Power-One ABC60-3003G 60 w convection cooled, conducted emi en 55022-b, fcc part 15 level b Datasheet

DATA SHEET
ABC60 SERIES 60W AC/DC
FEATURES

60 W convection cooled

-20 to 50 deg C full load operation

90-264 VAC input

2” x 4 “ x 1.2” (101.6 x 50.8 x 30.48 mm)

No minimum load required - single output models

Conducted EMI EN 55022-B, FCC Part 15 Level B

ITE Safety Agency Approvals

RoHS Compliant

No load power < 0.3 W
APPLICATIONS

Instrumentation

Automation Controls

Lighting

Wireless Data

Industrial Applications

Communication Systems

Applied Computing

Test and Measurement

Renewable Energy

Robotics
BCD.00282_AA_June-26-2013
1
www.power-one.com
DATA SHEET
TECHNICAL DATA:
Input
PARAMETER
DESCRIPTION/CONDITION
Input voltage range.
Input frequency range
Input surge current
Safety ground leakage current
Universal Input
47 to 400 Hz. (3)
264 Vac (cold start)
120 Vac < 500 uA
120 Vac @ 60 W
230 Vac @ 60 W
Input current
90 - 264 Vac
40 A max.
230 Vac < 1000 uA
1.5 A
0.75 A
Output
PARAMETER
DESCRIPTION/CONDITION
Voltage Adjustment
V1
Main output 50 to 100% load change, 50 Hz,
50% duty cycle, 0.1 A / u Sec, 50/60 Hz
130% Typical
130% Typical
V1
>85%
V1 = ± 3%, V2 & V3 = ± 5%
100 mSec
Transient Response
Over Voltage Protection
Short Circuit Protection
Remote Sense
Efficiency
Set Point Tolerance
Rise Time
± 10%
< 10%, recovery time < 5 mSec
0.5 Vdc compensation
Ordering Information
PRODUCT
FAMILY
VOLTS
(VDC)
OUTPUT CURRENT
MAX (A)
MINIMUM
LOAD (A) (4)
RIPPLE &
NOISE
TOTAL
REGULATION
OVP THRESHOLD
ABC60-1005G
5.2
10.0
0
1.25%
± 0.8%
130% Typical
ABC60-1012G
12
5.4
0
1%
± 0.8%
130% Typical
ABC60-1015G
15
4.33
0
1%
± 0.8%
130% Typical
ABC60-1024G
24
2.7
0
1%
± 0.8%
130% Typical
ABC60-1048G
48
1.35
0
1%
± 0.8%
130% Typical
5.2
8.0
0.5
1.25%
± 0.8%
130% Typical
ABC60-3000G
ABC60-3001G
ABC60-3002G
ABC60-3003G
ABC60 Series
12.5
3.0
0.1
1%
± 5.3%
-12.5
0.5
0.0
1%
± 5.3%
5.2
8.0
0.5
1.25%
± 0.8%
23.8
1.5
0.1
1%
± 5.3%
-12.5
0.5
0.0
1%
± 5.3%
5.2
8.0
0.5
1.25%
± 0.8%
14.6
2.5
0.1
1%
± 5.3%
-16.2
0.5
0.0
1%
± 5.3%
3.3
8.0
1.0
1.5%
± 0.8%
5.2
3.0
0.1
1%
± 5.3%
-12.8
0.5
0.0
1%
± 5.3%
2
130% Typical
130% Typical
130% Typical
www.power-one.com
DATA SHEET
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Maximum outputs for each output. Max power rating should not be exceeded.
Output noise measurement is made with a 20 MHz bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum
capacitor in parallel with a 0.1 uF ceramic capacitor.
Safety Approved: 47 to 63 Hz.
Minimum load specified to meet cross regulation.
Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.
Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.
Unit will turn on at -40° C and will operate but ripple and noise will be ± 3% for up to 5 minutes.
Specifications subject to change without notice.
Warranty 2 years.
General Specifications
PARAMETER
DESCRIPTION/CONDITION
Hold Up Time
MTBF
Switching Frequency
Isolation Voltage
Weight
6 mSec
>100 khrs
67 kHz typical
Input to Output: Min 4242 Vdc
150 g (0.33 lbs)
120 Vac input
MIL-HDBK-217F
Input to Ground 2120 Vdc
Environmental
PARAMETER
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Conducted emissions:
Radiated Emissions
Electromagnetic Susceptibility
Harmonic Current
DESCRIPTION/CONDITION
-20 to 50° C Full Load.
50 to 70° C
-40 to 70° C
95%
Operating 10,000 ft.
EN55022, FCC part 15 Level B
EN55022, FCC part 15 Level B
EN61000-4
EN61000-3-2, Class A
Full Load
Derate linearly to 50% at 70° C
Non-Condensing
Non-Operation 40,000 ft.
To be controlled in end system
2, 3, 4, 5 Level 3
Safety
PARAMETER
DESCRIPTION/CONDITION
EN / UL / CSA
EN60950-1+A12:2011, IEC60950-1 2nd+A1 2009, CSA-22.2 No 60950-01-07+ A1,
UL60950-1-2011
BCD.00282_AA_June-26-2013
3
www.power-one.com
DATA SHEET
Figure 1 Output Power Vs. Temperature
Figure 2 Dimension Drawing (Top and Side View)
Mechanical
INPUT = J1
EARTHING TAB = J4
DC OUTPUT = J2
Pin 1: AC Neutral
Pin 2: AC Line
Molex: 19705-4301
Pin 1 = V1
Pin 2 = V1
Pin 3 = RTN
Pin 4 = RTN
Pin 5 = V3
Pin 6 = V2
Mating Connector:
Molex: 09-50-3031
Pins: 08-50-0106
Mating Connector:
Molex: 190030001
Mating Connector:
Tyco: 647402-6; Pins: 3-647409-1
REMOTE SENSE = J3
Pin 1 = +V1 Sense
Pin 2 = -V1 Sense
Mating Connector:
Molex: 22-01-2021
Copyright © 2010 Power-One Inc. All rights reserved. Words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the
trademarks and service marks of Power-One Inc. in the U.S. and other countries. All other product or service names are the property of their respective holders.
Power-One products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Power-One reserves the
right to make changes to any products and services at any time without notice. Power-One assumes no responsibility or liability arising out of the application or use
of any information, product, or service described herein except as expressly agreed to in writing by Power-One Inc.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
ABC60 Series
4