MORNSUN B0505JS-2W Single output sip package dc-dc converter Datasheet

B_JS-2W
2W,FIXED INPUT, ISOLATED & UNREGULATED
SINGLE OUTPUT SIP PACKAGE DC-DC CONVERTER
RoHS
PRODUCT PROGRAM
FEATURES
SIP Package
1000VDC Isolation
High Power Denisity
Temperature Range: -40°C to +85°C
No Heat sink Required
No External Component Required
Industry standard pinout
Internal SMD construction
RoHS compliance
Input
Part
Number
B0505JS-2W
B1205JS-2W
Output
Voltage (VDC)
Nominal
Range
Max
Min
5
4.5-5.5
5
400
40
78
12
10.8-13.2
B1212JS-2W
B1515JS-2W
Efficiency
(%, Typ.)
Current (mA)
Voltage
(VDC)
15
13.5-16.5
5
400
40
78
12
167
17
80
15
133
14
82
APPLICATIONS
The B_JS-2W Series is specially designed
for applications where a single power supply is
isolated from the input power supply in a
distributed power supply system on a circuit
board.
These products apply to:
1) Where the voltage of the input power
ISOLATION SPECIFICATIONS
supply is fixed (voltage variation ≤±10%);
2) Where isolation is necessary between
input and output (isolation voltage≤1000VDC);
3) Where the regulation of the output
voltage and the output ripple noise are not
Item
Test Conditions
Isolation voltage
Tested for 1 minute and 1mA max
1000
Min
VDC
Isolation resistance
Test at 500VDC
1000
MΩ
Isolation Capacitance
demanding.
Typ
Max
50
Units
pF
Such as: purely digital circuits, ordinary low
frequency analog circuits.
OUTPUT SPECIFICATIONS
Item
MODEL SELECTION
Test Conditions
Min
Output power
B0505JS-2W
Line regulation
R ated Pow er
Package Style
Output Voltage
Input Voltage
Product Series
Load regulation
Typ
0.2
Max
Units
2
W
±1.2
For Vin change of 1%
10%to100% load (5V output)
12.8
15
10%to100% load (12V output)
6.8
10
Output voltage accuracy
%
See tolerance envelope graph
Temperature drift
100% full load
Ripple &Noise*
20MHz Bandwidth
75
Address: No. 5, Kehui St. 1, Kehui development
center, Science Ave., Guangzhou Science City,
Luogang district, Guangzhou,P.R.China.
Switching frequency
Full load, nominal input
500
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2. See below recommended circuits for more details.
3. Operation under minimum load will not damage the converter; However, they may not meet all
specification listed, and that will reduce the life of product.
MORNSUN Science & Technology Co.,Ltd.
MORNSUN reserves the copyright
0.03
%/°C
150
mVp-p
KHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of
Power Converter section, application notes.
Specifications subject to change without notice.
B_JS-2W
A/2-2012
Page 1 of 2
COMMON SPECIFICATION
Item
Test condition
Min
Typ
Storage humidity
Max
Units
95
%
Operation temperature
-40
85
Storage temperature
-55
125
Temp. rise at full load
15
Lead temperature
circuit of these products has no protection
against over-current and short-circuits. The
simplest method is to connect a self-recovery
°C
25
1.5mm from case for 10 seconds
Overload Protection
Under normal operating conditions, the output
fuse in series at the input end or add a circuit
breaker to the circuit.
300
Short circuit protection*
1
Cooling
Recommended and testing circuit
If you want to further decrease the input/output
Free air convection
ripple, an “LC” filtering network may be connected
Plastic (UL94-V0)
to the input and output ends of the DC/DC
Case material
MTBF
s
3500
K hours
Weight
2.9
converter, see (Figure 1).
g
L
L
*Supply voltage must be discontinued at the end of short circuit duration.
+Vo
Vin
Cin
DC DC
Cout
GND
0V
TYPICAL CHARECTERISTICS
(Figure 1)
It should also be noted that the inductance
and the frequency of the “LC” filtering network
should be staggered with the DC/DC frequency
to avoid mutual interference. However, the
capacitance of the output filter capacitor must be
proper. If the capacitance is too big, a startup
Ambient Temperature ( C )
output, provided the safe and reliable operation
OUTLINE DIMENSIONS & PIN CONNECTIONS
is ensured, the recommended capacitance of its
RECOMMENDED FOOTPRINT
MECHANICAL DIMENSIONS
filter capacitor sees (Table 1).
∅1.00 [0.039]
(Front View)
10.00 [0.394]
1 2
problem might arise. For every channel of
6
4
EXTERNAL CAPACITOR TABLE(TABLE 1)
Vin
Cin
Single Vout
Cout
(VDC)
(uF)
(VDC)
(uF)
5
4.7
5
10
4.10 [0.161]
0.50 [0.020]
N ote: grid 2.54*2.54mm .
0.50 [0.020]
19.60 [0.772]
4
2
6
10.16
[0.400]
2.54 [0.100]
FOOTPRINT DETAILS
Pin
9.60
[0.378]
0.30 7.00 [0.276]
[0.012]
12.40 [0.488]
1
16.9 0 [0.665]
0.90 [0.035]
1
Vin
GND
4
0V
5
No Pin
6
+Vo
N ote:
U nit:mm[inch]
Pin section tolerances:± 0.10mm[± 0.004inch]
General tolerances:± 0.25mm [± 0.010inch]
12
2.2
2.2
15
1
Output Voltage Regulation and Over-voltage
Protection Circuit
The simplest device for output voltage
regulation,
over-voltage
and
over-current
protection is a linear voltage regulator with
F unction
2
2.2
15
It’s not recommend to connect any external capacitor
in the application field with less than 0.5 watt output.
TUBE OUTLINE DIMENSIONS
(Bottom View)
12
overheat protection that is connected to the
4.90 [0.193]
Note:
Unit :mm[inch]
General tolerances: ±0.50mm[±0.020inch]
L=530mm[20.866inch] Tube Quantity: 25pcs
L=220mm[8.661inch] Tube Quantity: 10pcs
Short tube inner packaging dimensions: L*W*H=255*170*80mm;
Short tube outer packaging dimensions(with six inner packaging boxes):
L*W*H=375*280*270mm;
Long tube inner packaging dimensions: L*W*H=580*200*100mm;
Long tube outer packaging dimensions(with two inner packaging boxes) :
L*W*H=600*215*220mm;
Long tube outer packaging dimensions(with three inner packaging boxes) :
L*W*H=600*215*325mm.
input or output end in series (see Figure 2).
Vin
GND
APPLICATION NOTE
Vin
Requirement On Output Load
To ensure this module can operate efficiently and reliably, a minimum load is specified
GND
+Vout
REG
DC DC
0V
REG
+Vout
DC DC
0V
(Figure 2)
for this kind of DC/DC converter in addition to a maximum load (namely full load). During
operation, make sure the specified range of input voltage is not exceeded, the minimum
output load could not be less than 10% of the full load. If the actual output power is
No parallel connection or plug and play.
very small, please connect a resistor with proper resistance at the output end in parallel
to increase the load, or use our company’s products with a lower rated output power
(B_JS –1W Series).
MORNSUN reserves the copyright