0.8 Amp MEGARECTIFIERS GP08A . . . 08J Series Data Sheet Mechanical Dimensions Description JEDEC D0-41 .205 .160 .080 .107 1.00 Min. .031 typ. Features n HIGH TEMPERATURE METALLURGICALLY BONDED CONSTRUCTION n 0.8 AMP OPERATION @ TA = 55°C, WITH NO THERMAL RUNAWAY n SINTERED GLASS CAVITY-FREE JUNCTION n TYPICAL IR < 0.1 µAmp Electrical Characteristics @ 25 oC. GP08A . . . 08J Series Maximum Ratings Units GP08A GP08B GP08D GP08G GP08J Peak Repetitive Reverse Voltage...VRRM 50 100 200 400 600 Volts RMS Reverse Voltage...VR(rms) 35 70 140 280 420 Volts DC Blocking Voltage...VDC 50 100 200 400 600 Volts Average Forward Rectified Current...I F(av) Current 3/8" Lead Length @ TA = 55°C ............................................. 0.8 ............................................... Amps Non-Repetitive Peak Forward Surge Current...IFSM ½ Sine Wave Superimposed on Rated Load ............................................. 2 5 ............................................... Amps Forward Voltage @ 1.0A...VF ............................................. 1.3 ............................................... Volts Full Load Reverse Current...IR(av) Full Cycle Average @ TA = 55°C ............................................. 3 0 ............................................... µAmps ............................................. 5.0 ............................................... ............................................. 5 0 ............................................... µAmps µAmps Typical Junction Capacitance...CJ (Note 1) ............................................. 8.0 ............................................... pF Typical Thermal Resistance...RθJA (Note 2) ............................................. 5 5 ............................................... °C / W Typical Reverse Recovery Time...tRR (Note 3) ......................................... .......................................... µS Operating & Storage Temperature Range...TJ, TSTRG ......................................... -65 to 175 .......................................... °C DC Reverse Current...IR @ Rated DC Blocking Voltage Page 6-2 TA = 25°C TA = 125°C 2.0 GP08A . . . 08J Series 0.8 Amp MEGARECTIFIERS Data Sheet Forward Current Derating Curve Amps 60 Hz RESISTIVE OR INDUCTIVE LOAD 0.375″″ (9.5mm) LEAD LENGTH TA = Ambient Temperature (°°C) Typical Junction Capacitance Non-Repetitive Peak Forward Surge Current TJ = 25°°C f = 1.0 MHZ VSIG = 50mVp-p Amps pF TJ = TJ max. 8.3 mS Single Half Sine Wave (Jedec Method) Number of Cycles @ 60 HZ Reverse Voltage (Volts) Typical Instantaneous Forward Characteristics Typical Reverse Characteristics TJ = 25°°C µS Pulse Width = 300µ 1% Duty Cycle Amps µ Amps TJ = 100°°C TJ = 25°°C Volts Percent of Rated Peak Voltage NOTES: 1. Measured @ 1 MHZ and applied reverse voltage of 4.0V. 2. Thermal Resistance from Junction to Ambient at 3/8" Lead Length, P.C. Board Mounted. 3. Reverse Recovery Condition IF = 0.5A, IR = 1.0A, IRR = 0.25A. Ratings at 25 Deg. C ambient temperature unless otherwise specified. Single Phase Half Wave, 60 HZ Resistive or Inductive Load. For Capacitive Load, Derate Current by 20%. Page 6-3