Centauri II (APC12) Non-Isolated DC/DC Power Module
Tiny SMT Footprint – 1.8V-12V Input, 0.9V to 3.6V Output
PRELIMINARY
The APC12 Centauri II series is Astec’s recent addition to its non-isolated SMT POL line. With the wide
acceptance of it’s predecessor (APC08 series) and the continuous system requirement for higher load current, the
Centauri platform have been revolutionized to provide 12A load current from it’s original 8A device. The APC12
offers the same standard features common to the Centauri Product Line: wide input voltage range; wide output
voltage range; high efficiency; Positive Output Enable; Power Good signal and Current Sharing. It also adapts the
same Centauri SMT footprint for optimum user flexibility and multiple sourcing.
The APC12 also comes with an output Trim pin, which allows output adjustment from 0.9V to 3.6V through
external resistance programming. It works from a wide input voltage range of 1.8V to 13V and offers an extensive
array of output voltages starting from 0.9V to 3.6V. It is ideal for Point of Load applications and provides the most
flexibility for the ever-changing DSP and ASIC power requirements.
Industry Standard
0.63” x 1.3” x 0.29H SMT
Electrical Parameters
Input
Input range
Input Surge
Efficiency
1.8-6.0VDC and 6.0-13.0VDC
14V
3.3V @ 93.4% (Typical @ 10A)
92.3% (Typical @ 12A)
Control
Enable TTL compatible (Positive Logic)
Special Features
•
•
•
•
•
•
•
•
•
•
Point of Load (POL) applications
High efficiency, 3.3V@94% (25%-75% Load)
Open Frame SMT
Remote On/Off (Positive Enable)
Low output ripple and noise
Regulation to zero load
Programmable Output from 0.9V to 3.6V
Fixed frequency switching (200 KHz)
Power Good Signal (Optional)
Active Current share (Optional)
Output
Regulation
(Line, Load, Temp)
Ripple and noise
Output voltage
adjust range
Transient Response
<3%
75mV - (≥
≥2.5V Output)
50mV - (<2.5V Output)
0.9V to 3.6V (J Version)
typical 5% deviation
with 50% to 75% step
load 200 µS recovery
Environmental Specifications
Safety
•
•
•
Designed to meet:
UL, cUL
60950 Recognized (Pending)
TUV
EN60950 Licensed (Pending)
Operating temperature: -40°C to +85°C
Storage temperature: -40°C to +125°C
MTBF: >1 million hours
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 1 OF 23
Technical Reference Notes
APC12 Centauri II
APC12 Centauri II SERIES
THIS SPECIFICATION COVERS THE REQUIREMENTS
For A New 1.3" X 0.63" X 0.38”(H), 12A Single Output High Efficiency Non-Isolated SMT DC-DC Converter
MODEL NAME
APC12J03
APC12J03-91
APC12K03
APC12M03
APC12Y03
APC12G03
APC12F03
APC12J08
APC12J08-91
APC12K08
APC12M08
APC12Y08
APC12G08
APC12F08
Base Model
With output trim
Base Model
Base Model
Base Model
Base Model
Base Model
Base Model
With output trim
Base Model
Base Model
Base Model
Base Model
Base Model
Vin nominal/
Vin range
3.3V / 1.8-6.0V
3.3V / 1.8-6.0V
3.3V / 1.8-6.0V
3.3V / 1.8-6.0V
3.3V / 2.2-6.0V
3.3V / 3.0-6.0V
5.0V / 4.2-6.0V
8V / 5.6-13.0V
8V / 5.6-13.0V
8V / 5.6-13.0V
8V / 5.6-13.0V
8V / 5.6-13.0V
8V / 5.6-13.0V
8V / 6.0-13.0V
Vout/Iout
0.9V, 12A
0.9V, 12A
1.2V, 12A
1.5V, 12A
1.8V, 12A
2.5V, 12A
3.3V, 12A
0.9V, 12A
0.9V, 12A
1.2V, 12A
1.5V, 12A
1.8V, 12A
2.5V, 12A
3.3V, 12A
Notes: 1. “J” (0.9V) version has a stand alone Output Trim Option (suffix “-9”)
2. Options (suffix):
"-9MA" = Trim with Power Good and Active Current Share
"-J"
= Tray packaging
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 2 OF 23
Technical Reference Notes
APC12 Centauri II
Electrical Specifications
STANDARD TEST CONDITION on a single unit, unless otherwise specified.
TA:
25°C (Ambient Air)
Forced Airflow 200LFM minimum
VIN (P1):
Nominal input (refer to Table in sheet 2)
Enable (P5):
Open
Vo (P2):
Connect to load
Gnd (P3):
Return for Vin and Vo
Trim (P4):
Open
PGood (P6):
Open
P (P7):
Open
ABSOLUTE MAXIMUM RATINGS
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation
of the device is not implied at these or in any other conditions in excess of those given in the operational sections of
the specs. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Input Voltage
Continuous
Transient (100ms)
Continuous
Transient (100ms)
Device
Symbol
Min
Typ
Max
Unit
03
03
08
08
VIN
VIN,trans
VIN
VIN,trans
1.8
5.6
-
-
6.0
7.0
13.0
14.0
Vdc
Vdc
Vdc
Vdc
Operating Temperature
All
TA
-40
-
85
ºC
Storage Temperature
All
TSTG
-40
-
125
ºC
Operating Humidity
All
-
-
-
85
%
INPUT SPECIFICATIONS
Parameter
Operating Input Voltage1
Device
03
08
APC12F08
Symbol
VIN
Min
1.8
5.6
6.0
Typ
3.3
8.0
8.0
Max
6.0
13.0
13.0
Unit
Vdc
Vdc
Vdc
Maximum Input Current2
(VIN = 0 to VIN,max; IO = IO,max)
All
IIN,max
-
-
14.0
A
Input Ripple Current
All
IIN-1
-
250
300
mAp-p
5Hz to 20MHz
Note: 1. Minimum VIN (03 device) for 1V8, 2V5 and 3V3 versions are 2V2, 3V and 4.2V respectively. Minimum
VIN (08 device) for 3V3 is 6.0V.
2. This power module is not internally fused. The use of an input line fuse is recommended.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 3 OF 23
Technical Reference Notes
APC12 Centauri II
Electrical Specifications (continued)
OUTPUT SPECIFICATIONS
Parameter
Output Voltage Setpoint
VIN = VIN, min to VIN, max at
IO =IO,max
Device
0.9V
1.2V
1.5V
1.8V
2.5V
3.3V
Symbol
VO,SET
VO,SET
VO,SET
VO,SET
VO,SET
VO,SET
Min
0.873
1.164
1.455
1.746
2.425
3.200
Typ
0.900
1.200
1.500
1.800
2.500
3.300
Max
0.927
1.236
1.545
1.854
2.575
3.400
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
All
-
-
-
0.5
1.0
±1.5
%
%
%
≥2.5V
<2.5V
-
-
-
75
50
mVPK-PK
mVPK-PK
Output Current
All
3V3
IO
0
0
-
12
12
A
A
External Load Capacitance
Capacitor ESR
All
-
-
-
3000
100
µF
mΩ
Output Current-limit Inception4
All
IO
-
20
-
A
Output Short-circuit Current5
All
-
-
-
-
-
Efficiency
VIN = 1.8V to 6V1
IO = 12A Resistive Load
J03
K03
M03
Y03
G03
F03
η
η
η
η
η
η
73
80
83
86
88
90
76
81
86
87
90
92
79
84
89
90
93
94
%
%
%
%
%
%
VIN = 5.6V to 13V1
IO = 12A Resistive Load
J08
K08
M08
Y08
G08
F08
η
η
η
η
η
η
71
75
79
80
85
88
73
77
81
82
87
90
74
79
83
84
89
91
%
%
%
%
%
%
200
kHz
65
ms
Output Regulation
Line: VIN = VIN, min to VIN, max
Load: IO = IO, min to IO, max
Temp: TA = -40 ºC to +85ºC
Output Ripple and Noise3
Peak-to-Peak: 5 Hz to 20 MHz
Switching Frequency
Turn-On Time (Input to Output)
IO = IO,max; VIN = VIN,nom
All
6
All
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
-
-
-
SHEET 4 OF 23
Technical Reference Notes
APC12 Centauri II
Electrical Specifications (continued)
OUTPUT SPECIFICATIONS (continued)
Parameter
Dynamic Response:
Slew Rate
Load Change: 50% - 75% IO,max
Peak Deviation Settling Time
to VO,nom
Load Change: 50% - 25% IO,max
Peak Deviation Settling Time
to VO,nom
Device
Symbol
Min
Typ
Max
Unit
All
All
All
∆IO/∆t
-
-
0.1
5
100
10
200
A/µs
%VO
µs
All
All
-
-
5
100
10
200
%VO
µs
Output Voltage Overshoot
All
5
%Vo
Passive Resistive Full Load
Note: 3. Ripple specs are specified at 56uF decoupling capacitance for 03 devices and 100uF for 08 devices.
4. This feature is only for module protection and is not intended for customer application. The value is
specified at 25°C ambient air temperature. Operation outside the power-derating curve may result to an
OCP.
5. Pulse train with 90ms period and 1 ms pulse width. Average IOUT equals about zero.
6. Input to Output Turn-on time is defined as the difference between t1 and t2: where t1 is the time when
the input voltage reaches the minimum VIN (VIN = VIN,min) and t2 is the time when the output voltage
reaches its specified range (VO = VO,SET-MIN).
FEATURE SPECIFICATION
Parameter
Output Voltage Adjustment Range7
Module Parallel Capability
VIN = VIN,min to VIN,max at
IO-TOT = (IO,max)/(60%)
Current Sharing to be within:
Device
-9 opt
-9MA opt
Symbol
-
Min
VO
VO
Typ
-
Max
3.6
3.6
Unit
V
V
-9MA opt
-
40
-
60
%IO-TOT
8
Power Good
Open Collector: max sink current
max pull-up voltage
All
All
-
-
5
6
mA
V
Output Enable9
Open Collector TTL compatible
Module ON: Logic High
Module OFF: Logic Low
Collector Current
All
All
All
4.1
0
-
-
14
0.8
60
Vdc
Vdc
µA
Note:
7. Single resistor adjustment or single resistor plus a voltage source adjustment. Refer to sheet 9 for
recommendations on how to trim the output voltage.
8. Refer to Figure 6 for the PGood configuration.
9. Refer to Figure 3 for the Output Voltage Enable configuration.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 5 OF 23
Technical Reference Notes
APC12 Centauri II
Electrical Specifications (continued)
ISOLATION SPECIFICATION
- The APC12 series are Non-Isolated units.
SAFETY APPROVAL
- UL / cUL 60950, and TUV EN60950 - Flammability and temp rise only.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 6 OF 23
Technical Reference Notes
APC12 Centauri II
Basic Operation and Features
The APC08/12 Centauri family was designed specifically to address applications where on board distributed power with Pointof-Load Converters (Conversion needed as close to the IC, usually DSP’s and ASIC’s) is employed. With its wide range input
and flexible programmable output, any change in the load becomes very manageable with little to no impact on time to market.
All of the converters in this family are buck converters. The APC12x03 versions allow 1.8V to 6V input voltage and the
APC12x08 versions allow a 5.6V to 13V input with 14V max surge.
MODULE PIN ASSIGNMENT
There are 4 to 7 surface mount pins on a Centauri module. The availability of pins from individual modules is relevant
to its version / selected option.
PIN #
P1
P2
P3
P4
P5
P6
P7
DESIGNATION
VIN
VO
GND
TRIM
ENABLE
PGood
P
Input Voltage
Output Voltage
Common Ground
Output Voltage Adjustment [OPTION]
Output Voltage Enable
Power Good [OPTION]
Load Current Active Sharing [OPTION]
INDUSTRY STANDARD PINOUT
When ordered with no options, the module comes with only 4 pins – VIN, Gnd, VOUT and Enable – AND IS
COMPATIBLE WITH OTHER LEADING MANUFACTURER’s FOOTPRINT. When the full-featured module is
required: with Output Trim; Active Current Share and Power Good Signal PINs, “-9MA” suffix is added to the
standard part number. Please refer to the Part Number Ordering Scheme for other options (including packaging).
Note: When using the trim function, this module offers much more trim flexibility than the competitive footprint and also
requires a jumper between the two footprints to be source compatible. Contact Factory for details.
VIN
Trim
Current
Share
GND VO
Enable
PGood
Figure 1. Pin Assignment Viewed from Top of Board.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 7 OF 23
Technical Reference Notes
APC12 Centauri II
Typical Application Circuit (Standard Pinout)
Recommended C1 is a low ESR (<100 mΩ) 330 µF tantalum and C2 is a 1 µF ceramic or equivalent. Recommended outputdecoupling capacitor C3 is 56 µF (less than 75 mΩ ESR) for APC12x03 devices and 100µF (less than 40 mΩ ESR) for
APC12x08 devices.
300 µF
Figure 2a. Typical Application Circuit.
Approx 1”
PCB
Output Capacitor or
combination
Approx 1”
1uF ceramic cap
Measure output
ripple across
1uF cap
Figure 2b. Ripple Measurement Setup.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 8 OF 23
Technical Reference Notes
APC12 Centauri II
Enable Pin (Standard configuration)
Pin P5 is functioned to enable the output voltage of a
module. If this pin is left open or connected to ≥ 4.1Vdc
up to 14Vdc, the module is turned on. On the other hand,
if this pin is connected to ground or to a voltage potential
from 0 to 0.8Vdc, the module is turned off. The enable pin
can source current up to 60µA max - suited for typical
open-collector transistors readily available in the market.
For TTL compatibility, Figure 3 shows a 7405 open
collector inverter IC utilized to function the Enable
feature. Other common chips that can do the function are
74S05; 74HCT05; non-inverting - 7407; 74S07; 74HC07.
If SMT packaging is preferred, Fairchild's Tiny Logic
NC7SZ05 or TI's Little Logic SN7SLVC1G06 comes in SOT23
or SC70 packages.
Figure 3. Output Voltage Enable function diagram.
Special Feature Pins (Options):
Trim Function (-9):
Pin P4 is used for output voltage adjustment. The output voltage can be trimmed through an external resistor or through an
external DC supply as described in the succeeding sections.
Method 1: External Trim Resistor.
By connecting an external resistor across P4 and P3 (Gnd), the voltage appearing on pin P2 (Vo) is adjusted to a higher value.
The output voltage of a module can be adjusted up to a maximum value of 3.3V (nominal) or 83% of the input voltage,
whichever is lower. By connecting an external resistor across P4 and P2, Vo is adjusted to a lower value. Only small
reductions, 2%, in voltage are recommended, as adjustment to lower voltages tends to affect the loop compensation of the
module.
Full range adjustment (from 0.9V to 3.6V) can be obtained from a module with the lowest Vo setpoint (0.9Vo).
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 9 OF 23
Technical Reference Notes
APC12 Centauri II
Trim Function (continued)
To adjust Vo to a higher value, please refer to
Figure 4. The required resistor value (Rt) can be
determined through Equation (1) where Vo is the
voltage on P2 before the adjustment and Vot is the
voltage of P2 after Rt is connected.
Rt =
Vref
R1
Vot − Vo
Equation (1)
Figure 4. Output Voltage Trim Setup.
Please refer to related constants given in TABLE 1 to calculate the Equation.
APC08/12x03
APC08/12x08
Vref
Version
R2
R2
0.87V
0.9V
97.6k
210k
TABLE 1. CONSTANTS
1.2V
1.5V
1.8V
8.45k
4.32k
2.94k
17.4k
9.09k
6.04k
2.5V
1.69k
3.48k
3.3V
1.13k
2.32k
R1
3.09k
6.49k
Be aware that the maximum Vo allowed is 3.6V. Please refer to Centauri datasheet.
Example:
Module version: APC08J03-9 (1.8 to 6.0Vin, 0.9Vo).
Requiring to adjust output voltage from Vo = 0.9V to Vot = 1.8V. Vref = 0.87V and R1 = 3.09kΩ (from TABLE 1).
Based on Equation (1), Rt can be determined as 3.0kΩ.
To adjust Vo to a lower value, Rt should be connected between P4 and P2. Equation (2) provides the calculation for Rt.
Rt =
(Vo − Vref )(Vot − Vref )
Vref (Vo − Vot )
R2
Equation (2)
Be aware that the minimum Vo is 0.9V.
Example
Module version: APC08F03-9 (4.0 to 6.Vin, 3.3Vo).
Requiring to adjust the output voltage from Vo = 3.3V to Vot = 3.3 (1-0.02) = 3.234V.
Vo = 3.3V, Vot = 3.234V, Vref = 0.87V, R2 = 1.13kΩ (from TABLE 1).
Based on Equation (1), Rt can be determined as 111.9kΩ.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 10 OF 23
Technical Reference Notes
APC12 Centauri II
Trim Function (continued)
Method 2: External DC Source
By connecting an external DC supply across P4 (Enable) and P3 (GND) through a limiting resistor Rt, (see Figure 5), output
voltage adjustment can also be achieved. Equation 3 provides the relationship between the External DC supply, Vt, and Vo
(where Vo is the desired output voltage).
Rt
 Rt Rt 
Vt = 1 +
+
Vref − Vo
R1
 R1 R2 
Equation (3)
Given: Rt = 10kΩ
Figure 5. External DC source for output trim adjust.
Vo Adjustment to Lower Voltages. This method does not limit the recommended lower Vo adjustment to 2% as mentioned
on previous sections re: Vo adjustment through external trim resistor.
Example:
Module version: APC08G03-9 (3V to 6Vin, 2.5Vo).
Requiring to adjust the output voltage from Vo = 2.5V to 1.8V
Vo = 1.8V, Vref = 0.87V, R1 = 3.09kΩ, R2 = 1.69kΩ (from Table 1). Based on Equation (3), Vt = 3.0V.
Example:
Module version: APC08G03-9 (3V to 6Vin, 2.5Vo).
Requiring to adjust the output voltage from Vo = 2.5V to 0.9V
Vo = 0.9V, Vref = 0.87V, R1 = 3.09kΩ, R2 = 1.69kΩ (from Table 1). Based on Equation (3), Vt = 5.9V.
Vo Adjustment to Higher Voltages
Example:
Module version: APC08G03-9 (3V to 6Vin, 2.5Vo).
Requiring to adjust the output voltage from Vo = 2.5V to 3.3V
Vo = 3.3V, Vref = 0.87V, R1 = 3.09kΩ, R2 = 1.69kΩ (from Table 1). Based on Equation (3), Vt = -1.84V.
If application of negative voltage is not desired, the limiting resistor Rt can either be changed to a lower value (Rt = 1kΩ
Ω, such
that Vt = 0.60V per Equation 3), or use Method 1.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 11 OF 23
Technical Reference Notes
APC12 Centauri II
Power Good Signal Operation (Option (-9MA)):
PG pin provides an output signal indicating the Vout is
operational (TTL logic signal). It can sink current up to a max
of 5mA and can have a maximum external pull-up voltage of
6V. Please see recommended setup shown on Figure 6.
Figure 6. PGood setup.
Active Current Share Operation (Option (-9MA)):
Active Current share pin is compatible with like modules only (APC08 to APC08 or APC12 to APC12). Connecting this pin
directly with the same Pin from another module guarantees current sharing to within 40% to 60% Iout. Note that this pin is not
compatible with competitive modules that employ active current sharing.
To attain efficient current sharing between like modules, the following points are recommended:
a) The modules to be shared should be located as close as possible into the host card.
b) The copper tracks that connect Vo and GND should at least be 0.60" in width with at least 2 oz. Cu.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 12 OF 23
Technical Reference Notes
APC12 Centauri II
Performance Curves – Efficiency
APC12F03 Efficiency vs Load Current
APC12G03 Efficiency vs Load Current
100
100
95
95
85
80
4V input
75
90
Efficiency (%)
Efficiency (%)
90
85
80
3V Input
5V Input
70
4.5V Input
75
6V Input
65
0
2
4
6
8
10
6V Input
70
12
0
2
4
Load Current (A)
Figure 7. APC08F03 Efficiency Curve.
8
10
12
Figure 8. APC08G03 Efficiency Curve.
APC12M03 Efficiency vs Load Current
APC12Y03 Efficiency vs Load Current
95
95
90
90
85
85
Efficiency (%)
Efficiency (%)
6
Load Current (A)
80
75
2.2V Input
1.8V Input
75
3.3V Input
3.3V Input
70
80
70
6V Input
65
6V Input
65
0
2
4
6
8
10
12
0
2
4
Load Current (A)
6
8
10
12
Load Current (A)
Figure 9. APC08Y03 Efficiency Curve.
Figure 10. APC08M03 Efficiency Curve.
APC12K03 Efficiency vs Load Current
APC12J03 Efficiency vs Load Current
90
85
85
80
80
Efficiency (%)
90
75
70
1.8V Input
3.3V Input
65
75
70
1.8V Input
3.3V Input
65
6V Input
6V Input
60
60
0
2
4
6
8
10
L oa d C u r r e n t ( A )
Figure 11. APC08K03 Efficiency Curve.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
12
0
2
4
6
8
10
12
Load Current (A)
Figure 12. APC08J03 Efficiency Curve.
SHEET 13 OF 23
Technical Reference Notes
APC12 Centauri II
Performance Curves - Efficiency (continued)
APC12G08 Efficiency VS. Load Current
95
95
90
90
Efficiency [%]
Efficiency [%]
APC12F08 Efficiency VS. Load Current
85
80
75
Vin = 6V
Vin = 8V
70
Vin = 13V
2
4
6
8
10
80
75
Vin = 6V
70
Vin = 8V
Vin = 13V
65
65
0
85
0
12
2
Load Current [Amp]
Figure 13. APC12F08 Efficiency Curve.
90
85
Efficiency [%]
Efficiency [%]
90
85
80
Vin = 6V
Vin = 8V
Vin = 13V
80
75
70
65
Vin = 6V
60
Vin = 8V
Vin = 13V
55
65
0
2
4
6
8
10
0
12
2
Figure 15. APC12Y08 Efficiency Curve.
85
80
80
Efficiency [%]
Efficiency [%]
90
85
75
70
Vin = 6V
Vin = 8V
Vin = 13V
0
2
4
6
8
8
10
12
APC12J08 Efficiency VS. Load Current
90
55
6
Figure 16. APC12M08 Efficiency Curve.
APC12K08 Efficiency VS. Load Current
60
4
Load Current [Amp]
Load Current [Amp]
65
12
APC12M08 Efficiency VS. Load Current
95
70
10
Figure 14. APC12G08 Efficiency Curve.
APC12Y08 Efficiency VS. Load Current
75
4
6
8
Load Current [Amp]
10
Load Current [Amp]
Figure 17. APC12K08 Efficiency Curve.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
12
75
70
Vin = 6V
65
Vin = 8V
60
Vin = 13V
55
0
2
4
6
8
10
12
Load Current [Amp]
Figure 18. APC12J08 Efficiency Curve.
SHEET 14 OF 23
Technical Reference Notes
APC12 Centauri II
Performance Curves - Thermal Derating Curve
APC12G03-9MA; 3.3V Input
14
14
12
12
10
10
Load Current, A
Load Current, A
APC12F03-9MA; 5V Input
8
6
200LFM
4
300LFM
400LFM
2
0
15
25
35
45
55
65
75
6
4
200LFM
2
500LFM
5
8
300LFM
0
85
5
15
25
35
Ambient Temperature, °C
Figure 19. F03 - Load current vs. ambient temp.
12
10
10
Load Current, A
Load Current, A
14
12
8
6
4
200LFM
2
300LFM
25
35
45
55
65
75
4
200LFM
2
300LFM
400LFM
0
85
5
15
25
12
12
10
10
Load Current, A
Load Current, A
14
8
6
200LFM
4
300LFM
2
75
85
65
75
85
Ambient Temperature, °C
Figure 23. K03 – Load current vs. ambient t temp.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
8
6
4
200LFM
300LFM
0
0
55
65
2
400LFM
45
55
APC12J03-9MA; 5V Input
14
35
45
Figure 22. M03 – Load current vs. ambient temp.
APC12K03-9MA; 3.3V Input
25
35
Ambient Temperature, °C
Figure 21. Y03 – Load current vs. ambient temp.
15
85
6
Ambient Temperature, °C
5
75
8
400LFM
15
65
APC12M03-9MA; 3.3V Input
14
5
55
Figure 20. G03 – Load current vs. ambient temp.
APC12Y03-9MA; 3.3V Input
0
45
Ambient Temperature, °C
5
15
25
35
45
55
65
75
85
Ambient Temperature, °C
Figure 24. J03 – Load current vs. ambient temp.
SHEET 15 OF 23
Technical Reference Notes
APC12 Centauri II
Performance Curve - Thermal Derating (continued)
APC12F08, 8V INPUT
14
Load Current [A]
12
10
8
6
200 LFM
4
400 LFM
2
600LFM
0
5
15
25 35 45 55 65 75
Am bient Tem perature [ oC]
85
Figure 25. F08 – Load current vs. ambient temp.
Figure 26. G03 – Load current vs. ambient temp.
Figure 27. Y03 – Load current vs. ambient temp.
Figure 28. M03 – Load current vs. ambient temp.
APC12J08, 8V INPUT
14
Load Current [A]
12
10
8
6
200 LFM
4
400 LFM
2
600LFM
0
5
Figure 29. K03 – Load current vs. ambient temp.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
15
25 35 45 55 65 75
Am bient Tem perature [ oC]
85
Figure 30. J03 – Load current vs. ambient temp.
SHEET 16 OF 23
Technical Reference Notes
APC12 Centauri II
Performance Curves
APC12F03
Figure 31. Input to Output Delay at 12A load (CH2 = Vo;
CH1 = Enable Voltage).
Figure 32. Output Ripple and Noise at 12A; VIN = 4V; BW
= 20MHz; Ta = 25ºC.
APC12G03
Figure 33. Input to Output Delay at 12A load (CH2 = Vo;
CH1 = Enable Voltage).
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
Figure 34. Output Ripple and Noise at 12A; VIN = 3.0V;
BW = 20MHz; Ta = 25ºC.
SHEET 17 OF 23
Technical Reference Notes
APC12 Centauri II
Performance Curves (continued)
APC12Y03
Figure 35. Input to Output Delay at 12A load (CH2 = Vo;
CH1 = Enable Voltage).
Figure 36. Output Ripple and Noise at 12A; VIN = 3.3V;
BW = 20MHz; Ta = 25ºC.
APC12M03
Figure 37. Input to Output Delay at 12A load (CH2 = Vo;
CH1 = Enable Voltage).
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
Figure 38. Output Ripple and Noise at 12A; VIN = 3.3V;
BW = 20MHz; Ta = 25ºC.
SHEET 18 OF 23
Technical Reference Notes
APC12 Centauri II
Performance Curves (continued)
APC12K03
Figure 39. Input to Output Delay at 12A load (CH2 = Vo;
CH1 = Enable Voltage).
Figure 40. Output Ripple and Noise at 12A; VIN = 1.8V;
BW = 20MHz; Ta = 25ºC.
APC12J03
Figure 41. Input to Output Delay at 12A load (CH2 = Vo;
CH1 = Enable Voltage).
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
Figure 42. Output Ripple and Noise at 12A; VIN = 1.8V;
BW = 20MHz; Ta = 25ºC.
SHEET 19 OF 23
Technical Reference Notes
APC12 Centauri II
Mechanical Specifications
OUTLINE DRAWING
Parameter
Dimension
Device
All
Weight
All
Symbol
L
W
H
-
Min
-
Typ
5 (0.16)
Max
1.300 (33.02)
0.630 (16.00)
0.370 ( 9.34)
10 (0.32)
Unit
in (mm)
in (mm)
in (mm)
g (oz)
PIN / PIN DIMENSION
1.91
Nominal Pin
Dimension
0.055 X 0.102 [in]
Suggested Pad
Dimensions
0.070 X 0.110 [in]
3.18
2.54
Figure 55. Recommended PAD Layout.
Recommended
Pick Up Point –
flat surface of
inductor
Figure 46. Mechanical Outline (in inches).
Figure 56. APC12 Mechanical Outline.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 20 OF 23
Technical Reference Notes
APC12 Centauri II
Mechanical Specifications (continued)
RECOMMENDED LOCATION FOR PICK AND PLACE
The flat top surface of the large inductor (topside of the board) provides a versatile and convenient way of picking up the
module (see Figure 56). A 6-7mm outside diameter nozzle from a conventional SMD machine is recommended to attain
maximum vacuum pick-up. Nozzle travel and rotation speed should be controlled to prevent this off-centered picked-up
module from falling off the nozzle. The use of vision recognition systems for placement accuracy will be very helpful.
RECOMMENDED REFLOW PROFILE
REFLOW NOTES / RECOMMENDATIONS
240
2.
3.
Refer to the recommended Reflow Profile per
Figure 57. Profile parameters exceeding the
recommended maximums may result to
permanent damage to the module.
The module is recommended for topside
reflow process to the host card. For other
orientations, contact factory.
In the event that the module needs to be
desoldered from the host card, some pins
may be detached from the module.
PEAK TEMPERATURE
200°°C - 230°°C
220
200
TEMPERATURE (deg C)
1.
183°°C
180
REFLOW
ZONE
160
140
120
< 80 sec
110°°C
PRE-HEAT ZONE
120 - 180 sec
100
80
SLOPE
< 4°°C /sec
60
40
20
0
0
30
60
90
120
150
180
210
240
270
300
TIME (seconds)
Figure 57. Recommended Reflow Profile.
MODULE MARKINGS / LABELS
Marking shall be permanent and legible.
Please refer to Figure 58 for the module
marking/ label detail.
Note 1
MMM
Model No
FFF
Option
Note 2
YYWW
Year / Work Week
D
Day of Week
PP
nth Panel of the day
LL
Location in the panel
Note 3: Barcode
6 & 7 characters / line
Code 128, 32CPI
0.070" Height
APC12MMMFFF
YYWWDPPLL
Figure 58. Module Label
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 21 OF 23
Technical Reference Notes
APC12 Centauri II
Mechanical Specifications (continued)
PACKING AND SHIPPING
Standard packaging for the modules will be in tape and reel. Jedec-style tray packaging is also available (add suffix
"J" in pn). Please refer to the ordering information. Maximum number of modules in a reel is 250 pcs. The tray can
hold 35 modules max. Please refer to Figure 59 for the T&R carrier dimensions and Figure 60 for the tray dimensions.
Figure 59. Tape/ pocket dimensions
Figure 60. Jedec-style tray dimensions in mm.
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 22 OF 23
Technical Reference Notes
APC12 Centauri II
PART NUMBER CODING SCHEME FOR ORDERING
A
P
x
y
z
C
1
2
x
0
y
-
z
Output Voltage
F = 3.3V
M = 1.5V
G = 2.5V
K = 1.2V
Y = 1.8V
J = 0.9V
Input Voltage Range
3: 1.8V to 6V
8: 5V to 12V
Options
9:
Trim function (exist for “J” version only)
9MA: Trim function plus PGood and Current Sharing
J:
Adding a “J” suffix indicates Jedec style tray packaging;
No suffix “J” defaults to T&R packaging
Please call 1-888-41-ASTEC for further inquiries or
visit us at www.astecpower.com
MODEL: APC12 SERIES
JANUARY 6, 2002 REVISION A (PRELIMINARY)
SHEET 23 OF 23