XP Power CLG-100-20 100w single output switching power supply Datasheet

CLG-100
100W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage/Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High realibility
Suitable for LED lighting and moving sign applications
3 years warranty (Note.7)
( for 48V only)
SPECIFICATION
MODEL
CLG-100-12
CLG-100-15
12V
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
15V
20V
24V
48V
5A
4.8A
4A
27V
3.55A
36V
Note.6 5A
2.65A
2A
CURRENT RANGE
Note.6 0 ~ 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
0 ~ 3.55A
0 ~ 2.65A
0 ~ 2A
RATED POWER
Note.6 60W
75W
96W
96W
95.85W
95.4W
96W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
Fixed. Can be modified between 0% ~ -15% rated output voltage
CURRENT ADJ. RANGE
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3
3.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
3.0%
SETUP, RISE TIME
1200ms, 80ms / 230VAC
HOLD TIME (Typ.)
60ms / 230VAC
VOLTAGE RANGE
INPUT
IP67
RATED CURRENT
DC VOLTAGE
OUTPUT
CLG-100-20
( except for 48V )
3.0%
3.0%
2.0%
2.0%
1200ms, 80ms / 115VAC at full load
30ms / 115VAC at full load
Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.95/230VAC
EFFICIENCY (Typ.)
83%
AC CURRENT
INRUSH CURRENT(max.)
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
LEAKAGE CURRENT
0.5mA / 240VAC
OVER CURRENT
3.0%
Note.4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
PF>0.98/115VAC at full load
85%
87%
87%
15V:0.9A/115VAC
87%
0.45A/230VAC
87%
20V ~ 48V:1.1A/115VAC
87%
0.55A/230VAC
95 ~ 100%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
29 ~ 36V
39 ~ 48V
52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70
(Refer to output load derating curve), -40
possible
20 ~ 90% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310 Class 2, TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V),IP67 Approved
WITHSTAND VOLTAGE
I/P-O/P:4.25KVDC
SAFETY & ISOLATION RESISTANCE
I/P-O/P:100M Ohms/500VDC
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
OTHERS
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
301Khrs min. MIL-HDBK-217F (25 )
222*68*39mm (L*W*H)
1.0Kg; 12pcs/13Kg/0.49CUFT
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
File Name:CLG-100-SPEC 2006-08-30
CLG-100
100W Single Output Switching Power Supply
Mechanical Specification
Case No. 954A
series
Unit:mm
222.2
198.2
12
9.4
9.6
34.2
300 20
+V(Red)
-V(Black)
68
300 20
L(Brown)
N(Blue)
FG(Greed/Yellow)
18AWG 2C
9.4
18AWG 3C
38.75
4.2 4PL
Fosc : 100KHz
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
RECTIFIERS
&
FILTER
+V
-V
O.L.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
PFC
CONTROL
O.V.P.
OLP Characteristics
VO (%)
100
50
(max.)
0
50
95
(Vo Io<100VA)
IO(%)
Derating Curve
Static Characteristics
fosc : 100KHz
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:CLG-100-SPEC 2006-08-30
Similar pages