Cooper GMC-63mA 5 x 20mm medium time-delay glass tube fus Datasheet

HALOGEN
5 x 20mm Medium Time-Delay Glass Tube Fuses
HF
FREE
GMC Series
Rated Current
63mA - 10A
Pb
Electrical Characteristics
% of Amp Rating
Opening Time
100%
None
135%
60 minutes maximum
200%
2 minutes maximum
Agency Information
•
•
•
•
•
Description
•
•
•
•
•
Medium time-delay, low breaking capacity
Available with optional axial leads
5 x 20mm physical size
Glass tube, nickel-plated brass endcap construction
Designed to UL/CSA 248-14
UL Listed, Guide JDYX, File E19180, 63mA-6.3A
UL Recognized Card: (7A-10A) Guide JDYX2, File E19180
CSA Certified, Class 1422-01, File E65063, 63mA-6.3A
MITI Approval, 1A-10A
KC-Mark: Certificate SU05011-4001 (63mA~250mA); SU05011-4002
(300mA~800mA); SU05011-4003 (1A~3.15A); SU05011-4004 (3.5A~6.3A)
Ordering
• Specify packaging code prefix, product number and option code suffix
• For RoHS compliant version (suffix “-R”), drop mA or A from product code
(e.g., GMC-2-R)
Specifications
Product
Number
GMC-63mA
GMC-80mA
GMC-100mA
GMC-125mA
GMC-150mA
GMC-160mA
GMC-200mA
GMC-250mA
GMC-300mA
GMC-315mA
GMC-400mA
GMC-500mA
GMC-600mA
GMC-630mA
GMC-700mA
GMC-750mA
GMC-800mA
GMC-1A
GMC-1.25A
GMC-1.5A
GMC-1.6A
GMC-2A
GMC-2.5A
GMC-3A
GMC-3.15A
GMC-3.5A
GMC-4A
GMC-5A
GMC-6A
GMC-6.3A
GMC-7A
GMC-8A
GMC-10A
Voltage
Rating
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
125
125
125
125
125
125
125
125
Interrupting Rating (Amps)*
250Vac
125Vac
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
100
10,000
100
10,000
100
10,000
10,000
10,000
10,000
10,000
10,000
200
200
200
Typical DC Cold
Resistance
(Ω)**
10.350
4.775
3.400
2.555
2.295
1.395
0.965
0.838
0.685
0.615
0.335
0.282
0.246
0.213
0.213
0.180
0.156
0.098
0.076
0.067
0.043
0.035
0.026
0.025
0.022
0.019
0.014
0.013
0.012
0.012
0.009
0.007
Typical
Pre-Arc I2t
AC†
0.0027
0.0050
0.0094
0.014
0.022
0.022
0.032
0.046
0.081
0.081
0.18
0.41
0.60
0.66
0.85
0.85
0.85
1.8
3.4
5.4
5.8
8.9
13
19
23
25
36
58
88
110
150
200
300
* Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC.
** DC Cold Resistance (Measured at <10% of rated current)
†
Typical Pre-Arching I2t (I2t was measured at listed interrupting rating and rated voltage)
‡
Maximum Voltage drop (Voltage drop was measured at 20°C ambient temperature at rated current)
0711
BU-SB11757
Page 1 of 2
Data Sheet 4395
Maximum
Voltage
Drop (mV)‡
1400
1400
1200
1000
800
730
650
490
580
480
510
370
360
360
340
320
290
250
200
190
160
130
130
130
130
130
120
120
120
120
120
110
110
Dimensions - mm
Time-Current Curves
Drawing Not to Scale
100mA
125mA
150mA
200mA
250mA
315mA 300mA
400mA
500mA
750mA
800mA
1A
1.5A
1.6A
2A
2.5A
3A
3.5A
4A
5A
6A
6.3A
7A
8A
10A
38.10mm
(.38)
63mA
80mA
5.54mm
(.20)
100
10mm 20mm
(2.0) (0.5)
AMP
RATING
21.10mm
(.81)
5.2mm
(+0.1/-0.2)
10
0.65mm
(REF)
• Ratings above 6.3A have a 0.8mm diameter lead
• With TR2 packaging code, lead wire length is 19.05mm
TIME IN SECONDS
38.10mm
(.38)
1
100
10
1
.01
.1
.1
CURRENT IN AMPS
Packaging Code
Product Number Prefix
BKBK1TR2-
Description
100 fuses packed into a cardboard carton
1000 fuses packed into a poly bag
1500 Axial lead fuses packed into tape on a reel (19.05mm lead wire length)
Product Number Suffix
-V
-R
Description
Axial leads - copper tinned wire with nickel plated brass overcaps (place before amp rating; e.g., GMC-V-2)
RoHS compliant version (drop “mA” or “A” from product number when ordering)
Option Code
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result
in significant injury to the user.
© 2011 Cooper Bussmann
www.cooperbussmann.com
0711
BU-SB11757
Page 2 of 2