ETC NFN40-7615 Single and triple output Datasheet

NFS40 and NFN40 SERIES
Single and triple output
•
•
•
•
•
•
•
•
The NFS40 and NFN40 are industry standard 40 Watt power supplies with the
capability to supply 50W in a forced air ambient and to automatically operate
from any voltage between 85VAC and 264VAC. Use of MOSFET based
switching circuits allows for enhanced features such as output regulation down
to zero load (NFN40). Universal input voltage eliminates the need to change
jumpers or switch settings to cater for different or widely varying line voltages.
In addition to the input voltage range, VDE, UL, CSA, EN60950 and IEC950
approvals make the NFS40 and NFN40 ideal for use in equipment installed
throughout the world. The fixed frequency operation of the NFN40 further
reduces emissions below VDE class B and significantly reduces leakage current.
These low profile switchers with high power density are intended for use in
small, digital systems.
[ 2 YEAR WARRANTY ]
SPECIFICATION
5.0 x 3.0 x 1.2 inch package (1U applications)
Industry standard package
Overvoltage and short circuit protection
40W with free air convection
Fixed frequency operation (NFN Series)
NFS40: EN55022, EN55011 conducted emissions level A
NFN40: EN55022, EN55011 conducted emissions level B
UL, VDE and CSA safety approvals
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Output voltage
adjustability
+5V output on triples
Vout on singles
±5.0%
±5.0%
Hold-up time
Line regulation
LL to HL, FL
Main output
Auxiliary outputs
±0.2%
±1.0%
Efficiency
Total regulation
FL to NL
Main output
Auxiliary outputs
±2.0%
±5.0%
Transient response
+5V (1.5A to 3A)
±120mV max. dev.
500µs recovery
Temperature coefficient All outputs
±0.02%/°C
Overvoltage protection
+5V output
Output power limit
Primary power limited
110VAC, 40 Watts
230VAC, 40 Watts
70% typical
Isolation voltage
Input/output
Input/chassis
Switching frequency
NFS
NFN
Approvals and
standards
(See Note 13)
Single outputs
Multiple outputs
VDE0805, EN60950
IEC950, IEC1010, UL1950
CSA C22.2 No. 950
125% ±15% Vout
90W input
power limit
Continuous
Short term
INPUT SPECIFICATIONS
Input voltage range
Universal input
Input frequency range
132VAC, cold start
264VAC, cold start
Safety ground
leakage current
NFS: 110VAC, 60Hz
230VAC, 50Hz
NFN: 132VAC, 60Hz
240VAC, 50Hz
max.
max.
max.
max.
PAGE 24
EN55022 (NFS), FCC part 15
EN55022 (NFN), FCC part 15
EN55022 (NFS and NFN)
EN61000-4-2, level 3
Perf.
EN61000-4-2, level 4
Perf.
EN61000-4-5, level 3
Perf.
EN61000-4-4, level 3
Perf.
EN61000-4-3, level 3
Perf.
EN61000-4-6, level 3
Perf.
Level A
Level B
Level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 2
criteria 2
MIL-HDBK-217E
170,000 hours
Thermal performance
(See Notes 8, 10)
Operating
0°C to +70°C
Non-operating
–40°C to +85°C
50°C ambient temp.,
40W
Convection cooled
Forced air cooling
50W @ 20CFM
50°C to 70°C ambient Derate linearly
to 50% load
Peak (60 seconds)
60W
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
10,000 feet max.
40,000 feet max.
Vibration (See Note 11) 5Hz to 500Hz,
2.4G rms peak
12A max.
24A max.
0.13mA
0.32mA
155µA
261µA
280g (9.88oz)
ENVIRONMENTAL SPECIFICATIONS
85 to 264VAC
120 to 370VDC
EMC CHARACTERISTICS
Conducted emissions
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
MTBF (See Note 9)
47 to 440Hz
Max. input surge
current
3000VAC
1500VAC
Variable
Fixed, 45kHz ±5kHz
Weight
Short circuit protection
14ms
110ms
5% to 80% RH
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
40-50W AC/DC
40 to 50 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENTS
OUTPUT
VOLTAGE
MAX
+5.1V (A)
3A
7A
5A
50mV
±2.0%
+12.0V (B)
2A
3A
2A
120mV
±5.0%
–12.0V (C)
0.35A
1A
0.5A
120mV
±5.0%
+5.1V (A)
4A
7A
5A
50mV
±2.0%
+12.0V (B)
0.35A
1A
0.5A
120mV
±5.0%
–12.0V (C)
0.35A
1A
0.5A
120mV
±5.0%
+5.1V (A)
3A
7A
5A
50mV
±2.0%
+12.0V (B)
2A
3A
2A
120mV
±5.0%
–5.0V (C)
0.35A
1A
0.5A
50mV
±5.0%
+5.1V (A)
3A
7A
5A
50mV
±2.0%
+15.0V (B)
2A
2.5A
2A
150mV
+10.0%/–3.0%
–15.0V (C)
0.35A
1A
0.5A
150mV
±5.0%
+5.1V
6A
12A
8A
100mV
±2.0%
NFS40-7605
NFN40-7605
+12.0V
3.3A
5A
4A
120mV
±2.0%
NFS40-7612
NFN40-7612
+15.0V
2.6A
4A
3.3A
150mV
±2.0%
NFS40-7615
NFN40-7615
+24.0V
1.6A
2.5A
2A
240mV
±2.0%
NFS40-7624
NFN40-7624
(1)
PEAK
(2)
FAN
(3)
RIPPLE
TOTAL
REGULATION
(4)
MODEL NUMBER
(5)
(D)
NFS40-7608
(5,6)
NFN40-7608
(5,6)
NFS40-7628
(12)
NFN40-7628
(12)
NFS40-7607
(5,6)
NFN40-7607
(5,6)
NFS40-7610
(5,6)
NFN40-7610
(5,6)
Notes
1
2
3
4
5
6
7
Natural convection cooled, 40W maximum.
Peak output current lasting less than 30 seconds with duty cycle less than
10%. During peak loading, outputs may go outside of total regulation
limits. Peak total power must not exceed 60W.
Forced air, 20 CFM at 1 atmosphere, 50W maximum.
Figure is peak-to-peak. Output noise is measured across a 50MHz
bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor.
Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also,
0.25<I(A)/I(B)<5.0 to maintain stated regulation. This does not apply to
NFS40-7628 and NFN40-7628 power supplies as both have regulated
auxiliary outputs.
A minimum load of 0.5A is required on the +5V output to obtain full current
from the negative output.
The NFS40 offers the possibility of power sharing between outputs.
Consult factory for details.
8
9
10
11
12
13
Derating curve is application specific for ambient temperatures >50°C, for
optimum reliability no part of the heatsink should exceed 110oC and no
semiconductor case temperature should exceed 115oC.
A 4W minimum load is required to achieve the NFS design MTBF. This
restriction does not apply to the NFN series.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four
major resonances.
The NFS40-7628 and NFN40-7628 have separately linear regulated +12V
and -12V outputs. The loading conditions in note 5 and note 6 do not
apply.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
DERATING CURVE (See Notes 8, 9, 10)
Output Power (Watts)
50W
20 CFM FORCED AIR COOLING
International Safety Standard Approvals
40W
NFS40: VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1044
Licence No. 4389, 2559, 1651 and 1044
NFN40: VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1067
Licence No. 4389, 2559, 1651 and 1044
NATURAL
CONVECTION
COOLING
UL1950 File No. E136005
25W
20W
CSA C22.2 No. 950 File No. LR41062C
4W
4W MIN LOAD REQ. TO ACHIEVE NFS DESIGN MTBF
0°C 10°C
http://www.artesyn.com
20°C
30°C
40°C
50°C
60°C
70°C
PAGE 25
1
40-50W AC/DC
|
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40 to 50 Watt
AC/DC universal input switch mode power supplies
Mechanical notes
NFS40 AND NFN40 PIN CONNECTIONS
J1
-7608, -7628
-7607
-7610
SINGLES
Pin 1
AC Line
AC Line
AC Line
AC Line
Pin 2
AC Neutral AC Neutral AC Neutral AC Neutral
J2
Pin 1
+12V
+12V
+15V
+Vout
Pin 2
+5.1V
+5.1V
+5.1V
+Vout
Pin 3
+5.1V
+5.1V
+5.1V
+Vout
Pin 4
Return
Return
Return
Return
Pin 5
Return
Return
Return
Return
Pin 6
–12V
–5V
–15V
Return
P1/J3 (C)
Pin 1
Safety Ground
A NFS40 models only: In order to meet safety requirements, a non-metallic
stand-off is mandatory for one hole as specified in the mechanical
drawing.
B The ground pad of the mounting hole near P1 allows system grounding
through a metal stand-off.
C To improve conducted noise, the ground pad of the mounting hole near
the output connector should be connected with the ground pad of the
mounting hole near P1 (P1 for NFS40 models and J3 on NFN40 models).
Use metal stand-offs attached to a common metal chassis. This
connection also significantly attenuates common mode noise.
D A standard L-bracket and cover is available for mounting which contains
all screws, connectors and necessary mounting hardware. Details are on
page 72. Order part number ‘NFS40 COVER KIT’.
AC mating connector
Molex 09-50-3031 or equivalent with Molex 08-50-0164 or equivalent crimp
terminals.
DC mating connector
Molex 09-50-3061 or equivalent with Molex 08-50-0164 or equivalent crimp
terminals.
0.156 (3.96) Dia.
(4 Places)
NON-METALLIC
STAND-OFF
(SEE NOTE A) Q1
3.00
(76.2)
J1
5.00
(127.00)
C5
MAXIMUM
COMPONENT
HEIGHT 1.2 inches
1
~
N
~
L
F1
2.550
(64.8)
T1
J2
F 3.15A, H 250VAC
P1/J3 (SEE NOTE C)
0.22 (5.59)
4.55
(115.8)
0.22
(5.59)
ALL DIMENSIONS IN INCHES (mm)
PAGE 26
DS_NFSN40_20000101.PDF
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Similar pages