load power consumption< 0.3W/240VAC
Pass energy star level IV for full series
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class
power (without earth pin)
Protections: Short circuit / Overload / Over Voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / BSMI / CB / FCC
Pass LPS for full series
2 years warranty
SPECIFICATION
ORDER NO.
OUTPUT
GS12U05-P1I
GS12U07-P1I
GS12U09-P1I
GS12U12-P1I
GS12U15-P1I
GS12U18-P1I
SAFETY MODEL NO.
GS12U05
GS12U07
GS12U09
GS12U12
GS12U15
GS12U18
GS12U24
DC VOLTAGE
5V
7.5V
9V
12V
15V
18V
24V
RATED CURRENT
2.0A
1.6A
1.33A
1.0A
0.8A
0.67A
0.5A
CURRENT RANGE
0 ~ 2.0A
0 ~ 1.6A
0 ~ 1.33A
0 ~ 1.0A
0 ~ 0.8A
0 ~ 0.67A
0 ~ 0.5A
RATED POWER
10W
12W
12W
12W
12W
12.06W
12W
120mVp-p
150mVp-p
180mVp-p
200mVp-p
RIPPLE & NOISE (max.) Note.2 75mVp-p
GS12U24-P1I
90mVp-p
90mVp-p
VOLTAGE TOLERANCE Note.3
5.0%
4.0%
4.0%
3.0%
3.0%
3.0%
3.0%
LINE REGULATION
Note.4
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
Note.5
5.0%
4.0%
4.0%
3.0%
3.0%
2.0%
2.0%
500ms, 20ms, 10ms/115VAC at full load
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 30ms/230VAC
90 ~ 264VAC
135 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
47 ~ 63Hz
EFFICIENCY (Typ.)
72%
75%
AC CURRENT
0.31A / 115VAC
0.16A / 230VAC
INRUSH CURRENT (max.)
COLD START 25A / 115VAC
LEAKAGE CURRENT (max.)
0.25mA / 240VAC
>105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE Note.6
76%
77%
79%
80%
80%
45A / 230VAC
115% ~ 135%
Protection type : Clamp by zener diode
U1 Tj 140 typically (U1) Detect on main control IC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
0 ~ +50
WORKING HUMIDITY
20% ~ 90% RH non-condensing
(Refer to output load derating curve)
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
UL60950-1, CSA22.2, BSMI CNS14336 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
CONNECTOR
NOTE
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to FCC part15 class B, EN55022, EN61204-3 class B, BSMI CNS13438
Compliance to EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, light industry level, criteria A
1414.6Khrs min. MIL-HDBK-217F (25 )
DIMENSION
PACKING
65*47*26.5mm (L*W*H)
0.15Kg ; 100pcs / 16Kg / CARTON
PLUG
Standard type P1I: 2.1
CABLE
Standard type UL1185 6ft (4FT only for 5V output) for stock ; Other type available by customer requested
* 5.5
* 9.5mm turning fork type, center positive for stock ; Other type available by customer requested
1.All parameters are specified at 115VAC input, rated load, 25 70% RH Ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation is measured from 10% to 100% rated load.
6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification
provided by the IC manufacturer.
File Name:GS12U-SPEC 2008-05-06
GS12U
10 ~ 12W AC-DC Single Output Wall-mounted type
Mechanical Specification
series
Unit:mm
UL1185 18AWG 1230 50mm for 5V
UL1185 18AWG 1830 50mm for others
17 1
26.5 1
30 10mm
6.3 0.3
65 1
47 1
ID 2.1 x OD 5.5
C"+"
9.5 0.5mm
Plug Assignment
Standard plug: P1I (option)
P1I
1.5 0.2
P/N
OUTPUT
CENTER
+
12.7 0.4
Derating Curve
Static Characteristics(24V)
OUTPUT VOLTAGE (V)
LOAD (%)
100
70
0
10
20
30
Ta (
40
)
50
300
28
250
24
200
20
150
16
100
12
50
8
25
50
70
90
110
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
Ta=25
32
264
INPUT VOLTAGE(VAC)60Hz
File Name:GS12U-SPEC 2008-05-06