DGNJDZ GBU601 Single phase 6.0 amp bridge rectifier Datasheet

GBU6005
THRU
GBU610
SINGLE PHASE 6.0 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
6.0 Ampere
FEATURES
* Ideal for printed circuit board
.139(3.53)
.133(3.37)
22.2(.874)
21.8(.860)
* Low forward voltage
* Low leakage current
.752(19.1)
.720(18.3)
.232(5.9)
.224(5.7)
* Polarity: marked on body
AC
+
* Mounting position: Any
.720(18.29)
.680(17.27)
* Both normal and Pb free product are available:
.083(2.1)
.075(1.9)
* Normal:80~95%Sn,5~20%Pb
.210 .210 .210
.190 .190 .190
(5.33) (5.33) (5.33)
(4.83) (4.83) (4.83)
* Pb free:99 Sn above can meet Rohs enviroment substance
directive request
.022(.56)
.018(.46)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
GBU6005
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
50
35
50
GBU601
100
70
100
GBU602
GBU604
GBU606
GBU608
GBU610
UNITS
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
V
V
V
.375"(9.5mm) Lead Length at Tc=50 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
6.0
A
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 3.0A D.C.
Maximum DC Reverse Current
Ta=25 C
200
1.0
5
A
V
uA
at Rated DC Blocking Voltage
Rating for fusing (t<8.3ms)
Storage Temperature Range, TSTG
Ta=100 C
100
127.0
-55 +150
uA
A2sec
C
RATING AND CHARACTERISTIC CURVES (GBU6005 THRU GBU610)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
6.0
5.0
4.0
Single Phase
3.0
Half Wave 60Hz
Resistive Or Inductive Load
2.0
1.0
0
25
50
75
100 125
150
175
CASE TEMPERATURE ( C)
PEAK FORWAARD SURGE CURRENT,(A)
AVERAGE FORWARD CURRENT,(A)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
250
200
150
8.3ms Single Half
Tj=25 C
Sine Wave
100
JEDEC method
50
1
5
50
10
100
FIG.3-TYPICAL FORWARD
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
CHARACTERISTICS
50
50
10
10
REVERSE LEAKAGE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT,(A)
NUMBER OF CYCLES AT 60Hz
3.0
1.0
Tj=25 C
Pulse Width 300us
1% Duty Cycle
0.1
3.0
Tj=100 C
1.0
0.1
Tj=25 C
.01
0
.2
.4
.6
.8
1.0
FORWARD VOLTAGE,(V)
1.2
1.4
.01
20
40
60
80
100 120 140
PERCENTAGE OF PEAK REVERSE VOLTAGE, (%)
Similar pages