Sensortechnics CTEM9200G4CXS Oem stainless steel submersible pressure transducer Datasheet

CTE9000 / CTU9000...CS Series
OEM stainless steel submersible pressure transducers
FEATURES
· 0...100 to 0...2000 mbar,
0...1.5 to 0...30 psi gage
· For corrosive media
· 4...20 mA output
· Field interchangeable
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), PUR, PE, ABS,
Loctite 603
Housing:
protection class IP 68 (according to DIN EN 60529)
respectively NEMA 6P1
ELECTRICAL CONNECTION
SPECIFICATIONS9,10
Maximum ratings
Supply voltage
(reverse polarity protection)2
Temperature limits
Storage
Operating
Compensated
Vibration (5 to 500 Hz)
Mechanical shock
Proof pressure3
CTEM9100..., CTEM9200...
CTU9001..., CTU9003...
all others
August 2008 / 594
9...32 V
+Vs
-40 to 70°C
-25 to 70°C
0 to 70°C
+9 to 32 V
red
sensor
10 gRMS
-Vs
black
50 g
V
RL
GND
bare
600 mbar
9 psi
2 x rated pressure
1/4
www.sensortechnics.com
CTE9000 / CTU9000...CS Series
OEM stainless steel submersible pressure transducers
INDIVIDUAL PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Operating pressure
Min.
Typ.
Max.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3.8
4.0
100
200
400
600
1000
1600
2000
1.5
3
5
10
15
20
30
4.2
15.8
16.0
16.2
0.1 bar / 1.5 psi
0.04
0.08
all others
0.02
0.05
0.05
CTEM9100...
CTEM9200...
CTEM9400...
CTEM9600...
CTEM91K0...
CTEM91K6...
CTEM92K0...
CTU9001...
CTU9003...
CTU9005...
CTU9010...
CTU9015...
CTU9020...
CTU9030...
Zero pressure offset
7
Full scale span
Thermal effects (0 to 70°C)4
Offset
Thermal effects (-25 to 0°C)
Non-linearity (BSL) and hysteresis
Span
0.02
Offset
0.03
Span
0.03
5
±0.2
Repeatability
±0.1
Output noise (0 < f < 1 kHz)
±0.04
Long term stability6
mbar
p si
mA
%FSO/°C
±0.5
%FSO
±0.1
Response time (10 to 90 %)
Power supply rejection
Unit
1
Offset
0.05
Span
0.08
Power consumption (IL = 20 mA)
260
ms
%FSO/V
mW
Specification notes (for all devices):
1. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting
cable. Thus the vent tube of the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagrams.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Long term stability is the change in output after one year or 1 million pressure cycles.
7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
8. Tests are in accordance with EN61000-6-2, April 1999.
9. CE-labelling is in accordance with 89/336/EEC.
10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
August 2008 / 594
2/4
www.sensortechnics.com
CTE9000 / CTU9000...CS Series
OEM stainless steel submersible pressure transducers
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion
Interference
Grade 3
10 V/m, 80 MHz to 1000 MHz
80 % AMC (1 kHz)
A
<1 % FSO
Radiated, radio frequency
electromagnetic field
immunity (RFI)
EN61000-4-3:
Electrical fast transient /
burst immunity (EFT)
EN61000-4-4:
Grade 3
±2 kV
B
<1 % FSO
Electrostatic discharge
immunity test (ESD)
EN61000-4-2:
Grade 4
±8 kV, contact discharge
B
<1 % FSO
Immunity to conducted
disturbances induced by
radio-frequency fields
EN61000-4-6:
Grade 3
0,15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
<1 % FSO
LOAD LIMITATION
1400
Ohm
1200
1000
800
op
e
ra ratin
ng g
e
600
400
200
0
August 2008 / 594
5
9
16 20
25 30 32 V
supply voltage
3/4
www.sensortechnics.com
CTE9000 / CTU9000...CS Series
OEM stainless steel submersible pressure transducers
OUTLINE DRAWING
NOM 2000
(78.74)
NOM 129.5 (5.10)
NOM 70
(2.76)
other cable lengths
on request
Ø 21.8
(0.86)
Ø 6.0 (0.24)
8.0 (0.31)
Hydrophobic filter
(incl. in delivery)
WIRE CONNECTION
mass: typ. 210 g (without cable)
Color
Electrical connection
red
+Vs
black
-Vs
transparent
vent tube1
bare
case/shield
dimensions in mm (inches)
ORDERING INFORMATION
CTx
M
9xxx
G
4
C
x
S
submersible
calibration
E: calibration in mbar
U: calibration in psi
cable length in m
mbar-ranges (only)
pressure range
100:
0 to 100 mbar
200:
0 to 200 mbar
400:
0 to 400 mbar
600:
0 to 600 mbar
1K0: 0 to 1000 mbar
1K6: 0 to 1600 mbar
2K0: 0 to 2000 mbar
Note:
cable version
001:
003:
005:
010:
015:
020:
030:
0 to 1.5
0 to 3
0 to 5
0 to 10
0 to 15
0 to 20
0 to 30
psi
psi
psi
psi
psi
psi
psi
output signal
4: 4...20 mA
pressure mode
G: gage pressure
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
August 2008 / 594
4/4
www.sensortechnics.com
Similar pages