NED-35 35W Dual Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test 2 years warranty SPECIFICATION MODEL NED-35A CH1 CH2 CH1 CH2 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 4A 1A 2.2A 1A 0.1 ~ 1.5A 0.5 ~ 4A 0.2 ~ 1.3A CURRENT RANGE Note.6 0.5 ~ 5A INPUT CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 80mVp-p CH1: 4.75 ~ 5.5V 2.0% 6.0% 200mVp-p 6.0% LINE REGULATION Note.4 0.5% 1.0% 0.5% 1.0% LOAD REGULATION Note.5 1.5% 3.0% 1.5% 3.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.75A/115VAC 1200ms, 30ms/115VAC at full load 10ms/115VAC at full load 120 ~ 370VDC 81% 0.5 A/230VAC LEAKAGE CURRENT COLD START 45A <2mA / 240VAC OVERLOAD 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -20 ~ +60 WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note 7) HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 120mVp-p RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE ADJ. RANGE PROTECTION OTHERS 35W 32W RATED POWER OUTPUT NED-35B OUTPUT NUMBER (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CB(IEC60950-1) approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 Compliance to EN55022 (CISPR22) Class B / 70% RH Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A 402.7Khrs min. MIL-HDBK-217F (25 99*97*36mm (L*W*H) 0.36Kg; 45pcs/17.2Kg/0.93CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:NED-35-SPEC 2010-10-18 NED-35 35W Dual Output Switching Power Supply Mechanical Specification 20.5 Case No. 905 Unit:mm 36 55 2 3.5 51.5 1 9.5 series 3 5.5 97 8.2 4 55.5 2- M 3 5 6 7 +V ADJ. 3.5 4.5 89 99 6.5 Terminal Pin No. Assignment Assignment DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1 87 3 3.5 74 18 Block Diagram 36 2-M 28 3.5 17.5 Pin No. 5 6 7 7 Assignment Pin No. 1 AC/L 2 AC/N 3 FG 4 DC OUTPUT COM fosc : 60KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:NED-35-SPEC 2010-10-18