Arch AKC-3.3S Ac-dc power module Datasheet

VER :A_3
update : 98.04.09
AC-DC Power Module
AKC SERIES
20
Watts
KEY FEATURES
„ Switching Power Module for PCB Mountable
„ Fully Encapsulated Plastic Case
„ Universal Input Range 90-264VAC, 47-440 Hz
„ Regulated Output
„ Low Ripple and Noise
„ Small Size But Higher Wattage
„ Screw Terminal For Optional
„ CE, UL Approval
„ 2-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No.
( Single Output )
Max output wattage
(W)
Model No.
AKC-5S
AKC-7.35S
AKC-9S
AKC-12S
AKC-15S
AKC-24S
20W
20W
20W
20W
20W
20W
Voltage (V.DC.)
3.3V
5V
7.35V
9V
12V
15V
24V
Current (mA) max
4500
±2%
4000
±2%
2730
±2%
2230
±2%
1670
±2%
1340
±2%
840
±2%
Voltage set accuracy
Output
AKC-3.3S
14.85W
Line Regulation (LL-HL) (typ.)
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Load Regulation (0-100%) (typ.)
1%
1%
1%
1%
1%
1%
1%
Minimum load
0%
0%
0%
0%
0%
0%
0%
Efficiency (typ.)
75%
79%
82%
82%
83%
83%
84%
Capacitor Load (max.)
6900 uF
6900 uF
2200 uF
1200 uF
560 uF
330 uF
100 uF
( Dual Output )
Max output wattage
AKC-5D
(W)
20W
20W
Output 1
Output 2
Output 1
Output 2
Voltage (V.DC.)
+5V
-5V
+12V
-12V
+15V
-15V
Current (mA) max
2000
2000
833
833
667
Line Regulation (LL-HL) (typ.)
667
±2%
±2%
±2%
±0.5%
±0.5%
±0.5%
Load Regulation (10-100%) (typ.)
±3%
±3%
±3%
Minimum load
0%
0%
0%
Efficiency (typ.)
79%
82%
82%
±4700 uF
±560 uF
±330 uF
( Triple Output )
Max output wattage
AKC-5S12D
(W)
Voltage (V.DC.)
Current (mA) max
Voltage set accuracy
Output
20W
Output 2
Capacitor Load (max.)
Model No.
AKC-15D
Output 1
Voltage set accuracy
Output
AKC-12D
AKC-5S15D
20W
20W
Output 1
Output 2
Output 3
Output 1
Output 2
5
+12
-12
5
+15
-15
250
250
200
200
2800
±2%
±2%
2800
±2%
Line Regulation (LL-HL) (typ.)
1%
5%
1%
Load Regulation (20-100%) (typ.)
2%
5%
2%
Minimum load
Efficiency (typ.)
Capacitor Load (max.)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
10%
Output 3
±2%
5%
5%
10%
79%
79%
3000 uF / ±220 uF
3000 uF / ±150 uF
-1-
VER :A_3
update : 98.04.09
AC-DC Power Module
AKC SERIES
20
Voltage
Input
Output
Protection
Isolation
Environment
Physical
Watts
90-264 VAC or 100-375 VDC
Frequency (Hz)
47-440 Hz
Current (Full load)
400 mA max. (115 VAC) / 270 mA max. (230 VAC)
Inrush current (<2ms)
30 A max. (115 VAC) / 50 A max. (230 VAC)
Leakage Current
0.75 mA max.
External Fuse (recommend)
2 A slow blow type
Power Saving
230V < 0.5W
Ripple
<0.2% Vout +40mV max (Vp-p)
Noise
<0.5% Vout +50mV max (Vp-p)
Hold-up time (typ.)
13 ms min.
Switching frequency
100 kHz
Over current protection
Above 105% rated output power
Over voltage protection
Zener diode clamp
Short circuit protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Input-FG (V.AC)
1500V
Output-FG (V.AC)
500V
Operating temperature
-25°C…+70°C (with derating)
Storage temperature
-40°C…+85°C
Temperature coefficient
0.02%/°C
Humidity
95% RH
MTBF
>200,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.76 x 1.89 x 0.87 Inches
Case Material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
110 g
Cooling method
Free air convection
Safety
Agency Approvals
EMI
CE, UL, cUL
EMC
(Conducted & Radiated Emission)
( 70.0 x 48.0 x 22.0 mm ) Tolerance ±0.5 mm
EN 55022 class B
EN 55024
EMS (Noise Immunity)
1. All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1μF & 47μF parallel capacitor.
Note
1.
The triple output required a minimum 10% loading on the output to maintain specified regulation.
damage these devices; however they may not meet all listed specification.
2.
Load regulation for triple output:
Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 20% to 100% balanced on all outputs.
3.
Operation under no-load condition will not
Cross regulation for dual output: asymmetrical load 25% / 100% FL
Cross regulation for triple output:
Main output 100% load, auxiliary 100%,other auxiliary25% to 100%.
Auxiliary outputs(V2 and V3):main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%,auxiliary
25%,other auxiliary 25% to 100%.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER :A_3
update : 98.04.09
AC-DC Power Module
AKC SERIES
MECHANICAL DIMENSION
20
Watts
( Top View )
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
PIN#
SINGLE
Dual
Triple
1
FG
FG
FG
2
AC IN (N)
AC IN (N)
AC IN (N)
3
AC IN (L)
AC IN (L)
AC IN (L)
4
NO PIN
NO PIN
-DC OUT
5
-DC OUT
-DC OUT
COMMON
6
NO PIN
COMMON
+DC OUT
7
+DC OUT
+DC OUT
+5V RTN
8
NO PIN
NO PIN
+5V OUT
DERATING
-3-
VER :A_3
update : 98.04.09
AC-DC Power Module
AKC SERIES
20
Watts
SCREW TERMINAL
AKC-A2
PIN#
Single
Dual
Triple
1
FG
FG
FG
2
AC IN (N)
AC IN (N)
AC IN (N)
3
AC IN (L)
AC IN (L)
AC IN (L)
4
NO CONNECT
NO CONNECT
-DC OUT
5
-DC OUT
-DC OUT
COMMON
6
NO CONNECT
COMMON
+DC OUT
7
+DC OUT
+DC OUT
+5V RTN
8
NO CONNECT
NO CONNECT
+5V OUT
PIN#
Single
Dual
Triple
1
AC IN
AC IN
AC IN
2
NO CONNECT
NO CONNECT
-DC OUT
3
-DC OUT
-DC OUT
COMMON
4
NO CONNECT
COMMON
+DC OUT
5
+DC OUT
+DC OUT
+5V RTN
6
NO CONNECT
NO CONNECT
+5V OUT
AKC-A4
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-4-
VER :A_3
update : 98.04.09
AC-DC Power Module
AKC SERIES
20
Watts
AKC-A5
PIN#
Single
Dual
Triple
1
FG
FG
FG
2
AC IN (N)
AC IN (N)
AC IN (N)
3
AC IN (L)
AC IN (L)
AC IN (L)
4
NO CONNECT
NO CONNECT
-DC OUT
5
-DC OUT
-DC OUT
COMMON
6
NO CONNECT
COMMON
+DC OUT
7
+DC OUT
+DC OUT
+5V RTN
8
NO CONNECT
NO CONNECT
+5V OUT
AKC-A7
PIN#
Single
Dual
Triple
1
AC IN
AC IN
AC IN
2
NO CONNECT
NO CONNECT
-DC OUT
3
-DC OUT
-DC OUT
COMMON
4
NO CONNECT
COMMON
+DC OUT
5
+DC OUT
+DC OUT
+5V RTN
6
NO CONNECT
NO CONNECT
+5V OUT
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-5-
Similar pages