AS227-321: PHEMT GaAs IC High Power
SP3T Switch DC–2 GHz
QFN-12
Features
●
●
●
●
●
●
Positive low voltage control (0/2.75 V operation)
Low insertion loss (< 0.5 dB @ 1 GHz)
High isolation (> 25 dB @ 1 GHz)
Excellent IIP3 (63 dBm @ 2.75 V, 27 dBm/tone)
Miniature QFN-12 plastic package
PHEMT process
0.008 (0.20 mm)
Seating Plane
0.118 (3.00 mm)
Pin 1
Indicator
0.001
(0.02 mm)
0.118
(3.00 mm)
Description
0.029
(0.73 mm)
The AS227-321 is a PHEMT GaAs IC SP3T antenna switch
operating in the 900 MHz and 1800 MHz frequency bands.
Switching between the antenna and TX/RX ports is accomplished
with 3 control inputs. When the control inputs are driven with the
appropriate voltages, a low insertion loss path is provided from
an antenna port to an RX or TX port, while the other ports have
high attenuation.
0.007
(0.180 mm)
0.030
(0.75 mm)
± 0.002
(0.05 mm)
0.017
(0.435 mm) Sq.
Pin 1 Indicator
Exposed pad
0.057 (1.45 mm) Sq.
+ 0.004 (0.10 mm)
- 0.006 (0.15 mm)
0.009 (0.23 mm)
+ 0.003 (0.07 mm)
- 0.002 (0.05 mm)
0 022 (0 55 mm)
Electrical Specifications at 25 °C (0, +2.75 V)
Parameter
Frequency
Insertion loss
Ant-RF1, RF2, RF3
DC–0.5 GHz
DC–1.0 GHz
DC–2.0 GHz
Isolation
Ant-RF1, RF2, RF3
DC–0.5 GHz
DC–1.0 GHz
DC–2.0 GHz
Return loss
Ant-RF1, RF2, RF3
DC–0.5 GHz
DC–1.0 GHz
DC–2.0 GHz
Min.
30
24
18
Typ.
Max.
Unit
0.45
0.50
0.70
0.6
0.7
0.9
dB
dB
dB
32
26
20
dB
dB
dB
18
18
14
dB
dB
dB
Operating Characteristics at 25 °C (0, +2.75 V)
Parameter
Condition
IIP3
27 dBm/tone
2nd/3rd harmonic
34.5 dBm
Gate leakage current
34 dBm In @ 2.75 V
Control voltages
VLOW
VHIGH
Frequency
Min.
Typ.
Max.
Unit
824/869 MHz
63
dBm
900 MHz
65
dBc
50
-0.25
2.60
0
2.75
µA
0.25
5.00
V
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200120 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 5, 2005
1
DATA SHEET • AS227-321
Typical Performance Data
0
0
-0.2
-5
Ant-TX
-10
Ant-RX1
-0.6
-15
-0.8
Isolation (dB)
Insertion Loss (dB)
-0.4
Ant-RX2
-1.0
-1.2
-1.4
Ant-RX1
Ant-TX
-20
Ant-RX2
-25
-30
-1.6
-35
-1.8
-40
-2.0
0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
-45
0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Frequency (GHz)
Frequency (GHz)
Insertion Loss vs. Frequency
Isolation vs. Frequency
Truth Table
2.0
1.8
VSWR (dB)
1.6
Ant-RX1
1.4
V1
V2
V3
Ant-RF1
Ant-RF2
Ant-RF3
VHIGH
VLOW
VLOW
Ins. loss
Isolation
Isolation
VLow
VHIGH
VLOW
Isolation
Ins. loss
Isolation
VLOW
VLOW
VHIGH
Isolation
Isolation
Ins. loss
VLOW = 0–0.2 V.
VHIGH = 2.75–5 V.
Ant-TX
Ant-RX2
1.2
Absolute Maximum Ratings
1.0
0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Characteristic
RF input power
Frequency (GHz)
VSWR vs. Frequency
Control voltage
Pin Out
ANT
+6 V
-40 °C to +85 °C
Storage temperature
-65 °C to +150 °C
25 °C/W
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
GND
CBL
GND
V1
V3
N/C
GND
V2
CBL
4 W > 0.5 GHz
0/+6 V control
Operating temperature
ΘJC
CBL
RF3
CAUTION: Although this device is designed to be as robust as
possible, Electrostatic Discharge (ESD) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
RF2
CBL
GND
RF1
Value
DC blocks required. CBL = 47 pF for operation >500 MHz.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
January 5, 2005 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200120 Rev. A
DATA SHEET • AS227-321
Copyright © 2002, 2003, 2004, 2005, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products. These materials are provided by Skyworks as a service to its customers and may be
used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials. Skyworks may make changes to its documentation, products,
specifications and product descriptions at any time, without notice. Skyworks makes no commitment to update the information and shall have no responsibility whatsoever for conflicts,
incompatibilities, or other difficulties arising from future changes to its documentation, products, specifications and product descriptions.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by or under this document. Except as may be provided in Skyworks Terms and Conditions of
Sale for such products, Skyworks assumes no liability whatsoever in association with its documentation, products, specifications and product descriptions.
THESE MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED OR OTHERWISE, RELATING TO SALE AND/OR USE OF SKYWORKS PRODUCTS INCLUDING
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL
PROPERTY RIGHT. SKYWORKS FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS.
SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST
PROFITS THAT MAY RESULT FROM THE USE OF THESE MATERIALS WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications. Skyworks customers using or selling Skyworks products for use in such applications do so at their
own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale.
The following are trademarks of Skyworks Solutions, Inc.: Skyworks™, the Skyworks logo, and Breakthrough Simplicity™. Product names or services listed in this publication are for identification
purposes only, and may be trademarks of Skyworks or other third parties. Third-party brands and names are the property of their respective owners. Additional information, posted at
www.skyworksinc.com, is incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200120 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • January 5, 2005
3
Similar pages