Total Power MAU306 Mau300 series 2 watt ultra miniature high isolation sip dc/dc single & dual output Datasheet

TOTAL POWER INT'L
MAU300 Series 2 Watt Ultra Miniature High Isolation SIP DC/DC
Converters
Single
& Dual with
Output
Key Features
l SMT Technology
l Miniture Package
l I / O isolation 1000VDC
l Efficiency Up To 83%
l MTBF > 2,000,000 Hours
l Low Cost
+Vo
+Vin
LC
Filter
Bipolar
Push-Pull
Inverter
-Vin
-Vo
+Vo
+Vin
LC
Filter
Bipolar
Push-Pull
Inverter
Com.
-Vin
-Vo
Mechanical Configuration
Pin Connections
0.77 (19.5)
0.40
(10.2)
0.02
(0.5)
0.09
(2.3)
0.10
(2.54)
2
Single Output
Dual Output
1
+Input
+Input
2
-Input
-Input
4
-Output
-Output
5
No Pin
Common
6
+Output
+Output
0.126
(3.2)
0.02
(0.5)
0.01
(0.25)
1
Pin
4
5
6
0.05
(1.25)
Physical Characteristics
0.30
(7.6)
All dimensions typical in inches (mm). Tolerance= +/- 0.01 (+/- 0.25)
Case Size
19.5*7.6*10.2 mm
0.77*0.30*0.40 inches
Case Material
Non-Conductive Black Plastic
Weight
2.7g
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-1-
TOTAL POWER INT'L
MAU300
Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter
Input Surge Voltage
( 1000 mS )
Min.
Max.
Unit.
5VDC Input Models
-0.7
9
VDC
12VDC Input Models
-0.7
18
VDC
24VDC Input Models
-0.7
30
VDC
---
650
mW
Internal Power Dissipation
Environmental Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Operating Temperature
-25
---
+70
]
Storage Temperature
-40
---
+125
]
---
---
95
%
Humidity
Cooling
Free-Air Convection
Model Selection Guide
Model
Number
Input
voltage
Output
Voltage
Output
Current
Output
Current
VDC
VDC
mA (Max.)
mA (Min.)
Input
Current
Max. Load
mA (Typ.)
Input
Current
No Load
mA (Typ.)
Load
Regulation
Efficiency
% (Max.)
% (Typ.)
MAU301
3.3
500
10
452
11
73
MAU302
5
400
8
526
11
76
7
80
7
80
MAU303
12
165
3
495
15
133
2.5
499
MAU305
{5
{200
{4
519
10
77
MAU306
{12
{83
{1.5
504
7
79
MAU307
{15
{66
{1
501
7
79
MAU311
3.3
500
10
185
8
74
MAU312
5
400
8
212
8
78
5
82
5
83
MAU304
MAU313
5
(4.5 ~ 5.5)
60
12
165
3
200
15
133
2.5
200
MAU315
{5
{200
{4
210
8
79
MAU316
{12
{83
{1.5
201
5
82
MAU314
12
(10.8 ~ 13.2)
30
MAU317
{15
{66
{1
200
5
82
MAU321
3.3
500
10
92
8
74
MAU322
5
400
8
108
8
77
5
81
5
82
MAU323
12
165
3
101
15
133
2.5
101
MAU325
{5
{200
{4
105
8
79
MAU326
{12
{83
{1.5
102
5
81
MAU327
{15
{66
{1
100
5
82
MAU324
24
(21.6 ~ 26.4)
15
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-2-
TOTAL POWER INT'L
MAU300
Input Specifications
Parameter
Input Voltage Range
Model
Min.
Typ.
Max.
5V Input Models
4.5
5
5.5
12V Input Models
10.8
12
13.2
24V Input Models
21.6
24
26.4
---
---
0.3
A
Reverse Polarity Input Current
All Models
Input Filter
Unit
VDC
Pi Filter
Output Specifications
Parameter
Conditions
Output Voltage Accuracy
Output Voltage Balance
Min.
Typ.
Max.
Unit
---
{1.0
{3.0
%
Dual Output Balance Load
---
{0.1
{1.0
%
Line Regulation
For Vin Change 1%
---
{1.2
{1.5
%
Load Regulation
Io=20% to 100%
See Model Selection Guide
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Line,Load & Temp.
Ripple & Noise (20MHz)
%
---
100
150
mV P-P
---
---
200
mV P-P
---
---
5
mV rms.
Over Load
120
---
---
%
Temperature Coefficient
---
{0.01
{0.02
%/]
Output Short Circuit
0.5 Second Max.
General Specification
Parameter
Rated Isolation Voltage
Isolation Resistance
Isolation Capacitance
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1000
---
---
VDC
500VDC
1000
---
---
M[
100KHz,1V
---
80
120
pF
50
80
100
kHz
Switching Frequency
Typical Applications
+
+Vin
Fuse
DC Power
Source
-
+Out
+Vin
Fuse
Single Output
DC / DC
Converter
-Vin
+
Load
DC Power
Source
-Out
-
Dual Output
DC / DC
Converter
-Vin
+Out
Load #1
Common
Load #2
-Out
Input Fuse Selection Guide
5V Input Models
12V Input Models
24V Input Models
1000mA Slow - Blow Type
500mA Slow - Blow Type
200mA Slow - Blow Type
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-3-
TOTAL POWER INT'L
MAU300
Derating Curve
Output
Power
%
100
100
80
80
60
60
40
40
-3% / OC
20
Output
Power
%
20
0
0
-25
-10
0
20
40
60
Ambient Temperature
80
100
125
O
C
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
Single Output
Dual Output
NOTE:
1. Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
2. Other input and output voltage may be available,Please contact factory.
3. Specifications subject to change without notice.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: [email protected] http://www.total-power.com
-4-
Similar pages