TECHNOLOGIES Product Data Sheet 2 WATTS UNREGULATED DC/DC CONVERTER HL02U FEATURES ● ● ● ● ● HIGH EFFICIENCY ● LOW OUTPUT NOISE ● NON-CONDUCTIVE CASE LOW COST INTERNAL FILTERING SURFACE MOUNT CONSTRUCTION TEMPERATURE RANGE: -25°C TO +70°C DESCRIPTION The HL02U Series offers an extensive selection of input and output voltages to choose from. These miniature, unregulated DC/DC converters come in 24-pin DIP and SMD packages. This small size is possible through the use of surface mount manufacturing technologies. The HL02U Series utilizes a 110KHz push-pull oscillator in the input stage with internal filtering to reduce the output noise while maintaining good efficiency. The use of surface mount construction and automated manufacturing processes increase consistency and reliability while reducing overall cost. ABSOLUTE MAXIMUM RATINGS Internal Power Dissipation...................................................................0.90W Short Circuit Duration.........................................................................30 Sec Lead Temperature (soldering, 10 seconds max)..............................+300°C * * Note: Refer to Reflow Profile for SMD Models. ORDERING INFORMATION HL02U xxyzz Y/Z /H Device Family HL Indicates DC/DC Converter Model Number Where: xx = Input Voltage y = Number or Outputs (Single "S", Dual "D") zz = Output Voltage Package Option Screening Option DIP Package only Internet: http://www.cdpowerelectronics.com HL02UrevD,10/97 Power Electronics Division, United States Power Electronics Division, Europe 3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 800.547.2537 Fax: 520.770.9369 C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141 Page 1 ELECTRICAL SPECIFICATIONS Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. NOMINAL INPUT VOLTAGE MODEL RATED OUTPUT VOLTAGE RATED OUTPUT CURRENT INPUT CURRENT NO LOAD (VDC) (VDC) (mA) (mA) HL02U05S05 HL02U05S12 HL02U05S15 5 5 5 5 12 15 400 167 133 HL02U12S05 HL02U12S12 HL02U12S15 12 12 12 5 12 15 HL02U15S05 HL02U15S12 HL02U15S15 15 15 15 HL02U24S05 HL02U24S12 HL02U24S15 RATED LOAD EFFICIENCY (mA) (%) 40 40 40 540 480 480 74 83 83 400 167 133 30 30 30 230 210 210 72 79 79 5 12 15 400 167 133 30 30 30 190 170 170 70 78 78 24 24 24 5 12 15 400 167 133 20 20 20 125 110 110 72 78 78 HL02U05D05 HL02U05D12 HL02U05D15 5 5 5 ±5 ±12 ±15 ±200 ±83 ±67 40 40 40 540 490 490 74 82 82 HL02U12D05 HL02U12D12 HL02U12D15 12 12 12 ±5 ±12 ±15 ±200 ±83 ±67 30 30 30 230 210 210 72 79 79 HL02U15D05 HL02U15D12 HL02U15D15 15 15 15 ±5 ±12 ±15 ±200 ±83 ±67 30 30 30 190 170 170 70 78 78 HL02U24D05 HL02U24D12 HL02U24D15 24 24 24 ±5 ±12 ±15 ±200 ±83 ±67 20 20 20 120 110 110 72 78 78 MIN TYP MAX UNITS 4.75 11.4 14.25 22.8 5 12 15 24 30 5.25 12.6 15.75 26.2 100 VDC COMMON SPECIFICATIONS Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. PARAMETER CONDITIONS INPUT Voltage Range Reflected Ripple Current ISOLATION Rated Voltage Test Voltage Resistance Capacitance Leakage Current OUTPUT Rated Power Voltage Setpoint Accuracy Temperature Coefficent Ripple & Noise Line Regulation Load Regulation GENERAL Switching Frequency Package Weight MTTF per MIL-HDBK-217, Rev. F Ground Benign TEMPERATURE Specification Operation Storage Page 2 60 Hz, 10 Seconds 500 500 VISO= 240VAC, 60Hz 1 25 2 BW = DC to 10MHz BW =10Hz to 2MHz High Line to Low Line Rated Load to 1/4 Load 2 ±3 ±0.02 50 10 ±1 ±3 Circuit Stress Method TA = +25°C TA = +70°C -25 -40 -40 mAp-p VDC Vpk GΩ pF µArms ±5 100 ±1.5 ±15 W % %/°C mVp-p mVrms %/% % 110 12 kHz g 200 40 kHr kHr +70 +85 +110 °C °C °C HL02UrevD,10/97 MECHANICAL Package/Pinout "Y" and "Z" 1.285±0.010" (32.64±0.25) 1.285±0.010" (32.64±0.25) 2423 22 0.525±0.010" (13.34±0.25) 2423 22 1514 13 0.525±0.010" (13.34±0.25) HL02UxxyzzY 1 2 3 SIDE VIEWS 0.695±0.015" (17.65±0.38) 10 11 12 0.375±0.005" (9.52±0.13) 0.015±0.005" (0.38±0.13) 0.020±0.002" (0.51±0.05) 0.100±0.010" (2.54±0.25) HL02UxxyzzZ 1 2 3 10 11 12 0.375±0.005" (9.52±0.13) 0.015±0.005" (0.38±0.13) 1514 13 TOP VIEWS 0.020±0.002" (0.51±0.05) 0.100±0.010" (2.54±0.25) END VIEWS 0.125+0.030" -0.000" (3.18+0.76) ( -0.00) 0°-15° 0.600" (15.24) 0.014±0.002" (0.36±0.05) DIP PACKAGE .015±.010" (.38±.25) SMD PACKAGE PIN CONNECTIONS NU = Do Not Use. NC = No Internal Connection. PIN# Duplicate pin functions are internally connected. All dimensions are in inches (millimeters). GRID: 0.100 inches (2.54 millimeters) Typically Marked with: specific model ordered, date code, job code and Logo. RECOMMENDED LAND PATTERN SINGLES DUALS 1 2 3 +VIN NU NU +VIN -VOUT Common 10 11 12 -VOUT +VOUT -VIN Common +VOUT -VIN 13 14 15 -VIN +VOUT -VOUT -VIN +VOUT Common 22 23 24 NU NU +VIN Common -VOUT +VIN RECOMMENDED REFLOW PROFILE 30 sec MAX (>220°C) 0.100" (2.54) 250 235 °C MAX 2423 22 220 1514 13 200 0.040" (1.02) 1 2 3 10 11 12 1.150" (29.21) 190 TEMPERATURE (°C) 0.080" (2.03) 0.730" (18.54) 150 100 90 sec MAX (>190°C) 50 TIME (seconds) HL02UrevD,10/97 Page 3 TYPICAL PERFORMANCE CURVES LOAD CAPACITANCE vs INPUT RISE TIME (All 5 Vout Models) 250 LOAD CAPACITANCE vs INPUT RISE TIME (All 12 Vout Models) 75 150 Capacitance (µF) Capacitance (µF) 200 SAFE OPERATING AREA 100 50 0 60 45 SAFE OPERATING AREA 30 15 0 0 5 10 (mS) 15 0 20 LOAD CAPACITANCE vs INPUT RISE TIME (All 15 Vout Models) 10 (mS) 15 20 EFFICIENCY vs LOAD 100% 50 5 Efficiency Capacitance (µF) 40 30 SAFE OPERATING AREA 20 10 50% 10% 0 0 5 10 15 20 0% 25% 50% 75% 100% Load (mS) VOUT vs LOAD (All Models Normalized) NOTES: 1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the output voltage of HL02U devices is guaranteed to be within 95% of its steady-state value within 100 milliseconds after the input voltage has reached 95% of its steadystate value. Vout 110% 100% 2.) For dual output models, total load capacitance is the sum of the capacitances on the plus and minus outputs. 90% 25% 50% 75% 100% 125% Load Page 4 HL02UrevD,10/97