CINT3110 110W Triple Output Industrial Series Features 2” x 4” x 1.3” Package Suitable for 1U Applications 110W w/air, 80W convection cooled Universal Input 90-264Vac Efficiency 87% typical Approved to CSA/EN/IEC/UL60950-1, 2nd Edition Power Fail Signal Remote Sense 3 Year Warranty RoHS Compliant Description The CINT3110 Series are industrial grade, high efficiency, triple output power supplies in a small 2” x 4” size. The CINT3110 family is ideal for Industrial and ITE applications requiring multiple outputs and small footprint. Compliant to nd IEC60950-1 2 edition, the CINT3110 models feature outputs of 5/±12V, 5/±15V, 5/±24V, includes a Power Fail/DC OK signal, and meet Class B Conducted EMI. Model Selection Model Number CINT3110A0508K01 CINT3110A1708K01 CINT3110A1908K01 Notes: Volts* Output Current** w/200LFM air Convection Ripple & Noise*** Total Regulation OVP Threshold V1 5V 14.0A 10.0A 1.0% pk-pk ±2% 7.5V max. V2 12V 6.0A 4.5A 1.0% pk-pk ±3% 115%-135% V3 -12V 1.0A 1.0A 2.0% pk-pk ±10% 115%-135% V1 5V 14.0A 10.0A 1.0% pk-pk ±2% 7.5V max. V2 15V 4.5A 3.5A 1.0% pk-pk ±3% 115%-135% V3 -15V 1.0A 1.0A 2.0% pk-pk ±10% 115%-135% V1 5V 12.0A 8.0A 1.0% pk-pk ±2% 7.5V max. V2 24V 4.0A 3.0A 1.0% pk-pk ±3% 115%-135% V3 -24V 1.0A 1.0A 2.0% pk-pk ±10% 115%-135% * 5V output is adjustable with +/-10% range ** Total convection power is 80 Watts. *** Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. Ripple & Noise of V2 at no load is 2% maximum. General Specifications AC Input Input Current www.slpower.com 100-240Vac, ±10%, 47-63Hz, 1∅ 120–370Vdc Turn On Time Less than 2 sec. @115Vac (inversely proportional to input voltage and thermistor temperature) 115Vac: 1.5A, 230Vac: 0.75A Hold-up Time 16mS typical at 110W, 120Vac input CINT3110 REV 1.2, 19-SEP-14 1 CINT3110 110W Triple Output Industrial Series General Specifications (continued) Inrush Current Input Fuses Earth Leakage Current Efficiency Output Power Transient Response Signals 264Vac, cold start: will not exceed 45A Overload Protection F1, F2: 2.5A, 250Vac fuses provided on all models Short Circuit Protection <290µA@264Vac, 60Hz, NC Overvoltage Protection 87% typical at 230Vac 110W continuous with 200 lfm airflow, 80W convection cooled – See chart for specific voltage model ratings. Switching Frequency 500µS typ. for return to within 0.5% of nominal, 50% load step. ∆i/∆t <0.2A/µS. Max Volt Deviation = 3% Isolation AC Power Fail, DC OK 150%-300% above rating for V2 & V3, 110%200% for V1. Hiccup Mode Provided - no damage will occur if the output is shorted. See models chart for trip range. PFC: 75kHz typical Input-Output: 4000Vac Input-Ground: 1800Vac Output-Ground: 500Vac Ripple and Noise See models chart Operating Temperature -10°C to +70°C Output Voltage See models chart Temperature Derating Derate output power linearly above 50°C to 50% at 70°C +/-10% from nominal on 5V output Storage Temperature -40°C to +85°C Voltage Adjustability Minimum Load Total Regulation Vibration Dimensions Weight Altitude Not required Relative Humidity See models chart Operating: 0.003g²/Hz, 1.5grms overall, 3 axes, 10 min/axis Non-Operating: 0.026g²/Hz, 5.0grms overall, 3 axes, 1 hr/axis Shock Safety Standards W: 2.0” x L: 4.0” x H: 1.3” MTBF 200g Operating: -500 to 10,000 ft. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total EN/CSA/UL/IEC 60950-1, 2nd Edition 245,000 hours, 25°C Ambient, 110Vac input Auxiliary Signals AC Power Fail: During normal operation, stays HIGH. Signal goes LOW with at least 6mS warning before loss of DC output from AC failure. Remote Sense: (5V output, optional) Will compensate for 0.5V drop min. Will operate without remote sense connected. Reverse connection protected. DC OK: Open collector logic signal goes and stays HIGH 100mS to 500mS after main output reaches regulation. Notes: 1. Specifications are for convection rating at factory settings at 115 Vac input, 25°C ambient unless otherwise stated. 2. For DC input an external DC safety rated fuse must be used. www.slpower.com CINT3110 REV 1.2, 19-SEP-14 2 CINT3110 110W Triple Output Industrial Series EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15, Subpart B, Class B Radiated Emissions EN55011/22 Class A; FCC Part 15, Subpart A, Class A Static Discharge Immunity EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. Criteria A EFT/Burst Immunity EN61000-4-4, 2kV/5kHz, Criteria A Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A Conducted RF Immunity EN61000-4-6, 3Vrms, Criteria A Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m, Criteria A Voltage Dip Immunity EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5 cycles; 70% Vin, 25 cycles; Criteria A Line Harmonic Emissions EN61000-3-2, Class A, B, C, & D Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing Notes: 1. All dimensions in inches (mm), tolerance is ±.02”. 2. Mounting holes should be grounded for EMI purpose 3. Mounting J101 is safety ground connection 4. This power supply requires mounting on metal standoffs 0.20” (5 m) in height. www.slpower.com CINT3110 REV 1.2, 19-SEP-14 3 CINT3110 110W Triple Output Industrial Series Connector Information Input Connector J100 PIN 1) AC NEUTRAL PIN 2) EMPTY PIN 3) AC LINE Mating Connector: Molex 09-50-3031 Pins= 08-52-0072 AMP #640250-3 Pins= 3-640706-1 Ground J101 0.187” FASTON TAB Mating Connector: Molex 01-90020001 DC Output Connector J200 PIN 1) +V1 PIN 2) +V1 PIN 3) GND PIN 4) GND PIN 5) GND PIN 6) GND Signal Connector J300 PIN 7) V2 PIN 8) V3 Mating Connector: Amp #640250-8 Pins=Amp #3-640706-1 PIN 1) Power Fail/DC OK PIN 2) GND PIN 3) +Remote Sense PIN 4) –Remote Sense Mating Connector: Amp #1375820-4 Pin= Amp #1375819 Isolation Specifications Parameter Conditions/Description Insulation Safety Rating Input/Ground Input/Output Output/Ground Electric Strength Test Voltage Input/Ground Input/Output Output/Ground Min Nom Max Units - Vac Vac Vac Basic Reinforced Operational 1800 4000 500 - Leakage Current Parameter Conditions/Description Max Earth Leakage Current Normal Condition (NC) Single Fault Condition (SFC) 290µA 420µA Touch Current Normal Condition (NC) Single Fault Condition (SFC) 90µA 170µA Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Input Voltage Input Frequency Input Current Min Nom Max Units 90 115/230 264 Vac 47 50/60 115Vac/max load 63 Hz 1.5 A Input Current 230Vac/max load 0.75 A Inrush Current 264Vac, cold start, 25°C - - 45 A Efficiency Vi nom, Io nom CINT3110A0508K01 CINT3110A1708K01 CINT3110A1908K01 - 87% - % Parameter Conditions/Description Min Nom Max Units Output Current V1 Output Current V2 Output Current V3 CINT3110A0508K01 0 0 0 10.0 4.5 1 14.0 6.0 1 ADC Output Current V1 Output Current V2 Output Current V3 CINT3110A1708K01 0 0 0 10.0 3.5 1 14.0 4.5 1 ADC Output Current V1 Output Current V2 Output Current V3 CINT3110A1908K01 0 0 0 8.0 3.0 1 12.0 4.0 1 ADC Output Specifications www.slpower.com CINT3110 REV 1.2, 19-SEP-14 4 CINT3110 110W Triple Output Industrial Series Output Specifications (continued) Parameter Conditions/Description Min Nom Max Units Static Line Regulation V1 Vi min-Vi max, Vi nom, 0-100% Io1 max -2 - 2 % Vo nom Static Line Regulation V2 Vi min-Vi max, Vi nom, 0-100% Io2 max -3 - 3 % Vo nom Static Line Regulation V3 Vi min-Vi max, Vi nom, 0-100% Io3 max -10 - 10 % Vo nom Static Load Regulation V1 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io1 max -2 - 2 % Vo nom Static Load Regulation V2 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io2 max -3 - 3 % Vo nom Static Load Regulation V3 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io3 max -10 - 10 % Vo nom Hold-Up Time Vin = 120Vac, Po = 110W 16 - - mS Dynamic Load Regulation V1, V2, V3 Load change =50%, di/dt = 0.2A/µS 0 3 % Vo nom Start-Up Time Vin = 115Vac, Io nom 0 2 S Ripple & Noise V1 20MHz bandwidth 0 1% % Vo nom Ripple & Noise V2 20MHz bandwidth 0 1% % Vo nom Ripple & Noise V3 20MHz bandwidth 0 2% % Vo nom Max Units - Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Min Input Fuse T2.5A/250V internal fuse in both line & neutral Input Transient Protection 2KV(CM) and 1KV(DM) surge Nom Not user accessible 2 Short Circuit Protection KV (CM) Hiccup Mode Overload Protection Hiccup Mode Overvoltage Protection Latching Type, recycle AC input to reset Characteristic Curves See models chart for trip ranges (Note: All waveforms below are based on CINT3110A0508K01 model) Output vs. Temperature 80W convection cooled and 110W continuous with 200 LFM airflow. Derate output power to 50% at 70°C. 120 Output Power (W) 100 80 60 40 20 0 -10 0 10 20 30 40 50 60 70 Temperature (°C) www.slpower.com Convection 200LFM Cooling CINT3110 REV 1.2, 19-SEP-14 5 CINT3110 110W Triple Output Industrial Series Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with 0.1µF ceramic and a 10µF electrolytic capacitor connected in parallel across it, BW limit with 20MHz. Output Transient Response V1 50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3%. Output Transient Response V2 50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3%. www.slpower.com CINT3110 REV 1.2, 19-SEP-14 6 CINT3110 110W Triple Output Industrial Series Output Transient Response V3 50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3%. Output Overload Characteristic V1 Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention. Output Overload Characteristic V2 www.slpower.com CINT3110 REV 1.2, 19-SEP-14 7 CINT3110 110W Triple Output Industrial Series Output Overload Characteristic V3 Output Short Circuit Characteristic V1 Supply shall protect itself against Short Circuit conditions. The Power Supply shall recover from short circuit conditions without operator intervention. Output Short Circuit Characteristic V2 www.slpower.com CINT3110 REV 1.2, 19-SEP-14 8 CINT3110 110W Triple Output Industrial Series Output Short Circuit Characteristic V3 Output Overvoltage Characteristic V1 Supply shall protect itself against over voltage conditions. The Power Supply shall latch and require AC input recycle to reset. AC input 90V 60Hz AC input 264V 50Hz Output Overvoltage Characteristic V2 www.slpower.com CINT3110 REV 1.2, 19-SEP-14 9 CINT3110 110W Triple Output Industrial Series Output Overvoltage Characteristic V3 Startup Time Hold-up Time Start up time is <2seconds Hold up time is 16mS minimum Power Fail Signal Timing Active Low TTL logic signal goes high 100 - 500 ms after main output; it goes low at least 6 mS before loss of regulation. Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com CINT3110 REV 1.2, 19-SEP-14 10