LinkCom Manufacturing Co., Ltd Model NO. LCVH-100120 Model Name Power Supply Part NO. PLCVH1100120 SIZE 208.4 * 72 * 38.55 mm【8.2 * 2.83 * 1.52 inch】 FEATURES ◆ AC Input 90~305Vac ◆ Protection: OVP / OTP / SCP / OCP ◆ High Operating ambient Temp: -30℃~+70℃ (Refer to output dreating curve) ◆ Power Factor:>0.98@115Vac;>0.95@230Vac;@full load ◆ Safety: UL / TUV / CB / PSE ◆ EMC: CE / FCC ◆ Comply with Indoor/Outdoor Waterproof (IP 67) ◆ Dimension (L*W*H): 208.4 * 72 * 38.55 mm ◆ Dimension (L*W*H): 8.2 * 2.83 * 1.52 inch ◆ ROHS Compliant Module : LCVH-100120 *(9) * * * * * *,# =SEE NOTES BELOW LCVH-100120 MODEL min. SPECIFICATION norm. DC OUTPUT VOLTAGE (V) 12 PRESET ACCURACY (%) *(8) 1 OUTPUT CURRENT(A) *(5) 8 O/P NOISE (P-P, mV) *(3) 250 1 LINE REGULATION (%) *(7) LOAD REGULATION (%) *(6) 1 DC OUTPUT POWER 96 W 88% EFFICIENCY(typ @Full Load) 2000ms,500ms at full load 115VAC/230VAC SETUP,RISE TIME(typ.) HOLD UP TIME 25ms at full load 115VAC/230VAC INPUT VOLTAGE RANGE 90-305VAC, 127-431VDC, Normal:100-277VAC INPUT FREQUENCY Range:47-63Hz, Normal:50-60Hz PF>0.98 @115VAC, PF>0.95@230VAC at full load and rated output voltage ACTIVE POWER FACTOR INRUSH CURRENT (typ) COLD START 65A @ 230VAC AC CURRENT 1.7A/115VAC 0.65A/230VAC <0.45mA/264VAC LEAKAGE CURRENT SHORT CIRCUIT PROTECTION short circuit protection will restart automatically after the fault condition is removed OVER TEMP. PROTECTION shut down and latch off o/p voltage , re-power on to recover OVER V, PROTECTION OVER CURRENT PROTECTION * max. 120%~160% rated output power ; Hiccup mode OPERATING TEMP.*(4) -30 to +70℃(Refer to output dreating curve) STORAGE TEMPERATURE -40 to +80℃ RELATIVE HUMIDITY 10 to +90%, non-cond. 0.03% / ℃ (0-50℃, typ) TEMP. COEFFICIENT SAFETY UL 60950-1 / TUV EN61347-2-13 / CB / PSE CE EN55015 / FCC Part15 EMI WITHSTAND VOLTAGE I/P-O/P:3.75KVAC, O/P-Grnd:0.5KVAC, I/P-Grnd:1.88KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG,O/P-FG :100M Ohms / 500VDC / 25℃ / 70% RH DIMENSIONS(L*W*H) 208.4 * 72 * 38.5 mm【8.2 * 2.83 * 1.52 inch】 NOTES:(1)All parameters not specially mentioned are measured 230VAC input. (2)All specifications Typical @25℃, unless otherwise noted, at normal line and load. (3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth. (4)Specified for free-air convection cooling. (5)Minimum load is NOT required for proper operation . (6)Load regulation measured from 20% to Full load. (7)Line regulation measured from 100VAC to 277VAC. (8)Preset accuracy measured at normal load, 120VAC input. (9)100% Production Tested. ※Reference www.linkcom.com.tw For more information, please contact with: [email protected] LinkCom Manufacturing Co., Ltd Model NO. LCVH-100120 Model Name Power Supply Part NO. PLCVH1100120 SIZE 208.4 * 72 * 38.55 mm【8.2 * 2.83 * 1.52 inch】 DERATE Dimensions Unit :mm【inch】 ※Reference www.linkcom.com.tw For more information, please contact with :[email protected]