MORNSUN A1505S-1WR Dual/single output dc-dc converter Datasheet

A_S-1WR & B_LS-1WR Series
1W, FIXED INPUT, ISOLATED & UNREGULATED
DUAL/SINGLE OUTPUT DC-DC CONVERTER
Patent Protection
FEATURES
●
●
●
●
●
●
●
●
RoHS
PRODUCT PROGRAM
SIP Package
Output Short Circuit Protection
Low Isolation Capacitance
1000VDC Isolation Voltage
Operating Temperature: -40℃~+85℃
Internal SMD construction
Industry Standard Pinout
RoHS Compliance
APPLICATIONS
Input
Voltage(VDC)
Part
Number
Output
Efficiency
(%)(Typ.)
Current (mA)
Voltage
(VDC)
Max
3.3
303
30
68
5
200
20
70
A0505S-1WR
±5
±100
±10
69
A0509S-1WR
±9
±56
±5
73
A0512S-1WR
±12
±42
±4
75
A0515S-1WR
±15
±34
±3
75
A0524S-1WR
±24
±21
±2
76
5
200
20
73
Nominal
B0303LS-1WR
B0305LS-1WR
B0505LS-1WR
Range
3.3
5
3.0-3.6
4.5-5.5
Min
The A_S-1WR & B_LS-1WR Series are
B0509LS-1WR
9
112
11
73
specially designed for applications where a
B0512LS-1WR
12
83
8
75
group of polar power supplies are isolated from
B0515LS-1WR
15
67
6
75
the input power supply in a distributed power
B0524LS-1WR
24
42
4
76
supply system on a circuit board.
A1205S-1WR
±5
±100
±10
70
A1212S-1WR
±12
±42
±4
75
±15
±34
±3
76
5
200
20
73
B1209LS-1WR
9
112
11
72
B1212LS-1WR
12
83
8
75
B1215LS-1WR
15
67
6
76
Such as: purely digital circuits, ordinary low
A1505S-1WR
±5
±100
±10
70
frequency analog circuits, and IGBT power device
B1515LS-1WR
15
67
6
75
driving circuits.
A2405S-1WR
±5
±100
±10
68
A2412S-1WR
±12
±42
±4
76
±15
±34
±3
76
3.3
303
30
70
B2405LS-1WR
5
200
20
70
B2412LS-1WR
12
83
8
75
B2415LS-1WR
15
67
6
Note:.Models listed with strike-through text have been officially discontinued.
76
These products apply to:
1)
Where the voltage of the input power
supply is fixed (voltage variation ≤ ±10%);
2)
Where isolation is necessary between
input and output (isolation voltage ≤1000VDC);
3)
Where the regulation of the output voltage
and the output ripple noise are not demanding.
MODEL SELECTION
A1215S-1WR
B1205LS-1WR
Rated Power
Package Style
Output Volt age
.
Input Voltage
Product Series
15
10.8-13.2
13.5-16.5
A2415S-1WR
B2403LS-1WR
A0515S-1WR
12
24
21.6-26.4
COMMON SPECIFICATIONS
Item
Test conditions
Min
Typ
Storage humidity
Operating Temperature
MORNSUN Science & Technology Co.,Ltd.
Storage Temperature
Address: No. 5, Kehui St. 1, Kehui development
center, Science Ave., Guangzhou Science City,
Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Temp. rise at full load
Fax:86-20-38601272
Http://www.mornsun-power.com
Lead temperature
-40
-55
1.5mm from case for 10 seconds
MTBF
Weight
The copyright and authority for the interpretation of the products are reserved by MORNSUN
95
%
°C
30
300
Cooling
Short circuit protection*
Units
85
125
20
Case material
Max
Free air convection
Plastic (UL94-V0)
Continuous, ,Auto-recovery
1940
2.3
K hours
g
Specifications subject to change without notice.
A_S-1WR & B_LS-1WR
A/4-2012
Page 1 of 3
TYPICAL CHARACTERISTICS
INTPUT SPECIFICATIONS
Input current
(No load/Full load)
Surge voltage
(1S max)
Test conditions
Min
Typ
5V input
30/260
12V input
12/110
15V input
12/100
24V input
7/55
Max
Units
Tolerance Envelope Graph
+10%
5V input
9
12V input
18
15V input
21
24V input
30
V
OUTPUT SPECIFICATIONS
Min.
Output power
Line regulation
Load regulation
Typ.
0.1
±1.1
For Vin change of ±1%
Max.
Units
+2.5%
ine
-2.5%
-7.5%
10%
50%
100%
Output Current (%)
1
W
120
±1.5
%
10% to 100% load
Output voltage accuracy
l Lo ad
L
Temperature Derating Graph
Test conditions
Output Power(%)
Item
Ty pica
+5%
Nominal
Voltage
mA
Output Voltage
Item
10
20
Follow the tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
100
Switching frequency
Full load, nominal input
100
±0.03
%/°C
200
mVp-p
100
80
60
Safe Operating Area
40
20
0
-40
0
85 105 120
40
o
Operating Temp.( C)
kHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at
Testing of Power Converter section, application notes.
RECOMMENDED CIRCUIT
ISOLATION SPECIFICATIONS
D ua l Outp ut
Item
Test conditions
Min
Isolation voltage
Tested for 1 minute and 1
mA max
1000
Isolation resistance
Isolation Capacitance
Test at 500VDC
Input/Output,100KHz/0.1V
L
L
Typ
Max
Units
Vin
VDC
GND
MΩ
Sing le Ou tpu t
DC DC
Cin
1000
6
15
PF
APPLICATION NOTE
① Requirement on output load
+Vo
Cout
0V
L Cout
-Vo
L
L
+Vo
Vin
DC DC
Cin
Cout
GND
0V
(Figure 1)
To ensure this module can operate efficiently and reliably, During operation, the
minimum output load could not be less than 10% of the full load. If the actual output
power is very small, please connect a resistor with resistance of 10% rated power at the
output end in parallel, or use our company’s products with a lower rated output power
D ual Out p ut
② Overload Protection
Vin
Under normal operating conditions, the output circuit of these products has no
REG
GND
protection against overload. The simplest method is to connect a slow-blow fuse in series
at the input end or add a circuit breaker to the circuit.
③ Recommended testing and application circuit
If you want to further decrease the input ripple or the input inrush current, an “LC”
REG
+Vo
REG
-Vo
REG
+Vo
DC DC
0V
Single Out p u t
Vin
REG
DC DC
GND
0V
filtering network may be connected to the input and output ends of the DC/DC converter,
(Figure 2)
see (Figure 1).
It should also be noted that the inductance and the frequency of the “LC” filtering
network should be staggered with the DC/DC frequency to avoid mutual interference.
Recommended capacitance(Table 1)
Vin
(VDC)
Cin
(μF)
and reliable operation is ensured, the recommended capacitance of its filter capacitor
5
4.7
5
sees (Table 1).
12
2.2
9
④ Output Voltage Regulation and Over-voltage Protection Circuit
15
2.2
12
24
1
15
However, the capacitance of the output filter capacitor must be proper. If the capacitance
is too big, a startup problem might arise. For every channel of output, provided the safe
The simplest device for output voltage regulation, over-voltage and over-current
protection is a linear voltage regulator with overheat protection that is connected to the
input or output end in series (Figure 2).
Single Cout
output (μF)
(VDC)
Dual
output
(VDC)
Cout
(μF)
10
±5
4.7
4.7
±9
2.2
2.2
±12
1
1
±15
0.47
1.The recommended external capacitance please use the
ceramic capacitor;
2. For applications where output power is less than 0.5W in
reality, external capacitors are not recommended.
⑤ No parallel connection or plug and play.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
A_S-1WR & B_LS-1WR
A/4-2012
Page 2 of 3
OUTLINE DIMENSIONS & PIN CONNECTIONS
RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS
(Fro nt View)
2
4
5 6
1.90±0.20
[0.075±0.008]
1
7.62
[0.300]
12.70
[0.500]
0.6±0.10
[0.024 ±0.004]
12.7
[0.500]
7.62
[0.300]
2.13
[0.084]
13.40±0.50
[0.528±0.020]
9.00±0.20
[0.354±0.008]
9.30±0.20
[0.366±0.008]
19.50±0.50
[0.768 ±0.020]
1
2
4
5
6
∅1.00
[0.040]
1.75
[0.700]
(Botto m View)
0.60±0.20
[0.024±0.008]
1.90±0.20
[0.075±0.008]
Note: grid 2.54*2.54mm.
TUBE OUTLINE DIMENSIONS
0.30±0.10
[0.012±0.004]
2.13
[0.084]
8.30[0.327]
(Side Vie w)
11.70[0.461]
17.50[0.689]
F OOT PRINT DETAILS
PIN
Daul
Single
1
Vin
Vin
2
GND
GND
4
-Vo
0V
5
0V
No Pin
6
+Vo
+Vo
Note :
Uni t : mm[inch]
Pin section tole rances:± 0 .10mm[± 0.0 04inch]
Gen eral toleran ces: ± 0.25m m[ ± 0.010 inch ]
5.00[0.197]
N ote :
U nit : mm[inc h]
General tole rances:± 0 .50mm[ ± 0.020inch]
L=530mm[20.866inch] Devices per tube quantity: 25pcs
L=220mm[8.661inch] Devices per tube quantity: 10pcs
Short tube inner package dimensions: 255*170*80mm
Short tube outer package dimensions
(with six inner package box): 375*280*270mm
Long tube inner package dimensions: 580*200*100mm
Long tube outer package dimensions
(with two inner package box): 600*215*220mm
Long tube outer package dimensions
(with three inner package box):600*215*325mm
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the life of
product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. In this datasheet, all the test methods of indications are based on corporate standards.
4. Only typical models listed, other models may be different, please contact our technical person for more details.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
A_S-1WR & B_LS-1WR
A/4-2012
Page 3 of 3
Similar pages