FKC15 SERIES DC-DC CONVERTER 2:1 WIDE INPUT RANGE UP TO 15 Watts FEATURES APPLICATIONS • NO MINIMUM LOAD REQUIRED • 1600VDC INPUT TO OUTPUT ISOLATION • STANDARD 1.25 X 0.80 X 0.40 INCH AND 24 PIN DIP PACKAGE • UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL UVP OCP • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • DISTRIBUTED POWER ARCHITECTURES • SEMICONDUCTOR EQUIPMENT SCP LOW STANDBY POWER TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted Model Number Input Range Output Voltage Output Current @Full Load Input Current @ No Load Efficiency Maximum Capacitor Load VDC 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 VDC 3.3 5.1 12 15 ±5 ±12 ±15 3.3 5.1 12 15 ±5 ±12 ±15 3.3 5.1 12 15 ±5 ±12 ±15 mA 4000 3000 1250 1000 ±1500 ±625 ±500 4000 3000 1250 1000 ±1500 ±625 ±500 4000 3000 1250 1000 ±1500 ±625 ±500 mA 10 10 5 10 10 6 10 6 6 4 6 4 6 6 4 4 4 4 4 4 4 % 87 90 90 90 86 90 90 88 90 91 91 87 90 90 88 90 90 91 87 90 90 µF 4700 3300 600 400 ±1500 ±288 ±200 4700 3300 600 400 ±1500 ±288 ±200 4700 3300 600 400 ±1500 ±288 ±200 FKC15-12S3P3 FKC15-12S05 FKC15-12S12 FKC15-12S15 FKC15-12D05 FKC15-12D12 FKC15-12D15 FKC15-24S3P3 FKC15-24S05 FKC15-24S12 FKC15-24S15 FKC15-24D05 FKC15-24D12 FKC15-24D15 FKC15-48S3P3 FKC15-48S05 FKC15-48S12 FKC15-48S15 FKC15-48D05 FKC15-48D12 FKC15-48D15 PART NUMBER STRUCTURE FKC15 - 48 Series Name Input Voltage (VDC) 12: 9~18 24:18~36 48:36~75 S 05 Output Quantity Output Voltage (VDC) 3P3: 3.3 05: 5.1 12:12 15:15 S:Single D: Dual 1 05:± 5 12:±12 15:±15 www.PDUKE.com 2014/04/30 FKC15 INPUT SPECIFICATIONS Parameter Conditions Operating input voltage range 12Vin(nom) 24Vin(nom) 48Vin(nom) 12Vin(nom) 24Vin(nom) 48Vin(nom) 12Vin(nom) 24Vin(nom) 48Vin(nom) Power up Remote ON/OFF 12Vin(nom) 24Vin(nom) 48Vin(nom) Start up voltage Shutdown voltage Start up time Constant resistive load Input surge voltage 1 second, max. Input reflected ripple current Input filter Remote ON/OFF Referred to –Vin pin No Load to Full Load 10% Load to 90% Load Asymmetrical load 25%/100% FL 20MHz bandwidth With a 1µF/25V X7R MLCC Min. Single Dual Single Dual Single Dual Dual VDC VDC ms VDC mAp-p Pi type Open or 3.0 ~ 12VDC Short or 0 ~ 1.2VDC +0.5 2.5 Typ. -1.0 -0.2 -0.5 -0.5 -1.0 -0.3 -0.8 -5.0 Unit +1.0 +0.2 +0.5 +0.5 +1.0 +0.3 +0.8 +5.0 % % of Iout rated; Hiccup mode Isolation voltage 1 minute Isolation resistance Isolation capacitance Switching frequency Safety approvals 500VDC Conditions Input to Output Input (Output) to Case www.PDUKE.com % % mVp-p +0.02 %/ 250 µs 3.9 6.2 VDC 15 18 150 % Continuous, automatics recovery Min. 1600 1600 1 297 MIL-HDBK-217F % ℃ -0.02 3.3Vout 5.1Vout 12Vout 15Vout mA mA Max. 60 25% load step change GENERAL SPECIFICATIONS Parameter 2 -0.5 Unit VDC 60 60 36 50 100 Conditions Load regulation Case material Base material Potting material Weight MTBF 18 36 75 9 18 36 8 16 33 DC-DC ON DC-DC OFF Input current of Ctrl pin Remote off input current Low Line to High Line at Full Load Over load protection Short circuit protection Max. 12 24 48 Positive logic Voltage accuracy Line regulation Temperature coefficient Transient response recovery time Over voltage protection Typ. 9 18 36 20 OUTPUT SPECIFICATIONS Parameter Cross regulation Ripple and noise Min. Typ. Max. Unit VDC GΩ pF 330 kHz UL60950-1 EN60950-1 IEC60950-1 Nickel-coated copper FR4 PCB Silicone (UL94 V-0) 14.4g (0.51oz) 1.797 x 106 hrs 2000 363 2014/04/30 FKC15 ENVIRONMENTAL SPECIFICATIONS Parameter Conditions Min. 3.3Vout, ±5Vout Operating ambient temperature Without derating With derating Without derating With derating Others Maximum case temperature Storage temperature range Thermal impedance Thermal shock Vibration Relative humidity Max. +60 +100 +73 +100 105 +125 -55 Natural convection 20 Unit ℃ ℃ ℃ ℃/W MIL-STD-810F MIL-STD-810F 5% to 95% RH EMC SPECIFICATIONS Parameter EMI(1) ESD Radiated immunity Fast transient (2) Surge (2) Conducted immunity Typ. -40 +60 -40 +73 Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Level Class A,Class B Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Air ± 8kV and Contact ± 6kV 10 V/m ± 2kV ± 2kV 10 Vr.m.s Note: 1. 2. The standard modules meet EMI Class A or Class B with external components. For further information, please contact with P-DUKE. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter Power Mate suggests: Nippon chemi-con KY series, 220µF/100V. CAUTION: This power module is not internally fused. An input line fuse must always be used. CHARACTERISTIC CURVE FKC15-48S05 Derating Curve FKC15-48S05 Efficiency vs. Input Voltage FKC15-48S05 Efficiency vs. Output Load MECHANICAL DRAWING PIN CONNECTION PIN SINGLE 1 Ctrl 2 -Vin 3 -Vin 9 11 NC NC DUAL Ctrl -Vin -Vin PIN SINGLE DUAL 23 22 +Vin +Vin +Vin +Vin Common -Vout 16 14 -Vout +Vout Common +Vout 1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1) 3 www.PDUKE.com 2014/04/30