LUXEON K High efficacy plug and play array solution with precise flux, Vf and color Introduction The LUXEON K arrays deliver high flux at high efficacy in a small, easy to use package. The high lumen density enables high light output in thermally and space constrained systems like retrofit lamps and high efficiency in systems like downlights aiming for high energy efficiency. The small size bolt down package enables simple assembly in space constrained systems. With Freedom from Binning, every LUXEON K white product falls within a single 3-step MacAdam ellipse positioned around the center point of the ANSI nominal CCT bins to deliver tight Correlated Color Temperature control to ensure consistency in system color point. In addition, these parts deliver the lumen maintenance and reliability that all LUXEON LEDs are renowned for. This document contains the performance data needed to design and engineer LUXEON K based applications. Features Benefits Key Applications • Fully characterized ‘light source’ with • Drop-in solution for cost • Downlights Freedom from Binning • High flux density and lumen offerings of 400-5000+ • CCTs from 2700K to 6500K and Royal Blue • High flux density for compact lamp solutions • 3 SDCM color consistency • Industry’s smallest Vf (+/- 5%) competitive applications • Exceptional lamp to lamp consistency (<3MA) • Single color, flux, or Vf bin • Easy mechanical assembly • Reduction in total cost – no binning or PnP • Faster time to market – ease of design/assembly & flux range (+/- 10%) • LM-80 test reports available • Comprehensive and enabling ecosystem LUXEON K Datasheet DS102 ©2014 Philips Lumileds Lighting Company. • Lamps Table of Contents General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Average Lumen Maintenance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Optical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Electrical Lead Soldering Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Mechanical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Relative Spectral Distribution vs. Wavelength Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Light Output Characteristics over Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Typical Forward Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Typical Radiation Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Packaging on Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 LUXEON K White ANSI Color Bin Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. i General Information Product Nomenclature LUXEON K products are specified and binned “hot” (Tj = 85°C) under conditions comparable to those found in “real-world” lighting products. The part number designation is explained as follows: LXKA-PBCD-EFGHJ Where: A — B — designates minimum CRI performance (value 8 = 80 minimum, value 9 = 90 minimum, value 0 for Royal Blue) designates color (value W = White, value R = Royal Blue) C, D — designates nominal ANSI CCT (value 27 = 2700K, 30 = 3000K, 35 = 3500K, 40 = 4000K, 50 = 5000K, and 04 = Royal Blue 447.5nm - 452.5nm peak wavelength) E, F — custom spec designation or multi-junction designation (F - Number of strings, H number of emitters, for example 0206, 2 strings of 3 = total emitters of 6) G, H — emitter count J denotes a flux upgrade (e.g, A, B, C, etc) — Therefore, 3000K products specified at 350 mA 85°C follow the part numbering scheme: L X K 8 - P W 3 0 - 0 0 0 4 for LUXEON K White 3000K 4-up L X K 8 - P W 3 0 - 0 0 0 8 for LUXEON K White 3000K 8-up L X K 0 - P R 0 4 - 0 0 0 8 for LUXEON K Royal Blue 8-up Average Lumen Maintenance Characteristics Lumen maintenance for solid-state lighting devices (LEDs) is typically defined in terms of the percentage of initial light output remaining after a specified period of time. Philips Lumileds projects that LUXEON K products will deliver, on average, 70% lumen maintenance (L70) at 50,000 hours of operation at a forward current of up to 700 mA. This projection is based on constant current operation with junction temperature maintained at or below 125°C. This performance is based on independent test data, Philips Lumileds historical data from tests run on similar material systems, and internal LUXEON reliability testing. Observation of design limits included in this data sheet is required in order to achieve this projected lumen maintenance. Environmental Compliance Philips Lumileds is committed to providing environmentally friendly products to the solid-state lighting market. LUXEON K is compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the RoHS directive. Philips Lumileds will not intentionally add the following restricted materials to the LUXEON K: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE). LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 2 Product Selection Product Selection Guide for LUXEON K White, Junction Temperature = 85°C Table 1. Nominal CCT Emitter Count Part Number Test Current (mA) Minimum CRI Typical CRI Minimum Flux (lm) Typical Flux (lm) Maximum Flux (lm) 3 LXK8-PW27-0403 87.5 80 83 270 285 320 2700 4 LXK8-PW27-0004A 350 80 83 360 401 430 2700 * 4 LXK8-PW27-0404 87.5 80 83 340 370 410 2700 * 6 LXK8-PW27-0206 175 80 83 530 555 640 2700 8 LXK8-PW27-0008A 350 80 83 730 765 870 2700 12 LXK8-PW27-0012A 350 80 83 1100 1148 1320 2700 16 LXK8-PW27-0016A 350 80 83 1480 1530 1770 2700 24 LXK8-PW27-0024A 350 80 83 2230 2378 2670 3000 * 3 LXK8-PW30-0403 87.5 80 83 270 285 320 3000 4 LXK8-PW30-0004A 350 80 83 380 426 450 3000 * 4 LXK8-PW30-0404 87.5 80 83 355 385 420 3000 * 6 LXK8-PW30-0206 175 80 83 540 575 650 3000 8 LXK8-PW30-0008A 350 80 83 760 783 910 3000 12 LXK8-PW30-0012A 350 80 83 1140 1200 1360 3000 16 LXK8-PW30-0016A 350 80 83 1520 1568 1820 3000 24 LXK8-PW30-0024A 350 80 83 2280 2445 2730 3500 4 LXK8-PW35-0004 350 80 83 400 423 480 3500 8 LXK8-PW35-0008 350 80 83 820 845 980 3500 12 LXK8-PW35-0012 350 80 83 1200 1265 1440 3500 16 LXK8-PW35-0016 350 80 83 1590 1703 1900 2900 2700 * 3500 24 LXK8-PW35-0024 350 80 83 2420 2570 4000 * 3 LXK8-PW40-0403 87.5 80 83 310 330 370 4000 4 LXK8-PW40-0004A 350 80 83 420 445 500 4000 * 4000 * 4 LXK8-PW40-0404 87.5 80 83 410 430 490 6 LXK8-PW40-0206 175 80 83 625 660 750 4000 8 LXK8-PW40-0008A 350 80 83 820 886 980 4000 12 LXK8-PW40-0012A 350 80 83 1250 1329 1500 4000 16 LXK8-PW40-0016A 350 80 83 1680 1860 2010 4000 24 LXK8-PW40-0024A 350 80 83 2530 2660 3030 5000K 4 LXK8-PW50-0004 350 80 83 440 463 530 5000K 6 LXK8-PW50-0206 350 80 83 640 675 770 5000K 8 LXK8-PW50-0008 350 80 83 890 933 1070 5000K 12 LXK8-PW50-0012 350 80 83 1310 1389 1570 5000K 16 LXK8-PW50-0016 350 80 83 1760 1850 2110 5000K 24 LXK8-PW50-0024 350 80 83 2650 2767 3180 Table 1 continued on page 4. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 3 Table 1 Continued. Nominal CCT Emitter Count Part Number Test Current (mA) Minimum CRI Typical CRI Minimum Flux (lm) Typical Flux (lm) Maximum Flux (lm) 3000 8 LXK7-PW30-0008 350 70 73 1020 1070 1225 3000 12 LXK7-PW30-0012 350 70 73 1490 1565 1785 3000 16 LXK7-PW30-0016 350 70 73 2005 2105 2405 4000 8 LXK7-PW40-0008 350 70 73 1020 1071 1225 4000 12 LXK7-PW40-0012 350 70 73 1560 1638 1870 4000 16 LXK7-PW40-0016 350 70 73 2040 2150 2445 2700 4 LXK9-PW27-0004 350 90 93 300 320 360 2700 8 LXK9-PW27-0008 350 90 93 610 640 730 2700 12 LXK9-PW27-0012 350 90 93 940 960 1120 2700 16 LXK9-PW27-0016 350 90 93 1265 1280 1510 2700 24 LXK9-PW27-0024 350 90 93 1880 1925 2250 3000 4 LXK9-PW30-0004 350 90 93 320 350 380 3000 8 LXK9-PW30-0008 350 90 93 660 695 790 3000 12 LXK9-PW30-0012 350 90 93 1010 1050 1210 3000 16 LXK9-PW30-0016 350 90 93 1350 1400 1620 3000 24 LXK9-PW30-0024 350 90 93 2045 2110 2450 2700** 4 LXK8-PW27-0004 350 80 83 310 345 370 ** 2700 8 LXK8-PW27-0008 350 80 83 680 690 810 2700** 12 LXK8-PW27-0012 350 80 83 990 1045 1180 2700** 16 LXK8-PW27-0016 350 80 83 1380 1395 1650 2700 24 LXK8-PW27-0024 350 80 83 1960 2090 2350 3000** 4 LXK8-PW30-0004 350 80 83 330 370 390 3000** 8 LXK8-PW30-0008 350 80 83 730 740 870 ** ** 3000 12 LXK8-PW30-0012 350 80 83 1070 1125 1280 3000** 16 LXK8-PW30-0016 350 80 83 1475 1500 1770 2520 3000 24 LXK8-PW30-0024 350 80 83 2100 2250 4000** 4 LXK8-PW40-0004 350 80 83 380 410 450 4000** 8 LXK8-PW40-0008 350 80 83 780 815 930 ** 4000** 12 LXK8-PW40-0012 350 80 83 1120 1240 1340 4000** 16 LXK8-PW40-0016 350 80 83 1590 1650 1900 4000** 24 LXK8-PW40-0024 350 80 83 2260 2475 2710 Notes for Table 1: 1. Philips Lumileds maintains a tolerance of ± 6.5% on luminous flux and ± 2 on CRI measurements. 2. * = High voltage multi-junction. 3. ** = Parts with original flux performance (before flux upgrade). Product Selection Guide for LUXEON K Royal Blue, Junction Temperature = 85°C, Test Current = 350 mA Table 2. Color Emitter Count Part Number Minimum Radiometric Power (mW) Typical Radiometric Power (mW) Maximum Radiometric Power (mW) Typical Radiant Efficiency (%) Royal Blue 8 LXK0-PR04-0008 4500 4670 5400 62% Royal Blue 16 LXK0-PR04-0016 9000 9350 10800 62% LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 4 Optical Characteristics LUXEON K White at Test Current, Junction Temperature = 85°C Table 3. Nominal CCT Part Number Color Temperature CCT Typical Typical Total Included Angle [2] (degrees) u90V Typical Viewing Angle [2] (degrees) 2u ½ LXKx-PW27-xxxx(A) 2700K 2725K 125 100 LXKx-PW30-xxxx(A) 3000K 3045K 125 100 LXKx-PW35-xxxx 3500K 3465K 125 100 LXKx-PW40-xxxx(A) 4000K 3985K 125 100 LXKx-PW50-xxxx 5000K 5028K 125 100 Notes for Table 3: 1. Total angle at which 90% of total luminous flux is captured. 2. Viewing angle is the off axis angle from lamp centerline where the luminous intensity is ½ of the peak value. LUXEON K Royal Blue (LXK0-PRxx) at Test Current [1], Junction Temperature = 85°C Table 4. Peak Wavelength, lp[2] Min Typ Max Typical Spectral Half-width (nm)[3] Dl1/2 447.5nm 450nm 452.5nm 20 Part Color Royal Blue Typical Temp Coefficient of Peak Wavelength (nm/°C) Dl1/2 Typical Total Included Angle [4] (degrees) u90V Typical Viewing Angle [5] (degrees) 2u ½ 0.05 140 116 Notes for Table 4: 1. Test current is 350 mA for all LXK0-PRxx products. 2. Royal Blue product has single peak wavelength bin. 3. Spectral half-width is ½ of the peak intensity. 4. Total included angle at which 90% of total radiometric power is captured. 5. Viewing angle is the off-axis angle from lamp centerline where the luminous intensity is ½ of the peak value. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 5 Electrical Characteristics Electrical Characteristics at Test Current for LUXEON K White and Royal Blue, Junction Temperature = 85°C Table 5. Forward Voltage Vf [1] (V) Part Number Typical Temperature Coefficient of Forward Voltage (mV/°C) DVF / DTJ Typical Thermal Resistance Junction to Case (°C/W) Ru J-C Minimum Typical Maximum LXKx-Pxxx-0403 30 31.5 33.8 -21.0 5.5 LXKx-Pxxx-xx04(A) 10 10.5 11.3 -6.3 3.0 LXKx-Pxxx-x404 40 42 45.1 -30.1 3.0 LXKx-Pxxx-xx08(A) 20 21 22.6 -12.5 1.5 LXKx-Pxxx-x206 30 31.5 33.8 -21.0 2.3 LXKx-Pxxx-xx12(A) 30 31.5 33.8 -18.8 1.0 LXKx-Pxxx-xx16(A) 40 42 45.1 -25.0 0.8 LXKx-Pxxx-xx24(A) 60 63 67.7 -37.5 0.5 Notes for Table 5: 1. Philips Lumlileds maintains a tester tolerance of 0.5% on forward voltage measurements. 2. Junction temperature to back of the PCB. Typical Electrical Characteristics at Twice the Test Current for LUXEON K White and Royal Blue, Junction Temperature = 85°C Table 6. Part Number Typical Forward Voltage Vf (V) Test Current (mA) LXKx-Pxxx-x403 36 87.5 LXKx-Pxxx-xx04(A) 11 350 LXKx-Pxxx-x404 48 87.5 LXKx-Pxxx-xx08(A) 22 350 LXKx-Pxxx-x206 36 175 LXKx-Pxxx-xx12(A) 33 350 LXKx-Pxxx-xx16(A) 44 350 LXKx-Pxxx-xx24(A) 66 350 LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 6 Absolute Maximum Ratings Table 7. Maximum Performance Parameter LXKx-Pxxx-x004/x006/x008/ x012/x016/x024 LXKx-Pxxx-x403/x404 LXKx-Pxxx-x206 DC Forward Current (mA) 1050 300 600 Peak Pulsed Forward Current (mA) 1050 300 600 ESD Sensitivity < 8000V Human Body Model (HBM) Class 3A JESD22-A114-E < 400V Machine Model (MM) Class B JESD22-A115-B LED Junction Temperature [1] 125°C Operating Case Temperature -40°C - 125°C Storage Temperature -40°C - 125°C Reverse Voltage (Vr) See Note 2 Notes for Table 7: 1. Proper current derating must be observed to maintain junction temperature below the maximum. 2. LUXEON Power LEDs are not designed to be driven in reverse bias. Electrical Lead Soldering Characteristics Please refer to Application Brief AB102 for LUXEON K. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 7 Mechanical Dimensions LXKx-Pxxx-xxx3 Figure 1. Dimensions for LXKx-Pxxx-xxx3. Notes for Figure 1: 1. All dimensions are in millimeters. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 8 LXKx-Pxxx-xxx4(A) 3 1. (2 50 PL C PL 17.67 17.47 C S) B 7.50 (2PLCS) 3.62 3.22 1.50 (2PLCS) 9.40 R0.50 45 0.31 (2PLCS) 2 (2PLCS) 19.1 18.8 5 5 3.30 Dome Pitch 5.46 (2PLCS) 6.25 (2PLCS) 2. 86 1.65 2.10 .0 ° 8.50 (2PLCS) 0.50 Max. runner height from PCB surface S) (2 A 6.25 (2PLCS) 72 5. (2 PL A (2 C PL S) S) C 1 0.76 Silicone height from PCB surface 3.30 Dome Pitch R1.50 (4PLCS) 1.65 1.265 1.045 Board Thickness 3.40 3.20 (2PLCS) 2.40 2.20 (2PLCS) DETAIL A SCALE 10 : 1 0.50 3.45 2D Barcode 45.0° 1.90 6.90 R1 (2X) 5. 5 9 3.30 Wire slot (2PLCS) R1 (2PLCS) R0.50 (5PLCS) 3.45 6.90 R1 (2PLCS) DETAIL B Figure 2. Dimensions for LXKx-Pxxx-xxx4(A). Notes for Figure 2: 1. All dimensions are in millimeters. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 9 LXKx-Pxxx-xxx6 Figure 3. Dimensions for LXKx-Pxxx-xxx6. Notes for Figure 3: 1. All dimensions are in millimeters. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 10 LXKx-Pxxx-xx08(A) 1. 50 (2 PL PL 3.62 3.22 C C S) S) 0.50 Max. runner height from PCB surface B 2 (2PLCS) 1.50 (2PLCS) 45 .0° 0.15 (2PLCS) 7.13 (2PLCS) 2. 80 5. 60 (2 (2 PL PL 22.65 22.35 C C 5.77 (2PLCS) 10.95 10.75 (2PLCS) 10 9.95 (2PLCS) 9.75 3 (2 5 .6 5 21 1.3 2 2 21 1.7 .2 5 5 A 8.98 (2PLCS) S) S) A 4.60 R1.50 (8PLCS) 0.76 Silicone height from PCB surface 1 3.35 3.25 (2PLCS) 1.265 1.045 Board Thickness 2 DETAIL A SCALE 8 : 1 2.45 2.35 2.25 (2PLCS) 3.85 2D Barcode 0.64 5.46 3.87 5.65 R1 (2PLCS) 45.0° 5.53 51.43° Dome Array (7X) 5.43 DETAIL B 3.30 Wire slot (2PLCS) R1 (2PLCS) Figure 4. Dimensions for LXKx-Pxxx-xxx8(A). Notes for Figure 4: 1. All dimensions are in millimeters. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 11 LXKx-Pxxx-xx12(A) 3 (2 PL C PL (2 2 23 4.4 .9 5 5 50 1. A S) C 8.37 (2PLCS) 1.50 (2PLCS) 45.0° 0.80 (2PLCS) 80 60 5. (2 25.15 24.85 C S) A 10.97 (2PLCS) C PL (2 PL 3.30 (3PLCS) Dome Pitch S) 2. 4.63 (2PLCS) 2 (2PLC 6 12.10 11.90 (2PLCS) 0.50 Max. runner height from PCB surface 1.65 10.70 11.10 10.90 (2PLCS) S) B 3.62 3.22 2 24 4.3 .0 5 5 S) 5.80 0.76 Silicone height from PCB surface 3.30 (3PLCS) Dome Pitch R1.50 (12PLCS) 1.65 1.265 1.045 Board Thickness 3.35 3.25 (2PLCS) 1 2.35 2.25 (2PLCS) 2 DETAIL A SCALE 8 : 1 13.50 6.75 R1 (8X) ire slo 3.3 t( 0 2P LC S) 2D Barcode W 13.50 R1 (2PLCS) 6.75 DETAIL B 3.35 x 45 Chamfer (4PLCS) ) PLCS R1 (2 Figure 5. Dimensions for LXKx-Pxxx-xx12(A). Notes for Figure 5: 1. All dimensions are in millimeters. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 12 2 23 4.4 .9 5 5 LXKx-Pxxx-xx16(A) 1. 50 (2 PL PL C S) C 3.62 3.22 2 24 4.3 .0 5 5 S) 0.50 Max. runner height from PCB surface B 8.37 (2PLCS) 2. S) C ) S PL C PL (2 60 (2 5. 80 3.30 (3PLCS) Dome Pitch 0.80 (2PLCS) 6 25.15 24.85 4.63 (2PLCS) 45 .0 ° 1.65 1.50 (2PLCS) 2 (2PLCS) 12.10 11.90 (2PLCS) 11.10 10.90 (2PLCS) 10.70 A 3 (2 10.97 (2PLCS) A 5.80 0.76 Silicone height from PCB surface 3.30 (3PLCS) Dome Pitch R1.50 (16PLCS) 1.265 1.045 Board Thickness 1.65 3.35 3.25 (2PLCS) 1 2.35 2.25 (2PLCS) 2 DETAIL A SCALE 8 : 1 R0.70 (4PLCS) S) 1.92 0.97 2D BARCODE 3 Wir .30 es lot (2P LC 6.75 2.20 13.50 R1 (2PLCS) 6.75 13.50 R1 (2PLCS) DETAIL B SCALE 4 : 1 Figure 6. Dimensions for LXKx-Pxxx-xx16(A). Notes for Figure 6: 1. All dimensions are in millimeters. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 13 LXKx-Pxxx-xx24(A) 30.15 29.85 18.30 9.15 C1.1 x 45 (2X) 8.20 (2X) 0.50 Max. runner height from PCB surface R4.05 (3X) 1.50 (2X) 4.90 4.70 (4PLCS) 15 3 (2X) R1.50 (2PLCS) 3.62 3.22 A 14.40 14.20 (4PLCS) 3.6mm x 45 CHAMFER 2 (2PLCS) 5.33 (2PLCS) C1.1 x 45 A 11.84 (4PLCS) 1.50 (2PLCS) 1.265 1.045 Board Thickness R1 1.15 7 (2X) 4.667 (2X) 2.333 (2X) ) PLCS R1 (4 2.05 0.35 R1.50 (24PLCS) 2.333 (2X) 7 (2X) 1.35 (2X) R0.75 4.667 (2X) 15 12.27 (4PLCS) 13.40 13.20 (4PLCS) 10 (2PLCS) 30.25 29.75 18.30 15 LCS) 5 (4P R1.6 e slot ir W R1 CS) (4PL 1.35 0.76 Silicone height from PCB surface R1.20 2D barcode 2.35 2.25 (4PLCS) 3.35 3.25 (4PLCS) 1 DETAIL A SCALE 6 : 1 Figure 7. Dimensions for LXKx-Pxxx-xx24(A). Notes for Figure 7: 1. All dimensions are in millimeters. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 14 Relative Spectral Distribution vs. Wavelength Characteristics LXK8-PWxx-xxxx at Test Current, Junction Temperature = 85°C Figure 8. Color spectrum of LXK8-PWxx-xxxx product, integrated measurement. LXK0-PR04-xxxx (Royal Blue) at Test Current, Junction Temperature = 85°C Figure 9. Color spectrum of LXK0-PR04-xxxx product, integrated measurement. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 15 Light Output Characteristics over Temperature All LUXEON K Products at Test Current, Normalized at Test Current, Junction Temperature = 85°C Figure 10. Typical relative flux vs. junction temperature at test current. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 16 Typical Forward Current Characteristics Typical Forward Current vs. Forward Voltage LUXEON K 3-up Products, Junction Temperature = 85°C Figure 11. Forward current vs. forward voltage for LXKx-Pxxx-x403 products. Typical Forward Current vs. Forward Voltage LUXEON K 4-up Products, Junction Temperature = 85°C Figure 12. Forward current vs. forward voltage for LXKx-Pxxx-0004(A) products. Note for Figure 12: 1. LUXEON LXKx-Pxxx-0004(A) is single junction product. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 17 Typical Forward Current vs. Forward Voltage LUXEON K 4-up High-Voltage Products, Junction Temperature = 85°C Figure 13. Forward current vs. forward voltage for LXKx-Pxxx-x404 products. Typical Forward Current vs. Forward Voltage LUXEON K 6-up High-Voltage Products, Junction Temperature = 85°C Figure 14. Forward current vs. forward voltage for LXKx-Pxxx-x206 products. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 18 Typical Forward Current vs. Forward Voltage LUXEON K 8-up Products, Junction Temperature = 85°C Figure 15. Forward current vs. forward voltage for LXKx-Pxxx-xxx8(A) products. Typical Forward Current vs. Forward Voltage LUXEON K 12-up Products, Junction Temperature = 85°C Figure 16. Forward current vs. forward voltage for LXKx-Pxxx-xx12(A) products. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 19 Typical Forward Current vs. Forward Voltage LUXEON K 16-up Products, Junction Temperature = 85°C Figure 17. Forward current vs. forward voltage for LXKx-Pxxx-xx16(A) products. Typical Forward Current vs. Forward Voltage LUXEON K 24-up Products, Junction Temperature = 85°C Figure 18. Forward current vs. forward voltage for LXKx-Pxxx-xx24(A) products. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 20 Typical Relative Luminous Flus vs. Forward Current for ALL LUXEON K Product Configurations Without Multi-Junction Die, Junction Temperature 85°C Figure 19. Typical relative luminous flux vs. forward current. Typical Relative Luminous Flus vs. Forward Current for ALL LUXEON K Product Configurations With Multi-Junction Die, Junction Temperature 85°C Figure 20. Typical relative luminous flux vs. forward current for LUXEON K (LXKx-PWxx-0206) with multi-junction die. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 21 Typical Relative Luminous Flus vs. Forward Current for LUXEON K LXKx-PWxx-0403/LXKx-PWxx-0404 Product Configurations With Multi-Junction Die, Junction Temperature 85°C Figure 21. Typical relative luminous flux vs. forward current for LUXEON K (LXKx-PWxx-0403/LXKx-PWxx-0404) with multi-junction die. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 22 Typical Radiation Patterns Typical Spatial Radiation Pattern for LUXEON K 120 Relative Intensity (%) 100 80 60 40 20 0 -90 -75 -60 -45 -30 -15 0 15 30 45 60 75 90 Angular Displacement (degrees) Figure 22. Typical representative spatial radiation pattern for LUXEON K. Packaging on Trays LUXEON K products will be securely packaged in trays. Table 8. Part Number Tray Dimensions Quantity per Tray Number of Trays per Box LXKx-Pxxx-xxx3 LXKx-Pxxx-xxx4(A) 315mm width x 135.9mm length x 12.11mm depth 40 10 LXKx-Pxxx-xxx6 LXKx-Pxxx-xxx8(A) 315mm width x 135.9mm length x 12.11mm depth 27 10 LXKx-Pxxx-xx12(A) LXKx-Pxxx-xx16(A) 315mm width x 135.9mm length x 12.11mm depth 24 10 LXKx-Pxxx-xx24 315mm width x 135.9mm length x 12.11mm depth 21 10 LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 23 Tray Dimensions – LXKx-Pxxx-xxx3 and LXKx-Pxxx-xxx4(A) Figure 23. Tray Dimensions – LXKx-Pxxx-xxx6 and LXKx-Pxxx-xxx8(A) Figure 24. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 24 Tray Dimensions – LXKx-Pxxx-xx12(A) and LXKx-Pxxx-xx16(A) Figure 25. Tray Dimensions – LXKx-Pxxx-xx24(A) Figure 26. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 25 LUXEON K White ANSI Color Bin Definition 0.440 2700K ANSI 3000K ANSI 0.420 Blackbody Locus 3500K ANSI 4000K ANSI CIE E 1931 y 0.400 0.380 5000K ANSI 0.360 2700K 3-step MacAdams Ellipse 3000K 3-step MacAdams Ellipse 0.340 3500K 3-step MacAdams Ellipse 4000K 3-step MacAdams Ellipse 0.320 0.320 5000K 3-step MacAdams Ellipse 0.340 0.360 0.380 0.400 0.420 0.440 0.460 0.480 0.500 CIE 1931 x Figure 27. Graph of LUXEON K ANSI bin color definition. Table 9. LUXEON K 3-step MacAdams Ellipse Color Definition 2700K 3000K 3500K 4000K 5000K Nominal ANSI CCT Single 3-step MacAdam ellipse Single 3-step MacAdam ellipse Single 3-step MacAdam ellipse Single 3-step MacAdam ellipse Single 3-step MacAdam ellipse Center Point (cx, cy)[1] (0.4578, 0.4101 ) (0.4338, 0.4030) (0.4073, 0.3917) (0.3818, 0.3797) (0.3447, 0.3553) Major Axis, a 0.0081 0.00834 0.00927 0.00939 0.00822 Minor Axis, b 0.0042 0.00408 0.00414 0.00402 0.00354 Ellipse rotation angle 53.7° 53.22° 54.00° 53.72° 59.62° Note for Table 9: 1. Philips Lumileds maintains a tester tolerance of ±0.005 on x, y color coordinates. LUXEON K Datasheet DS102 20140404 ©2014 Philips Lumileds Lighting Company. 26 Who We Are Philips Lumileds focuses on one goal: Creating the world’s highest performing LEDs. The company pioneered the use of solid-state lighting in breakthrough products such as the first LED backlit TV, the first LED flash in camera phones, and the first LED daytime running lights for cars. Today we offer the most comprehensive portfolio of high quality LEDs and uncompromising service. Philips Lumileds brings LED’s qualities of energy efficiency, digital control and long life to spotlights, downlights, high bay and low bay lighting, indoor area lighting, architectural and specialty lighting as well as retrofit lamps. Our products are engineered for optimal light quality and unprecedented efficacy at the lowest overall cost. By offering LEDs in chip, packaged and module form, we deliver supply chain flexibility to the inventors of next generation illumination. Philips Lumileds understands that solid state lighting is not just about energy efficiency. It is about elegant design. Reinventing form. Engineering new materials. Pioneering markets and simplifying the supply chain. It’s about a shared vision. Learn more about our comprehensive portfolio of LEDs at www.philipslumileds.com. Philips Lumileds Lighting Company shall not be liable for any kind of loss of data or any other damages, direct, indirect or consequential, resulting from the use of the provided information and data. Although Philips Lumileds Lighting Company has attempted to provide the most accurate information and data, the materials and services information and data are provided “as is” and Philips Lumileds Lighting Company neither warranties, nor guarantees the contents and correctness of the provided information and data. Philips Lumileds Lighting Company reserves the right to make changes without notice. You as user agree to this disclaimer and user agreement with the download or use of the provided materials, information and data. ©2014 Philips Lumileds Lighting Company. All rights reserved. LUXEON is a registered trademark of the Philips Lumileds Lighting Company in the United States and other countries. www.philipslumileds.com www.philipslumileds.cn.com LUXEON K Datasheet DS102 20140404