Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter FEATURES: • • • • POL delivering 10A output current Programmable output voltage Remote output sense Remote On/Off Control Function • • • • Output Over current protection Over temperature protection Operating temperature -40 to 85ºC Industry standard SMD footprint Models Single output Model Nom. Input Voltage (V) Output Voltage (V) Output Current max (A) Efficiency (%) 5 12 0.75, 1, 1.2, 1.5, 1.8, 2, 2.5, 3.3 0.75, 1, 1.2, 1.5, 1.8, 2, 2.5, 3.3, 5 10 10 97 96 Maximum Units AMPL-0510-UZ AMPL-1210-UZ Input Specifications Parameters Voltage range Nominal Typical 5 12 3~5.5 10~14 Conditions Typical Full Resistive load ±2 0.75~3.63 0.5 V Output Specifications Parameters Set point Voltage accuracy Trim range Remote sense compensation Short Circuit protection Short Circuit restart Line voltage regulation Load voltage regulation Turn-on delay time Rise time Temperature coefficient Ripple & Noise Load transient voltage Setting time Maximum capacitive load R<10Ω Maximum Units % V V Continuous Auto recovery Full Resistive load NL-FL Full Resistive load (0.1~0.9) of Vout ±0.5 ±0.5 2 1.5 ±0.02 50 160 50 At 20MHz Bandwidth Vout < 10% Peak Deviation Min ESR >10mΩ 5000 % of Vin % ms ms %/oC m Vp-p mV μs μF Maximum Units General Specifications Parameters Conditions Typical Switching frequency 100% load 300 KHz o Operating temperature -40 to +85 C o Storage temperature -55 to +125 C Cooling Free air convection Humidity 10 ~ 90 % Weight 7 g Dimensions (L x W x H) 1.30 x 0.53 x 0.27 inches 33.00 x 13.46 x 6.70mm MTBF > 5,000,000hrs, Bellcore TR332, 25 oC NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 1 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter Pin Out Specifications Pin 1 2 3 4 5 6 Dimensions Single +V Input On/Off Control Sense Trim +V out GND Voltage Adjustment Vout (VDC) R trim value in KΩ for 3~5.5V Vin (VDC) R trim value in KΩ for 10~14V Vin (VDC) 0.75 1.0 1.2 1.5 1.8 2.0 2.5 3.3 5.0 Open 80.6 42.2 23.2 15 11.8 6.98 3.16 2.21 Open 41.2 22.6 13 9.09 7.32 4.99 3.09 1.47 Typical Application: With not using a Control function: www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 2 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter With using a Control option: Output ripple and Noise Measurement – test set up: Note: This test set up configuration for measuring the output voltage ripple and the reflected input ripple current is using C1 and C3 tantalum capacitors with ESR<150mΩ and C2 and C4 ceramic capacitors. Efficiency curves versus load current, at 3 ~ 5.5V input for each output voltage setting (25˚C): Vout 0.75V: www.aimtec.com F 055e R3.C Vout 1V: Tel: +1 514 620 2722 3 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter Efficiency curves versus load current, at 3 ~ 5.5V input for each output voltage setting (25˚C): (continued): Vout 1.2V Vout 1.5V Vout 1.8V Vout 2V Vout 2.5V Vout 3.3V www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 4 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter Derating curve at 3 ~ 5.5V input: Output Power (%) Vout 0.75, 1, 1.2, 1.5V: Output Power (%) Vout 1.8, 2V www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 5 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter Output Power (%) Vout 2.5, 3.3V Efficiency curves versus load current, at 10 ~ 14V input for each output voltage setting (25˚C): Vout 0.75V: Vout 1V: Vout 1.2V Vout 1.5V www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 6 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter Efficiency curves versus load current, at 10 ~ 14V input for each output voltage setting (25˚C) (continued): Vout 1.8V Vout 2V Vout 2.5V Vout 3.3V Vout 5V www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 7 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter Derating curve at 10 ~ 14V input: Vout 0.75, 1, 1.2, 1.5V: Vout 1.8, 2, 2.5V C 100 A 1.0 M/S 60 º C B 80 Safe Operating Area B 1.5 M/S 70 º C A 60 40 C 2.0 M/S 70 ºC 20 0 20 30 40 50 60 70 80 85 90 Ambient Temperature º C www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 8 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMPL-UZ 10A Up to 50 Watt | DC-DC Converter Derating curve at 10 ~ 14V input (continued): Output Power (%) Vout 3.3, 5V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 055e R3.C Tel: +1 514 620 2722 9 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only