Systemsensor B210LP 200 series intelligent low-profile plug-in detector Datasheet

200 Series
Intelligent Low-Profile
Plug-In Detectors
The System Sensor 200 Series intelligent plug-in
smoke detectors with integral communication provide
point location for alarm communication and selective
maintenance.
Features
• Sleek, low-profile design
• Analog communications
• Low standby current
• Rotary address switches
• Superior EMI protection
• Dual LEDs for 360° visibility
200 Series smoke detectors are intelligent (addressable) detectors
with point ID capability that enable each detector address to be set
with decade address switches to provide exact detector locations.
The sensitivity of 200 Series detectors can be programmed using the
control panel software to suit the environment. In addition, detector
sensitivity is continually monitored and reported to the panel.
The System Sensor 2251B photoelectric detector’s unique
optical sensing chamber is engineered to sense smoke produced by
a wide range of combustion sources. Dual electronic thermistors add
135°F fixed temperature thermal sensing on the 2251TB model.
The 2251BR is a remote test capable detector for use with DNR(W)
duct smoke detectors.
The Acclimate® 2251TMB photoelectric detector includes
thermal detection at 135°F. It uses advanced onboard software to
combine the signals from the photo and thermal elements to create
a true multi-criteria detector capable of rejecting nuisance sources,
but still responding quickly to real fires. Separate photo and thermal
elements also allow the Acclimate detector to provide different
responses to smoke or heat. In addition, the Acclimate detector can
adjust its sensitivity according to its environment.
The 1251B ionization detector incorporates a unique single-source,
dual-chamber design to respond quickly and dependably to a broad
range of fires.
Agency Listings
For exact certification listings for each model, please reference the
respective agency Web site.
Both the 5251B and 5251RB detectors use an innovative
thermistor sensing circuit to produce 135°F fixed and rate-of-rise
thermal detection in low-profile packages. The 5251H model
provides fixed high-temperature detection at 190°F. These thermal
detectors provide cost-effective, intelligent property protection in a
variety of applications.
200 Series Intelligent Detector Specifications
Physical/Operating Specifications
Height
Diameter
Shipping Weight
Operating Temperature Range
UL-Listed Velocity Range
Operating Humidity Range
Thermal Ratings
Electrical Specifications
Voltage Range
Standby Current (max. avg.)
LED Current (max.)
2.0 inches (51 mm)
6.1 inches (155 mm) installed in B210LP base; 4.1 inches (104 mm) installed in B501 base
Heat: 4.8 oz (136 g); Photo/Photo with Heat: 5.2 oz (147 g); Ion: 5.4 oz (153 g)
Ion/Photo: 32°F to 120°F (0°C to 49°C)
Photo with Thermal: 32°F to 100°F (0°C to 38°C)
Thermal: –4°F to 100°F (–20°C to 38°C)
High Temperature: –4°F to 150°F (–20°C to 66°C)
Ion: 0 to 1,200 fpm (0 to 6.1 m/sec)
Photo/Photo with Thermal: 0 to 4,000 fpm (0 to 20 m/sec) (suitable for installation in ducts)
10% to 93% non-condensing
Fixed Temperature Setpoint: 135°F (57°C)
Rate-of-Rise Detection: 15°F/min. (8.3°C/min.)
High Temperature Heat: 190°F (88°C)
15 to 32 VDC peak
300 µA @ 24 VDC (one communication every 5 seconds with LED enabled)
Photo/Photo with Thermal: 300 µA @ 24 VDC (one communication every 5 seconds with LED enabled)
6.5 mA @ 24 VDC (on)
Ordering Information
Part No.
2251B*
2251BR*
2251TB*
2251TMB*
1251B*
5251B*
5251RB*
5251H*
Bases
B501*
B501BP*
B210LP*
B210LPBP*
B200SR*
B200S*
B224RB*
B224BI*
Accessories
SMB600
F110
F110BP
F210
RA100Z
M02-04-01
M02-09-00
XR2B
XP-4
T55-127-000
BCK-200B
WCK-2008
Description
Photoelectric smoke detector
Photoelectric smoke detector, remote test
capable, for use with DNR(W) duct smoke
detectors
Photoelectric smoke detector with thermal
Acclimate multi-criteria smoke detector
Ionization smoke detector
Fixed temperature thermal detector
Rate-of-rise thermal detector
High temperature thermal detector
Accessories
RA100Z
Remote LED
Annunciator
Head also sold separately
(part no. T55-127-000)
4” Flangeless mounting base
4” Flangeless mounting base bulk pack
6” Flanged mounting base
6” Flanged mounting base bulk pack
Standard sounder base
(compatible with B501BH series)
Intelligent addressable sounder base
Relay base
Isolator base
Surface Mounting Kit (flanged)
Accessory Flange Ring for 6” Base
Accessory Flange Ring for 6” Base Bulk Pack
Accessory New Smaller Flange Ring for 6” Base
Remote LED annunciator
Detector test magnet
Telescoping test magnet
Detector removal tool (T55-127-000 included)
Extension for XR2B (5 to 15 ft)
Detector removal head
Black detector kit (10 pack)**
White detector kit (10 pack)**
XR2B
Detector
Removal Tool
* Add “A” for ULC listed product (e.g., 2251BA)
** The BCK-200B and WCK-200B are only applicable to the B210LP
flanged style mounting base and may only be used with 2251B
(photoelectric) and 1251B (ionization) smoke detectors.
3825 Ohio Avenue • St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
©2012 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com
for current product information, including the latest version of this data sheet.
SPDS10601 • 8/12
Similar pages