AIMTEC AMPL-1210-UZ Up to 50 watt | dc-dc converter Datasheet

Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
FEATURES:
•
•
•
•
POL delivering 10A output current
Programmable output voltage
Remote output sense
Remote On/Off Control Function
•
•
•
•
Output Over current protection
Over temperature protection
Operating temperature -40 to 85ºC
Industry standard SMD footprint
Models
Single output
Model
Nom. Input Voltage
(V)
Output Voltage
(V)
Output Current max
(A)
Efficiency
(%)
5
12
0.75, 1, 1.2, 1.5, 1.8, 2, 2.5, 3.3
0.75, 1, 1.2, 1.5, 1.8, 2, 2.5, 3.3, 5
10
10
97
96
Maximum
Units
AMPL-0510-UZ
AMPL-1210-UZ
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
3~5.5
10~14
Conditions
Typical
Full Resistive load
±2
0.75~3.63
0.5
V
Output Specifications
Parameters
Set point Voltage accuracy
Trim range
Remote sense compensation
Short Circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation
Turn-on delay time
Rise time
Temperature coefficient
Ripple & Noise
Load transient voltage
Setting time
Maximum capacitive load
R<10Ω
Maximum
Units
%
V
V
Continuous
Auto recovery
Full Resistive load
NL-FL
Full Resistive load
(0.1~0.9) of Vout
±0.5
±0.5
2
1.5
±0.02
50
160
50
At 20MHz Bandwidth
Vout < 10% Peak Deviation
Min ESR >10mΩ
5000
% of Vin
%
ms
ms
%/oC
m Vp-p
mV
μs
μF
Maximum
Units
General Specifications
Parameters
Conditions
Typical
Switching frequency
100% load
300
KHz
o
Operating temperature
-40 to +85
C
o
Storage temperature
-55 to +125
C
Cooling
Free air convection
Humidity
10 ~ 90
%
Weight
7
g
Dimensions (L x W x H)
1.30 x 0.53 x 0.27 inches
33.00 x 13.46 x 6.70mm
MTBF
> 5,000,000hrs, Bellcore TR332, 25 oC
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
1 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
4
5
6
Dimensions
Single
+V Input
On/Off Control
Sense
Trim
+V out
GND
Voltage Adjustment
Vout (VDC)
R trim value in KΩ for
3~5.5V Vin (VDC)
R trim value in KΩ for
10~14V Vin (VDC)
0.75
1.0
1.2
1.5
1.8
2.0
2.5
3.3
5.0
Open
80.6
42.2
23.2
15
11.8
6.98
3.16
2.21
Open
41.2
22.6
13
9.09
7.32
4.99
3.09
1.47
Typical Application:
With not using a Control function:
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
2 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
With using a Control option:
Output ripple and Noise Measurement – test set up:
Note: This test set up configuration for measuring the output voltage ripple and the reflected input ripple current is using C1 and C3
tantalum capacitors with ESR<150mΩ and C2 and C4 ceramic capacitors.
Efficiency curves versus load current, at 3 ~ 5.5V input for each output voltage setting (25˚C):
Vout 0.75V:
www.aimtec.com
F 055e R3.C
Vout 1V:
Tel: +1 514 620 2722
3 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
Efficiency curves versus load current, at 3 ~ 5.5V input for each output voltage setting (25˚C):
(continued):
Vout 1.2V
Vout 1.5V
Vout 1.8V
Vout 2V
Vout 2.5V
Vout 3.3V
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
4 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
Derating curve at 3 ~ 5.5V input:
Output Power (%)
Vout 0.75, 1, 1.2, 1.5V:
Output Power (%)
Vout 1.8, 2V
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
5 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
Output Power (%)
Vout 2.5, 3.3V
Efficiency curves versus load current, at 10 ~ 14V input for each output voltage setting (25˚C):
Vout 0.75V:
Vout 1V:
Vout 1.2V
Vout 1.5V
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
6 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
Efficiency curves versus load current, at 10 ~ 14V input for each output voltage setting (25˚C)
(continued):
Vout 1.8V
Vout 2V
Vout 2.5V
Vout 3.3V
Vout 5V
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
7 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
Derating curve at 10 ~ 14V input:
Vout 0.75, 1, 1.2, 1.5V:
Vout 1.8, 2, 2.5V
C
100
A
1.0 M/S
60 º C
B
80
Safe Operating Area
B
1.5 M/S
70 º C
A
60
40
C
2.0 M/S
70 ºC
20
0
20
30
40
50
60
70
80
85
90
Ambient Temperature º C
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
8 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMPL-UZ 10A
Up to 50 Watt | DC-DC Converter
Derating curve at 10 ~ 14V input (continued):
Output Power (%)
Vout 3.3, 5V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 055e R3.C
Tel: +1 514 620 2722
9 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only