Technical Data Sheet RF_35/05.10/6.0 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG 3/8” JUMPER 4.3-10 MALE – 4.3-10 MALE SLJ38SF-64M64M-X-00 Function description This part is a coaxial cable assembly for telecommunication equipment. It consists of 3/8” super flexible coaxial cable with FRNC jacket and two 4.3-10 male connectors. The assembly is waterproof in mated condition, fire retardant and UV protected. Available variants The assembly is available in lengths from 0.5 m to 10 m in intervals of 0.5 m. Different feet length are available on request. Assembly parts Connector 4.3-10 male (type 1) connectors plated with white bronze Cable S-Link 3/8”S, FRNC jacket Marking 1 Direct print onto the cable or one wrapping label Marking includes manufacturer, part nr. & batch no. Marking 2 Direct print onto the cable or on wrapping label Marking includes “Rosenberger factory made” Position in the middle of the cable Bend protection molding material PE compound with flame retardant Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : [email protected] Page 1/2 Technical Data Sheet 3/8” JUMPER SLJ38SF-64M64M-X-00 4.3-10 MALE – 4.3-10 MALE RF_35/05.10/6.0 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG Electrical data Impedance Frequency Return loss DC – 1 GHz 1 – 2.2 GHz 2.2 – 2.7 GHz Insertion loss typ. DC – 1 GHz 1 – 2.2 GHz 2.2 – 2.7 GHz Intermodulation (3rd order @ 2 x 20 W) Relative Velocity of Propagation DC Breakdown Voltage 50 DC to 2.7 GHz 32 dB 30 dB 28 dB 0.14 dB/m (cable) + 0.01 dB * f (GHz) 0.21 dB/m (cable) + 0.01 dB * f (GHz) 0.24 dB/m (cable) + 0.01 dB * f (GHz) typ. max. -120 dBm -117 dBm 82 % 2000V Mechanical data Coupling torque (recommended) 5 to 8 Nm Spanner flat on coupling nut 22 mm Cable diameter, jacket 10.2 mm typ. Tensile strength 500 N Recommended hanger spacing 0.6 m Minimum bend radius single 13 mm* Minimum bend radius repeated 25 mm* *Bending starts behind connector incl. kink protection Environmental data Operation temperature range Installation temperature range Degree of protection RoHS -30 °C to +80 °C -25 °C to +60 °C IEC 60529, IP68 1 bar for 1 h (mated) compliant While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our products, we reserve the right to make changes judged to be necessary. Draft Date Approved Date Rev. Engineering change number Name Date M. Wimmer 02.09.2014 A. Gasteiger 06.10.2015 a00 15-s359 Fl. Öllerer 06.10.15 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : [email protected] Page 2/2